Lake Kee Bsc (Hons) Arch Tech          My thesis explored the daylight design and daylight strategies of aproposed communi...
Daylight Analysis of Design Propositions for The Clongriffin Community Centre
The Analysis of angle of midday sun for Winter Solstice,         Spring Equinox and Summer Solstice
Sunpath diagram using Ecotect
Light Box Experiment using three different types of roof apertures under a clear skycondition , at 12pm on the 21st of Mar...
Options of vertical windows for the Clongriffin Community Centre.                       Images generated by Revit Architec...
Daylight Factor Calculation using Ecotect Software withthree options of vertical windows to examine the percentage of dayl...
Using Radiance generated images to analyse the daylight uniformity and          illuminance level of the Clongriffin Commu...
Using Radiance generated images to analyse the daylight uniformity and           illuminance level of the Clongriffin Comm...
The construction sequence using Sketchup program
The development of the triangular roof light detail
The development of the eaves and window detail
Upcoming SlideShare
Loading in …5
×

DIT Arch Tech Thesis 2010

1,169 views

Published on

DIT Arch Tech Bsc (Hons) Presentation

  • Be the first to comment

DIT Arch Tech Thesis 2010

  1. 1. Lake Kee Bsc (Hons) Arch Tech My thesis explored the daylight design and daylight strategies of aproposed community building in Clongriffin, Dublin. Two methods were used toperform the daylight analysis on the building. They were the Daylight FactorCalculation using the Ecotect software and the analysis of the illuminance level inthe building using images generated by the RADIANCE software. The results of bothmethods were then compared. The best daylight design strategy was applied usingthe results.
  2. 2. Daylight Analysis of Design Propositions for The Clongriffin Community Centre
  3. 3. The Analysis of angle of midday sun for Winter Solstice, Spring Equinox and Summer Solstice
  4. 4. Sunpath diagram using Ecotect
  5. 5. Light Box Experiment using three different types of roof apertures under a clear skycondition , at 12pm on the 21st of March 2010. The purpose is to study the impact ofdirect sunlight penetration into a room.
  6. 6. Options of vertical windows for the Clongriffin Community Centre. Images generated by Revit ArchitectureOption 1 - South East perspective view Option 2 - South East perspective view
  7. 7. Daylight Factor Calculation using Ecotect Software withthree options of vertical windows to examine the percentage of daylight penetration
  8. 8. Using Radiance generated images to analyse the daylight uniformity and illuminance level of the Clongriffin Community Centre12pm - 21st of March
  9. 9. Using Radiance generated images to analyse the daylight uniformity and illuminance level of the Clongriffin Community Centre12pm - 21st of June
  10. 10. The construction sequence using Sketchup program
  11. 11. The development of the triangular roof light detail
  12. 12. The development of the eaves and window detail

×