Introduction to
Sewerage Network Design
Presented by Mazhar Alam
Basic Definitions
• Sewage
• Sewer
• Sewerage
Basic Definitions
Sewage
It is mainly liquid waste containing some
solids produced by humans and
industry. Foul water , wa...
Basic Definitions
Sewer
An artificial conduit (or pipe) or system
of conduits used to convey sewage
from source to sewage ...
Basic Definitions
Sewerage
The system of sewers that conveys
wastewater (sewage) to a treatment
plant or disposal point.
I...
Design of Sewerage Network
Information Required
•Design Criteria
•Master Plan Layout Drawing
•Levels
Design of Sewerage Network
Design Criteria
It describes the parameters to be used in
design;
•Sewage generated per person
...
Design of Sewerage Network
Sewage generated per person
It depends on the type of occupancy or
land use details of the faci...
Design of Sewerage Network
Min. , Max., Proportional velocity
Min. velocity is normally 0.75m/s at full
capacity to allow ...
Design of Sewerage Network
Minimum slopes
For a given diameter and roughness
minimum slope is required to achieve min.
vel...
Design of Sewerage Network
Peaking Factor
Babbitt A/(P)^B ( A=0.176,B=5.096)
Abu Dhabi (18+sqrt(P))/(4+sqrt(P))
Harman 1+(...
Design of Sewerage Network
Pipe dias & material
In the UAE
Minimum pipe dia is 200mm for main line
and
150mm for house con...
Design of Sewerage Network
Minimum backdrop height
•Avoid direct fall
•Splashing
•Erosion of benching
•Smooth transition
•...
Design of Sewerage Network
Master Plan Layout Drawing
•Plot – types and land use details
•Road corridor – ROW for services...
Design of Sewerage Network
Levels
•Spot Levels
•Contours
•Finished Road Levels
Design of Sewerage Network
Steps in design
• Marking the network on layout.
• Calculating the population
• Hydraulic desig...
Design of Sewerage Network
Steps in design
Marking the network on layout.
• Gravitating the network
• House connection cha...
Design of Sewerage Network
Steps in design
Population calculations.
• Type of plot single storey or multi rise.
• Type of ...
Design of Sewerage Network
Steps in design
Hydraulic design.
• Spread sheet - Excel
• Software – WinDes, PipeMate, Sewer
C...
Design of Sewerage Network
Steps in design
Final presentation drawings.
To show pipe dias, invert level, cover
levels, man...
LINE DIAGRAM- SEWAGE NETROWK
Phase III
• Commissioned in 1993
• The Works provided an additional capacity of 25700 m3
/d
• Client : • Sharjah Municipal...
3D VIEW - WINDES
3D VIEW - WINDES
MANHOLE SCHEDULE – WINDES OUTPUT
LOND SECTION - WINDES
Questions
Sewerage network
Sewerage network
Sewerage network
Upcoming SlideShare
Loading in …5
×

Sewerage network

570 views

Published on

civil engineer

Published in: Engineering
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
570
On SlideShare
0
From Embeds
0
Number of Embeds
3
Actions
Shares
0
Downloads
34
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Sewerage network

  1. 1. Introduction to Sewerage Network Design Presented by Mazhar Alam
  2. 2. Basic Definitions • Sewage • Sewer • Sewerage
  3. 3. Basic Definitions Sewage It is mainly liquid waste containing some solids produced by humans and industry. Foul water , waste water. Grey water-Non faecal. From washing Black water-Contains faecal matter. It needs full treatment.
  4. 4. Basic Definitions Sewer An artificial conduit (or pipe) or system of conduits used to convey sewage from source to sewage treatment facility.
  5. 5. Basic Definitions Sewerage The system of sewers that conveys wastewater (sewage) to a treatment plant or disposal point. It includes all the chambers, manholes, gravity mains, pumps, rising mains, air valves, washouts etc
  6. 6. Design of Sewerage Network Information Required •Design Criteria •Master Plan Layout Drawing •Levels
  7. 7. Design of Sewerage Network Design Criteria It describes the parameters to be used in design; •Sewage generated per person •Minimum, maximum & proportional velocity •Minimum slopes •Peaking factors •Pipe diameters and material etc •Minimum Backdrop height.
  8. 8. Design of Sewerage Network Sewage generated per person It depends on the type of occupancy or land use details of the facility to be served. e.g. residential, commercial, recreational. Qasr Al Sarab sewage generated from villas - 275 l/p/d Hotels – 298 l/p/d
  9. 9. Design of Sewerage Network Min. , Max., Proportional velocity Min. velocity is normally 0.75m/s at full capacity to allow for self cleaning. Max. velocity is 2.5 to 3.0m/s. Proportional velocity is the actual velocity at given flow. 0.6m/s
  10. 10. Design of Sewerage Network Minimum slopes For a given diameter and roughness minimum slope is required to achieve min. velocity. Dependent on the pipe diameter and roughness e.g. for dia=200 and k=0.6 the minimum slope is 1:240. For lager dias the minimum slope is 1:1000
  11. 11. Design of Sewerage Network Peaking Factor Babbitt A/(P)^B ( A=0.176,B=5.096) Abu Dhabi (18+sqrt(P))/(4+sqrt(P)) Harman 1+(14/(4+sqrt(P))
  12. 12. Design of Sewerage Network Pipe dias & material In the UAE Minimum pipe dia is 200mm for main line and 150mm for house connection pipe. Material; uPVC – for smaller dias GRP – for larger dias
  13. 13. Design of Sewerage Network Minimum backdrop height •Avoid direct fall •Splashing •Erosion of benching •Smooth transition •Minimum value. 600mm to 700mm
  14. 14. Design of Sewerage Network Master Plan Layout Drawing •Plot – types and land use details •Road corridor – ROW for services •Location of STP or final disposal point
  15. 15. Design of Sewerage Network Levels •Spot Levels •Contours •Finished Road Levels
  16. 16. Design of Sewerage Network Steps in design • Marking the network on layout. • Calculating the population • Hydraulic design • Final presentation drawings.
  17. 17. Design of Sewerage Network Steps in design Marking the network on layout. • Gravitating the network • House connection chambers- at each plot • Manholes- maximum spacing • Angle b/w incoming & outgoing sewer. • Max. no. of connections to a manhole.
  18. 18. Design of Sewerage Network Steps in design Population calculations. • Type of plot single storey or multi rise. • Type of occupancy i.e. villa, hotel, office, school, restaurant etc. • Equivalent population.
  19. 19. Design of Sewerage Network Steps in design Hydraulic design. • Spread sheet - Excel • Software – WinDes, PipeMate, Sewer CAD.
  20. 20. Design of Sewerage Network Steps in design Final presentation drawings. To show pipe dias, invert level, cover levels, manhole types etc. • Manhole schedule • Layout drawings
  21. 21. LINE DIAGRAM- SEWAGE NETROWK
  22. 22. Phase III • Commissioned in 1993 • The Works provided an additional capacity of 25700 m3 /d • Client : • Sharjah Municipality Drainage Section (SMDS) • Civil Contractor: • Six Construct • PM /M&E RE : • Consultant : • M&E Contractor: • PCL • Halcrow • Martin Davis • Civil RE : • Stephen Smythe LINE DIAGRAM- SEWAGE NETROWK
  23. 23. 3D VIEW - WINDES
  24. 24. 3D VIEW - WINDES
  25. 25. MANHOLE SCHEDULE – WINDES OUTPUT
  26. 26. LOND SECTION - WINDES
  27. 27. Questions

×