Successfully reported this slideshow.
We use your LinkedIn profile and activity data to personalize ads and to show you more relevant ads. You can change your ad preferences anytime.

Limitations of cephalometrics of ceph

2,048 views

Published on

The Indian Dental Academy is the Leader in continuing dental education , training dentists in all aspects of dentistry and
offering a wide range of dental certified courses in different formats.for more details please visit
www.indiandentalacademy.com

Published in: Education
  • Be the first to comment

Limitations of cephalometrics of ceph

  1. 1. SEMINAR ON LIMITATIONS OF CEPHALOMETRICS www.indiandentalacademy.com
  2. 2. CONTENTS 1.INTRODUCTION 2.REVIEW OF LITRETURE 3.CLASSIFICATION OF CEPHALOMETRIC ERRORS 4.PROJECTION ERRORS 5.LANDMARK IDENTIFICATION ERRORS 6.LIMITATIONS IN SUPERIMPOSITION 7.LIMITATIONS OF CEPHALOMETRIC ANALYSIS www.indiandentalacademy.com
  3. 3. CONTENTS 8) LIMITATIONS OF VERIOUS REFERENCE PLANES USED IN CEPHALOMETRICS 9) CONCEPTS OF NATURAL HEAD POSITION AND NATURAL HEAD POSTURE 10) LIMITATIONS OF VARIOUS CEPHALOMETRIC ANALYSIS COMMONLY USED 11) ADVANTAGES & LIMITATIONS OF DIGITAL CEPHALOMETRY 12) CONCLUSION AND BIBLOGRPHY www.indiandentalacademy.com
  4. 4. • Cephalometry, or the measurement of the head, was developed as an anthropological technique to quantify shape and size of skull. The discovery of x-rays by Roentgen in 1895 revolutionized medicine and dentistry. About 36 year later i.e; 1931, traditional cephalometry in two dimensions, known as roentgenographic cephalometry, was introduced to the dental profession by Broadbent and has since remained relatively unchanged. • Since these early years, cephalograms have been used widely as a clinical and research tool for the study of craniofacial growth, development, and treatment. • However, because of the traditional 2-dimensional cephalometry, use of this method for deriving clinical information as a basis for determining treatment plans has been questioned. INTRODUCTION www.indiandentalacademy.com
  5. 5. • The following issues question the validity of 2- dimenstional cephalometry to derive clinical information used in treatment planning. 1) A conventional head film is a 2-dimentional representation of a 3-dimentional object. When 3- dimentional object is represented in 2- dimentions,the imaged structures are displaced vertically and horizontally. The amount of structural displacement is proportional to the distance of the structures from the film or recording plane. www.indiandentalacademy.com
  6. 6. 2) Cephalometric analysis are based on the right assumption of perfect superim - position of the right and left sides about the midsagittal plane. • Perfect superimposition is observed infrequently because facial symmetry is rare and because of the relative image displacement of the right and left sides. • These inherent technical limitations do not produce an accurate assessment of cranio- facial anomalies and facial asymmetries. www.indiandentalacademy.com
  7. 7. 3) The projection geometry prevent the ability to acquire accurate dimensional information aligned in the direction of the x-ray beam. 4) A significant amount of external errors, known as radiographic projection error, is associated with image acquisition. These errors include size magnification, errors in patient positioning, and projective distortion inherent to the film-patient-focus geometric relationships. www.indiandentalacademy.com
  8. 8. 5) Manual data collection and processing in cephalometric analysis have been shown to have low accuracy and precision. 6) Significant error is associated with ambiguity in locating anatomic landmarks because of the lack of well-defined anatomic features, outlines, hard edges and shadows, and variation in patient position. Such landmark identification errors are considered major source of cephalometric errors. Despite these limitations of cephalometry, many cephalometric analyses have been developed to help diagnose skeletal malocclusions and Dentofacial deformities. However, several investigations have questioned the scientific validity of such analyses.www.indiandentalacademy.com
  9. 9. • Pacini in 1922 – described a rather primitive method for the standardization of radiograph imaging of the head. He recommended the positioning of a subject at a fixed distance of 2 mtr from the x-ray source with a film cassette fixed to the head with a wrapping of gauze bandages. • Hofrath of Germany and Broadbent of the United states in 1931- published their own method of obtaining standardized head radiographs. REVIEW OF LITRATURE www.indiandentalacademy.com
  10. 10. • Bjork in 1947 –described errors arising from differences in projection between two films of the same individual. He also noted that the difficulties involved in locating different landmarks varied depending on the nature of the landmark examined. This was confirmed by Richardson 1966- who noted that some landmarks were more reproducible vertically than horizontally and vice versa. • In a study by Van Aken in 1963- projection errors were found to be small but might be of significance in cephalographs of asymmetrical skulls or in the case of anatomical landmarks that do not lie in the midsagittal plane. REVIEW OF LITRATURE www.indiandentalacademy.com
  11. 11. • Baumrind and Frantz in 1971- found that repeated identification of the same landmark on the same cephalometric image resulted in errors and they also studied the side effects of uncertain landmark identification and found these errors were significant when transmitted to angular & linear measurements. • Rossmann & Wiley in1970- claimed that interpretation of radiographic image is dependent on radiological knowledge, pattern recognition , physical image quality. • Bergersen in 1980- studied magnification and distortion in cephalometric radiography and found discrepancies between distance measured on the film and true distances in the object.www.indiandentalacademy.com
  12. 12. CLASSIFICATION OF CEPHALOMETRIC ERRORS www.indiandentalacademy.com
  13. 13. Some limitations of cephalometrics According to Moyers 1) Assumptions a) Symmetry b) Occlusal position c) Orientation on the transmeatal Axis d) Adequacy of one or two planar projections 2) Fallacies a) The fallacy of false precision b) The Fallacy of ignoring the patient c) The fallacy of super- positioning d) The fallacy of Using Chronological Age e) The fallacy of the “ideal” 3) Misuses of cephalometric analyses www.indiandentalacademy.com
  14. 14. Geometric methods I) Basic elements : A tracing has some actual biological information, namely, location of curves and landmarks. It also contains some non biological information-artifacts-such as non- curves and non-points. A) Curves: The curved images in the cephalogram are of three different biological types (i) edge regression (ii) curves in space (iii) transversals of surfaces. i) Edges of regression surfaces –the edges of surfaces are sometime properly shown. The anterior border of the coronoied process, for instance, really is a fairly sharp edge.www.indiandentalacademy.com
  15. 15. • But sometime that which we perceive as an edge of a surface is neither an edge nor a horizon. For e.g., the line we call the “alveolar crest” line represents a col, a saddle-shaped depression in the crest of a mountain ridge. www.indiandentalacademy.com
  16. 16. ii) Curves in space In a cephalogram curves are seen but are foreshortened and simplified by flattening; for e.g. the image of the mandibular canal in cephalogram and the resulting image in not realistic. www.indiandentalacademy.com
  17. 17. iii) Transversals of surfaces: • Transversals of surfaces are neither edges nor true anatomic loci but places where a bone of irregular shape is viewed most parallel to the central ray. Some surfaces are nearly parallel to the central ray and hence appear as a line, a problem inherent in reducing 3-dimensions in to two. www.indiandentalacademy.com
  18. 18. • For e.g. , the radiographic shadow of the bony orbit in cephalograms and real bony orbit on a dry skull. www.indiandentalacademy.com
  19. 19. B) Points& landmarks classified A landmark is a point serving as a guide for measurement. Cephalometric landmarks are of the following kinds; a) True anatomic point- anatomic points are really small regions which might be located on the solid skull even better than in the cephalogram. e.g.- ANS, infradentale, cusp tips/ incisal edges, nasion, www.indiandentalacademy.com
  20. 20. b) Implants- implants are artificially inserted radiopaque markers, usually made of an inert metal. They are not landmark in the usual sense . They are private points their position from subject to subject is not homologous. They may be located more precisely than traditional point and provide precise superpositioning, but they cannot be used to measure accurately any aspect of the single form.www.indiandentalacademy.com
  21. 21. c) External points - Are points characterized by their properties relative to the entire outline: a) points which are extrema of curvature, for e.g. incision superius (Is) (b) points whose coordinates are largest or smallest of all points on a specific outline ,for eg point A, point B, gnathion, condylion. These points are less precision of location than true anatomic points. www.indiandentalacademy.com
  22. 22. d) Intersection of edges of regression as points – points defined as the intersection of images are really lines looked at down their length. For e.g., articulare (Ar) and PTM are not points at all and are in no way part of the solid skull. Such points exist only in projections and are dependent on subject positioning. e) Intersection of constructed lines –intersections of constructed lines are used as points for e.g. : “gonion” some times is defined as the intersection of the ramal and mandibular lines. www.indiandentalacademy.com
  23. 23. C) Lines / planes: • In reality many of the so called cephalometric planes are not flat. For e.g., the occlusal plane drawn in the cephalogram as a straight line represents a very complicated 3-dimensional relationship of cusp contacts. Cephalometric lines usually of the following types: i) Line joining true anatomic points, for e.g. ,the palatal line joins the ANS-PNS . www.indiandentalacademy.com
  24. 24. ii) Anatomic tangent lines: • Lines through an anatomic point and tangent to an outline elsewhere. For e.g., the facial line is defined as joining nasion to pogonion; but the Pog is just the point of tangency of this line at the chin. • Lines formed by double tangents, that is, lines tangent to a structure, or structures, at two points. For e.g. , the ramal line usually touches the mandible both at the posterior border of the ramus and along the condyle; the mandiular line touches both near menton and near gonion. www.indiandentalacademy.com
  25. 25. I) Assumptions In any method some things must be taken for granted as a basis for action. a) Symmetry • Analysis, particularly in the lateral projection, is based on presumed skeletal symmetry. • All faces have minor asymmetries which are clinically unimportant, but more serious imbalances may be obscured by the method or neglected by the dentist. • Routine study of the PA projection is a good antidote. www.indiandentalacademy.com
  26. 26. b) Occlusal position • Cephalograms must be taken in some occlusal position. It is conventional to position the mandible in the usual occlusal position when taking the cephalograms since this is where the patient “bites”. • In malocclusions with an important functional element this convention may be misleading. One should study carefully the patient’s mandibular functional movements prior to recording the cephalogram. Suspicions noted visually may be confirmed quantitatively in the cephalogram by two procedures; www.indiandentalacademy.com
  27. 27. • Use wax bites of both the usual occlusal position ( centric occlusion) and the detruded contact position (centric relation) to record two lateral cephalograms. In extreme cases the patient may wear a diagnostic splint for several days before the cephalogram is obtained. • Use the postural position as well as an occlusal position for both the lateral and PA projections.www.indiandentalacademy.com
  28. 28. c) Orientation on the transmeatal Axis • It is convenient to use ear rods to orient the patient’s head. The central ray is supposed to pass along the transmeatal axis. But of course the external auditory meati are just asymmetric as any other cephalic structures. • Special cephalometric procedures have been designed without ear rods so the central ray is 90 degrees to the midsagittal plane, but they are not in common use. www.indiandentalacademy.com
  29. 29. d) Adequacy of one or two planar projections: Almost all routine cephalometric analysis is done using only the lateral projection. Much can be learned from PA , oblique, and basilar views. The future may bring a practical true 3- dimensional cephalometric method. www.indiandentalacademy.com
  30. 30. 2) FALLACIES Any method may involve specific miscalculation, omissions, blunders, oversights, errors, or inaccuracies which are not the fault of the method itself. We speak hear not about such mistakes but about fallacies: misrepresentations intrinsic to the method. a) The fallacy of false precision If one makes a series of separate cephalograms of the same head, traces each cephalogram, locate “A” point , nasion, and “B” point , and measures the ANB angles, it will be discovered that the standard error of that measure is greater than 1.5 degrees. www.indiandentalacademy.com
  31. 31. • Therefore, any decision, such as a choice of treatment procedure, based on the value of ANB angle, alone or in combination with other measurements, must have a gray area of approximately +/- 1.5 degrees where the treatment prescription is ambiguous. • This problem is compounded when a clinician compares a case he or she has traced to standards developed, and therefore filmed and traced, by another. www.indiandentalacademy.com
  32. 32. b) The Fallacy of ignoring the patient • Means are population averages which have nothing to do with the specific characteristics of particular patient. A patient’s measure need not to be increased by , for e.g., 4mm just because it differs by 4mm from the mean. www.indiandentalacademy.com
  33. 33. •There are many beautiful faces in good occlusion which have measures far from the norms. It is not necessary to treat malocclusion with relation to a fixed cephalometric goal. •Rather, cephalomerics should provide a range of satisfactory treatment goals which, combined with other information from dental casts ,case history, and observation of the patient, make possible an individualized treatment plan. www.indiandentalacademy.com
  34. 34. c) The fallacy of super- positioning: Super positioning , registering of two or more tracing of an individual on particular structures ,occasionally helps one to visualize growth or treatment changes. • Localized remodeling can be shown by superposition's nearby. As one moves away from the registration site the changes observed are a combination of summated growth in several regions, effect of treatment, enhancement of errors in positioning. www.indiandentalacademy.com
  35. 35. • For e.g., where registration is in the cranial base region, the chin seems to have “grown” downward & forward, but one may as well say that the condyle has been growing upward & the chin has been translated away from the articular fossae. Little growth occurs at the chin itself. The many changes b/w chin & sella are summated & directed downward & forward not by growth but by the artifact of super- positioning. • If one superposed on the symphysis, it would be misleading to speak of upward & backward growth of the cranial base. www.indiandentalacademy.com
  36. 36. www.indiandentalacademy.com
  37. 37. www.indiandentalacademy.com
  38. 38. d) The fallacy of Using Chronological Age Although it is conventional to use chronological age (birth age) for comparisons and reference, developmental age is a better criterion: it reduces the variance of sizes, angles and proportions within age classes. Some orthodontists take routine radiographs of the wrist of patients to assign their “ carpal age” an index of bone maturation. www.indiandentalacademy.com
  39. 39. e) The fallacy of the “ideal” Practical problems arise when “ ideals” for skeletal relationships are oversimplified into numbers inflexibly and arbitrarily imposed on every patient. The use of contrived “ideals” as standards sometimes produces a set of ipso facto findings by setting up artificial criteria for abnormality and then uncovering the incidence and prevalence of these variations. www.indiandentalacademy.com
  40. 40. • By definition, abnormal must always refer to the normal, which can only be determined from an appropriate population. • One cannot discover “abnormality” by comparison with subjective ideals based on personal perceptions of facial esthetics, nor can one label such ideals as normal. www.indiandentalacademy.com
  41. 41. 3) Misuses of cephalometric analyses • Even when we protect ourselves from misleading assumptions or fallacious misconceptions we may err simply by misuse of any analysis. a) An analysis is misused if too rigid an application of mean values is made. The total range and variance are more practical than the mean itself. Because means are population averages, they usually are very poor treatment goals. • Occasionally means of tooth positions are useful, but only when the array of skeletal values is close to the means for sex and age. When skeletal values deviate from the mean, dentitions must adapt. The clever clinician does not apply the same mean value to all faces but determines those adaptation compromises to be made in treatment which are most suitable to be pleasing and stable.www.indiandentalacademy.com
  42. 42. b) An analysis is misused when it is applied inappropriately. • Values derived from 12-year old North American white boys who sought orthodontic treatment in a dental school, for e.g. are obviously of little use in assessing the specific clinical needs of a 6-year old black girl in practice: there are too many differences resulting from age, sex, race, etc • The samples from which many of our most popular cephalometric analyses were derived have not been adequately described in the literature, making it very difficult for the clinician to know whether or not the analysis is appropriately useful.www.indiandentalacademy.com
  43. 43. c) An analysis is misused when it is applied in a way for which it was not intended. Analyses contrived to visualize treatment goals (e.g. those of Tweed or Steiner, both designed to depict goals of treatment )are used improperly when used for growth studies. d) Standards derived from cross-sectional samples, in most instances, cannot properly be used in lieu of longitudinal data to access expected growth. For establishing growth standards, a small serial sample is much better than cross-sectional sample having the same number of radiographs.www.indiandentalacademy.com
  44. 44. e) The substitution of a subjectively derived “ideal” for a statistically developed population norm misinforms and misleads. •“Ideals” represent artificial constructs of faces one clinician likes; norms present real values of a particular group. They cannot be used interchangeably. www.indiandentalacademy.com
  45. 45. According to Baumrind and Frantz; AJO -1971, Head film measurements like all measurements involve error which falls into two categories. • Errors of Projection • Errors of Identification www.indiandentalacademy.com
  46. 46. Hatcher recently has reviewed and categorized source of errors include those caused by internal and external orientation and those related to geometry and association. 1) INTERNAL ORIENTATION ERROR : • This error refers to the 3-dimentional relationship of the patient relative to the central x-ray beam or imaging device and assumes that a minimal error of this type occurs with a specific and consistent head position. Because this is not always true, an internal orientation error is introduced.www.indiandentalacademy.com
  47. 47. 2) EXTERNAL ORIENTATION ERROR : • This error refers to the 3 dimensional spatial relationship or alignment of the imaging device, patient stabilizing device, and image recording device. • Minimal error is assumed when the x-ray source is 60 inches from the midcephalostat as the central ray passes through the ear rods and the beam is horizontal to the horizon and perpendicular to the film plane. • The distance from the midcephalostat plane to the film plane should be known and be consistent between images. Any deviations from these assumptions will introduce errors into the final image. www.indiandentalacademy.com
  48. 48. 3) GEOMETRIC ERROR: •This error primarily refers to the differential magnification created by projection distance between the imaging device, recording device, and a 3- dimensional object. For e.g. ; structures farthest from the film will be magnified more than objects closer to the film. The error is related to the divergence of the x-ray beam on its path from the x-ray source to the recording device. www.indiandentalacademy.com
  49. 49. 4) Association error: • This error refers to the difficulty in identifying a point in two or more projections acquired from different points of view. The difficulty in identifying the identical point on two or more images is proportional to the magnitude of change in the angle of divergence between the projections. www.indiandentalacademy.com
  50. 50. PROJECTION ERRORS www.indiandentalacademy.com
  51. 51. Errors of projection • Results because headfilm is a two dimensional depiction of a three dimensional object. • Since the rays that produce the image are not parallel and originate from a small source , headfilms are subject to distortion; the side nearer the x-ray source is enlarged more than the side closer to the film. www.indiandentalacademy.com
  52. 52. • The degree of magnification is determined by the ratio of the x-ray source-to-object distance and source to film distance. The larger the distance from the source being imaged to the film plane, the greater the magnification. • To minimize this effect, the distance from the x-ray source to the midsagittal plane of the patient’s head in cephalometric unit is 60 inches. This ensures that the x-ray photons are traveling toward the object/film more parallel to each other, thus reducing magnification.www.indiandentalacademy.com
  53. 53. • However, there is still magnification of most of the oral and craniofacial structures ranging from near zero for objects close to the film and in the exact center of the x-ray beam to 24% at regions 60 mm from the ear rods and beyond. This magnification is not constant for all of the possible sagittal radiographic planes of the patient. www.indiandentalacademy.com
  54. 54. • Those structures located closest to the film will be magnified less than those located in the sagittal plane, and those nearest to the x-ray source will be magnified to the greatest extent. • Magnification factors are further affected by the distance from the film cassette to the midsagittal plane of the patient, with magnification increasing as the film is moved away. www.indiandentalacademy.com
  55. 55. • To minimize variation in magnification from patient to patient and to obtain consistent measurements on the same patient over time, many orthodontists choose to keep that distance constant. • A distance of 15 cm from the midsagittal plane of the cephalostat to the film cassette is often used. This fixed distance produces magnification that is somewhat consistent, with in tolerable limits. • However many practitioners choose to place the film cassette as close to the patients head as possible to achieve maximum sharpness and reduce magnification of the dental structures.www.indiandentalacademy.com
  56. 56. • Note that because the x-ray beam is diverging, the image magnification will be less when placing the film at position (A) than will be the case at position (B).www.indiandentalacademy.com
  57. 57. For eg : if the x-ray beam enters the patients head from the right side ,the image of the right side of the mandible will be larger than that of the left side. Also, a given anatomic structure, such as the angle of the right mandible, will appear further from objects in the center of the orofacial image than will be the angle of the left mandible.www.indiandentalacademy.com
  58. 58. • Errors due to the projection of the 3-dimensional object on to a 2-dimensional film have been studied less extensively. • Similarly, there has been little analysis of errors arising from misalignment b/w the different components of the cephalometric equipments or misalignment of the patient in the cephalogrpic system. • In a study by Van Aken(1963) projection errors were found to be small but might be of significance in cephs of asymmetrical skulls or in the case of anatomical landmarks that do not lie in the mid-sagittal plane.www.indiandentalacademy.com
  59. 59. • Bergersen-1980- studied magnification and distortion in cephalometric radiography and found discrepancies b/w distance measured on the film and true distance in the object. • According to Ahlqvist the relations b/w the different components of the cephalographic system are affected by a number of factors. 1.The focal spot, the cephalostat, and the film may be linearly displaced in relation to each other. 2.The cephalostat and the film may be rotated with respect to each other. 3.The patient may be linearly displaced and /or rotated in relation to the cephalographic system. www.indiandentalacademy.com
  60. 60. Fig-A- direction of possible misalignments of the patientwww.indiandentalacademy.com
  61. 61. Fig-B : the projection length of an object will vary with its inclination toward the focal spot or toward the film.www.indiandentalacademy.com
  62. 62. ERROR IN CEPHALOMETRIC LANDMARK IDENTIFICATION www.indiandentalacademy.com
  63. 63. Error of identification • Involves the process of identifying specific landmarks on headfilms. • To test landmark identification reliability , 4 instructors and 3 orthodontic residents were requested to select and plot four high quality radiographs. • They were provided with a list of landmarks and definitions of each and were asked to identify them using a pencil point on a clean sheet of acetate paper on the radiograph. www.indiandentalacademy.com
  64. 64. • The porion, condylion , orbitale and basion were less readily identified than some of the other landmarks. • Condylion was less readily identified and Gnathion more accurately identified. • Baumrind and Frantz demonstrated marked differences in magnitude and configuration of envelope of error found among different landmarks. Other factors that can influence landmark identification are film density and sharpness. www.indiandentalacademy.com
  65. 65. •Identification of landmark by seven individuals. Each circle is the smallest possible circle that would encompass the landmarks.www.indiandentalacademy.com
  66. 66. Point A revisited – Jacobson- AJO 1980 • Subspinale or point A is a midline point whose relationship to the anterior teeth in lateral ceph may be influenced by head position. It is located somewhere b/w the root apex and the coronal third of the root of the tooth. • Subspinale is defined anthropologically as “ the deepest midline point on the premxilla b/w ANS & prosthon. • Bjork defined it as the “ deepest point on the contour of the alveolar projection b/w the spinal point and prosthion. • Because of the difficulty in locating point A, alternate point have been suggested by Van der Linden i. e point L, which is located on the anterior surface of the image of the labial lamella at the region of the apex of the maxillary incisors. • Jarabak & Fizzel defined a point 2 mm ahead of the root apex as a redefinition of point A.www.indiandentalacademy.com
  67. 67. Point A revisited – Jacobson- AJO 1980 • Jacobson concluded that Point A cannot be accurately identified in all cephalometric radiographs. In instances where this landmark is not clearly discernible, an alternative means of estimating the anterior extremity of the maxillary base is shown. • A point plotted 3.0 mm. labial to a point between the upper third and lower two thirds of the long axis of the root of the maxillary central incisor was found to be a suitable point (estimated point A) through which to draw the NAE line and one which most closely approximates the true NA plane. www.indiandentalacademy.com
  68. 68. The precision with which any landmark may be identified depends on a number of factors. 1. Landmarks lying on a sharp curve or at the intersection of two curves are generally easier to identify than points located on flat or broad curves. 2. Points located in areas of high contrast are easier to identify than points located in areas of low contrast . 3. Superimposition of other structures, including soft tissue over the area of landmark in question, reduce the ease of identification. www.indiandentalacademy.com
  69. 69. 4) Precise written definitions of describing the landmark reduces the chance of interpretation error. 5) Operator experience is an important factor since increased knowledge of anatomy and familiarity with the radiographic appearance of the subject reduces interpretive errors. www.indiandentalacademy.com
  70. 70. LIMITATIONS OF SUPERIMPOSITION www.indiandentalacademy.com
  71. 71. LIMITATIONS OF SUPERIMPOSITION • Serial radiographic cephalometry has been used, almost from its inception, to measure craniofacial growth and treatment changes. • This gives rise to the question, just how accurate are cephalometric measurements? Radiographic cephalometry is only scientific if it can be measured. • The validity of cephalometric measurement therefore is directly dependent on the accuracy of the method of measurement, which in turn is limited by the following problems. www.indiandentalacademy.com
  72. 72. A) Lateral or frontal headfilms taken at different times, and possibly by different people, are difficult to reproduce with any degree of accuracy, whether the head is steadied in a cephalostat or in the natural head position. B) The double images of the bilateral structures often are not consistently equally spaced in serial headfilms because of even minor faulty head positioning. www.indiandentalacademy.com
  73. 73. C) Film contrast and density differences often encountered are the result of lack of strict quality control. D) Anatomic or structural landmarks are not consistently identifiable. E) Most important limitation of traditional cephalometric radiographic measurements is that 3-dimensional changes are measured in only two dimensions. www.indiandentalacademy.com
  74. 74. Limitations of traditional superimposition methods • No points or planes in the craniofacial complex are stable and all move relative to each other during growth. Orthodontic analyses, in effect , relates relatively stable areas as depicted by arbitrarily selected points or planes to more remote but less stable landmarks. www.indiandentalacademy.com
  75. 75. • While the primary errors are biologically induced , the secondary errors are entirely mathematically defined, since they are related to the primary errors. • Errors in tracing superimposition can be compounded by the method of superimposition used in interpreting the findings. • A study conducted by Ghafari et al demonstrated differences in interpretation of facial changes by comparing four traditional cephalometric methods of superimposition on the cranial base: best fit on anterior cranial base anatomy, sella-nasion, registration of point R with Bolton-nasion planes parallel, and basion- nasion plane. www.indiandentalacademy.com
  76. 76. • The results of their study showed differences among all paired methods to be statistically significant. • Growth behavior of an individual as recorded on a sequential set of roentgenograms has been shown to differ greatly when studied using different superimposition methods. Nothing is known of the growth behavior of the individual parts in the continuum of the discrete points studied. • Because of the inability of conventional cephalometry to understand curved forms, it is limited to landmark indices. www.indiandentalacademy.com
  77. 77. LIMITATIONS OF CEPHALOMETRIC ANALYSIS www.indiandentalacademy.com
  78. 78. 1) Most individuals with Dentofacial deformities have anatomic variations in the location of the cephalometric landmarks used as a baseline in many analyses, such as sella, nasion, and orbitale. This often results in incorrect conclusions from the analysis. 2) The clinician must not base interpretations on single cephalometric measurements. 3) The clinician must recognize the limitations, as well as the advantages, of cephalometry and be sure to integrate measurements with clinical findings. Limitations of cephalometric analysis www.indiandentalacademy.com
  79. 79. 4) The art of cephalometric interpretation lies in understanding abnormal findings and identifying the etiologic factors behind these cephalometric abnormalities in patients with dentoskeletal deformities. 5) Although cephalometric analysis forms an important part of the database for diagnosis and treatment planning, it should not take precedence over the clinical evaluation of the patient. www.indiandentalacademy.com
  80. 80. Reliability of cephalometric analyses: • Fundamental to orthodontics is the need to determine the relationship of the various skeletal components, particularly those of the jaws to each other and to the rest of the cranium in the cranio facial complex. • The interpretation of the measurements continues to be the subject of much debate. www.indiandentalacademy.com
  81. 81. • Wylie et al compared five analyses in ten individuals who underwent various surgical corrections. • Pre treatment cephalometric radiographs of the ten patients were selected to illustrate different Dentofacial deformities , each of which was corrected with a different surgical procedure. • The pretreatment cephalometric radiographs were blindly assessed by one investigator who used the criteria for each of five popular analyses. • The results of the analyses ( diagnoses ) were then compared to one another and to the actual surgery performed. www.indiandentalacademy.com
  82. 82. • The outcome of the study revealed that performance of the analysis in relation to actual surgery was generally poor. • In the case with mandibular advancement there was 35 % agreement with the surgery performed. • For maxillary advancement - 20 % • For maxillary superior positioning 100% • For maxillary advancement and mandibular reduction- 20% • For bimaxillary protrusion – all analyses agreed that the teeth were protrusive and that the lower third of the face was too long. • This illustrates the unreliability of cephalometric analyses.www.indiandentalacademy.com
  83. 83. For e.g.; 1) In class III malocclusion, 2 analyses suggested mandibular protrusion, 2 determined that the maxilla was retrognathic, and one identified the problem as a “short” maxilla and “forward mandible”. • In class II, div 2 malocclusion, one analyses claimed that the skeletal pattern was class I, 3- analyses indicated that class II tendency was due to maxillary protrusion, and one noted a short mandible. Only one analyses would support the decision to surgically advance the mandible.www.indiandentalacademy.com
  84. 84. LIMITATIONS OF VERIOUS REFERENCE PLANES USED IN CEPHALOMETRICS www.indiandentalacademy.com
  85. 85. Reference planes •A cephalometric evaluation of the craniofacial complex requires a plane of reference from which to asses the location of various anatomic structures. Traditionally two planes have been used, namely the sella tucica-nasion(SN) plane and the Frankfort horizontal(FH). • The SN plane is more suitable for assessment of changes induced by growth and/or treatment within the same individual over time. Low variability in identifying sell turcica and nasion is an advantage of using this plane , as is the fact that sell turcica and nasion represent midsagittal structures. www.indiandentalacademy.com
  86. 86. • If the goal is to compare a particular individual to a certain population group (ie; established norms), use of the SN plane may provide erroneous information if the inclination of this plane is either too high or too low. • A sella turcica positioned to a great extent superiorly or inferiorly would account for a low or high inclination of the SN plane, respectively. • Frankfort horizontal (FH) has also been used extensively in cephalometry. Despite the difficulty in locating porion reproducibly, FH has been advocated to more accurately represent the clinical impression of jaw position. www.indiandentalacademy.com
  87. 87. • As an alternative, Legan and Burstone suggested using a constructed horizontal (cHP). This is line drawn through nasion at an angle of 7 degrees to the SN line. • This constructed horizontal tends to be parallel to true horizontal. However, in those cases in which SN is excessively angulated, even the constructed horizontal would not approximate true horizontal, in which case an alternative reference line must be sought.www.indiandentalacademy.com
  88. 88. • Another approach involves obtaining the cephalogram with head in the natural head position. “True horizontal” is drawn perpendicular to a plumb line on the radiograph. Finally, a vertical reference line cane be traced passing through subnasale (SnV) or glabella. • This approach offers the advantage that natural head position approximates the position in which clinical judgments are made. • Its drawbacks include strict adherence to technique and difficulty in conducting studies where cephalograms have been obtained from various facilities.www.indiandentalacademy.com
  89. 89. www.indiandentalacademy.com
  90. 90. Variability between the optic plane and Frankfort horizontal:Tremont-AJO-DO;1980 • Frankfort horizontal is commonly constructed on a lateral cephalogram from the top of the ear rod to orbitale. Ear rod positioning and identification of orbitale present obvious variables with such a reference plane. The optic plane has been proposed as a more accurate representation of Frankfort horizontal. www.indiandentalacademy.com
  91. 91. • The optic plane was constructed, as defined by Sassouni, by drawing the supraorbital plane (a line tangent to anterior clinoid and the roof of the orbit), drawing the infraorbital plane (line tangent to the inferior of sella turcica and the floor of the orbit), and then bisecting the angle formed by their intersection to obtain the optic plane. www.indiandentalacademy.com
  92. 92. • The optic plane, was significantly different from anthropologic Frankfort horizontal. Also, the optic plane did not vary significantly less from anthropologic Frankfort horizontal than from ear rod to orbitale Frankfort horizontal. • According to the parameters of this study, the optic plane is not a more accurate or reliable method of representing anthropological Frakfort horizontal on lateral cephalograms. www.indiandentalacademy.com
  93. 93. • Traditionally, intracranial reference lines have been used for clinical cephalometric analysis of malocclusion cases. Several authors have, however, questioned the validity of intracranial reference because of their variability to the horizontal plane, related to the head in natural head position (NHP). • The study was undertaken to determine the reliability of the FH as a cephalometric reference line. The main alternative to intracranial reference lines is the nonvariable extracranial horizontal line (HOR) related to the head in natural head position. Frankfort horizontal basis for cephalometric analysis Lundström and Lundström- AJO 1995 www.indiandentalacademy.com
  94. 94. fig shows- extreme difference with regard to inclination of frankfort horizontal in natural head position. www.indiandentalacademy.com
  95. 95. • They concluded that no difference was found between the variability of the Frankfort horizontal and the sella-nasion line with regard to the horizontal plane. The large variation of both intracranial reference lines, related to NHP, as well as to NHO, confirms their relative unsuitability as cephalometric references for clinical purposes. • Findings indicate that a horizontal line, related to natural head position, adjusted to natural head orientation when indicated, presents the most reliable basis for cephalometric analysis. www.indiandentalacademy.com
  96. 96. Fig showing- angles b/w horizontal plane and frankfort horizontal (FH/HOR, negative) and S-N line (S-N/HOR, positive)www.indiandentalacademy.com
  97. 97. CONCEPTS OF NATURAL HEAD POSITION AND NATURAL HEAD POSTURE www.indiandentalacademy.com
  98. 98. NATURAL HEAD POSITION • Natural head position is a standardized and reproducible orientation of the head in space when one is focusing at a distant point at eye level. • German Anthropological society in 1884 – Frankfort Agreement ie, The plane which passes through the left and right porion landmarks and the left orbitale, to achieved uniformity in craniometric research. www.indiandentalacademy.com
  99. 99. • The Frankfort horizontal is a useful compromise for studying skulls but not for orienting natural head position in the living because the F-H plane located in the living is normally distributed around a true extracranial horizontal. • Nonetheless, orthodontist dealing with living subjects, rather than inert crania, have used this Frankfort horizontal faithfully in cephalometry. www.indiandentalacademy.com
  100. 100. Downs had shown that discrepancies b/w cephalometric facial typing and photographic facial typing disappear when the Frankfort plane is not horizontal, but tilted up or down. www.indiandentalacademy.com
  101. 101. • Bjerin and Thurow pointed out that intracranial landmarks are not stable points in the cranium, their vertical relationship to each other is therefore also subjected to biological variation. fig shows-Two ceph tracings with similarity in their facial profiles exhibit marked difference in the slope of their skull base( SN line) and in the FH. Conventional ceph analyses utilizing these intracranial reference lines would show markedly divergent facial configuration, rather than the similarity observed clinically.www.indiandentalacademy.com
  102. 102. • Bjorks studies of facial prognathism also illustrates the unreliability of intra cranial reference lines on cephalograms. • Two adult Bantu men were selected to represent maximum and minimum facial prognathism relative to the S-N plane. www.indiandentalacademy.com
  103. 103. • This fig- shows the same two Bantu men tracing aligned in natural head position illustrate nearly identical profile outline and a low and high inclination of the S-N line, rather than difference in prognathism. • When various methods of cephalometric analyses are applied to the study of the same cephalogram, results may differ dramatically depending on the choice of reference lines. www.indiandentalacademy.com
  104. 104. •The simplest procedure to obtain facial photographs and head radiographs is to instruct patients to sit upright and look straight ahead to a point at eye level on the wall in front of them. • The conventional use of two ear rods to stabilize the head in radiographic cephalometry is based on the assumption that the transmeatal axis of humans is perpendicular to the mid sagittal plane. • The relationship of the left and right ears in their vertical and horizontal relation is frequently asymmetric. www.indiandentalacademy.com
  105. 105. Fig-A Fig-B Fig-C Fig-A : Facial symmetry of eyes, ears, contour of the lips, and mandible. Fig-B : Asymmetry of eyebrows and lips, but transmeatal axis perpendicular to the facial midline. Fig-C : Marked asymmetry of eyes, eyebrows, and ear but symmetry of lips. www.indiandentalacademy.com
  106. 106. www.indiandentalacademy.com
  107. 107. • The insertion of ear rods will obviously result in vertical and/or horizontal rotation of the head, which introduces a deficient and misleading image. • There by, the attempt to determine facial asymmetry of a patient generally results in a compromise rather than as an exact definition. • Only the left ear rod should be used in radiographic cephalometry both for the lateral and frontal projection. • The right ear rod should merely be inserted against any part of the ear.www.indiandentalacademy.com
  108. 108. CONCEPTS OF NATURAL HEAD POSTURE • In the later part of the 19th century, many anthropologists believed that the study of cranial morphology necessitated the orientation of skulls to a position that approximates the natural head posture of living beings. • The concept of natural head posture (NHP) on the living subject was introduced into the orthodontic literature in the 1950s by Broca, an anatomist, described NHP as the position of the head attained when an individual stands with the visual axis in the horizontal plane. • Cooke and Wei defined NHP as the natural, physiologic position of the head that is assumed when a relaxed subject looks at a distant reference point.www.indiandentalacademy.com
  109. 109. • Various methods have been devised to obtain NHP • MIRROR METHOD by Moorees and Kean. • SELF BALANCE METHOD by Solow and Tallgren. • The term natural head position and head posture are not interchangeable, one being a standardized procedure applied to all individuals for analysis of Dentofacial morphology and the other i.e.; head posture is an individually characteristic physiologic posture of the head to study the relation b/w posture and morphologic features. www.indiandentalacademy.com
  110. 110. • Note that only a small mirror should be used to record natural head position to force subject to look straight ahead into the image of their eyes rather than a long mirror that prevent standardization of head position. • A long mirror is needed to accommodate subjects when recording their postural position, which is an individual, nonstandardized head position. www.indiandentalacademy.com
  111. 111. • The various reference lines still compete with each other. One system is more or less as good or poor as any other and none is completely reliable because each is subject to large individual variability. • What can be done to diminish this problem? The answer is to choose measurements that are based on different reference planes, in this way it is hoped to compensate for pronounced variations in one or the other reference lines. www.indiandentalacademy.com
  112. 112. LIMITATIONS OF VARIOUS CEPHALOMETRIC ANALYSIS COMMONLY USED www.indiandentalacademy.com
  113. 113. ANB angle as a measure of jaw Dysplasia • According to Steiner, the SNA reading indicates whether face protrudes or retrudes bellow the skull. Although the ANB is a reliable indication of A-P jaw relationship in most instances, there are many situations in which this reading cannot be relied on. • The ANB angle in normal occlusions is generally 2 degrees. Angle greater than this mean value indicate tendency toward class II jaw disharmonies; smaller angles (negative readings) reflect class III jaw discrepancies. While this is an acceptable generalization, numerous instances exist in which this does not apply. www.indiandentalacademy.com
  114. 114. For eg – in fig A lateral ceph tracing of a class II malocclusion. The ANB angle is 7 degrees, which high and it is typical for class II type malocclusion. fig –B; lateral ceph tracing of a normal occlusion in which the ANB angle also measures 7 degrees.www.indiandentalacademy.com
  115. 115. Cephalometrics for you and me – Steiner – 1953 ;AJO • Porion and Orbitale are not accurate for our use as we are not dealing with dry skulls. • Points S and N are clearly visible in the X- ray pictures and can be located easily and accurately. • Emphasizes that points S and N are located in the mid sagittal plane of the head and therefore they are moved a minimum amount whenever the head deviates from the true profile position and that the points are located on hard non yielding tissue. www.indiandentalacademy.com
  116. 116. • The same holds true for a rotation of the occlusal plane: backward (counterclockwise) rotation of the occlusal plane has a decreasing effect on the ANB angle, though sagittal basal relationships remain constant. www.indiandentalacademy.com
  117. 117. Fig A- normal occlusion with an ANB angle of 2 degrees. Fig B- denture base are retro- positioned in the craniofacial complex. This has the effect of reducing the ANB from 2 degrees to -2 degrees. The relationship of the jaws to each other remains unchanged. Fig C- same relationship of the jaws only now both jaws are positioned forward relative to nasion. This has increased the ANB angle from 2 degrees to 5 degrees. www.indiandentalacademy.com
  118. 118. • In fig B- the relation of the jaws to each other is unchanged, but the jaws are rotated in counterclockwise direction relative to the S-N plane as compared to fig A. The rotation had the effect of producing a class III type jaw relationship. The ANB angle has been reduced from 2 degrees to -5 degrees. • Fig C- A clockwise rotation of the jaws produce the opposite effect.( i.e., class II-tape jaw relationship) www.indiandentalacademy.com
  119. 119. Fig shows effect on ANB angle of change of 0.5 inch in position of nasion with points A & B held constant. Fig 1- horizontal positioning of nasion results in different ANB angles 1=2degrees,2=8degrees , 3= - 4. 5degrees Fig 2- vertical positioning of nasion results in different ANB angles. 1=2degrees, 2=1degree, 3=0degreeswww.indiandentalacademy.com
  120. 120. Shortcomings of ANB angle • Taylor in 1969 pointed out that ANB angle did not always indicate true apical base relationship. Varied horizontal discrepancies of points A and B could give the same ANB measurement because variation in the vertical distance from nasion could compensate for other variation. • Beatty in 1975 reported that ANB angle is not always an accurate method of establishing the actual amount of apical base divergence. www.indiandentalacademy.com
  121. 121. • As an alternative to ANB angle for measuring apical base discrepancy , he devised the AXD angle, where point- x is located by projecting point A on to a perpendicular to SN line. Point D is located in the bony sympyhsis as described by Steiner. The two variables, nasion and point B, were eliminated. He also introduced a linear measurement AD, to describe the A-P relationship of the jaws. www.indiandentalacademy.com
  122. 122. • Cross evaluation with different reference planes is important and can be demonstrated with the ANB angle. • If one takes only the ANB angle to measure the relative position of maxilla and mandible to each other ,one must realize that any different horizontal or vertical position of point N and the location of the points A and B in the vertical plane will have an influence on the size of this angle and not on the actual sagittal relation of the two jaws. (Hussals and Nanda- 1984) www.indiandentalacademy.com
  123. 123. STEINERS ANALYSES Acceptable compromises: • Steiner clearly recognized that cephalometric standards are merely gauges by which to determine more favorable compromises as a treatment goal. He developed a chart that reflects a number of average measurements of normal Dentofacial relationships. • Steiner recognized variations in antero -posterior jaw relations to each other. • The compromise describes the anticipated axial inclinations of the maxillary and mandibular incisors to the NA and NB lines at various ANB relationships. www.indiandentalacademy.com
  124. 124. •The Steiner compromises are geometric resultants of morphogenetic variations and their resulting treatment possibilities. www.indiandentalacademy.com
  125. 125. Method of appraisal of jaw disharmony- Wits • The Wits appraisal is the extent to which the jaws are related to each other. • The occlusal plane is drawn through the region of the overlapping cusps of the first premolars and first molars. • The wits appraisal is done by drawing perpendicular lines from points A and B to the functional occlusal plane. • The distance b/w the points of intersection AO & BO is measured & it is describes the maxillary and mandibular relationships. www.indiandentalacademy.com
  126. 126. • The average jaw relationship according to Wits is – minus 1 mm for men and 0 mm for women. www.indiandentalacademy.com
  127. 127. Shortcomings of Wits appraisal However, the wits appraisal relates point A & B to the functional occlusal plane; this generates 2 major problems. 1) Accurate identification of the occlusal plane is not always easy or accurately reproducible, especially in in mixed dention patients or patients with open bite, sever cant of the occlusal plane, multiple impactions, missing teeth, skeletal asymmetries, or steep curve of spee. 2) Any change in the angulation of the functional occlusal plane, caused by either normal development of the dentition or orthodontic intervention, can profoundly influence the Wits appraisal. www.indiandentalacademy.com
  128. 128. WITS APPRACIAL APPLIED TO CLASS I AND CLASS II SKELETAL JAW BASES www.indiandentalacademy.com
  129. 129. A new approach of assessing sagittal discrepancies; The Beta angle – Chong Baik and Maria Ververidou –AJO-DO;2004 • Because of lot of limitations in assessing A-P jaw relation by various analysis like ANB, wits appraisal. To overcome these limitations they established new cephalometric measurements i.e. Beta angle. •This angle does not depend on any cranial landmarks or dental occlusion. •The Beta angle uses 3 skeletal land marks( 1) A point( 2) B point( 3) the center of the condyle, found by tracing the head of the condyle and approximating its centre (point- C).www.indiandentalacademy.com
  130. 130. • Next it require 3-lines; (1)line connecting the centre of the condyle C with B point ( C-B line). (2) line connecting A and B points .(3) line from point A perpendicular to the C-B line. • Finally, measuring the Beta angle, which is the angle b/w the last perpendicular line and the A-B line. www.indiandentalacademy.com
  131. 131. • It uses 3 points located on the jaws ( 1) A point( 2) B point( 3) the center of the condyle (point- C). • So changes in this angle reflect only changes with in the jaws. In contrast to ANB angle, the configuration of the Beta angle gives it the advantage to remain relatively stable even when the jaws are rotated, for e.g.; when B point is rotated backward & downward, then C-B line is also rotated in the same direction, carrying the perpendicular from point A with in it. Because A- B line is also rotating in a same direction, the Beta angle remains relatively stable. www.indiandentalacademy.com
  132. 132. B e t a a n g l e Fig shows: Beta angle remains relatively stable even when jaws are rotated www.indiandentalacademy.com
  133. 133. • Another advantage of Beta angle is that it can be used in consecutive comparisons throughout orthodontic treatment because it reflects true change of the sagittal relationship of the jaws, which might be due to growth or orthodontic or orthognathic intervention. SHORTCOMING OF BETA ANGLE: 1) Precisely tracing the condyle and locating its center is not always easy. For that reason, some clinicians might hesitate to use the Beta angle. 2) To accurately use this angle, the cephalometric x-rays must be high quality.www.indiandentalacademy.com
  134. 134. •The advantage of locating the center of the head of the condyle versus the condylion point, as used by McNamara, is that very precise tracing of the contour of the condyle is not really necessary. The clinician can visualize and approximate the centre with a minimum error in the Beta angle as long as that point is with in 2 mm of its actual location. www.indiandentalacademy.com
  135. 135. they concluded that: 1) Previously established measurements for assessing the sagittal jaw relationship can often be inaccurate. 2) A new angle, the Beta angle, was developed as a diagnostic aid to evaluate the sagittal jaw relationship more consistently. 3)White subjects with a Beta angle b/w 27 degrees & 35degrees have a class I skeletal pattern; a Beta angle less than 27 degrees indicates a class II skeletal pattern, and a Beta angle greater than 34 degrees indicate a class III skeletal pattern. 4) There is no statistically significant difference b/w mean Beta angle values of males and females. www.indiandentalacademy.com
  136. 136. A-Po line and cephalometric correction- Ricketts • The A-Po line is another method used in cephalometric analyses to assess the position of mandibular incisor tooth. • A range of –2mm to +3mm is considered a satisfactory incisor position, with + 0.5 mm lower incisor tip to A-Po line being an idealized position. • Downs credits Ricketts for suggesting relating the lower incisor to the profile, specifically the lower face using A-Po. www.indiandentalacademy.com
  137. 137. • Cephalometric correction describes a method to determine mandibular dental arch crowding or spacing by assessing mandibular incisor position on a cephalometric radiograph in concert with mesiodistal dimensions of mandibular teeth and mandibular arch circumference. • The rationale is that by advancing or retracting the mandibular incisor 1mm will result in a 2mm gain or a 2 mm reduction in the available space for mandibular arch, respectively. www.indiandentalacademy.com
  138. 138. • Calculations have indicated that tipping the lower incisor tooth forward by 3 degrees results in total dental arch length increase of 2.5mm. • Conversely, retracting the mandibular incisor 3 degrees will encroach on the lower arch length by 2.5mm. • Use of the linear measurement lower incisor to A-Po line alone must be used with caution. This linear measurement does not take into account lower incisor angulation, which emphasizes the risks inherent in using single measurements in cephalometric diagnosis and treatment planning. www.indiandentalacademy.com
  139. 139. In fig (a), (b), and (c), the mandibular incisor tip lies on the A-Po plane. The incisor mandibular plane angle (dotted line to MP) varies from near ideal (a), to obtuse (b), and acute (c). Accepting linear lower incisor position to the A-Po line alone is inadvisable. The profile, as judged by the S-line, is optimal in (a). www.indiandentalacademy.com
  140. 140. •Ricketts stresses the significance of utilizing linear as well as angular measurements in these assessment. • All cephalometric measurements must be evaluated in concert with other measurements and must include clinical and diagnostic judgment. www.indiandentalacademy.com
  141. 141. Mc Namara analyses: • For determining the anteroposterior relationship to maxilla and mandible , mid facial length is measured from condylion to point A. The effective length of the mandible is measured from condylion to gnathion. • Birte Melsen suggests that there are displacements of condyle,pogonion,menton and point B relative to superimposition on implants at a study done on annual intervals between 8.5 yrs and 15.5 yrs of age. www.indiandentalacademy.com
  142. 142. Soft tissue analyses- Holdaway • NASO LABIAL ANGLE – formed by two lines namely the columella tangent and an upper lip tangent. Arbitrary value is 90 to 110 degrees. • Legan and Burstone report a mean value of 102 +/- 4 degrees. www.indiandentalacademy.com
  143. 143. • Scheidman et al drew a postural horizontal line through subnasale and further divided the nasolabial angle into columella tangent to postural horizontal ( 25 degrees) and upper lip tangent to postural horizontal ( 85 degrees). • They argue that each of these angles should be assessed individually in as much as they vary independently. • An apparently normal nasolabial angle may be oriented in an abnormal fashion, a fact that would be disclosed if the component angles were measured individually. www.indiandentalacademy.com
  144. 144. www.indiandentalacademy.com
  145. 145. • E line: (Esthetic plane) Drawn from tip of nose to soft tissue pogonion. Normally the upper lip is about 4 mm behind this reference line while the lower lip lies about 2 mm behind it. • Ricketts admits that considerable variation exists in terms of age and sex. He therefore advises that adult lips should be contained with nose – chin lip line. www.indiandentalacademy.com
  146. 146. E- LINE ( ESTHETIC PLANE) www.indiandentalacademy.com
  147. 147. S line:- Steiner line is a line drawn from soft tissue pogonion to the mid point of the S shaped curve between sub nasale and nasal tip. www.indiandentalacademy.com
  148. 148. H line: The harmony line is tangent to the chin point and the upper lip. The H line angle formed between this line and the soft tissue nasion – pogonion line. The H line angle measures either the degree of upper lip prominence or the amount of retrognathism of the soft tissue chin. www.indiandentalacademy.com
  149. 149. ADVANTAGES AND LIMITATION OF DIGITAL CEPHALOMETRYwww.indiandentalacademy.com
  150. 150. Introduction • Digital radiography has been widely accepted for medicine; however, it was not until the1980s that first intra- oral sensors were developed for use in dentistry. • The introduction of extra- oral digital radiography was initially delayed due to the high cost of extra -oral systems. Recently, the development of cost-effective extra -oral digital technology, coupled with an increased utilization of computers in orthodontic practice, has made direct digital cephalometric imaging valid option. www.indiandentalacademy.com
  151. 151. • As a result, an increasing number of conventional film based radiographic units are being replaced by direct digital machines. Direct digital images can be acquired through the use of photostimulable phosphor plates, or charge coupled device receptors, both of which offer a number of advantages over film. • These advantages include instantaneous image acquisition, reduction of radiation dose, facilitated image enhancement and archiving, elimination of technique sensitive developing process and its associated costs, and facilitated image sharing. www.indiandentalacademy.com
  152. 152. Digital imaging A digital image is a matrix of square pieces, or picture elements (pixels), that form a mosaic pattern from which the original image can be reconstructed for visual display. An analog image, such as a radiographic film, has virtually an infinite number of elements, with each element represented by a continuous gray scale. www.indiandentalacademy.com
  153. 153. • The pixels in a digital image are arranged in a matrix for e.g., a 512 x 512 pixel matrix will contain 262,144 pixels. If large number of pixels are used to represent an image, their discrete nature becomes less apparent, i.e. the spatial resolution of the image improves as the number of pixels increases. • Each pixel has a digital value that represents the intensity of the information recorded by the detector at the point. Each digital value is represented as binary number; information is recorded in terms of a series of ones or zeros. Each one or zero is called a “bit”. In 6-bit image each pixel will have 64 possible values, ranging from 0, which represent a black area on the image, to 63, which represents a white area; an 8-bit image each pixel will have 256 possible values. The quality of an image depends on both the number of pixels and number of gray levels which make up the image.www.indiandentalacademy.com
  154. 154. IMAGE ACQUISITION There are 2 ways to acquire a digital image. 1)Indirect acquisition: A digital image can be produced by scanning conventional radiographs using a flatbed scanner and a transparency adaptor, or by using a charged coupled device camera instead of the flatbed scanner. This image can be manipulated using software packages or be passed on to a second party via a modem. www.indiandentalacademy.com
  155. 155. 2) Direct digital imaging There are two systems available, one produces the image immediately on the monitor post-exposure and is therefore called Direct Imaging. The second has an intermediate phase, whereby the image is produced on the monitor following scanning by laser. This is known as semi-direct imaging. www.indiandentalacademy.com
  156. 156. a) Semi-direct image plate systems • The image plate method involves the use of phosphor storage plate (psp). This plate stores energy after exposure to radiation and emits light when scanned by a laser. The scanner stimulates the phosphor plate and stores a record of the number of light photons detected. • Loading of the scanner generally only requires subdued lighting as the plates are slightly sensitive to visible light. However, some products are more light sensitive than others. The lasers used are centered around the 600-nm band and are usually of the helium- neon variety. • Scanners, the size of a bread- maker, can accommodate multiple image plates at any one time. The exact numbers varies between manufacturers. There is a delay while the image is ‘developed’ before it appears on the monitor. www.indiandentalacademy.com
  157. 157. • Up to eight bitewing radiographs take about 90 secs and a panoramic image can take approximately 3 minutes to be scanned. Again, the scan times do vary between manufacturers. • Although the plate can store energy for a number of days, information starts to be lost within minutes after exposure and it is advised to scan the plates quite quickly to optimize the image recovered. To fully remove the latent image the plate should be exposed to high intensity light. www.indiandentalacademy.com
  158. 158. • Image plates are available in exactly the same sizes as conventional film and come with disposable plastic barriers. They have no wires attached and are reusable for thousands of exposures, but do need careful handling to avoid surface damage. www.indiandentalacademy.com
  159. 159. b) Direct sensor systems • The sensor for the radiation image is usually a Charged Coupled Device [CCD]. It consists of silicon crystals arranged in a lattice and converts light energy into an electrical signal. • This technology is widely used in video cameras. The sensor cannot store information and must be connected via fiber optic wires to the monitor, which can make the sensor bulky and awkward to use. www.indiandentalacademy.com
  160. 160. • The greatest advantage of the direct sensor system is the gain in time. The image is directly projected onto the computer screen. • Originally, the active areas of the sensors were smaller than conventional film, which increased the incidence of ‘coning off’ and required repeat exposures to capture all the desired information. Recent innovations have produced sensors approaching or equal to standard film sizes.www.indiandentalacademy.com
  161. 161. Advantages of digital imaging 1) Image archiving 2) Teleradiology 3) Reduction in radiation exposure to the patient 4) Image enhancement 5) Automated cephalometric analysis 6) Surgical planning 7) Environmentally friendly www.indiandentalacademy.com
  162. 162. 1) Image archiving • The storage of cephalometric radiographs is expensive and requires space and staff-time that, in theory, could be reduced with the archiving of digital images. • In addition, viewing digital images on display monitors could be more convenient for the operator than retrieving the original radiograph. • Archiving cephalometric radiographs would be of particular benefit in studying craniofacial growth or assessing the effect of treatment, where large number of radiographs are analyzed.www.indiandentalacademy.com
  163. 163. Several methods can be used to store digital images, including i) magnetic storage media- it comes in the form of magnetic disks or magnetic tape. ii) Laser or optical disks -have become the most practical method of storing digital images. iii) Optical tape- is a recent development which uses technology similar to that of optical disks and has a high capacity and low cost. www.indiandentalacademy.com
  164. 164. 2) Teleradiology • Teleradiology is the transmission of radiographic images to distant sites. It would provide easy access to radiology facilities in rural or isolated areas and would also permit the transfer of images b/w centers which may improve patient care and aid research. www.indiandentalacademy.com
  165. 165. 3) Reduction in radiation exposure to the patient • High quality radiographs are essential for cephalometry. The aim of high quality radiographs should not compromise the need for minimal radiation exposure to the patient. • Although the radiographic exposure and potential risk is minimal in dentistry, any reduction in radiographic exposure to the patient from cephalometric radiographs would be of obvious benefit. • With digital imaging, it may be possible to reduce patient exposure using recently introduced techniques in image capture or by enhancing digital images.www.indiandentalacademy.com
  166. 166. • The most important technological advance to date in image capture is the introduction of a reusable photostimulable phosphor plate to replace the conventional radiographic film. • A system using this type of plate was first reported by Sonada et al. and has been gradually introduced into clinical situations in the last 10 years. • Using photostimulable phosphorus plates, a digital image is produced directly from the detected x-ray without the intermediate step of producing a conventional radiographic film. • Kogutt et al. showed that an 85 % reduction in radiation dose, the diagnostic quality of images was comparable to conventional radiographs.www.indiandentalacademy.com
  167. 167. 4) Image enhancement • There is potential for improving the diagnostic quality of digital images by enhancing the images using various algorithms. Digital images can be enhanced using algorithms that mathematically manipulate the gray-level values of the pixels • Using enhancement algorithms it may be possible to extract information from radiographs that previously required further additional radiographic exposure to the patient. • However image enhancement is actually the suppression of information that the operator deems unnecessary for a particular task, rather than the addition of further information.www.indiandentalacademy.com
  168. 168. • Images that are of poor quality due to factors such as incorrect exposure or blurring could be manipulated and reformatted thereby avoiding further exposure. • So it may be possible to use a faster film/screen combination, reducing radiation exposure to the patient, then enhance the images without compromising diagnostic quality. www.indiandentalacademy.com
  169. 169. 5) Automated cephalometric analysis • With the introduction of digital imaging, automated and semi-automated landmark identification directly from the digital image has been investigated. • This would avoid the need for manual tracing of cephalometric radiographs and remove operator subjectivity. • With regard to cephalometric analysis, several systems have shown varying degrees of success in identifying different landmarks. • The system developed by Parthasarathy et al. demonstrated a success rate of 83% in identifying nine cephalometric landmarks on five cephalometric images.www.indiandentalacademy.com
  170. 170. Landmark identification on digital cephalometric radiograph: • When carrying out landmark identification on a digital image of a cephalometric radiograph, identified landmarks can be shown on the displayed image. • Corresponding angular and linear measure- ments can also be displayed and then stored with the image. • This enables the operator to edit landmarks that may have been incorrectly placed. It also permits the operator to review identified landmarks at a later date and again edit their positions. www.indiandentalacademy.com
  171. 171. 6) Surgical planning: • With displayed digital images, cut-and-paste facilities can be used to move areas of either a photograph or a cephalometric radiograph which has been captured as a digital image. • A system outlined by Sarver et al. produced profiles on pre -surgical photographs of the expected result after orthognathic surgery. • The system was able to move soft tissue, with the planned hard tissue movement, and to simultaneously superimpose the cephalometric radiograph on the photograph. www.indiandentalacademy.com
  172. 172. 7) Environmentally friendly: • No processing chemicals are used or disposed of. Both CCD sensors and the PSP plates are capable of being reused for many thousands of exposures. • They can, however, become scratched and damaged if not handled carefully. www.indiandentalacademy.com
  173. 173. LIMITATIONS OF DIGITAL CEPHALOMETRY www.indiandentalacademy.com
  174. 174. • Digital imaging to truly offer significant advantages in cephalo- metry, the image must yield as much information as is currently available on radiographic films. • The properties of conventional film radiography are difficult to match for high spatial resolution, wide dynamic range. www.indiandentalacademy.com
  175. 175. • The quality of digital image is strongly dependent on the spatial resolution, the relationship of the gray level values of the pixels to the optical density of the radiograph and image display. • The number of pixels and gray levels that are required to produce an image of acceptable quality will vary depending on the image itself. Image which contain a large amount of detail depend more on the number of pixels rather than number of gray levels. www.indiandentalacademy.com
  176. 176. Spatial resolution • Spatial resolution is the ability to record separate images of small objects that are placed closely together ; it is measured in line pairs per mm (lp/mm). The smaller the pixel size, the more detail in the image and therefore the greater the resolution. The smallest detail detectable by human eye is 0.1 by 0.1mm. • To provide digital images of radiographs with at least as much information as is available in the original conventional radiograph, pixels no larger than 0.1mm are required, giving a spatial resolution of 5 line-pairs per mm (lp/mm) www.indiandentalacademy.com
  177. 177. • Several studies have been carried out to assess the spatial resolution required for different clinical applications. • Spatial resolution of 8 lp/mm is necessary for skeletal images , for chest and GIT images a spatial resolution of 4 lp/mm is adequate. For musculoskeletal radiography is 10-12 lp/mm. is required. www.indiandentalacademy.com
  178. 178. Optical density • Film blackness is measured by optical density, which is calculated from the logarithm of the ratio: light incident to light transmitted by a film. The quality of digital images is related to the number of gray levels. • Fraser et al. suggested that a 12- bit(4,096 gray levels) images is required to adequately reproduce the wide dynamic range present on the radiograph. www.indiandentalacademy.com
  179. 179. Image display • With improving technology ,the limitations of pixel size and the number of gray levels can be overcome and the limiting factor in the quality of digital images will be the spatial resolution of the display monitor, which can be dictated by the number of raster lines. • Monitors displaying up to 625 lines are routinely used for viewing of digital images. Where image quality is particularly important, a 2,048 – line monitor should be used to give comparable resolution to a radiographic film.www.indiandentalacademy.com
  180. 180. Forsyth D.B et al. (AO-1996;66;43-50) studied to compare conventional cephalometric radiographs with their digital counterparts with regard to the validity and reproducibility of angular and linear measurements. They concluded that: 1) Calibration of the digital image produces a small but significant error. 2) The spatial resolution of the digital image is less than that of the conventional radiograph. 3) The digital image is unable to match the conventional radiograph in dynamic range and sensitivity to small changes in optical density. www.indiandentalacademy.com
  181. 181. 4) The random error associated with angular/linear measurements and landmark identification tend to be greater with the digital images than the conventional radiographs. 5) With the majority of angular and linear measurements there is a systematic error b/w the digital images and the conventional radiographs. Landmarks on poorly defined edges such as nasion and point A appear to have the greater error. www.indiandentalacademy.com
  182. 182. MEDICOLEGAL • Concerns have been raised in the past about the ability to manipulate the images for fraudulent purposes. Manufacturers of software programmers have installed ‘audit trails’ which can track down and recover the original image. www.indiandentalacademy.com
  183. 183. Conclusion • Although innumerable limitations exist in the field of cephalometrics. This is not to suggest that cephalometry is not a useful measurement tool for use by clinical orthodontist, it is still a very significant & effective diagnostic tool. • A combination of various cephalometric norms and variables should be compiled to arrive at a proper diagnosis. www.indiandentalacademy.com
  184. 184. • The technology is now available to run a practice almost paper free. It is theoretically possible to store clinical notes, photographs, radiographs, & study models on disc, refer or consult on line. The future of digital imaging could include the testing & upgrade of X-ray equipments & software online. • Research is also continuing in to the development of a credit card sized ‘smart card’, which could carry a patient’s medical & dental notes along with their radiographic images. • It is important that advances in technology are accepted & the benefits that they produce utilized in order that clinical practice & patient care continue to improve.www.indiandentalacademy.com
  185. 185. BIBILOGRAPHY 1) Text book of Radiographic Cephalometry by Alexander Jacobson. 2) Text book of Orthodontic current principals & tech; 4th edn, by T.M.Graber & Robert .L. Vanarsadall. 3) Baumrind et al- The reliability of head film measurement 1.landmark identification –AJO;1971;60;2 4) Steiner.C; Cephalometrics for you & me;AJO-1953,39;10 5) Salzmann.J.A ; Limitations of roentgenographic ceph’s; AJO;1964;50;3 6) Miller.A – Analysis of errors in ceph measurement of 3- dimensional distance of the maxilla- Ang Ortho-1966;36;2 www.indiandentalacademy.com
  186. 186. 7) Richardson .A ; An investigation in to the reproducibility of some points, planes & lines used in ceph analysis – AJO;1966;52;9 8) Ahlqvist et al; The effect of projection errors on cephalometric length measurements-EJO;1986;8;141-148 9) Midtgard. J- et al; Reproducibility of cephalometric landmark errors of measurements of cephalometric cranial distances- Ang Ortho;1974;44;56-61 10) McWilliam.J. et al –The effect of image quality on the identification of ceph landmarks –Ang. Ortho-1978;48;1 11) Jacobson R.;Point A revisited;AJO-DO; 1980;JAN;94-96 12) Tremont T.J. ;An investigation of the variability b/w the optic plane & frank fort horizontal –AJO-DO ; 1980;Aug;192-200 www.indiandentalacademy.com
  187. 187. 13) Houston W.J.- the analysis of errors in orthodontic measurements- AJO;1983;83;5 14) Hussels.W & Ram Nanda- Analysis of factors affecting angle ANB –AJO-DO;1984;MAY;411-423 15) Lundstrom A et al- The frankfort horizontal as a basis for cephalometric analysis-AJO-DO;1995;May;537-540 16)Trpkova B. et al-Cephalometric landmarks identification & reproducibility ;A meta analysis –AJO-DO ;1997;112;165-70 17) Major. P et al- landmark identification error in P-A ceph -Ang.Ortho ;1994;64;6 18) Baik & Ververidou – A new approach of assessing sagittal discrepancies : The Beta angle- AJO-DO;2004;126;100-5www.indiandentalacademy.com
  188. 188. 19) Handbook of Orthodontics- 4th edn; by Robert E Moyers. 20) Forsyth.D.B et al.– digital imaging of cephalometric radiography. Part 1: advantages and limitations of digital imaging -AO-1996;66;1 21) Forsyth.D.B et al- digital imaging of cephalometric radiography-part 2: image quality- AO-1996;66;1 22) Brennan.J –An introduction to digital radiography in dentistry- Jurnl of Ortho- 2002;29;66-69 www.indiandentalacademy.com
  189. 189. THANKYOU www.indiandentalacademy.com

×