Successfully reported this slideshow.
We use your LinkedIn profile and activity data to personalize ads and to show you more relevant ads. You can change your ad preferences anytime.

Toric lenses san diego 07

2,633 views

Published on

Perfect Vision's Dr Con Moshegov presentation on: Toric lenses san diego 07

Published in: Health & Medicine
  • Be the first to comment

Toric lenses san diego 07

  1. 1. Alcon AcrySof ® Toric IOL Con Moshegov Stephen Bambery Australia
  2. 2. IOL Design <ul><li>AcrySof Single piece foldable acrylic </li></ul><ul><li>Soft and malleable </li></ul><ul><li>Allows easy manipulation while positioning </li></ul><ul><li>Axis marks on the posterior surface </li></ul><ul><li>IOL placed with marks aligned with the steep axis of the cornea </li></ul>
  3. 3. <ul><li>Blue-light filter </li></ul><ul><li>Injector delivery same as conventional SN60AT IOLs </li></ul>
  4. 4. Other toric IOLs <ul><li>Silicone plate haptic: rotation in capsular bag has been an issue </li></ul><ul><li>First toric FDA approval </li></ul>
  5. 5. AcrySof Single Piece IOL <ul><li>Adhesive property </li></ul><ul><li>Advantage taken to prevent rotation after implantation </li></ul>Oshika T, et al. Adhesion of lens capsule to intraocular lenses of PMMA, silicon, and acrylic foldable materials: an experimental study. Br. J Ophthalmol , 1998;82:468.
  6. 6. IOL Design – Rotational Stability <ul><li>Lens stability is important </li></ul><ul><li>Off-axis rotation reduces the corrective cylinder power </li></ul>
  7. 7. <ul><li>For every 1°of rotation, 3.3% of the lens cylinder power is lost </li></ul><ul><li>For 30° of rotation there is a complete loss of astigmatic correction </li></ul><ul><li>Additional astigmatism or visual problems with greater than 30° of rotation </li></ul>
  8. 8. Error Induced from Cyclotorsional Movements <ul><li>Residual PSF and Blurred Eye Chart Letters </li></ul><ul><li>Real eye: –0.15DS –1.01DC x 0˚ </li></ul>
  9. 9. IOL Power Selection Process <ul><li>Determine the required spherical lens power </li></ul>
  10. 10. Select an AcrySof ® Toric IOL Model <ul><li>The data are entered into the AcrySof ® Toric IOL Calculator to determine the optimal model </li></ul><ul><li>Calculator </li></ul><ul><ul><li>Considers effect of incision location and surgically induced cylinder to make a more precise calculation </li></ul></ul><ul><ul><li>Determines the correct IOL model and optimal axis placement of the IOL in the capsular bag </li></ul></ul>
  11. 11. AcrySof ® Toric IOL Models <ul><li>Three AcrySof ® Toric IOL models available </li></ul><ul><li>Cylinder power option is combined with SE power 16 D to 25 D in 0.5 D increments </li></ul><ul><li>Additional power options will be added in the future to address a broader range of astigmatic conditions </li></ul>
  12. 14. ASICO instruments
  13. 15. Pre-op mark
  14. 16. Marking of the Eye – Axis Marking
  15. 17. Astigmatism SEC Holladay Data Base 0.916 D Average K astig 2.4% >/= 3 D 8.6% >/= 2 D 39% >/= 1 D n = 3538
  16. 18. Surgically induced astigmatism <ul><li>Holladay IOL Consultant </li></ul><ul><li>SIA = 0.13 (SD 0.39) </li></ul><ul><li>N = 41 </li></ul><ul><li>2.75 mm (pre implantation) temporal clear corneal wound </li></ul><ul><li>OD 180 ° OS 10° </li></ul><ul><li>No other incisions </li></ul>
  17. 19. Pre op: Toric vs. LRI N=55 N=75 -0.25 -0.25 aim 100% 96% cyl >/= 1 D 32% 21% cyl >/= 2 D 1.84 D 1.75 D Pre-op cyl SN60AT with LRIs n=55 Acrysof Toric n=75
  18. 20. Post op: Toric vs. LRI -0.575 -0.45 Mean SE 0.97 D 0.48 D Post-op refractive cyl 85% 93% >/= 6/12 24% 56% >/= 6/6 SN60AT + LRIs Acrysof Toric
  19. 21. SEC experience <ul><li>25.5% of cataract patients have a toric IOL </li></ul><ul><li>Over half are T3 </li></ul>56% T3 25% T5 19% T4
  20. 22. IOL rotation <ul><li>Follow-up: about a month later </li></ul><ul><li>n = 38 </li></ul><ul><li>Av = 2.66 (0 –7.5 °) </li></ul><ul><li>92% < 5 ° </li></ul><ul><li>Direction: equal clockwise and anticlockwise </li></ul>
  21. 23. Measuring axis post-op
  22. 24. Conclusion <ul><li>AcrySof ® Toric IOL </li></ul><ul><li>We can confirm that the lens has excellent rotational stability at 1 month </li></ul><ul><li>It handles just as easily as any AcrySof single piece lens </li></ul><ul><li>More reliable than spherical lens and LRIs in improving uncorrected distance visual acuity </li></ul>

×