Micro-Modular Data Center infrastructure

  1. 1. ELLIPTICAL MOBILE SOLUTIONS, LLCSave Money, Energy Time and Space
  2. 2. Today’s Data Centre ChallengesDigital Explosion Worldwide:Aging Infrastructure:Rising Energy Use:Costs Are Out of Control:
  3. 3. How much electricity would you waste if you cooled your house just to keep the milk cool? =Patented “Closed Loop Cooling” from EMSbrings up to 50%+ Electricity Savings
  4. 4. Industry Change – Containerized Data Centres = Less Capital $ More EfficientAverage Data Centre PUE 2.5 Containerized Data Centres PUE 1.1-1.5$/Kilowatt of IT: 25,000-15,000 $/Kilowatt of IT: 8,000-4,000Brick & Mortar Container MMDC
  5. 5. Resilient Data Centre Infrastructure PlatformEMS Standardized Infrastructure Provides Multi Tier Cross Purpose Disaster Infrastructure Solutions
  6. 6. MMDC Cooling Efficiency Characteristics • “Best Practice” airflow “forces” most efficient method • Pre Engineered – No airflow analysis required • Hot Aisle Containment – No remixing of hot air into servers • Cold Aisle Containment – Delivers 100% of cold air to equipment intake • Zero Bypass Airflow – Cold air is forced through equipmentData Centre Equipment Equipment Equipment Equipment Equipment Cold Air “Raised Floor”
  7. 7. Reduce “Embodied Carbon” by 60%• Reduced complexity of data centre facilities construction • Results in less embodied carbon in building shell • Enables renewable material choices • Reduced “embodied pollution” of construction process • “ Cradle to Grave” MMDC is all steel and portable and can be reused in other locations or recycled at end of life Recyclable Brick and Mortar Asset Containerized Building Shell 100% 80% 60% 40% 20% 0%
  8. 8. MMDC: Scalable, Mobile Footprint = Less Environmental Impact2MW Brick & Mortar Semi Permanent 2MW Containerized 500 KW Container 500 KW Container 500 KW Container 500 KW Container Permanent2000 KW Data Centre Portable 2MW MMDC (Containerized) Facility = Data Centre Size 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 4 4 4 4 4 4 4 4 4 4 4 4 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 4 4 4 4 4 4 4 4 4 4 4 0 0 0 0 0 0 0 0 0 0 0 0
  9. 9. Practical Applications R.A.S.E.R. DXR.A.S.E.R. HD C3-S.P.E.A.R. New Data Center & Data Center • Disaster Consolidation Recovery • HPC • Remote Office • Cloud Computing • IT on the Move • High Density Zone • Telco • Expansions • Industrial
  10. 10. R.A.S.E.R. DX Features Compressor Condenser/ Evaporator• Built-in cooling • 12KW IT load • 42,000 BTU Equipment C • Vapor cycle “DX” H o o l• Shock and vibration isolation t d• Hardened enclosure Equipment A A i i• Scalable and modular Equipment s s l l• Self-contained e e Equipment• Mission Critical Venting (Optional) Cold Air
  11. 11. Portable Cloud Computing (Example Solution) Three Industry Leaders One Architecture…
  12. 12. Expand Data Centre Capacity with Energy Efficient High Density Zone “EXAMPLE SOLUTION” “Future Growth”Blade ServersSTORAGE
  13. 13. R.A.S.E.R. HD Features • 42U of rack space available in the main• Redundant (N+1 AND 2N), hot swappable cabinet • heat exchanger units exchanger (HX) 2 “sidecars” contain heat units• 42U of rack space available in the main • cabinet environment Sealed• • 2Close coupled contain heat high “sidecars” cooling allows exchanger (HX) temperature water units • A / B water loops and multiple hot-• Sealed environment swappable fans• • Close coupled cooling allows high NEMA 4 environmental package temperature water • Redundant (N+1 AND 2N), hot swappable• Aheat water loops and multiple hot- / B exchanger units • swappable fans Multiple configurations starting at 20 KW and growing to 80 KW in a single enclosure• Multiple configurations starting at 20 KW
  14. 14. C³SPEAR Features• 24U of blade ready space• 2 Self contained close coupled cooling units support N+1 or 2N closed loop cooling. • 2.5KW, redundant 2N • 6KW, redundant N+1• Power assisted mobility• NEMA 12 or Option NEMA 4 environmental package• A/B power input for IT• A/B power input for cooling• Custom interconnections available • Waterproof • Shielded• Shock and vibration isolation
  15. 15. Available Options On All Active Fire Suppression System • VESDA • HSSD • NOVEC 1230 • F-GAS Cyber Lock Security System • Stand alone power • 4,000 user event audit trail • Card reader security interface • Enterprise class software • Remote programability Shock and Vibration Isolation • Protects Equipment while being moved or relocated • Disaster Tolerant
  16. 16. Data Centre Challenges Today Problems SolvedTechnology Refresh Limited Cooling/ Electrical CapacityData Centre Consolidation Runaway Electrical Bill CostEnergy Saving Initiatives Expensive Retrofit for High Density ZoneExpensive Build Cost Constant Demand for ExpansionFloor Space Constraints Under Utilized Compute ResourcesInflexible Infrastructure Virtualization Infrastructure Challenges •Up To 50% $ Savings on Electricity •Patented zero bypass cooling system •50-80% More efficient = Green •Up To 75% Floor Area Savings •25 ft² for EMS enclosures vs. 100 ft² traditional raised floor •Fireproof and Water Proof •Air Tight Closed Loop System •Eliminates Shock and Vibration Damage •Patented Equipment Suspension •Scalable from 1 Micro Data Centre to 100’s; “Pay as You Need” •Purchase cooling, security, fireproofing, raised floor, hot and cold isle
  17. 17. Micro Modular Data Centres ELLIPTICAL MOBILE SOLUTIONS, LLC• Save Money – Eliminate costly infrastructure with a self-contained, high-density, cost-effective and energy efficient data centre. – Reduce the costs to plan, build and implement your data centre – Reduce overall operating expenses• Save Energy – Patented closed loop cooling dramatically cuts cooling and electrical costs – Significantly reduce data centre’s harmful carbon footprint• Save Time – Micro-Modular Data Centre’s can be built, fully populated and delivered in weeks vs. months or years – Have a fully functional data centre when, where and for however long you need it• Save Space – Reduce your data centre footprint by up to 70 percent – EMS products can be located in a warehouse, garage, office or closet

×