Smart din rail module product sheet 1.3 website

  1. 1. Fifthplay Smart DIN rail module product sheet 1.0 - DRAFT 07/10/2013 19:22 Fifthplay Smart DIN Rail Module 16A The smart DIN rail module provides an easy and robust way to measure and control the energy consumption of individual circuits. Circuits can be remotely (anywhere in the world where one has access to the internet) controlled. The DIN rail module can be installed by an electrician. Features  Measurement of electricity consumption per 15 minutes (Wh)  Measurement of instantaneous power in real-time (W)  Remotely (web-based) switching of the module (on/off)  Local switch button on the module  Wireless communication and control (RF)  Encrypted data transfer  Reset function  LED indicates linking state with fifthplay gateway  LED indicates the switch status  Detect LED to easily find a specific module in a switch board  Local data buffer up to 25 hours when communication with gateway fails  Up to 50 modules per gateway
  2. 2. Fifthplay Smart DIN rail module product sheet 1.0 - DRAFT 07/10/2013 19:22 Installation guidelines  When mounting the modules adjacent to each other, a minimum of ½TE spacing should be preserved to ensure enough ventilation of the heat dissipation. Ensure the correct spacing by using the correct blank plates.  The modules can only be mounted adjacent to each other without spacing for continuous load below 14A.  Preferably place the modules at the bottom of the distribution board.  Ensure the temperature inside the cabin does not exceed 45°C. If needed, provide additional (forced) ventilation and sufficient air extraction at the top of the cabin.  Application example: o In a 12 unit small electrical cabinet, ventilation must be provided starting from 3 modules  Idle power consumption Typical 270mW  Operating temperature range (ambient): o Minimum 0°C, Maximum 45°C Radio signal range  When using the external antenna - Range up to 30m for line of sight - Penetration: 1 massif (concrete) wall or floor, up to 3 dry- or up to 2 brick walls/floors - Internal antenna ( no antenna plugged in ) up to 15 m  Distance between HAM / DIN module - For a module equipped with external antenna a distance of 1m should be respected between HAM <-> DIN - For a module equipped without external antenna, HAM and DIN module can be mounted adjacent to each other Use of an external magnetic base antenna - The external magnetic base antenna should be mounted on a metal surface of min 15 x 15 cm. If necessarily an extra metal base plate should be provided.
  3. 3. Fifthplay Smart DIN rail module product sheet 1.0 - DRAFT 07/10/2013 19:22 Wiring diagram
  4. 4. Fifthplay Smart DIN rail module product sheet 1.0 - DRAFT 07/10/2013 19:22 Technical Specifications Parameter Min. Nominal Max. Unit Conditions Size Width 35.5 mm 2TE Height 90 mm Depth 66 mm Power Voltage 207 230 253 VAC Frequency 50 Hz Own consumption 270 mW 230VAC, 50Hz, 25°C Load Outgoing current 16 A cos phi = 1; maximum startup current 80A during 20ms Switch cycles 50x10³ cos phi = 1; 16A; 250VAC; 25°C Relay Bi-stable relay , single pole Energy measurement Metering range 1 3680 W Accuracy +/- 0.5W +/- 2% +/- 3% 1W – 5W (resistive, capacitive, inductive) 5W – 3680W (resistive) 5W – 3680W (capacitive, inductive) At 230+/-1% VAC; 25°C RF communication Frequency 868.0 - 868.6 868.7 - 869.05 MHz non-specific short range device Antenna Internal or external antenna SMA / SMB connector Environmental Conditions Operating temperature 0 45 °C
  5. 5. Fifthplay Smart DIN rail module product sheet 1.0 - DRAFT 07/10/2013 19:22 Test results Cos phi Measurement plug [W] Measurement calibrated meter [W] % error Info 1 24.82 50.9 90.2 105.9 144.7 191.1 229.6 346.4 530.3 997 1206.5 1360.2 1465.3 1907.6 1977.7 2127.5 2388.2 2995.5 3188.3 3347.6 3580 25 50.7 89.2 104.8 142.9 188.4 226.4 341.5 521.7 981.6 1187.6 1339.6 1442.6 1878.6 1946.6 2094.6 2351.6 2949.6 3136.6 3291.6 3520.6 -0.72% 0.39% 1.12% 1.05% 1.26% 1.43% 1.41% 1.43% 1.65% 1.57% 1.59% 1.54% 1.57% 1.54% 1.60% 1.57% 1.56% 1.56% 1.65% 1.70% 1.69% Ta = 25°C 0.4 Inductive 62.67 61.7 1.57% Ta = 25°C 0.312 Inductive 95.56 93.5 2.20% Ta = 25°C 0.67 327.7 322.6 1.58% Ta = 25°C
  6. 6. Fifthplay Smart DIN rail module product sheet 1.0 - DRAFT 07/10/2013 19:22 Inductive 0.337 Inductive 195.2 190.6 2.41% Ta = 25°C 0.156 Capacitive 38.7 39.4 -1.78% Ta = 25°C 0.266 Capacitive 68.4 68.8 -0.58% Ta = 25°C 0.552 Capacitive 165.4 164.4 0.61% Ta = 25°C 0.718 Capacitive 258 255.7 0.90% Ta = 25°C 0.921 0.926 0.928 0.928 12.97 26.2 39.5 52.7 13.1 26.1 39.4 52.4 -0.99% 0.38% 0.25% 0.57% Used load(s): OSRAM ParaThom CLA 80 Ta = 25°C 0.797 0.802 0.805 0.806 0.808 0.808 12.9 26.7 40.2 53.9 67.5 80.8 13.1 26.7 40 53.5 66.9 79.9 -1.53% 0.00% 0.50% 0.75% 0.90% 1.13% Used load(s): PHILIPS 12E27A60 Ta = 25°C 0.766 0.765 0.772 0.768 0.777 0.776 0.773 13.5 26.4 40.2 58 72.3 81.8 94.2 13.8 26.9 39.8 57.6 71.8 81.2 93.5 -2.17% -1.86% 1.01% 0.69% 0.70% 0.74% 0.75% Used load(s): Tornado 13W Ta = 25°C

×