Summer Work

  1. 1. Brain Atlas Dan Diner
  2. 2. Introduction <ul><li>PET is a nuclear </li></ul><ul><li>imaging technique </li></ul><ul><li>A radiotracer is injected into subject, and the signal that it sends off is captured and measured to find out how much activity occurs and where </li></ul><ul><li>The information that is collected is used for brain study, and disorder analysis and diagnosis </li></ul>
  3. 3. ROI/VOI Mapping <ul><li>ROIs(Regions of Interest) are small regions mapped onto brains </li></ul><ul><li>Most common way of mapping is manual </li></ul><ul><li>Manual mapping is very time-consuming and requires highly-paid personnel (raters) </li></ul><ul><li>Raters have inter- and intra- subject variation </li></ul><ul><li>As PET scan quality increases, so does the time it takes for raters to do their job </li></ul>
  4. 4. <ul><li>PET has very poor spatial resolution </li></ul><ul><li>MRI has very high spatial resolution </li></ul><ul><li>ROIs are therefore mapped onto the MRI of a subject, onto which the PET scan is co-registered </li></ul>
  5. 5. MRI PET Co-Registered
  6. 6. Brain Atlases <ul><li>An “average brain” (co-registered PET/MRI) </li></ul><ul><li>Has all VOIs labeled manually onto it </li></ul><ul><li>These automated methods have been developed to label VOIs (Volumes of Interest) </li></ul><ul><li>Never have been as accurate as manual methods </li></ul><ul><li>Very precise - have no inter- or intra- subject variation </li></ul><ul><li>Take drastically less time to label a brain than manual methods </li></ul>
  7. 7. Brain Atlases <ul><li>Many imaging labs have their own, but we could not use another labs’ because each lab has different MRI acquisition and labeling techniques </li></ul><ul><li>Can be single- or multiple- subject template </li></ul><ul><li>Could be made for only one specific region or many </li></ul><ul><li>Probabilistic atlases tell you the probability of a certain voxel belonging to a certain ROI </li></ul>
  8. 8. Methods and M aterials: Subject and Image Acquisition <ul><li>MRIs and PETs from 176 subjects of past studies </li></ul><ul><li>123 from a 1.5 Tesla MRI </li></ul><ul><li>53 from a 3.0 Tesla </li></ul>
  9. 9. Image Analysis Setup <ul><li>Worked on a PowerMac G5 using Mac OS X 10.5.4 Leopard </li></ul><ul><li>Major Software used: </li></ul><ul><li>Matlab (R2007a) </li></ul><ul><li>FSLVIEW and FLIRT </li></ul><ul><li>ART </li></ul><ul><li>iView </li></ul>
  10. 10. Image Pre-Processing <ul><li>Raw MRI files were </li></ul><ul><li>copied to a common </li></ul><ul><li>folder </li></ul>
  11. 11. <ul><li>Previously made Gray Matter, </li></ul><ul><li>White Matter, and Cerebral Spinal Fluid Masks were multiplied(matrix multiplication) against the raw </li></ul><ul><li>files to get rid of all extraneous </li></ul><ul><li>material (neck, skull, dura matter) </li></ul>
  12. 14. <ul><li>Used iView to compare new images against raw ones </li></ul><ul><li>We did this to ensure that all extraneous material was gone and that no brain was accidentally segmented </li></ul><ul><li>I used a scale of 0-3 to rate the new images (0= perfect, 1=some dura, 2=much dura, 3=segmented brain) </li></ul><ul><li>Most images were 0s and 1s. </li></ul>
  13. 16. Normalization Procedure <ul><li>MNI template to which were were normalizing was reoriented towards raw MRI native space </li></ul><ul><li>New MRI images also normalized to this template </li></ul><ul><li>We examined the normalized images, and found that some were very well aligned, but others were misplaced or improperly warped </li></ul>
  14. 17. <ul><li>ART uses a 2-step process to warp MRIs: linear registration, then warp </li></ul><ul><li>Linear registration is rotations </li></ul><ul><li>Warping is dilations </li></ul><ul><li>Because the rotation was bad, we thought that the linear registration had gone wrong </li></ul><ul><li>We tried linear registration(first 9 Degrees of Freedom) with FLIRT, and then warping(up to 12 dof) with ART </li></ul>
  15. 18. <ul><li>The rotations came out looking good, but close inspection revealed that some leftover dura got warped into the new brain </li></ul>
  16. 19. <ul><li>An MRI with a particularly large amount of dura was manually cleaned, and then had FLIRT and ART run on it </li></ul><ul><li>The resulting image was perfect </li></ul>
  17. 20. Conclusion <ul><li>ART is very sensitive to extraneous material </li></ul><ul><li>all dura needs to be properly removed from all images before normalization </li></ul><ul><li>A better automatic method for cleaning up dura needs to be developed </li></ul>

×