Table of Contents
1. Introduction..........................................................................................
3
1. Introduction
Service packs and hotfixes are updates to Autodesk products to resolve a known issue or
workaround.
This...
4
2.1. Download and Installation
1. Check for any update using Autodesk Application Manager as an alert tool. JEC to infor...
5
Network Settings :
2. Download the Autodesk update or hotfix at Knowledge Network
3. Place installation update files at ...
6
4. Before installation, always read the README file. This is very important.
5. Install the update or hotfix by followin...
7
2.2. Testing
The assigned testers to different applications are as follows;
Applications In Charge
AutoCAD JEJ
AutoCAD M...
8
2.3. Roll Out
Once the results have been validated with no issues, the tester will submit a Service Request
Form to Acce...
Upcoming SlideShare
Loading in …5
×

Autodesk Updates and Hotfixes

113 views

Published on

  • Be the first to comment

  • Be the first to like this

Autodesk Updates and Hotfixes

  1. 1. Autodesk Updates and Hotfixes Last edited: April 26, 2016 GEA Process Engineering PE CAD Operation DAWN@gea.com
  2. 2. 2 Table of Contents 1. Introduction................................................................................................................................. 3 2. Procedure ................................................................................................................................... 3 2.1. Download and Installation....................................................................................................................... 4 2.2. Testing .................................................................................................................................................... 7 2.2.1 Test Results....................................................................................................................................... 7 2.3. Roll Out ................................................................................................................................................... 8 3. Appendix..................................................................................................................................... 8 Log File........................................................................................................................................................... 8 Forms ............................................................................................................................................................. 8
  3. 3. 3 1. Introduction Service packs and hotfixes are updates to Autodesk products to resolve a known issue or workaround. This document will guide you in the proper implementation of Autodesk product updates and hotfixes through a testing process. This will be the basis for the actual roll out of product updates. Individual hotfixes and security patches on the other hand should be adopted on a case‐by‐ case, "as‐needed" basis. The majority of security updates released are for client side issues except for Vault Server updates. Evaluate the update, if it's needed, then apply it. If not, assess the risk of applying or not. The basic rules are: "The risk of implementing the service pack, hotfix or updates should ALWAYS be LESS than the risk of not implementing it." And, "You should never be worse off by implementing a service pack, hotfix or updates. If you are unsure, then take steps to ensure that there is no doubt when moving them to production systems." The scope of this task is from the release of Autodesk Service pack or hotfix through an alert from the Autodesk Application Manager until the submission of service request to system administrator. 2. Procedure This section explains the procedure in implementing the Autodesk Product Updates and Hotfixes. The Autodesk applications that need to be tested with updates/hotfixes are as follow; 1. AutoCAD 2. AutoCAD Mechanical 3. AutoCAD Electrical 4. AutoCAD Plant3D 5. AutoCAD P&ID 6. Inventor Professional 7. Navisworks Manage 8. Navisworks Freedom 9. Vault Basic Server 10. Vault Basic Client 11. Vault Professional Server 12. Vault Professional Client
  4. 4. 4 2.1. Download and Installation 1. Check for any update using Autodesk Application Manager as an alert tool. JEC to inform responsible testers (see Table 2.2) Settings Alert Settings:
  5. 5. 5 Network Settings : 2. Download the Autodesk update or hotfix at Knowledge Network 3. Place installation update files at sv42141soe1781 DAWN Test directory
  6. 6. 6 4. Before installation, always read the README file. This is very important. 5. Install the update or hotfix by following the Installation Instructions from README file. 6. Check the About Autodesk from the application. Take note of the build number and log in the information at Table 3.1 Figure 2.1
  7. 7. 7 2.2. Testing The assigned testers to different applications are as follows; Applications In Charge AutoCAD JEJ AutoCAD Mechanical JEJ AutoCAD Electrical JEJ AutoCAD Plant3D JEC AutoCAD P&ID JEC Inventor Professional JEC Navisworks Manage REK Navisworks Freedom REK Vault Basic Server LAR Vault Basic Client JEC,JEJ,REK,LAR Vault Professional Server LAR Vault Professional Client JEC,JEJ,REK,LAR Table 2.2  The assigned tester will test according to the most relevant issue(s) from the description of the issues addressed. An example for Autodesk® AutoCAD® 2016 Hotfix 2 Readme --------------------------------------------------------------------------------------------------------- Issues Resolved by This Update The following issues are addressed by this Hotfix: o Miscellaneous crash issues in DWG files containing attached images; o Miscellaneous issues with DGN Export functionality. --------------------------------------------------------------------------------------------------------- Perform a test for AutoCAD hotfix against crash with attached images and DGN Export.  Record your tests by filling up the Update Test Form. There will be a time when an update may not be needed nevertheless it is necessary to fill up the Update Test Form to state the reason(s). 2.2.1 Test Results If test done is consistent with the issue(s) from the readme file then the tester will assign 2 testers (outside of DAWN) by filling up a Service Request Form. The service request form will contain the test workflow done by the tester. This will serve as a guide for the assigned testers. In case the test did not fulfill the resolved issues, there will be a discussion among DAWN to validate the issue at hand. If the issue cannot be resolved, then it will be escalated to Autodesk Support. LAR or JEJ will coordinate with Autodesk Support.
  8. 8. 8 2.3. Roll Out Once the results have been validated with no issues, the tester will submit a Service Request Form to Accenture for the roll out of Autodesk Update(s). The target roll out date should be agreed upon between parties. ( Add new directory for roll-out - JEJ) 3. Appendix Log File This table is located at the SharePoint site. Version Applicat ion Type Update ID Build # Tested by Checke d by Date Started Date Finishe d Status 2016 Vault Pro DS Upd2 JEC Done 2016 Vault Pro DS Upd1 Not Applicabl e 2016 Inventor Pro Update2 JEC 09/16/201 5 2016 Vault Server Update1 2016 Naviswor ks Manage Update2 JEC 2016 2016 Table 3.1 Forms (Separate Files) Update Test Form

×