Successfully reported this slideshow.
We use your LinkedIn profile and activity data to personalize ads and to show you more relevant ads. You can change your ad preferences anytime.
1
Physical Activity and
Leisure Management Ltd
POOL PLANT OPERATIONS
INFORMATION UPDATE SEMINAR
(on-line option)
1Carlton ...
2
Physical Activity and
Leisure Management Ltd
Module 3
Current Trends in Filtration and
Mechanical Services
2Carlton Asso...
33Carlton Associates Ltd (c) 2013
This module explores alternative
Filter Media; automated
backwashing and recommended
set...
4
• What is Happening to our
Mechanical Systems
• Link Between Backwashing, Filter
Efficiency and Cryptosporidiosis
• Coag...
5
5
What’s happening to our
mechanical systems?
 Not very exciting, as these are not always in
areas that are seen by the...
6
6
This can’t be right ………….. can it??
6
7
7
ANTI-VORTEX OUTLET GRILLES
……… are now a requirement, if there is a risk
of vacuum formation.
Courtesy of Sterling Hyd...
8
8
“MUDBALLING” INSIDE A FILTER
9
9
Replacement Filter Media
Imploded Glass Media
Leighton Buzzard
Sand Media
9
10
THE LINK BETWEEN BACKWASHING; FILTER
EFFICIENCY AND CRYPTOSPORIDIOSIS
Unless Ultra-Violet Light or Ozone are used,
the ...
11
11
Coagulation:
A filter type WITHOUT the
addition of a coagulant has the
ability to filter particles down
to a particu...
12
BACKWASHING REGIMES
 The process of backwashing fluidises the filter
bed, as the compressed media is broken up by
reve...
13
BACKWASHING REGIMES
 Consequently, during the ripening period, the
filter media is less efficient than it should be,
a...
14
14
ULTRAVIOLET
RADIATION
15
15
Swimming Pool
Balance
Tank
Strainers
Circulating
Pump
Chemical
Measurement
Coagulant
Dosing
Medium Rate
Sand Filter
...
How does it work?
 Pool water is still filtered, but is then pass through a sealed
stainless steel unit that houses the U...
17
Carlton Associates Ltd (c) 2013
That is the end of Module 3
What you need to do now:
1. Return to the course page
2. Downl...
Carlton Associates Ltd (c) 2013
End of Module 3 Presentation
Upcoming SlideShare
Loading in …5
×

Current Trends in Filtration and Mechanical Services

1,720 views

Published on

Published in: Technology, Business
  • Be the first to comment

Current Trends in Filtration and Mechanical Services

  1. 1. 1 Physical Activity and Leisure Management Ltd POOL PLANT OPERATIONS INFORMATION UPDATE SEMINAR (on-line option) 1Carlton Associates Ltd (c) 2013
  2. 2. 2 Physical Activity and Leisure Management Ltd Module 3 Current Trends in Filtration and Mechanical Services 2Carlton Associates Ltd (c) 2013
  3. 3. 33Carlton Associates Ltd (c) 2013 This module explores alternative Filter Media; automated backwashing and recommended settling periods after backwashing. In this Module we will be focusing on:
  4. 4. 4 • What is Happening to our Mechanical Systems • Link Between Backwashing, Filter Efficiency and Cryptosporidiosis • Coagulation • Backwashing Regimes • Use of Ultraviolet Radiation
  5. 5. 5 5 What’s happening to our mechanical systems?  Not very exciting, as these are not always in areas that are seen by the swimmers.  Without good management of mechanical systems, there wouldn’t be such good quality of customer provision.  So, do we carry out preventative work, or do we wait for something to happen?
  6. 6. 6 6 This can’t be right ………….. can it?? 6
  7. 7. 7 7 ANTI-VORTEX OUTLET GRILLES ……… are now a requirement, if there is a risk of vacuum formation. Courtesy of Sterling Hydrotech Ltd
  8. 8. 8 8 “MUDBALLING” INSIDE A FILTER
  9. 9. 9 9 Replacement Filter Media Imploded Glass Media Leighton Buzzard Sand Media 9
  10. 10. 10 THE LINK BETWEEN BACKWASHING; FILTER EFFICIENCY AND CRYPTOSPORIDIOSIS Unless Ultra-Violet Light or Ozone are used, the presence of the Cryptosporidium Oocyst, can only be trapped within the filter media, and then usually only if a coagulant is being used. If the processes used are inefficient, then the risk of cryptosporidium in the pool is increased.
  11. 11. 11 11 Coagulation: A filter type WITHOUT the addition of a coagulant has the ability to filter particles down to a particular size; approximately 8 microns. As a rule of thumb: • Salt 100 microns • Talcum powder 8 microns • Cryptosporidium oocysts 5 microns • Bacteria 1–5 microns A filter type WITH the addition of a coagulant can bind together these microscopic particles, and form, them into a size that CAN be held within the filter bed.
  12. 12. 12 BACKWASHING REGIMES  The process of backwashing fluidises the filter bed, as the compressed media is broken up by reversing the flow of water.  Filtration is most efficient and effective when the filter media is compressed.  It can take up to 4 hours for the filter media to regain its compression, and therefore its efficiency, This process is referred to as RIPENING.
  13. 13. 13 BACKWASHING REGIMES  Consequently, during the ripening period, the filter media is less efficient than it should be, and this could place the swimmers at risk of infection, if particles are being removed .  Backwashing should therefore be carried out when there is at least 4 hours of non-use programmed after the process is complete.  For many swimming pools, this will mean that backwashing should be carried out at the end of the operational day..
  14. 14. 14 14 ULTRAVIOLET RADIATION
  15. 15. 15 15 Swimming Pool Balance Tank Strainers Circulating Pump Chemical Measurement Coagulant Dosing Medium Rate Sand Filter Heat Exchanger Stabiliser Injection Point Disinfectant Injection Point Ultra Violet Light Unit ULTRA VIOLET LIGHT IN SWIMMING POOLS
  16. 16. How does it work?  Pool water is still filtered, but is then pass through a sealed stainless steel unit that houses the UV lamp.  The UV rays react with all bacteria, as well as chemicals that have been introduced into the pool water.  Therefore the outlet water is free from chemicals and bacteria, making it taste-free, smell-free, and very attractive to look at.  However, there is now a need to introduce low quantities of a hypochlorite disinfectant to react with pollution in the pool, before it is passed through the UV system. The Free Chlorine level would normally be between 0.5mg/l and 0.8mg/l 16
  17. 17. 17
  18. 18. Carlton Associates Ltd (c) 2013 That is the end of Module 3 What you need to do now: 1. Return to the course page 2. Download the module update notes and save them on your computer 3. Read through the notes 4. Print out the notes and insert them in your manual
  19. 19. Carlton Associates Ltd (c) 2013 End of Module 3 Presentation

×