Successfully reported this slideshow.
We use your LinkedIn profile and activity data to personalize ads and to show you more relevant ads. You can change your ad preferences anytime.

Finishing with lingual appliances /certified fixed orthodontic courses by Indian dental academy

1,238 views

Published on

The Indian Dental Academy is the Leader in continuing dental education , training dentists in all aspects of dentistry and offering a wide range of dental certified courses in different formats.

  • Be the first to comment

Finishing with lingual appliances /certified fixed orthodontic courses by Indian dental academy

  1. 1. FINISHING WITH LINGUAL APPLIANCES www.indiandentalacademy.com
  2. 2. INDIAN DENTAL ACADEMY Leader in continuing dental education www.indiandentalacademy.com www.indiandentalacademy.com
  3. 3.  When treating a malocclusion with the lingual appliance, the finishing phase is probably the most challenging and difficult stage of treatment.  A major advantage of the lingual appliance over the labial appliance at this stage of treatment is the absence of brackets, wires, and sometimes gingival hypertrophy masking the labial surfaces and possibly misleading clinical judgment. www.indiandentalacademy.com
  4. 4.  The difficulties encountered at the finishing phase of lingual orthodontics derive from the following three main sources:  1. Patients’ characteristics  2. Anatomy of the lingual surfaces  3. Mechanics of lingual treatment www.indiandentalacademy.com
  5. 5. Patients’ Characteristics  Most of the patient receiving lingual orthodontics are adults with specific personal requirements often associated with general dental and periodontal problem.  Treatment is more demanding and requires an interdisciplinary approach with other dental disciplines to achieve optimum final results. www.indiandentalacademy.com
  6. 6.  Restored teeth- full crown/lingual restoration – – – Change in buccolingual thickness of tooth Compensatory change in bracket base Compensatory bends in initial wire www.indiandentalacademy.com
  7. 7. Abraded teeth    Vertical finishing is complicated by short occlusogingival dimension and complexity of lingual contour Compensations for passive eruption Extrusion/intrusion- Progressive 3D wire bending is required www.indiandentalacademy.com
  8. 8. (A) Step-up bend to intrude an incisor (a) will move the crown labially as well. To avoid the labial crown movement, the step-up should have an inset component(b). (B) Offset bend for labial movement (c) will move the crown gingivally as well. To avoid the upward crown movement, the offset bend should have a downward component (d) www.indiandentalacademy.com
  9. 9. Anatomy of the Lingual Surfaces   Modifications of the bracket base should compensate for lingual anatomy including built in tip, torque and in/out variation. Accurate rebonding without alteration in original bracket base www.indiandentalacademy.com
  10. 10. Mechanical Difficulties Point of force application Some distance from labial surface which defines final alignment Some distance from center of resistance Hence finishing bends should be placed in more than one planes of space www.indiandentalacademy.com
  11. 11. Short lingual arch length Small interbracket distance Poor expression of prescription Appliance should be left in position for longer time with lower levels of force to prevent over powering of appliance and archwire bowing www.indiandentalacademy.com
  12. 12. Side Effects Specific To Lingual Technique      Upright incisors Mesially tipped molars Lateral open bite (vertical bowing) Arch expansion Distolingual molar rotation (transverse bowing) www.indiandentalacademy.com
  13. 13. Prevention of Finishing Problems  Correct patient selection  Laboratory procedure – Accurate bracket base construction – Adequate bonding procedure- ↓ bracket failure  Treatment mechanics (light forces) – Avoid anchorage loss – Avoid bowing effects – Avoid torque loss www.indiandentalacademy.com
  14. 14. Minimize Wire Bending During Main Treatment Phases    Correct bracket positioning Full engagement of archwire Complete prescription expression – Vertical discrepancy may be due to incomplete torque expression not bracket height www.indiandentalacademy.com
  15. 15. Rotational Correction  Difficult due to – – – – Small arch perimeter Reduced interbracket distance Lack of space for overcorrection of bracket positioning Less effective rotational bends www.indiandentalacademy.com
  16. 16. Mechanism of Rotation Correction    Full engagement of archwire Reciprocal rotation One by one rotation – Bond the most severely rotated tooth first  Rotation off an anchorage unit – Figure of 8 tie on multiple teeth to form anchorage unit www.indiandentalacademy.com
  17. 17. Mechanism of Rotation Correction  Rotation of a crimpable hook – E- chain from bracket to hook crimped on archwire  Anti- rotation elastics – Clear E- chain from bracket through contact point along labial surface of rotated tooth and adjacent tooth doubled back to hook on adjacent tooth  Rotation tie – E- chain threaded on archwire before insertion  Half rotation tie – Clear labial button is used www.indiandentalacademy.com
  18. 18. Systematic Finishing Procedure O B S E R V A T I O N General Facial & Dental Esthetics Specific Tooth Positions www.indiandentalacademy.com
  19. 19. Step I of Finishing Protocol     Eliminate problems that derive from wire disengagement Allow expression of bracket prescription by using resilient archwire Incisor torque expression, minor rotation correction, expansion Vertical bowing effect correction www.indiandentalacademy.com
  20. 20. Step I of Finishing Protocol (Mechanics)    Should be carried out for 3-4 months 17x17 Cu NiTi for 0.018 slot Figure of 8 ligation across extraction spaces www.indiandentalacademy.com
  21. 21. Step II of Finishing Protocol     Settling of occlusion Correction of minor midline discrepancy Correction of minor anteroposterior & vertical discrepancy Mechanics – – – – Lower stabilizing arch, 17X17 TMA or SS Upper 0.014 round sectional SS canine to canine Figure of 8 ligature Vertical elastics www.indiandentalacademy.com
  22. 22. Vertical Elastics        Labial composite buttons are bonded Anterior labial to labial – Class I & Class II cases Anterior lingual to lingual – Open bite Anterior upper lingual to lower labial - Class III Anterior cross elastics – Center line discrepancy Posterior vertical elastics Period of wear 4-6 weeks www.indiandentalacademy.com
  23. 23. Step III of Finishing Protocol     Final detailing and finishing bends Preferred over bracket repositioning Done in pt time or on model Mechanics – Upper 17x17 TMA – Lower 0.016 TMA  Bends are 1st placed in the maxillary archwire www.indiandentalacademy.com
  24. 24. Different Bends Used for Detailing •Inset Bend •Should be wide to avoid adjacent bracket interference •Accompanied by step up to avoid elongation of crown www.indiandentalacademy.com
  25. 25. Different Bends Used for Detailing •Offset Bend •Should be narrow to allow full engagement •Accompanied by step down to avoid crown shortening www.indiandentalacademy.com
  26. 26. Different Bends Used for Detailing    Rotation bend Should be tied with steel ligature Lingual component should be away from bracket www.indiandentalacademy.com
  27. 27. Tooth Positioner   Suggested for final finishing Risk of reopening extraction space and loss of final detailing www.indiandentalacademy.com
  28. 28. Postfinishing Finalizing Procedures  After appliance removal– Occlusal contacts should be checked using articulating paper – Esthetic recontouring of incisal edges – Bleaching of incisor edges www.indiandentalacademy.com
  29. 29. Thank you www.indiandentalacademy.com Leader in continuing dental education www.indiandentalacademy.com

×