KPI & KP
Type KP and KPI pressure switches
o
o
o
o
o
o
o
o

Technical data

Compact design
Ideal for panel mounting
Vibrat...
Dimensions and weight

14
Weight = 0.3 kg

Accessories
Part

Quantity
per set

Code No.

Wall bracket for KP
Brackets with...
Upcoming SlideShare
Loading in …5
×

ตารางเปรียบเทียบ Danfoss Model KP และ KPi

754 views

Published on

Danfoss KP สำหรับงานธรรมดาทั่วไป
Danfoss KPi สำหรับงานที่มีสารเคมี

ติดต่อ บริษัท นิวเมติก ดอทคอม (ประเทศไทย) จำกัด
www.นิวเมติก.com/danfoss-pressure-switches-pressure-control/

Published in: Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
754
On SlideShare
0
From Embeds
0
Number of Embeds
3
Actions
Shares
0
Downloads
2
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

ตารางเปรียบเทียบ Danfoss Model KP และ KPi

  1. 1. KPI & KP Type KP and KPI pressure switches o o o o o o o o Technical data Compact design Ideal for panel mounting Vibration proof Long operation life High contact load Ultra short bounce times High pulsation protection CE marked in accordance to EN 60947-4/-5 KPI KP Media: Liquid and gases Gases (for liquids please contact Danfoss) Media temperature: -40ºC to 100ºC -40ºC to 100ºC Ambient temperature: -40ºC to 65ºC (reduced life up to 80°C) -40ºC to 65ºC (reduced life up to 80ºC) Enclosure: IP30; with top cover or protection cap: IP44 IP30; with top cover or protection cap: IP44 Electrical connection: Cable entry for diameters 6 mm to 14 mm Cable entry for diameters 6 mm to 14 mm Contact system: SPDT SPDT Contact load: AC-1 Ohmic: 10 A, 440 V 16 A, 400 V AC-3 (motor) 6 A, 440 V 16 A, 400 V AC14/15 (coil/transformer) For more information: 4 A, 440 V 10 A, 400 V DC-13/14 12 W, 220 V 12 W, 220 V See Datasheet DKACT.PD.P10.F Ordering – KPI, for liquids and gases Setting range (rising pressure) (bar) -0.2 to 8 -0.2 to 8 4 to 12 2 to 12 8 to 28 Adjustable differential (bar) 0.4 to 1.5 0.5 to 2 0.5 to 1.6 0.5 to 1.6 1.8 to 6 Permissible operating pressure (bar) 18 18 18 18 30 Pressure connection G1⁄4”A G1⁄4”A G1⁄4”A G1⁄4”A G1⁄4”A Type KPI KPI KPI KPI KPI 35 35 36 36 38 Code No. 060-1217 060-1219 060-1189 060-3169 060-5081 Ordering – KP, for gases (and water on a direct connection only – do not use capillary mounting) -0.2 to 7.5 -0.2 to 7.5 2 to 14 2 to 14 4 to 12 4 to 12 0.7 0.7 0.7 0.7 0.5 0.5 to to to to to to 4.0 4.0 4.0 4.0 1.6 1.6 17 17 17 17 17 17 * KP with gold plated contacts (use contact load specification of KPI) G1⁄4”A G1⁄4”A G1⁄4”A G1⁄4”A G1⁄4”A G1⁄4”A KP KP KP KP KP KP 35 35 36 36 36 36 060-1133 060-5047* 060-1108 060-1137* 060-1221 060-1144*
  2. 2. Dimensions and weight 14 Weight = 0.3 kg Accessories Part Quantity per set Code No. Wall bracket for KP Brackets with mounting screws and washers Description 10 060-1055 Angle bracket for KP (not recommended for areas where vibrations occur) 10 060-1056 1 060-1054 5 060-1059 10 060-1097 7 060-0031 20 060-1057 4-off screws M4x5 + 4-off washers Cable entry Top cover Protective cap Sealing screw For pressure connection adaptors see page 56 Screwed cable entry Pg 13.5 with special nut. For 6-14 mm cables. A standard Pg 16 screwed cable entry can be used for 6-18 mm cables. If a bracket is mounted on the backplate of the housing, the KP pressure control will have an IP 44 grade of enclosure. The cover covers the setting spindles. Protective cap for KP pressure controls. To protect the unit against rain and humidity. Grade of enclosure: IP44 Material: Polyethylene Max. ambient temperature: +65ºC Min. ambient temperature: -40ºC For sealing the setting on KP only

×