Flex Pod Solution

3,742 views

Published on

That\'s why NetApp and Cisco have collaborated to create FlexPod™ for VMware. FlexPod consists of networking, storage, and infrastructure software components.

Putting the Flexpod inside an Elliptical container makes FlexPod a pre-validated data center solution built on a flexible, shared infrastructure that can scale easily, be optimized for a variety of mixed application and workloads.

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
3,742
On SlideShare
0
From Embeds
0
Number of Embeds
8
Actions
Shares
0
Downloads
90
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Flex Pod Solution

  1. 1. ELLIPTICAL MOBILE SOLUTIONS Flex Pod in a Micro-Modular Data Center <ul><li>One Flexible Infrastructure to fit your specific requirements with: </li></ul><ul><li>Lower risk with simplified, pre-validated, shared architecture </li></ul><ul><li>Flexible IT scalable for today's needs, and ready for future growth </li></ul><ul><li>Reduced TCO with better efficiencies </li></ul><ul><li>Authorized data center partners and Support </li></ul>
  2. 2. Overview Three Industry Leaders One Architecture… FlexPod
  3. 3. <ul><li>FLEX POD SOLUTION </li></ul><ul><li>Targeted at applications requiring 1,000 to 2,000 users to be supported from a virtualized server. </li></ul><ul><li>Features include - </li></ul><ul><li>Performance-matched stack </li></ul><ul><li>Support for multiple classes of compute and storage in a single FlexPod deployment </li></ul><ul><li>Centralized management: VMware vCenter with Cisco Unified Computing System and NetApp FAS plug-ins </li></ul><ul><li>Elliptical Infrastructure Features </li></ul><ul><li>Built in High Density Cooling, Fire Suppression and Security </li></ul><ul><li>Deployable in almost any location with Elliptical Mobile Solutions </li></ul>Copyright Elliptical Mobile Solutions 2010 www.ellipticalmobilesolutions.com
  4. 4. 42U Hardened, Portable and Energy Efficient Solution FlexPod™ for VMware - Unified, pretested, and validated shared infrastructure to simplify your data center transformation That's why NetApp and Cisco have collaborated to create FlexPod™ for VMware. FlexPod consists of networking, storage, and infrastructure software components. Putting the Flexpod inside an Elliptical container makes FlexPod a pre-validated data center solution built on a flexible, shared infrastructure that can scale easily, be optimized for a variety of mixed application and workloads.
  5. 5. FlexPod Key Components <ul><li>Flex Pod Cisco Unified Computing System Components </li></ul><ul><li>Cisco UCS B250 M2 Extended Memory Blade Server 9 with 192GB of RAM each </li></ul><ul><li>Cisco UCS B200 M2 Blade Server 6 with 48GB of RAM each </li></ul><ul><li>Number of CPUs 30 Intel® 3.33GHz Xeon™ X5680 6-core CPUs </li></ul><ul><li>Total CPU cores 180 </li></ul><ul><li>Total RAM 2 terabytes (TB) </li></ul><ul><li>FCoE bandwidth (Servers to fabric) 120Gbps: 12X 10 Gigabit Ethernet </li></ul><ul><li>Ethernet uplink bandwidth 40Gbps: 4X 10 Gigabit Ethernet </li></ul><ul><li>Fibre Channel uplink bandwidth 16Gbps: 4X 4Gbps </li></ul><ul><li>Number of blade chassis 3 Cisco UCS 5108 Blade Server Chassis </li></ul><ul><li>Flex Pod Fabric (2 Cisco Nexus® 5548P Switches) – Port counts in use </li></ul><ul><li>10 Gigabit Ethernet ports 80Gbps: 8X 10 Gigabit Ethernet </li></ul><ul><li>Fibre Channel ports 32Gbps: 8X 4Gbps </li></ul><ul><li>FlexPod Array (NetApp FAS3210A) </li></ul><ul><li>RAM 8GB </li></ul><ul><li>NVRAM 1GB </li></ul><ul><li>Number of SAS drives 96 with 450GB each </li></ul><ul><li>Number of disk shelves 4 </li></ul><ul><li>Total storage 42TB </li></ul><ul><li>10 Gigabit Ethernet bandwidth 40Gbps: 4X 10 Gigabit Ethernet </li></ul><ul><li>Fibre Channel bandwidth 16Gbps: 4X 4Gbps </li></ul><ul><li>PAM-II flash memory cache 512GB:2X 256GB cards </li></ul>
  6. 6. Flexibility
  7. 7. <ul><li>Infrastructure and Cooling </li></ul><ul><li>Elliptical Infrastructure Features </li></ul><ul><li>Built in “Future Proof” High Density Cooling </li></ul><ul><li>Reduce cooling cost by 50% using closed loop system </li></ul><ul><li>Reduce additional build out cost by 80% </li></ul><ul><li>Fire Suppression </li></ul><ul><li>Security </li></ul><ul><li>Deployable in almost any location </li></ul><ul><li>Mobility </li></ul>Copyright Elliptical Mobile Solutions 2010 www.ellipticalmobilesolutions.com
  8. 8. RASER COOLING Cold Air <ul><li>Closed Loop Systems allows </li></ul><ul><li>location Flexibility </li></ul><ul><li>Cooling directly to IT and </li></ul><ul><li>Eliminates Hot spots </li></ul><ul><li>Scalable from 1-100’s of </li></ul><ul><li>Units </li></ul><ul><li>Temperature control within </li></ul><ul><li>the rack </li></ul>HVAC <ul><li>- Field-based repair for warranty and non-warranty parts </li></ul><ul><li>- On-call availability </li></ul><ul><li>- Emergency response available worldwide within 24-48 hours within Service Coverage Area. </li></ul><ul><li>Repair centers and certified technicians worldwide </li></ul><ul><li>This is the Elliptical commitment to protecting you and your electronics. </li></ul><ul><li>BUILT IN COOLING </li></ul><ul><ul><li>12KW IT LOAD </li></ul></ul><ul><ul><li>42,000 BTU </li></ul></ul>Equipment Equipment Equipment Equipment
  9. 9. 11” 80” Cabinet 43” 30” 82 ” Side View Front View 26” RASER DIMENSIONS HVAC
  10. 10. <ul><li>Firetrace Systems provide Cost-Effective, Stand-Alone, Automatic Fire Suppression Systems for Critical Equipment </li></ul><ul><li>Novaec 1230 is a dielectric substance which is harmless to electronic equipment even during operation . </li></ul><ul><li>Novaec 1230 is a totally “clean” (non toxic) agent which eliminates permitting issues and eliminates clean up. </li></ul><ul><li>A Firetrace System can be utilized anywhere that a fire poses a risk,  and it is flexible enough for virtually any Industrial Equipment. </li></ul><ul><li>SMTP Remote Monitoring </li></ul>Active Fire Suppression System 3M™ Novec™ 1230 Fluid 150,000 units installed worldwide
  11. 11. Fire Proofing Insulation <ul><li>Aerogel Insulation provides thermal protection from external or internal sources </li></ul><ul><li>Air Tight RASER does not support combustion. </li></ul>Fires in the data center typically initiate through electrical equipment or component failure…”- Lance Harry, business development manager for Fenwal Protection Systems Self contained modules compartmentalize damage to overall Data Center environment.
  12. 12. <ul><li>Fully Customizable Encrypted Security Access </li></ul><ul><ul><li>Limitation by time or day (9am – 5pm) </li></ul></ul><ul><ul><li>Limitation by personnel (Network Equipment Only or Servers Only) </li></ul></ul><ul><ul><li>Monthly Expiration and Renewal </li></ul></ul><ul><li>4,000 user event auditable trail – Track who opens what and when. </li></ul>CyberLock Multi-tier Security System Integrated electronic security Copyright Elliptical Mobile Solutions 2010 www.ellipticalmobilesolutions.com Field Programmable
  13. 13. Inside View
  14. 14. Expand Data Center Capacity with Energy Efficient High Density Zone Support up to 2,000 users from day one and scale to 10,000 users as future needs arise. “ EXAMPLE SOLUTION” 2,000 Users 42 TB “ Future Growth” 4,000 additional users 84 TB of additional storage CISCO UCS Blade Servers NETAPP STORAGE
  15. 15. <ul><li>Convert any location into A high density Zone </li></ul><ul><li>Streamline Project Management </li></ul><ul><li>Reduce Installation & Design Costs </li></ul><ul><li>Total Project finished in 10 weeks or less </li></ul>“ Future Growth” 15KW TOTAL POWER DRAW “Typical” IT = 9 KW A/C = 6 KW TOTAL 15 KW 9 KW IT 6 KW A/C 9 KW IT 6 KW A/C 9 KW IT 6 KW A/C A PUE of 1.5 with an Average operating cost per year of *$13,140 *US average 10cents per KW hourx15kw x24 x365 PUE - power usage effectiveness 30 KW TCO for initial Cost and Power over 10 years $181,400
  16. 16. Information www.EllipticalMobileSolutions.com www.netapp.com/us/technology/flexpod www.cisco.com www.wwt.com Contact: Justin Bell Elliptical Mobile Solutions 480-924-0547 [email_address]

×