In-Spec Spectrophotometric Standards

319 views

Published on

  • Be the first to comment

  • Be the first to like this

In-Spec Spectrophotometric Standards

  1. 1. HOW IT WORKS: UV/Vis Spectrophotometer StandardsProblem: Having to verify GFS Chemicals also offersthat an instrument is other standards that can beperforming properly and is utilized to validate otherin calibration is becoming aspects of an instrument’sincreasingly common for performance. Wavelength,regulatory committees and stray light, and resolutioninternal QC procedures. filters are available. WhenThis is particularly true used together with the In-when using UV/Vis Spec® photometricspectrophotometers. These standards you can checkinstruments can slowly drift the overall health of yourout of spec as the lamp spectrophotometer .ages. In order to know that The In-Spec®the data you are collecting used from 200-900nm. product line also offers ais accurate it is vital to verify These standards are very solution designedthe instrument’s easy to use since they are specifically for theperformance. non-toxic, come completely increasingly popular short pre-made with no dilutions pathlength (1mm)Solution: By using a NIST- or mixing required and do instruments. Thesetraceable standard you can not require special disposal instruments utilize a veryverify that an instrument is procedures when you are short pathlength of light andin fact performing as it finished using them. GFS small sample usage. Theshould. This provides Chemicals offers a broad In-Spec® Nano-Kit consistsvalidity to the data that is range of absorbance values of two standards to checkcollected with the to match your tests or the absorbance values atinstrument. custom values are 260, 280, and 320nm. Many of the available. These wavelengths are thesolutions that are available To use the In-Spec® most common for DNA/RNAare either very costly, toxic, standards you would first quantification tests. The kitor not flexible and can’t baseline the instrument with comes with data for thosemeet your exact the supplied Background wavelengths at a 1mmspecifications. GFS Solution then you would run pathlength.Chemicals however has the the standard. You would When properly usedability with its In-Spec® compare the values that are and documented, the use ofStandards to find a solution obtained on your instrument a secondary, NIST-that will better fit your to the values listed on the traceable standard canrequirements. Certificate of Analysis. If provide you the security and GFS Chemical’s In- the values are within the peace of mind in knowingSpec® product line has a greater of 5% or +/- 0.004 that the data you collectbroad range of solutions. added to your instruments with your instrument is inFor photometric accuracy state accuracy then your fact accurate.there are the In-Spec® instrument is performingstandards which can be well.

×