Detección Lineal de Temperatura o Cable Detector

1,192 views

Published on

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
1,192
On SlideShare
0
From Embeds
0
Number of Embeds
320
Actions
Shares
0
Downloads
6
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Detección Lineal de Temperatura o Cable Detector

  1. 1. A D D R E S S A B L ELINEAR HEAT DETECTION
  2. 2. ▪ Innovations▪ Solutions▪ Support Linear Heat Detection Better Now for Use on ANY Addressable Panel Just Add an Addressable Contact Monitor Module Compatible with ANY Conventional Fire Alarm Panel Farther Up to 10,000 Linear Feet (3,000m) of SafeCable per Zone RF Tested up to 10,000 Linear Feet (3,000m) Longer Spool Lengths Available Lower Cost Lower Material Costs Less Installation Time No Expensive Linear Heat Detection Panels to Buy and Maintain
  3. 3. ▪ Longer Runs ▪ Less Resistance ▪ Lower cost Up to 10,000 Linear Feet per Zone DetectionProducts Temperatures: 155 F (68 C) 172 F (78 C) Advanced Design Allows Up to 10,000 Linear Feet of SafeCable 190 F (88 C) per Zone 220 F (105 C) Tri-Metallic Core Reduces Resistance to Only .05 ohms/ft Resistance per Twisted Pair Wire Designed to be Compatible with ALL Addressable and Conventional Fire Alarm Control and Releasing Panels Reduce Material and Installation Costs with Less Splicing, Longer Spool Lengths, and Easier Installation Multiple alarm temperatures can be combined on the same zone Total zone length replacement unnecessary after alarm
  4. 4. ▪ Longer Runs ▪ Less Resistance ▪ Lower cost Up to 10,000 Linear Feet per Zone Detection Temperatures: 155 F (68 C) 172 F (78 C)Multiple Outer Coverings Available for Specific Hazards 190 F (88 C) 220 F (105 C) Nylon - UV protected for outdoor applications and extra durable for harsh industrial environments. Polypropylene – For chemically harsh and caustic environments such as wet benches. GuideWire – For spanning distances up to 250 ft. (76m) with supports every 15 ft. (4.6m). TC155NG Temperature Guidewire Nylon
  5. 5. ▪ Longer Runs ▪ Less Resistance ▪ Lower cost Up to 10,000 Linear Feet per Zone Detection Temperatures: 155 F (68 C) 172 F (78 C)Alarm Point Distance Locating Displays in Both Feet and Meters 190 F (88 C) 220 F (105 C)May be Used for Both Class “A” and “B” Applications Alarm Point Distance Locating
  6. 6. ▪ Longer Runs ▪ Less Resistance ▪ Lower cost Only .05 ohms/ft resistance per Twisted Pair SPACING AND TEMPERATUREProducts Listed Spacing Temperature Rating UL, C-UL-US FM 155 F (68 C) 35’ (10.7m) 30’ (9.1m) 172 F (78 C) 35’ (10.7m) 30’ (9.1m) 190 F (88 C) 35’ (10.7m) 30’ (9.1m) 220 F (105 C) 35’ (10.7m) 25’ (7.6m) Area Spacing .7x 17’6” (5.3m) 35’ (10.7m)
  7. 7. ▪ Any Panel ▪ Addressable ▪ Conventional System ComponentsComponents
  8. 8. ▪ Any Panel▪ Addressable▪ Conventional Typical System Configurations ADDRESSABLE SYSTEM CONVENTIONAL SYSTEM CONFIGURATION CONFIGURATION
  9. 9. ▪ Mounting ▪ Connecting ▪ Splicing Installation Accessories Mounting Connecting SplicingAccessories Clamps, Clips, Ties, Junction Boxes and Terminal Blocks, Mounts, Adhesive Fittings Tapes, Sealers
  10. 10. ▪ Commercial ▪ Industrial ▪ UtilitiesFlexibility to Adapt to Your Environment
  11. 11. ▪ Any Panel▪ Addressable▪ Conventional Addressable / Conventional Linear Heat Detection Linear Heat Detection
  12. 12. One Company, Five Great Products

×