MKS InstrumentsMultiGas 2030 FTIR                MKS Instruments           On-Line Product Group                        Pr...
MultiGas 2030 Features Resolves & analyzes more compounds   – 0.5 cm-1 high resolution FTIR Analysis in 1 second   – (0....
MultiGas Features, continued Maintains permanent calibration   – Calibration supplied with instrument                    ...
MultiGas 2030Hardware Overview
MultiGas 2030 - Top View               Heated Cell        ElectronicsDetector Box       Baratron pressure        Heated Ga...
MultiGas Cell Advantage                                      20/20 Gas Cell                                        – 5.11...
2 cm Gas Cell Used for %-level analysis in particular for SynGas Reactions 255 times less sensitive then 5m gas cell      ...
MG2030 MCT Detectors LN2 Cooled Detectors   – Larger Range:       Greater number of detectable species       500 cm-1 c...
MG2030 Detectors MG2030 offers MCT Detectors  – 5 micron – 16 micron detector ranges  – Selection depends on gas/sensitiv...
Instrument Spectral Accuracy Instrument Accuracy Optimization   – Spectra linearity           Accurate absorbance in the...
Field Analysis Using FTIR Monitoring VOCs   –   CH4 ranges from 500 up to 3000 ppm   –   C2H6 in the hundreds of ppm   – ...
Field Deployable FTIR Advantages  – Multiple species – one instrument         SO2, NH3, NO, HCl, HF, CO, CO2, H2O, and V...
How Can MKS OLT Support You? MKS On-Line Products   – Dedicated to your gas analysis success Numerous Applications   – C...
Thank You!
Upcoming SlideShare
Loading in …5
×

MultiGas 2030 General Overview

1,232 views

Published on

General overview of the MKS Instruments, MultiGas 2030 FTIR.

  • Be the first to comment

  • Be the first to like this

MultiGas 2030 General Overview

  1. 1. MKS InstrumentsMultiGas 2030 FTIR MKS Instruments On-Line Product Group Presented by: Jim Belanger jim_belanger@mksinst.com
  2. 2. MultiGas 2030 Features Resolves & analyzes more compounds – 0.5 cm-1 high resolution FTIR Analysis in 1 second – (0.2 sec for HS version) – High speed FTIR Fastest response – Long path length, small volume gas cell – 5.11 m, 200 mL gas cell High speed detectors for all applications – TE or LN2 cooled MCT detectors No field adjustments required  Provides correction for – Permanently aligned spectrometer pressure fluctuations – 0 – 1000 Torr cap. manometer MKS Confidential 2
  3. 3. MultiGas Features, continued Maintains permanent calibration – Calibration supplied with instrument Instrument to Instrument Precision – Reduces need for gas cylinders – All instruments maintain same Calibration - fixed calibration Sample Detection limits ppb to ppm – All with a single gas cell State-of-the-art spectral analysis – More than 30 compounds simultaneously Full instrument diagnostics – Quickly pinpoint instrument failure – Demonstrates instrument compliance Carbon Monoxide Spectrum MKS Confidential 3
  4. 4. MultiGas 2030Hardware Overview
  5. 5. MultiGas 2030 - Top View Heated Cell ElectronicsDetector Box Baratron pressure Heated Gas inlet measurement MKS Confidential 5
  6. 6. MultiGas Cell Advantage  20/20 Gas Cell – 5.11 m, 200 mL volume – 32 passes through cell – Long path - small volume -->provides fast response – Versions  Ni-coated Al cell  Ni-coated Stainless Steel20/20TM Long Path (5.11m) Gas Cell  Nickeless Stainless Steel – Alignment indexing pads  Mirrors – O-ring “face” seal  Kalrez, Viton, Metal – Corrosive resistant coating – High light throughput  Windows – KBr, MgF2-KBr, BaF2, CaF2 MKS Confidential 6
  7. 7. 2 cm Gas Cell Used for %-level analysis in particular for SynGas Reactions 255 times less sensitive then 5m gas cell MKS Confidential 7
  8. 8. MG2030 MCT Detectors LN2 Cooled Detectors – Larger Range:  Greater number of detectable species  500 cm-1 cut off (16μ) – High Sensitivity: Lower minimum level of detection – Maintenance  12 hour coolant refill require  3-5 days coolant refill with 5L extended dewar TE Cooled Detectors – Narrow Range:  Smaller number of detectable species  2000 cm-1 (5μ), 1350 cm-1 (7.4μ) or 1100 cm-1 (9.2μ) – Highest Sensitivity - 2000 cm-1 (5μ),  Lowest minimum level of detection  Unable to detect species such as NH3 – Maintenance - None MKS Confidential 8
  9. 9. MG2030 Detectors MG2030 offers MCT Detectors – 5 micron – 16 micron detector ranges – Selection depends on gas/sensitivity/range required Detector Sensitivity Comparison Cooling Sensitivity Comparison to DETECTOR Range Coolant Temp (D*) 16u LN2 5000 - 2000 Piezo electric 5 micron -80° C 77.1 e9 1.8x more sensitive cm-1 element (TE) 5000 - 1350 Piezo electric 7.4 micron -80° C 6.9 e9 6x less sensitive cm-1 element (TE) 5000 - 1100 Piezo electric 9 micron -80° C 2.3 e9 18x less sensitive cm-1 element (TE) 5000 - 500 Liquid N2 16 micron -196° C 42.8 e9 Base value cm-1 MKS Confidential 9
  10. 10. Instrument Spectral Accuracy Instrument Accuracy Optimization – Spectra linearity  Accurate absorbance in the whole range of absorbance level – Resolution  Instrument has same resolution (i.e., line width) as the calibration spectra – Line position  Instrument spectra are “lining up” exactly with the calibration spectra Validation – Use transferrable calibration and verify cal cylinder – Still need H2O Calibration on each instrument for CEM – Remove influences from components like CO2 and H2O MKS Confidential 10
  11. 11. Field Analysis Using FTIR Monitoring VOCs – CH4 ranges from 500 up to 3000 ppm – C2H6 in the hundreds of ppm – Propane on the order of 50 ppm and below – Need to speciate to remove Methane and Ethane – Unburned Propane largest VOC contribution after catalyst Monitoring HAPs – Formaldehyde easy to measure by FTIR Conventional Total Hydrocarbon (THC) analyzers – Can not separate Propane from Methane or Ethane – Use Methane Analyzer then subtracts the rest – Not sensitive – Unable to detect all HCs (e.g. formaldehyde) MKS Confidential 11
  12. 12. Field Deployable FTIR Advantages – Multiple species – one instrument  SO2, NH3, NO, HCl, HF, CO, CO2, H2O, and VOCs – Analyze components in high CO2 and H2O – Direct analysis – no chemical conversion or “fudge factors” – Analysis method minimizes interferents – Flexibility in Changing in Method  Customer can easily modify  Transferable calibrations MKS Confidential 12
  13. 13. How Can MKS OLT Support You? MKS On-Line Products – Dedicated to your gas analysis success Numerous Applications – Compliance – Engineering – Ambient air Support Resources – MKS Applications Team – MKS Field Services Team – Outside Applications Team Industry Standard Technology – Field proven rugged FTIR analyzer – Industry leading software and analysis algorithms Financing Assistance Available – Capital partners MKS Confidential 13