SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005                                     & ANSI/NCSL Z540-1-1994                  ...
III. Dimensional Parameter/Equipment                Range                     CMC2, 6 ()         Comments Calipers3      ...
Parameter/Equipment              Range            CMC2, 6 ()           Comments Ring Gages, Cylindrical &     (0.1 to 12)...
Parameter/Equipment              Range        CMC2, 4, 5, 7 ()          Comments High DC Voltage – Measure3   (1 to 40) k...
Parameter/Equipment              Range               CMC2, 4, 5, 6, 7 ()       Comments Resistance – Generate,    1Ω     ...
Parameter/Equipment               Range              CMC2, 6 ()       Comments Inductance – Generate3  Fixed Points      ...
Parameter/Equipment                Range                  CMC2, 4 ()       Comments Electrical Calibration of RTD Indicat...
Parameter/Range            Frequency           CMC2, 4 ()       Comments AC Voltage – Generate3  (0 to 220) mV           ...
Parameter/Range            Frequency           CMC2, 4 ()       Comments AC Voltage – Measure3  Up to 10 mV             (...
Parameter/Range            Frequency           CMC2, 4 ()       Comments AC Voltage – Measure3 (cont.)  7.0 mV           ...
Parameter/Range           Frequency            CMC2, 4 ()      Comments AC Voltage – Measure3 (cont.)  2.2 V             ...
Parameter/Range            Frequency             CMC2, 4, 7 ()       Comments AC Voltage – Measure3 (cont.)  220 V       ...
Parameter/Range              Frequency       CMC2, 5, 7 ()         Comments AC Current – Measure3     Up to 100 μA       ...
Parameter/Equipment                 Range              CMC2, 7 ()         Comments Amplitude Modulation3 – Measure   Rate...
VII. Mechanical  Parameter/Equipment             Range                 CMC2, 7 ()           Comments Torque3             ...
VIII. Optical Quantities   Parameter/Equipment              Range                CMC2, 7 ()         Comments Optical Powe...
X. Time & Frequency       Parameter/Equipment                         Frequency          CMC2 ()                 Comments...
A2LA has accredited                   MICRO PRECISION CALIBRATION                                     Batino, Calamba City...
Upcoming SlideShare
Loading in …5
×

A2 la accreditation valid until apr 30 2013

328 views

Published on

Published in: Business, Technology
  • Be the first to comment

  • Be the first to like this

A2 la accreditation valid until apr 30 2013

  1. 1. SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 MICRO PRECISION CALIBRATION Block 2 Lot 4 Calamba Premier Intl. Park Batino, Calamba City Laguna, Philippines 4027 Kenneth Ellett II Phone: 63 49 5023015 CALIBRATIONValid To: April 30, 2013 Certificate Number: 0935.05In recognition of the successful completion of the A2LA evaluation process, accreditation is granted tothis laboratory to perform the following calibrations1:I. Acoustical Quantities Parameter/Equipment Range CMC2 () Comments Sound3 (125 to 2000) Hz (74 to 114) dB SPL 0.4 dB Genrad 1986 sound level calibrator 4000 Hz (74 to 114) dB SPL 0.6 dBII. Chemical Quantities Parameter/Equipment Range CMC2 () Comments Conductivity – 146.9 µS 1.8 µS Comparison to standard Measure3 180 µS 4.8 µS solutions 1015 µS 2.5 µS 1408 µS 3.4 µS 111 mS 0.32 mS pH – Measure3 (4, 7, 10) pH unit 0.03 pH unit Comparison to standard solutions(A2LA Cert. No. 0935.05) 10/27/2011 Page 1 of 17
  2. 2. III. Dimensional Parameter/Equipment Range CMC2, 6 () Comments Calipers3 (0.10 to 12) in (56 + 0.6L) µin Grade 2 gage blocks (12 to 48) in (600 + 100L) µin Height Gages3 (0.10 to 12) in (56 + 0.6L) µin Grade 2 gage blocks (12 to 48) in (600 + 100L) µin Optical Comparators Up to 300 mm 140 µm Glass scales and gage and Visual Systems3 blocks Indicators3 – Resolution: 100 µin (0.1 to 4) in 82 µin Indicator calibrator 50 µin 59 µin Micrometers3 – Outside, Inside, Depth Resolution: 100 µin (0.10 to 48) in (82 + 10L) µin Gage blocks, optical 50 µin (0.10 to 4) in (60 + 10L) µin flat, monochromic light source Surface Plates3 – Repeatability (12 x 12 to 72 x 144) in 43 µin Repeat-o-meter Flatness (6 to 120) in (diagonal) 71 µin Planekator Micrometer Rods/ (0.1 to 12) in (58 + 0.6L) µin Supermic, gage blocks Length Standards Cylindrical Plug (0.1 to 12) in (12 + 0.34L) µin Supermic Gages(A2LA Cert. No. 0935.05) 10/27/2011 Page 2 of 17
  3. 3. Parameter/Equipment Range CMC2, 6 () Comments Ring Gages, Cylindrical & (0.1 to 12) in (15 + 1.5L) µin Supermic Tapered Steel Rules Up to 72 in 1.2 min Grade 2 gage blocks Tape Measure Up to 300 in 9.1 min Grade 2 gage blocks Thread Wires (4 to 120) T.P.I. (8 + 3D) µin Supermic Gage Blocks Up to 4 in (7.8 + 5L) µin Gage blocks Thread Plugs – Pitch (0.10 to 4.00) in (66 + 1.2L) μin Supermic, thread wires Diameter, External Threads (24 + 1.2L) μin using three wire method Bore Micrometers, Bore Up to 8 in 61 µin Master ring gage GagesIV. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4, 5 () Comments DC Voltage – Generate3 (0 to 220) mV 12 µV/V + 0.6 µV Fluke 5700A 220 mV to 2.2 V 12 µV/V + 1.0 µV (2.2 to 11) V 11 µV/V + 3.5 µV (11 to 22) V 12 µV/V + 6.5 µV (22 to 220) V 13 µV/V + 80 µV (220 to 1100) V 13 µV/V + 500 µV 10 V 5.7 µV/V Fluke 732A zener voltage standard DC Voltage – Measure3 (0 to 100) mV 13 µV/V + 3.0 µV HP 3458A 100 mV to 1V 17 µV/V + 0.3 µV (1 to 10) V 13 µV/V + 0.5 µV (10 to 100) V 15 µV/V + 30 µV (100 to 1000) V 27 µV/V + 100 µV(A2LA Cert. No. 0935.05) 10/27/2011 Page 3 of 17
  4. 4. Parameter/Equipment Range CMC2, 4, 5, 7 () Comments High DC Voltage – Measure3 (1 to 40) kV 0.10 % Vitrek 4640B DC Current – Generate3 (0 to 220) A 40 A/A + 8 nA Fluke 5700A 220 A to 22 mA 44 A/A + 8 nA (22 to 220) mA 47 A/A + 80 nA 220 mA to 2.2 A 55 A/A + 0.8 µA (2.2 to 11) A 83 A/A + 25 µA Fluke 5500A (11 to 20.5) A 0.12 % Fluke 5520A (1 to 1000) A 0.92 % Fluke 5500A w/ current coil, Valhalla 2555A DC Current – Measure3 (10 to 100) A 26 µA/A + 5 µA HP 3458A 100 A to 10 mA 26 uA/A + 5 µA (10 to 100) mA 60 µA/A + 5 µA 100 mA to 1 A 0.013 % + 10 µA High DC Current – (1 to 50) A 0.12 % Shunt monitored with Measure3 (50 to 300) A 0.22 % multimeter (300 to 1000) A 0.28 % Resistance – Generate3 Up to 11 Ω 0.015 % + 0.008 Ω Fluke 5500A (11 to 33) Ω 0.014 % + 0.015 Ω (33 to 110) Ω 0.011 % + 0.015 Ω (110 to 330) Ω 0.011 % + 0.015 Ω (0.33 to 1.1) kΩ 0.011 % + 0.06 Ω (1.1 to 3.3) kΩ 0.011 % + 0.06 Ω (3.3 to 11) kΩ 0.14 % + 0.6 Ω (11 to 33) kΩ 0.14 % + 0.6 Ω (33 to 110) kΩ 0.18 % + 6 Ω (110 to 330) kΩ 0.18 % + 6 Ω 330 kΩ to 1.1 MΩ 0.12 % + 55 Ω (1.1 to 3.3) MΩ 0.18 % + 55 Ω (3.3 to 11) MΩ 0.15 % + 550 Ω (11 to 33) MΩ 0.17 % + 550 Ω (33 to 110) MΩ 0.6 % + 5.5 kΩ (110 to 330) MΩ 0.6 % + 17 kΩ(A2LA Cert. No. 0935.05) 10/27/2011 Page 4 of 17
  5. 5. Parameter/Equipment Range CMC2, 4, 5, 6, 7 () Comments Resistance – Generate, 1Ω 0.013 % Fluke 5700A Fixed Points3 10 Ω 39 µΩ/Ω 100 Ω 24 µΩ/Ω 1 kΩ 18 µΩ/Ω 10 kΩ 17 µΩ/Ω 100 kΩ 19 µΩ/Ω 1 MΩ 27 µΩ/Ω 10 MΩ 54 µΩ/Ω 100 MΩ 0.016 % Resistance – Measure3 (0 to 10) Ω 19 µΩ/Ω + 0.06 mΩ HP 3458A (10 to 100) Ω 15 µΩ/Ω + 0.6 mΩ 100  to 100 kΩ 13 µΩ/Ω + 0.6 mΩ 100 kΩ to 1 M 18 µΩ/Ω + 2.4 Ω (1 to 10) MΩ 59 µΩ/Ω + 120 Ω (10 to 100) MΩ 0.058 % + 1.2 kΩ 100 MΩ to 1 GΩ 1.8 % + 10 kΩ Capacitance – Generate3 (0.33 to 0.49) nF 3.3 % Fluke 5500A (0.50 to 1.09) nF 1.7 % (1.10 to 3.29) nF 0.93 % (3.30 to 10.9) nF 0.69 % (11.0 to 32.9) nF 0.64 % (33 to 109.9) nF 0.40 % (110 to 329.9) nF 0.40 % (0.33 to 1.09) µF 0.40 % (1.10 to 3.29) µF 0.51 % Fixed Values 1 MHz (1, 10, 100, 1000) pF 0.12 % HP 16380A and 1 kHz (10, 100) nF 0.12 % 16380C standard 1 kHz 1 µF 0.12 % capacitor sets Capacitance – Measure3 1 kHz 10 pF to 1 mF 0.10 % IV GenRad 1689 Inductance – Measure3, Fixed Value 1 kHz 1H 0.12 % GenRad 1689(A2LA Cert. No. 0935.05) 10/27/2011 Page 5 of 17
  6. 6. Parameter/Equipment Range CMC2, 6 () Comments Inductance – Generate3 Fixed Points 100 µH 0.12 % IV GenRad 1482 1 mH 0.059 % IV 10 mH 0.06 % IV 100 mH 0.062 % IV 2H 0.075 % IV 10 H 0.08 % IV Electrical Calibration of Thermocouple Indicators3 – Type E -250 ºC to -100 ºC 0.5 ºC Fluke 5500A -100 ºC to 650 ºC 0.16 ºC 650 ºC to 1000 ºC 0.21 ºC Type J -210 ºC to -100 ºC 0.27 ºC -100 ºC to 760 ºC 0.17 ºC 760 ºC to 1200 ºC 0.23 ºC Type K -200 ºC to -100 ºC 0.33 ºC -100 ºC to 120 ºC 0.18 ºC 120 ºC to 1000 ºC 0.26 ºC 1000 ºC to 1372 ºC 0.04 ºC Type S 0 ºC to 250 ºC 0.47 ºC 250 ºC to 1400 ºC 0.37 ºC 1400 ºC to 1767 ºC 0.46 ºC Type T -250 ºC to -150 ºC 0.63 ºC -150 ºC to 0 ºC 0.24 ºC 0 ºC to 400 ºC 0.16 ºC Electrical Calibration of RTD Indicating Systems3 – Pt 385, 100  -200 C to 0 C 0.05 C Fluke 5500A 0 C to 100 C 0.07 C 100 C to 400 C 0.10 C 400 C to 630 C 0.12 C 630 C to 800 C 0.23 C Pt 3926, 100  -200 C to 0 C 0.05 C 0 C to 100 C 0.07 C 100 C to 400 C 0.10 C 400 C to 630 C 0.12 C(A2LA Cert. No. 0935.05) 10/27/2011 Page 6 of 17
  7. 7. Parameter/Equipment Range CMC2, 4 () Comments Electrical Calibration of RTD Indicating Systems3 – (cont.) Pt 3916, 100  -200 C to -190 C 0.25 C Fluke 5500A -190 C to 0 C 0.05 C 0 C to 300 C 0.08 C 300 C to 600 C 0.10 C 600 C to 630 C 0.23 C Pt 385, 200  -200 C to 100 C 0.04 C 100 C to 260 C 0.05 C 260 C to 600 C 0.14 C 600 C to 630 C 0.16 C Pt 385, 500  -200 C to 100 C 0.05 C 100 C to 260 C 0.06 C 260 C to 600 C 0.09 C 600 C to 630 C 0.11 C Pt 385, 1 k -200 C to 100 C 0.03 C 100 C to 260 C 0.05 C 260 C to 600 C 0.07 C 600 C to 630 C 0.23 C PtNi 385, 100  -80 C to 100 C 0.08 C 100 C to 260 C 0.14 C Cu 427, 10  -100 C to 260 C 0.3 C(A2LA Cert. No. 0935.05) 10/27/2011 Page 7 of 17
  8. 8. Parameter/Range Frequency CMC2, 4 () Comments AC Voltage – Generate3 (0 to 220) mV (10 to 20) Hz 0.055 % + 13 μV Fluke 5700A (20 to 40) Hz 0.021 % + 8 μV 40 Hz to 20 kHz 0.011 % + 8 μV (20 to 50) kHz 0.037 % + 8 μV (50 to 100) kHz 0.085 % + 25 μV 100 kHz to 1 MHz 0.34 % + 80 μV 220 mV to 2.2 V (10 to 20) Hz 0.05 % + 80 μV (20 to 40) Hz 0.016 % + 25 μV 40 Hz to 20 kHz 75 V/V + 6 μV (20 to 50) kHz 0.012 % + 16 μV (50 to 100) kHz 0.025 % + 70 μV 100 kHz to 1 MHz 0.22 % + 850 μV (2.2 to 22) V (10 to 20) Hz 0.05 % + 0.8 mV Fluke 5700A (20 to 40) Hz 0.016 % + 0.25 mV w/5725 40 Hz to 20 kHz 75 µV/V + 0.06 mV (20 to 50) kHz 0.012 % + 0.16 mV (50 to 100) kHz 0.025 % + 0.35 mV 100 kHz to 1 MHz 0.34 % + 8.5 mV (22 to 220) V (10 to 20) Hz 0.05 % + 8 mV Fluke 5500A (20 to 40) Hz 0.016 % + 2.5 mV 40 Hz to 20 kHz 80 µV/V + 0.8 mV (20 to 50) kHz 0.022 % + 3.5 mV (50 to 100) kHz 0.05 % + 8 mV 100 kHz to 1 MHz 1.6 % + 190 mV (220 to 750) V (30 to 50) kHz 0.06 % + 11 mV (50 to 100) kHz 0.23 % 45 mV (220 to 1100) V (15 to 50) Hz 0.04 % + 16 mV (50 to 1000) Hz 90 µV/V + 4 mV(A2LA Cert. No. 0935.05) 10/27/2011 Page 8 of 17
  9. 9. Parameter/Range Frequency CMC2, 4 () Comments AC Voltage – Measure3 Up to 10 mV (1 to 40) Hz 0.03 % + 3 μV Fluke 5790A 40 Hz to 1 kHz 0.02 % + 2 μV (1 to 20) kHz 0.03 % + 2 μV (20 to 50) kHz 0.12 % + 2 μV (50 to 100) kHz 0.58 % + 2 μV (100 to 300) kHz 4.6 % + 2 μV 10 mV to 10 V (1 to 40) Hz 80 µV/V + 0.4 mV 40 Hz to 1 kHz 80 µV/V + 0.2 mV (1 to 20) kHz 0.02 % + 0.2 mV (20 to 50) kHz 0.03 % + 0.2 mV (50 to 100) kHz 0.09 % + 0.2 mV (100 to 300) kHz 0.35 % + 1 mV 300 kHz to 1 MHz 1.2 % + 1 mV (1 to 2) MHz 1.7 % + 1 mV (10 to 100) V (1 to 40) Hz 0.02 % + 4 mV 40 Hz to 1 kHz 0.02 % + 2 mV (20 to 50) kHz 0.04 % + 2 mV (50 to 100) kHz 0.14 % + 2 mV (100 to 300) kHz 0.46 % + 10 mV 300 kHz to 1 MHz 1.7 % + 10 mV (100 to 700) V (1 to 40) Hz 0.05 % + 40 mV 40 Hz to 1 kHz 0.05 % + 20 mV (1 to 20) kHz 0.07 % + 20 mV (20 to 50) kHz 0.14 % + 20 mV (50 to 100) kHz 0.35 % + 20 mV 2.2 mV (10 to 20) Hz 0.17 % + 1.3 μV (20 to 40) Hz 0.074 % + 1.3 μV 40 Hz to 20 kHz 0.042 % + 1.3 μV (20 to 50) kHz 0.081 % + 2 μV (50 to 100) kHz 0.012 % + 2.5 μV (100 to 300) kHz 0.023 % + 4 μV (300 to 500) kHz 0.024 % + 8 μV 500 kHz to 1 MHz 0.35 % + 8 μV(A2LA Cert. No. 0935.05) 10/27/2011 Page 9 of 17
  10. 10. Parameter/Range Frequency CMC2, 4 () Comments AC Voltage – Measure3 (cont.) 7.0 mV (10 to 20) Hz 0.86 % + 1.3 μV Fluke 5790A (20 to 40) Hz 0.038 % + 1.3 μV 40 Hz to 20 kHz 0.024 % + 1.3 μV (20 to 50) kHz 0.046 % + 2 μV (50 to 100) kHz 0.065 % + 2.5 μV (100 to 300) kHz 0.013 % + 4 μV (300 to 500) kHz 0.015 % + 8 μV 500 kHz to 1 MHz 0.24 % + 8 μV 22 mV (10 to 20) Hz 0.033 % + 1.3 μV (20 to 40) Hz 0.021 % + 1.3 μV 40 Hz to 20 kHz 0.012 % + 1.3 μV (20 to 50) kHz 0.023 % + 2 μV (50 to 100) kHz 0.035 % + 2.5 μV (100 to 300) kHz 0.082 % + 4 μV (300 to 500) kHz 0.097 % + 8 μV 500 kHz to 1 MHz 0.19 % + 8 μV 70 mV (10 to 20) Hz 0.029 % + 1.8 μV (20 to 40) Hz 0.013 % + 1.8 μV 40 Hz to 20 kHz 0.0071 % + 1.8 μV (20 to 50) kHz 0.016 % + 2.9 μV (50 to 100) kHz 0.031 % + 4.8 μV (100 to 300) kHz 0.056 % + 6.4 μV (300 to 500) kHz 0.080 % + 9.5 μV 500 kHz to 1 MHz 0.13 % + 9.5 μV 220 mV (10 to 20) Hz 0.025 % + 1.8 μV (20 to 40) Hz 0.0092 % + 1.8 μV 40 Hz to 20 kHz 0.0046 % + 1.8 μV (20 to 50) kHz 0.011 % + 2.9 μV (50 to 100) kHz 0.024 % + 2.5 μV (100 to 300) kHz 0.035 % + 6.4 μV (300 to 500) kHz 0.060 % + 9.5 μV 500 kHz to 1 MHz 0.12 % + 9.5 μV 700 mV (10 to 20) Hz 0.024 % + 11 μV (20 to 40) Hz 0.0082 % + 5.3 μV 40 Hz to 20 kHz 0.0024 % + 1.9 μV (20 to 50) kHz 0.057 % + 2.9 μV (50 to 100) kHz 0.011 % + 4.8 μV (100 to 300) kHz 0.022 % + 16 μV (300 to 500) kHz 0.038 % + 41 μV 500 kHz to 1 MHz 0.12 % + 0.11 mV(A2LA Cert. No. 0935.05) 10/27/2011 Page 10 of 17
  11. 11. Parameter/Range Frequency CMC2, 4 () Comments AC Voltage – Measure3 (cont.) 2.2 V (10 to 20) Hz 0.024 % + 10 μV Fluke 5790A (20 to 40) Hz 0.0078 % + 5 μV 40 Hz to 20 kHz 0.0032 % + 1 μV (20 to 50) kHz 0.0055 % + 2 μV (50 to 100) kHz 0.010 % + 4 μV (100 to 300) kHz 0.020 % + 15 μV (300 to 500) kHz 0.036 % + 40 μV 500 kHz to 1 MHz 0.11 % + 0.1 mV 7.0 V (10 to 20) Hz 0.024 % + 0.1 mV (20 to 40) Hz 0.0078 % + 0.03 mV 40 Hz to 20 kHz 0.0023 % + 0.01 mV (20 to 50) kHz 0.0056 % + 0.02 mV (50 to 100) kHz 0.011 % + 0.04 mV (100 to 300) kHz 0.025 % + 0.15 mV (300 to 500) kHz 0.048 % + 0.3 mV 500 kHz to 1 MHz 0.13 % + 0.5 mV 22 V (10 to 20) Hz 0.024 % + 0.1 mV (20 to 40) Hz 0.0078 % + 0.03 mV 40 Hz to 20 kHz 0.0033 % + 0.01 mV (20 to 50) kHz 0.0056 % + 0.02 mV (50 to 100) kHz 0.011 % + 0.04 mV (100 to 300) kHz 0.024 % + 0.15 mV (300 to 500) kHz 0.048 % + 0.3 mV 500 kHz to 1 MHz 0.13 % + 0.5 mV 70 V (10 to 20) Hz 0.024 % + 1 mV (20 to 40) Hz 0.0078 % + 0.3 mV 40 Hz to 20 kHz 0.0041 % + 0.08 mV (20 to 50) kHz 0.0081 % + 0.1 mV (50 to 100) kHz 0.015 % + 0.5 mV (100 to 300) kHz 0.032 % + 0.6 mV (300 to 500) kHz 0.062 % + 0.8 mV 500 kHz to 1 MHz 0.17 % + 1 mV(A2LA Cert. No. 0935.05) 10/27/2011 Page 11 of 17
  12. 12. Parameter/Range Frequency CMC2, 4, 7 () Comments AC Voltage – Measure3 (cont.) 220 V (10 to 20) Hz 0.023 % + 1 mV Fluke 5790A (20 to 40) Hz 0.0078 % + 0.3 mV 40 Hz to 20 kHz 0.0041 % + 0.08 mV (20 to 50) kHz 0.009 % 0.1 mV (50 to 100) kHz 0.016 % + 0.5 mV (100 to 300) kHz 0.033 % + 0.6 mV (300 to 500) kHz 0.069 % + 0.8 mV 700 V (10 to 20) Hz 0.02 % (20 to 40) Hz 0.01 % 40 Hz to 20 kHz 0.01 % (20 to 50) kHz 0.05 % (50 to 100) kHz 0.21 % 1000 V (10 to 20) Hz 0.02 % (20 to 40) Hz 0.01 % 40 Hz to 20 kHz 0.01 % (20 to 50) kHz 0.05 % (50 to 100) kHz 0.21 % AC High Voltage – Measure3 (1 to 40) kV (50 to 60) Hz 0.3 % Vitrek 4640B AC Current – Generate3 (1 to 220) μA 40 Hz to 1 kHz 0.09 % Fluke 5700A 220 μA to 22 mA 0.03 % (22 to 220) mA 0.03 % 220 mA to 2.2 A 0.09 %(A2LA Cert. No. 0935.05) 10/27/2011 Page 12 of 17
  13. 13. Parameter/Range Frequency CMC2, 5, 7 () Comments AC Current – Measure3 Up to 100 μA (10 to 20) Hz 0.46 % + 0.03 μA HP 3458A (20 to 45) Hz 0.18 % + 0.03 μA 45 Hz to 1 kHz 0.078 % + 0.03 μA 100 μA to 100 mA (10 to 20) Hz 0.46 % + 20 μA (20 to 45) Hz 0.17 % + 20 μA (45 to 100) Hz 0.073 % + 20 μA 100 Hz to 5 kHz 0.042 % + 20 μA 100 mA to 1 A (10 to 20) Hz 0.46 % + 200 μA (20 to 45) Hz 0.19 % + 200 μA (45 to 100) Hz 0.10 % + 200 μA 100 Hz to 5 kHz 0.12 % + 200 μA AC Current – Generate3 (110 to 550) A (45 to 65) Hz 1.4 % Fluke 5500A with Fluke 50-turn coil Up to 1000 A (65 to 440) Hz 1.9 % Valhalla 2555AV. Electrical – RF/Microwave Parameter/Equipment Range CMC2, 7 () Comments RF Tuned Power3 – Generate, Connector Type N Up to 1.3 GHz (0 to -3) dB 0.40 dB HP 8902A 2.5 MHz to 26.5 GHz (-3 to -127) dB 0.72 dB w/HP11722A, HP11793A, HP 11792A RF Absolute Power3 – Generate, Connector Type N 50 MHz to 50 GHz (-70 to -30) dB 0.64 dB HP 438B, 8484A, (-30 to -20) dB 0.06 dB 8481A, 8487A (-20 to +10) dB 0.068 dB (+10 to +20) dB 1.2 %(A2LA Cert. No. 0935.05) 10/27/2011 Page 13 of 17
  14. 14. Parameter/Equipment Range CMC2, 7 () Comments Amplitude Modulation3 – Measure Rate: 150 kHz to 10 MHz 50 Hz to 10 kHz 4.0 % HP 8902A Depth: (5 to 99) % 20 Hz to 100 kHz 4.6 % Rate: 10 MHz to 1.3 GHz 50 Hz to 50 kHz 3.6 % Depth: (5 to 99) % 20 Hz to 100 kHz 4.6 % Frequency Modulation – Measure3 Rate: 250 kHz to 10 MHz 20 Hz to 10 kHz 3.1 % HP 8902A Dev:  40 kHz Rate: 10 MHz to 1.3 GHz 20 Hz to 200 kHz 7.7 % Dev:  400 kHz 50 Hz to 100 kHz 1.6 % Phase Modulation3 – Measure Rate: 10 MHz to 1.3 GHz 200 Hz to 20 kHz 7.0 % HP 8902AVI. Fluid Quantities Parameter/Equipment Range CMC2 () Comments Flow – Air (10 to 300) ml/min 1.3 ml Bios DC-LC-1 100 ml/min to 10 L/min 2.2 ml Bios DCMG1 500 ml/min to 50 L/min 1.7 ml Bios DC-HS-1 Particle – Air 0.1, 0.2, 0.4, 1.0, 2.4 µm 100 % efficiency Comparison to standard filter Viscosity – @ 25 °C (17 to 2000) cst 0.68 % of value Cannon series N fluid (1990 to 200 400) cP 0.52 % of value standards(A2LA Cert. No. 0935.05) 10/27/2011 Page 14 of 17
  15. 15. VII. Mechanical Parameter/Equipment Range CMC2, 7 () Comments Torque3 (0 to 100) in·oz 0.78 % Mountz torque system (0 to 100) in·lb 0.67 % (0 to 100) ft·lb 0.71 % (100 to 1000) ft·lb 1.4 % CDI torque system Scales and Balances3 (1 to 200) mg 0.17 mg Verification with class 1 (1 to 200) g 0.19 mg weights and balance Up to 5 kg 31 mg Up to 30 kg 47 mg (10 to 600) lb 1.0 LSVD Class F weights Mass3 Up to 500 mg 12 μg Class 1 weights and Up to 500 g 1.3 mg balance Up to 30 kg 140 mg Pressure Gages, (-14.7 to 300) psi 0.17 % Fluke 744 w/pressure Transducers, Up to 3000 psi 0.03 % of rng modules, Honesty HX601 Transmitters3 Up to 10 000 psi 0.25 % of rng (0 to 25 000) psi 0.12 % full scale Tachometer3 (5 to 7999) rpm 1.0 rpm DT209X tachometer (8000 to 24 999) rpm 2.0 rpm (25 000 to 99 999) rpm 3.0 rpm Air Velocity3 Up to 8000 ft/min 2.3 % TSI 8360 velocity Force – Compression & (3 to 30 000) lbf 0.4 % Load cell system Tension3 (30 000 to 300 000) lbf 0.4 %(A2LA Cert. No. 0935.05) 10/27/2011 Page 15 of 17
  16. 16. VIII. Optical Quantities Parameter/Equipment Range CMC2, 7 () Comments Optical Power3 – Measure 850 nm (6 to -60) dB 4.9 % Agilent 8163A, 81634, 8156A, 81532 1310 nm (10 to -110) dB 4.9 % 1550 nm (10 to -110) dB 4.7 % Optical Wavelength3 – (700 to 1650) nm 3.9 % Agilent 86120B Measure Fiber Optics Wavelength3 (1510 to 1540) nm 1.5 parts in 106 NIST SRM 2517A – Measuring Equipment Illuminance (10 to 3000) fc 4 % + 2 LSD Standard light meter LSD=least significant digitIX. Thermodynamics Parameter/Equipment Range CMC2 () Comments Humidity – Measuring 11 % RH 1.6 % RH Saturated salt Equipment3 33 % RH 1.7 % RH solutions 75 % RH 1.4 % RH 97 % RH 2 % RH Humidity – Measure3 (0 to 40) % RH 2.1 % RH Vaisala HMP 77 probe (40 to 97) % RH 2.8 % RH Temperature – Measure3 (-40 to 300) ºC 0.2 ºC Azonix A1011 and PRT(A2LA Cert. No. 0935.05) 10/27/2011 Page 16 of 17
  17. 17. X. Time & Frequency Parameter/Equipment Frequency CMC2 () Comments Frequency – Measure, 10 MHz 1 x 10-11 Hz Trembel GPS Fixed Point ____________________________________________1 This laboratory offers commercial calibration service and field calibration service.2 Calibration and Measurement Capability (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. Calibration and Measurement Capabilities represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.3 Field calibration service is available for this calibration and this laboratory meets A2LA R104 – General Requirements: Accreditation of Field Testing and Field Calibration Laboratories for these calibrations. Please note the actual measurement uncertainties achievable on a customers site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC.4 The measurands stated are generated with the Fluke 5500A, Fluke 5700A series of instruments. This capability is suitable for the calibration of the devices intended to measure the stated measurand in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction of the reading plus a fixed floor specification.5 The measurands stated are measured with the HP 3458A series of instruments. This capability is suitable for the calibration of the devices intended to generate the measurand in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a combination of the fraction of the reading/output plus a range specification.6 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches. D is the numerical value of the nominal diameter of the device measured in inches. Pitch diameter is measured by the three-wire method. IV refers to indicated value.7 In the statement of CMC, the value is defined as the percentage of reading. (A2LA Cert. No. 0935.05) 10/27/2011 Page 17 of 17
  18. 18. A2LA has accredited MICRO PRECISION CALIBRATION Batino, Calamba City, Laguna, Philippines for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration Laboratories. This laboratory also meets the requirements of ANSI/NCSL Z540-1-1994 and anyadditional program requirements in the field of calibration. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Presented this 27th day of October 2011. _______________________ President & CEO For the Accreditation Council Certificate Number 935.05 Valid to April 30, 2013 For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.

×