Sysmex xe-5000

4,969 views

Published on

Published in: Health & Medicine
0 Comments
2 Likes
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total views
4,969
On SlideShare
0
From Embeds
0
Number of Embeds
10
Actions
Shares
0
Downloads
98
Comments
0
Likes
2
Embeds 0
No embeds

No notes for slide

Sysmex xe-5000

  1. 1. INTRODUCINGOUR NEWPRODUCT SYSMEX XE 5000
  2. 2. A BRIEF INTRODUCTION The Sysmex XE-5000 Automated Hematology System utilizes the power of fluorescent flow cytometry and hydrodynamic focusing technologies. Using a unique and advanced diode laser bench, Sysmex fluorescent flow cytometry provides the sensitivity needed for measuring and differentiating cell types in whole blood and body fluid samples. Fluorescent technology and hydrodynamic focusing enable the XE- 5000 to consistently differentiate normal WBC, RBC and PLT populations from abnormal populations, thereby decreasing the number of manual interventions. The XE-5000 technology provides clinically relevant and reportable parameters.
  3. 3. Reportable parameters 43 parameters•CBC (14 parameters) –WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MPV, P- LCR, PDW, PCT•DIFF (12 parameters)–NEUT%, LYMPH%, MONO%, EO%, BASO%, IG%, NEUT#, LYMPH#, MONO#,EO#, BASO#, IG#•NRBC (2 parameters)–NRBC%, NRBC#,•RET (8 Parameters)–RET%, RET#, LFR, MFR, HFR, IRF, RET-He, IPF, (PLT-O)•Body Fluid (6 parameters)–WBC-BF, RBC-BF, MN%, MN#, PMN%, PMN#-HPC
  4. 4. SPECIFICATIONSPrinciples & Technologies Fluorescent Flow Cytometry: WBC-Diff, IG, NRBC, RET, IRF, PLT-O RF-DC method: HPC DC-Sheath-Flow: PLT, RBC, HCT SLS-Method: HgbLinearity WBC: 0 – 440.00 x 103 /µL RBC: 0 – 8.00 x 106 /µL PLT: 0 – 5,000 x 103 /µLBody Fluid Linearity WBC-BF: 0.000 – 10.000 x 103 /µL TC-BF: 0.000 – 10.000 x 103 /µL RBC-BF: 0.000 – 5.000 x 106 /µL
  5. 5. SPECIFICATIONSThroughput Whole Blood Mode: 150 samples/hr (max.) Body Fluid Mode: 38 samples/hr (max.)Sample Volumes 200μL / 130μL (manual closed mode/open mode) 40μL for capillary modeData Storage 10,000 samples (incl. graphics)(IPU: Information Processing Unit)Interfaces Sysmex WAM (HL7 & ASTM)
  6. 6. SPECIFICATIONSQuality Control (Total QC Management) Levey-Jennings control chart X-bar M file Online QCDimensions / Weight Main unit: 27.8" x 35.9" x 28" / 178 lbs.w x h x d [in] / [lbs] Sampler: 22.8" x 7.7" x 14.8" / 26 lbs. IPU: 18" x 17.6" x 5.3" / 24 lbs.Configurations Stand alone Sysmex HST-N™, Sysmex XE-AlphaN™
  7. 7. TARGET CUSTOMER SUITABLE FOR LAB WHICH RECEIVES GREATER NUMBER OF SAMPLES PER DAY SUITABLE FOR LAB WITH LESS STAFFS AS OUR ANALYZER IS AUTOMATED AND REQUIRES LESS MANPOWER.
  8. 8. XE-5000 ANALYSIS PRINCIPLE •Laser Flow Cytometry •ShealthFlow/Hydrodynamic Focusing DC detection •RF/DC Detection Method •SLS Heamoglobin Method
  9. 9. FLUOROSCENCE FLOW CYTOMETRY
  10. 10. DC-HYDRODYNAMIC FOCUSING
  11. 11. XE-5OO0 MULTICHANNEL ANALYZER CHANNEL PRINCIPLE PARAMETERS WBC/BASO Flow cytometry WBC,Baso #, Baso NRBC Flow cytometry NRBC #, NRBC % 4 Diff Flow cytomtery Lymph# , Lymph% Mono#, Mono% Eo# , Eo% Neut# , Neut% IG# , IG% RET/PLT-O Flow cytometry RET#, RET%,PLT-O, HFR, MFR, LFR, IRF RET-He, IPF IMI RF/DC-detection HPC# method HGB SLS-Method, HGB photometry MCH,MCHC,MCV RBC/PLT-Detector HDF DC-Detection RBC,HCT,PLT-I,RDW- method SD, RDW-CV, PDW, MPV, P-LCR
  12. 12. REAGENT SYSTEM
  13. 13. OUTPUT
  14. 14. WHY SYSMEX XE-5000?? Integrated Sysmex SP-Series automated slide maker/stainer. eMM software provides more specific flagging. Measure body fluids. Advanced parameters
  15. 15. WHY SYSMEX XE-5000 ?• HIGH THROUGHOUTPUT• NO NEED OF SAMPLE PREPARATION• SHORTENED TURN AROUND TIME• REDUCED SAMPLE VOLUME• LESS LIKEHOOD OF TRANSCRIPTIONAL ERRORS• PROVIDES 7 SCATTERGRAMS AND 2 HISTOGRAM FOR A BETTER ANALYSIS RANKED BY THIRD PARTY AS HIGHEST VENDOR FOR RELIABILITY FOR 8 CONSECUTIVE YEARS IN A ROW*
  16. 16. CUSTOMER SERVICE• In-time deliveries of reagents and consumable• Instrument repair and maintenance including hot-line support• Consultancy and management of complex laboratory installation projects• Continuous post-market surveillance and feedback of market requirements as design input for new product development• Management of customer events

×