  1. 1. www.kemltd.eu<br />Building Defect Investigation<br />Leak detection<br />Energy surveys & certification<br />Infrared/Thermal imaging surveys<br />
  2. 2. www.kemltd.eu<br />Damp investigation<br />Chelsea FC – leaking shower cubicles, not basement ground water as they thought<br />
  3. 3. www.kemltd.eu<br />Damp investigation<br />Water ingress from window only visible to the naked eye at ground level.<br />Client originally perceived problem to be ground level issue.<br />
  4. 4. www.kemltd.eu<br />Damp investigation<br />Rain water ingress proven by flourescein tracer dye flood testing. Dye evident in lift shaft.<br />
  5. 5. www.kemltd.eu<br />Damp investigation<br />Borescope inspection<br />
  6. 6. www.kemltd.eu<br />Damp investigation<br />Damp meters:<br /><ul><li>Resistance
  7. 7. Capacitance
  8. 8. Relative humidity</li></li></ul><li>www.kemltd.eu<br />Damp investigation<br />Salts analysis<br />Water analysis<br />
  9. 9. www.kemltd.eu<br />Defect investigation<br />Water ingress through roof covering defect<br />
  10. 10. www.kemltd.eu<br />Defect investigation<br />Render delamination<br />
  11. 11. www.kemltd.eu<br />Defect investigation<br />Covering bubbling<br />Screed break down<br />Flooring defects – services include UKAS laboratory sample testing<br />
  12. 12. www.kemltd.eu<br />Condensation<br />Thermal bridge from car park below creating condensation risk<br />
  13. 13. www.kemltd.eu<br />Condensation<br />Data logger shows dew point circa 20 degrees celcius, bottom of wall below dew point. Mould and damp evident.<br />
  14. 14. www.kemltd.eu<br />Leak detection<br />Door bar nail punctured heating pipe<br />
  15. 15. www.kemltd.eu<br />Leak detection<br />Poorly fitted radiator joint in floor<br />
  16. 16. www.kemltd.eu<br />Leak detection<br />Under floor heating leak<br />
  17. 17. www.kemltd.eu<br />Leak detection<br />Acoustic testing<br />
  18. 18. www.kemltd.eu<br />Insulation Continuity<br />Insulation removed to repair balcony defect, not reinstated<br />
  19. 19. www.kemltd.eu<br />Insulation Continuity<br />Floor slab thermal bridge in A1<br />
  20. 20. www.kemltd.eu<br />Insulation Continuity<br />Failure to install insulation in hipped roof<br />
  21. 21. www.kemltd.eu<br />Insulation Continuity<br />Missing insulation at eaves and light fitting<br />
  22. 22. www.kemltd.eu<br />Insulation Continuity<br />Missing insulation in conference centre bedroom<br />
  23. 23. www.kemltd.eu<br />Insulation Continuity<br />Thermal bridge due to air brick for ventilation to flat above<br />
  24. 24. www.kemltd.eu<br />Energy surveys& certification<br />DEC – Public buildings<br />EPC – Domestic & social housing<br />
  25. 25. www.kemltd.eu<br />Building Defect Investigation<br />Leak detection<br />Energy surveys & certification<br />Infrared/Thermal imaging surveys<br />

×