Folheto BCL 300i

674 views

Published on

Published in: Technology, Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
674
On SlideShare
0
From Embeds
0
Number of Embeds
74
Actions
Shares
0
Downloads
2
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Folheto BCL 300i

  1. 1. Bar code reader BCL 300i The multi-talent with extensive equipment options modular individual sensor solutionsP R O D U C T I N F O R M AT I O N
  2. 2. You decidewhat your bar code reader can do.The bar code readers of the BCL 300i seriesset new standards in equipment options.What makes our new BCL 300i series special is its modularity. For the firsttime, you can select from a large number of equipment options to individuallyconfigure a device optimally for your application. You thereby obtain a bar codereader perfectly tailored to your needs with regard to function, connection,mounting, and operation and one that stands for reliability and systemavailability.Top performance and practical innovation in all areasThe BCL 300i convinces not only with its proven performance characteristicssuch as the high-performance code reconstruction technology, the integratedfieldbus connectivity and the—in this performance class—unrivalled optical dataat long operating range and wide opening angle.With the unique hood with integrated connectors, the device can also be quicklyconnected to your fieldbus environment without complicated plug mounting.In addition, the compact scanner can be used as an Ethernet switch in thenetwork and can be configured either via the browser-based webConfig toolconveniently and directly via Ethernet or directly in the PROFIBUS / PROFINETenvironment.
  3. 3. Compromises are a thing of the past – today the word is modular. modular ind ivi du al se ns or so lut io nsWith the new BCL 300i, select between freely combinable equipment variants.We call this flexible type of product configuration modular. Optics / read fields Display elements High Density (N) Medium Density (M) Graphical display Low Density (F) LED display Ultra Low Density (L) Scanner Oscillating mirror Deflection mirror Front scanner Line scanner Raster scanner Options Heating Mounting systems Interfaces Connection technology PROFIBUS PROFINET Modular connector hood Ethernet TCP/IP Modular terminal hood multiNet Modular connection box RS 232 / 422 / 485 Connection cable
  4. 4. Convincing performance characteristics:The advantages of the BCL 300i at a glance.modular individual sensor solutionsModularity Full CRT (code reconstruc- High-quality optics tion technology)First bar code reader with freely The most powerful code reconstruction The used optics facilitate a large depthcombinable equipment for optimum technology on the market; also reliably of field and wide opening angle foradaptation to your application. detects heavily damaged or soiled reliable detection, even with wide codes. conveyor lines.Integrated fieldbus webConfig Ethernet switchconnectivity = iA range of available fieldbus interfaces Operating-system independent, The device can function as an Ethernetenables direct integration and configura- browser-based configuration tool. switch to create a linearly structuredtion of the system without additional network.software. Flexible electrical Small construction connection For the BCL 300i, you can select from Compact housing design for problem- four different connection options. free placement directly at the conveyor line.
  5. 5. Configuration made simple.The fast track to custom configurationof your bar code reader.The Leuze electronic BCL 300i webConfig.With the integrated webConfig tool,an operating-system independent,web-technology based, multi-languageuser interface is available for configuri-ng the device. The individual parame-ters are presented in an easy-to-un-derstand, graphic form.The BCL 300i in the PROFIBUS /PROFINET world.With the integrated PROFIBUS or theintegrated PROFINET, it is possibleto configure the BCL 300i via themodule structure contained in theGSD / GSDML file directly via theHW Config. In doing so, the parame-ters that are set are stored in thecontrol and, should a device need tobe replaced, automatically transferredto the new device.
  6. 6. Diverse application possibilities Pallet ID Container identification Container identification Container identification with variable heights from the side Container identification Tray identification with autoReflAct
  7. 7. Reading field curves High Density (N) Reading field curves Medium Density (M) BCL 3xxi S/R1 N 102 – line scanner w/o deflection mirror BCL 3xxi S/R1 M 102 – line scanner w/o deflection mirror 100 150 75 m = 0.127 m = 0.2Reading field width [mm] Reading field width [mm] 100 50 m = 0.15 m = 0.3 50 25 m = 0.127 m = 0.15 0 m = 0.2 m = 0.2 m = 0.3 m = 0.5 m = 0.2 0 m = 0.5 -25 -50 -50 -100 -75 -100 -150 0 25 50 75 100 125 150 175 200 225 250 275 300 0 50 100 150 200 250 300 350 400 450 Read distance [mm] Read distance [mm] BCL 3xxi S/R1 N 100 – line scanner w/ deflection mirror BCL 3xxi S/R1 M 100 – line scanner w/ deflection mirror 100 150 75 m = 0.127 m = 0.2Reading field width [mm] Reading field width [mm] 100 50 m = 0.15 m = 0.3 50 25 m = 0.127 m = 0.15 m = 0.2 0 m = 0.2 m = 0.3 m = 0.5 m = 0.2 0 m = 0.5 -25 -50 -50 -100 -75 -100 -150 0 25 50 75 100 125 150 175 200 225 250 275 300 0 50 100 150 200 250 300 350 400 450 Read distance [mm] Read distance [mm] BCL 3xxi ON 100 – for oscillating-mirror scanner BCL 3xxi OM 100 – for oscillating-mirror scanner 100 150 75 m = 0.127 m = 0.2Reading field width [mm] Reading field width [mm] 100 50 m = 0.15 m = 0.3 50 25 m = 0.127 m = 0.15 m = 0.2 0 m = 0.5 m = 0.2 m = 0.3 m = 0.2 0 m = 0.5 -25 -50 -50 -100 -75 -100 -150 0 25 50 75 100 125 150 175 200 225 250 275 300 0 50 100 150 200 250 300 350 400 450 Read distance [mm] Read distance [mm] BCL 3xxi ON 100 – lat. oscillating-mirror scanner BCL 3xxi OM 100 – lat. oscillating-mirror scanner 100 150 80 125 m = 0.127 m = 0.2Reading field width [mm] Reading field width [mm] 100 60 75 40 m = 0.15 m = 0.3 50 20 m = 0.127 25 m = 0.15 m = 0.2 m = 0.2 m = 0.3 m = 0.5 0 m = 0.2 0 m = 0.5 -22 25 50 -40 75 -60 100 -80 125 -100 150 0 25 50 75 100 125 150 175 200 225 250 275 300 0 50 100 150 200 250 300 350 400 450 Read distance [mm] Read distance [mm]
  8. 8. Reading field curves Low Density (F) Reading field curves Ultra Low Density (L) BCL 3xxi S/R1 F 102 – line scanner w/o deflection mirror BCL 3xxi S/R1 L 102 – line scanner w/o deflection mirror 200 300 250 150 m = 0.3 m = 0.35Reading field width [mm] Reading field width [mm] 200 100 150 m = 0.35 m = 0.5 100 50 m = 0.35 50 m = 0.35 m = 0.5 m = 0.5 m = 0.8 m = 0.3 0 m = 0.5 0 m = 0.8 -50 -50 -100 -100 -150 -200 -150 -250 -200 -300 0 50 100 150 200 250 300 350 400 450 500 550 600 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 Read distance [mm] Read distance [mm] BCL 3xxi S/R1 F 100 – line scanner w/ deflection mirror BCL 3xxi S/R1 L 100 – line scanner w/ deflection mirror 200 300 250 150 m = 0.3 m = 0.35Reading field width [mm] Reading field width [mm] 200 100 150 m = 0.35 m = 0.5 100 50 50 m = 0.35 m = 0.35 m = 0.5 m = 0.5 m = 0.8 m = 0.3 0 m = 0.5 0 m = 0.8 -50 -50 -100 -100 -150 -200 -150 -250 -200 -300 0 50 100 150 200 250 300 350 400 450 500 550 600 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 Read distance [mm] Read distance [mm] BCL 3xxi OF 100 – for oscillating-mirror scanner BCL 3xxi OL 100 – for oscillating-mirror scanner 200 300 250 150 m = 0.3 m = 0.35Reading field width [mm] Reading field width [mm] 200 100 150 m = 0.35 m = 0.5 100 50 50 m = 0.35 m = 0.35 m = 0.5 m = 0.3 m = 0.5 m = 0.8 0 m = 0.5 0 m = 0.8 -50 -50 -100 -100 -150 -200 -150 -250 -200 -300 0 50 100 150 200 250 300 350 400 450 500 550 600 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 Read distance [mm] Read distance [mm] BCL 3xxi OF 100 – lat. oscillating-mirror scanner BCL 3xxi OL 100 – lat. oscillating-mirror scanner 200 300 250 150 m = 0.3 m = 0.35Reading field width [mm] Reading field width [mm] 200 100 150 m = 0.35 m = 0.5 100 50 50 m = 0.35 m = 0.35 m = 0.5 m = 0.3 m = 0.5 m = 0.8 0 m = 0.5 0 m = 0.8 -50 -50 -100 -100 -150 -200 -150 -250 -200 -300 0 50 100 150 200 250 300 350 400 450 500 550 600 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 Read distance [mm] Read distance [mm]
  9. 9. BCL 300i BCL 301i BCL 304i BCL 308i BCL 348iLine scanner Specifications of the line scanners without heatingTypeLine scanner without heating* Standalone multiNet Plus Slave PROFIBUS DP Ethernet PROFINETOptical dataLight source Laser diode = 655 nmBeam exit At the frontScanning rate 1,000 scans/sUseful opening angle Max. 60°Optics models / resolution High density (N): 0.127 – 0.2 mm; medium density (M): 0.2 – 0.5 mm; low density (F): 0.3 – 0.8 mm; ultra low density (L): 0.35 – 0.8 mmRead distance See reading field curvesLaser safety class 2 acc. to EN 60825-1, CDRH (U.S. 21 CFR 1040.10)Bar code dataCode types 2/5 Interleaved, Code 39, Code 128, EAN / UPC, Codabar, Code 93, RSS 14Number of bar codes per scan 6Electrical data External connection box (MA 100) External connection box (MA 100) M12 via MS 304 M12 via MS 308 M12 via MS 348Interface type M12 via MS 300 M12 via MS 301 Terminals via MK 304 Terminals via MK 308 Terminals via MK 348 Terminals via MK 300 Terminals via MK 301 Leuze standard, Leuze standard, PROFINET / RT,Protocols ACK/NAK, 3964 (R), RK 512, PROFIBUS DP Ethernet, TCP / IP / UDP Leuze multiNet plus TCP / IP, UDP Xon/XoffBaud rate 4,800 ... 115,400 Baud 4,800 ... 115,400 Baud 9.6 Kbaud –12 MBaud 10 / 100 MBaud 10 / 100 MBaud Data bits: 7,8 / Stop bits: 1,2 Data bits: 7,8 / Stop bits: 1,2Data formats Slave DPV1 – – Parity: None, Even, Odd Parity: None, Even, OddService interface USB 2.0 Mini-B type socketOperating voltage 18 ... 30 V DC (SK III, class 2)Power consumption Approx. 4 WOperating and display elementsDisplay (optional) Monochromatic graphical display, 128 × 32 pixel, background lighting (optional)Keyboard (optional) 2 buttonsLEDs 2 LEDs for power (PWR) and bus state (BUS), two-colored (red/green)Mechanical dataProtection class only with MS / MK / KB IP 65connection hoodsWeight 270 gDimensions (W × H × D) 44 × 95 × 68 mmHousing Diecast aluminumEnvironmental dataOperating temperature range 0 °C – +40 °CStorage temperature range -20 °C – +70 °CAir humidity Air humidity max. 90 % rel. humidity, non-condensingVibration IEC 60068-2-6, test FCShock IEC 60068-2-27, test EaContinuous shock IEC 60068-2-29, test EbElectromag. compatibility EN 55022, EN 61326-1; IEC 61000-6-2 (includes IEC 61000-4-2, -3, -4, -5 and -6)Line scanner with oscillating mirror Technical data same as for line scanner without heating, however with the following differences:TypeLine scanner with oscillating mirror w/o heating* Standalone multiNet Plus Slave PROFIBUS DP Ethernet PROFINET / RT, TCP / IPOptical dataBeam exit Lateral zero position at an angle of 90°Oscillation frequency 0-10 Hz (adjustable, max. frequency is dependent on set swivel angle)Max. swivel angle +/- 20° (adjustable)Electrical dataPower consumption Approx. 10 WMechanical dataWeight 580 gDimensions (W × H × D) 58 × 125 × 110 mmLine scanner with deflection mirror Technical data same as for line scanner without heating, however with the following differences:TypeLine scanner with deflection mirror w/o heating* Standalone multiNet Plus Slave PROFIBUS DP Ethernet PROFINET / RT, TCP / IPOptical dataBeam exit Optical data - beam exit with lateral zero position at an angle of 105°Electrical dataPower consumption Approx. 4 WMechanical dataWeight 350 gDimensions (W× H × D) 44 × 103 × 96 mm
  10. 10. Optoelectronic SensorsCubic seriesCylindrical Sensors, Mini Sensors, Fiber Optic AmplifiersMeasuring SensorsSpecial SensorsLight CurtainsForked SensorsDouble Sheet Monitoring, Splice DetectionInductive SwitchesAccessoriesIdentification SystemsData Transmission SystemsDistance MeasurementBar Code ReadersRF-IDent-SystemsModular Interfacing UnitsIndustrial Image Processing SystemsOptical Data Transmission SystemsOptical Distance Measurement/PositioningMobile Code ReadersSafety SensorsSafety SystemsSafety ServicesSafety Laser ScannerSafety Light CurtainsTransceivers and Multiple Light Beam Safety DevicesSingle Light Beam Safety DevicesAS-i-Safety Product RangeSafety Sensor Technology for PROFIBUS DPSafety Switches, Safety Locking Devices, Safety Command DevicesSafety RelaysSensor Accessories and Signal DevicesSafety Engineering SoftwareMachine Safety ServicesLeuze electronic GmbH + Co. KG en 01-2011/09 50116993In der Braike 1D-73277 Owen/GermanyPhone +49 (0) 7021 / 573-0Fax +49 (0) 7021 / 573-199info@leuze.dewww.leuze.com

×