  1. 1. OnSite SE Network Configuration Console Guide Document Number: ENG-DOC-105 October 22, 2007
  2. 2. Legal Disclaimers Canada-Underwriters Laboratories (C-UL) Compliancy For C-UL Listed applications, the unit shall be installed in accordance with Part 1 of the Canadian Electrical Code. Documentation Disclaimer and Restrictions Information in this document is subject to change without notice and does not represent a commitment on the part of Brivo Systems, LLC. For the most up-to-date information, visit www.brivo.com . HHHU UH This document and the data herein shall not be duplicated, used or disclosed to others for procurement or manufacturing, except as authorized with the written permission of Brivo Systems, LLC. The information contained within this document or within the product itself is considered the exclusive property of Brivo Systems, LLC. All information in this document or within the hardware and software product themselves is protected by the copyright and/or other intellectual property laws of the United States. Product Support All support for this product is provided by the third-party dealer. Please contact the dealer who installed the product with questions and support requests. © 2007 Brivo Systems, LLC. All rights reserved. Brivo® is a registered trademark of Brivo Systems, LLC. Brivo Systems, LLC, 4330 East West Highway, Suite 250, Bethesda, MD 20814.
  3. 3. Page 3 OnSite SE Network Configuration Console Guide Table of Contents Table of Figures ............................................................................................................................................. 4 Logging In ...................................................................................................................................................... 6 Main Menu......................................................................................................................................................7 Network Status .............................................................................................................................................. 8 Networking Settings ...................................................................................................................................... 9 To set a static IP address:.............................................................................................................................. 9 View System Log ...........................................................................................................................................10 To view the system log: ................................................................................................................................10 Set Console Password .................................................................................................................................. 11 To set or change the console password:...................................................................................................... 11 Reset Database to Factory Default ............................................................................................................... 12 To erase all application data on the appliance: ........................................................................................... 12 © 2007 Brivo Systems, LLC. All rights reserved. 10/22/2007
  4. 4. Page 4 OnSite SE Network Configuration Console Guide Table of Figures Figure 1. Console main menu......................................................................................................................7 Figure 2. Network status information ........................................................................................................ 8 Figure 3. Network Settings dialog for entering static IP address .............................................................. 9 Figure 4. View system log ..........................................................................................................................10 Figure 5. Set console password ................................................................................................................. 11 Figure 6. Reset database ............................................................................................................................ 12 © 2007 Brivo Systems, LLC. All rights reserved. 10/22/2007
  5. 5. Page 5 OnSite SE Network Configuration Console Guide Onsite SE Network Configuration Console OnSite SE has a console interface for configuring the network. This is useful for both initial set up of the appliance as well as for changes to the network configuration in the future. The interface is designed more or less as a way to bring the system to a point where the main OnSite SE application is accessible from a browser. © 2007 Brivo Systems, LLC. All rights reserved. 10/22/2007
  6. 6. Page 6 OnSite SE Network Configuration Console Guide Logging In To access the console interface, you must connect a monitor and keyboard to the OnSite SE appliance. Log in with the username admin and the password set for the initial administrator created the first time the web interface is accessed. If the web interface has not been accessed, thus no administrator has been configured; the admin user has no password. Simply press “Enter” when prompted for a password. © 2007 Brivo Systems, LLC. All rights reserved. 10/22/2007
  7. 7. Page 7 OnSite SE Network Configuration Console Guide Main Menu The console main menu allows the selection of various network-related options. Figure 1. Console main menu Simply select an option from the list and press “Enter” to proceed. © 2007 Brivo Systems, LLC. All rights reserved. 10/22/2007
  8. 8. Page 8 OnSite SE Network Configuration Console Guide Network Status The network status page contains current networking information, including current interfaces and settings, DNS configuration and any active routes. Figure 2. Network status information © 2007 Brivo Systems, LLC. All rights reserved. 10/22/2007
  9. 9. Page 9 OnSite SE Network Configuration Console Guide Networking Settings It is generally necessary to configure a static IP address for the OnSite SE appliance. The Network Settings dialog prompts for static address parameters. Figure 3. Network Settings dialog for entering static IP address NOTE:  If DHCP is required, please use the initial static IP address for the appliance to log into the main application and select DHCP addressing. To set a static IP address: 1. Select Network Settings from the main menu 2. Enter the appropriate IP address information 3. Press Enter to save settings © 2007 Brivo Systems, LLC. All rights reserved. 10/22/2007
  10. 10. Page 10 OnSite SE Network Configuration Console Guide View System Log The system log contains output from various processes, including information useful in configuring and diagnosing networking settings. Figure 4. View system log To view the system log: 1. Select View system log from main menu. The View system log page displays 2. Press “Enter” to return to the main menu. © 2007 Brivo Systems, LLC. All rights reserved. 10/22/2007
  11. 11. Page 11 OnSite SE Network Configuration Console Guide Set Console Password The initial console password is set from the value entered as the initial administrator login password. Thus there is no “default” password. After it is initially set, however, the console password must be changed through the console interface. Figure 5. Set console password To set or change the console password: 1. Select Set console password from the main menu. The New Console Password screen displays. 2. Enter the new password in the given field.  NOTE: Input does not echo for security reasons. 3. Enter the new password again in the Confirmation field to ensure accuracy.  NOTE: Input does not echo for security reasons. 4. Press 'Enter' to save and return to the main page. © 2007 Brivo Systems, LLC. All rights reserved. 10/22/2007
  12. 12. Page 12 OnSite SE Network Configuration Console Guide Reset Database to Factory Default It is occasionally necessary to simply reset the data on an OnSite SE appliance back to factory defaults. This will erase all account data and activity generated by the OnSite SE application. WARNING: This will erase all users, cards, schedules, holidays, devices and all event data from the system. The only way to get the data back is to restore from a backup. Figure 6. Reset database To erase all application data on the appliance: Select Reset database to factory default from the main menu. The ERASE ALL DATA screen displays. Read the warning – if this is really what you want to do, you must type 'Yes' at the prompt and press “Enter” to continue. All data will be erased. The “Quit” option exits the application and returns to a “login” prompt. © 2007 Brivo Systems, LLC. All rights reserved. 10/22/2007

×