Successfully reported this slideshow.
We use your LinkedIn profile and activity data to personalize ads and to show you more relevant ads. You can change your ad preferences anytime.
Mª Rocío Rodríguez Barroso
Department of Environmental
Technologies
University of Cadiz
Integral water Cycle
SUPPLY
SANITATION
TREATMENT
REUSE
ÍNDEX
3
Urban Water Cycle: SUPPLY
Regulation
Deposits
SWT
acuífer
surface
STATION WATER TREATMENT:
DRINKING WATER
LEGISLATION SU...
SYPPLIES: springs and wetlands fed by rivers and
groundwater
SWT: STATION WATER TREATMENT
5
Urban Water Cycle : SANITATION
Regulation
Deposits
WTP
EDAR
(spanish)
SWT
ETAP
(spanish)
acuifer
surficial
Reuse
WASTEWA...
SANITATION: SEWAGE/ DISPOSAL
EDAR-RANILLA EDAR-COPERO
 TREATMENT: What is a WTP- Water treatment plant?
It is an installing that collects wastewater from a population or indus...
Influent-wastewater EDAR
Effluent-
Treated
water
1.
Sludge-(mud)2.
1.
2.
Reuse??
Agricultural application ??
SUPPLY / TREATMENT
SANITATION / TREATMENT
REUSE
2. INTEGRATED WATER CYCLE IN GUADALETE RIVER
STUDY ZONE
2.- INTEGRATED WATER CYCLE IN GUADALETE RIVER
SUPPLY
POPULATION
UPPER COURSE: 62 558 inhabitant
Guadalete River...
Stadium Santiago Bernabeu (1 Hm3 )
Olympic pool (1500 m3 )
How much water have we got?
TOTAL: 333 709 inhabit
Endowment: 1...
12
2.- INTEGRATED WATER CYCLE IN GUADALETE RIVER
SUPPLY
Guadalete basin
13
2.- INTEGRATED WATER CYCLE IN GUADALETE RIVER
SUPPLY
Station Water
Treatmemt
2 RESERVOIRS: MAJACEITE RIVER
Guadalcacín: 800hm3; presa
materiales sueltos; aliviadero de
lamina libre y 4 tomas de agua
...
15
SSS
STATION WATER TREATMENT:
DRINKING WATER - El Montañés
Capacidad: 2500 l/seg, hasta 5000 l/seg
4 decandadores 28 m ...
SUPPLY / TREATMENT
SANITATION / TREATMENT
REUSE
2. INTEGRATED WATER CYCLE IN GUADALETE RIVER
17
STP
SWT
acuíferos
superficial
2.- INTEGRATED WATER CYCLE IN GUADALETE RIVER
REGULATIONS
WASTEWATER TREATMENT RULES:
DIR...
DIRECTIVE (European Union) 91/271/CEE: Artícle 2
E.h. (equivalent inhabitant): following the EU criteria by which an equiv...
Cuadro 1. Requisitos para los vertidos procedentes de instalaciones de tratamiento de aguas residuales
urbanas sujetos a l...
Cuadro 2. Requisitos para los vertidos procedentes de instalaciones de tratamiento de aguas
residuales urbanas realizados ...
DQO (mg/l O2)
DBO5 (mg/l O2)
Sólidos Suspensión (mg/l)
Fósforo total (mg/l)
Nitrógeno total (mg/l)
DQO < 125 mg/l O2 (75 %...
Questions…..?
1. How many Water Treatment Plants are in Guadalete basin?
2. Are they according with the rules (Directive E...
Activated Sludge
FANGOS ACTIVADOS
Villages: Ubrique
Bacterial beds
LECHOS BACTERIANOS
Olvera N y S
Algodonales
El Gastor
Z...
Activated Sludge
FANGOS ACTIVADOS
Jerez (little town)
Arcos
Bacterial beds
LECHOS BACTERIANOS
Villamartín
Paterna de la Ri...
PROYECT 1: Wastewater study of WTP from Guadalete Basin (2002-2004)
according to the normative?
Río Guadalete Río Majaceit...
Tecnología Población hab-eq
% de Reducción Cumplimiento
RD 509/1996DBO5 DQO SS Ntotal Ptotal
Fangos activados Ubrique (PN)...
TECNOLOGÍA Población H-E
% de Reducción Cumplimiento
RD 509/1996DBO5 DQO SS Ntotal Ptotal
Fangos activados Jerez 272.162 9...
Código Punto de
muestreo
Habitantes Porc
%
Hab-
equiv
Código Punto de
muestreo
Habitantes Porc
%
Hab-
equiv
CUENCA ALTA CU...
Compared study between both basins
HABITANTES
(2005)
VERTIDOS HAB– EQUIV Ratio
(h-e)/hm3/año litros/día % Cuenca h-e % Cue...
Anual load generated by the urban (before the WTP)
Carga DBO5 = 5 960 Tm/año de O2. 50,45 % del total
Carga DQO = 9 191 Tm...
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
DBO DQO SS
%CARGAANUAL
PARÁMETROS CONTROLADOS
CARGA ANUAL DE VERTIDOS AL GUADA...
POPULATIONS Discharges
m3/ año
Anual load dicharges
(Tm/year)
DBO
Tm/año O2
DQO
Tm/año O2
SS
Tm/año
CURRENTLY: Without tre...
3. Is the quality of the water in the river in good condition?
Second project
Código Punto de muestreo
UPPER COURSE
Majaceite River
Ubrique-1
Upstream from
WTP
Ubrique-2
Downstream from
WTP
Bosque-1
U...
Muestras
DBO5
mg/l O2
DQO
mg/l O2
SS
mg/l
Ubrique-1 7 13 11
Ubrique-2 14 32 21
El Bosque-1 8 25 15
El Bosque-2 7 23 25
Arc...
River pollution indices: WQI- Water Quality Index
(Pesce &
Wunderlin, 2000)
Ci
Parám. Pi 100 90 80 70 60 50 40 30 20 10 0
...
River pollution indices: clasification
Punto de
muestreo
WQI CALIFICACIÓN
Ubrique-1 61 MEDIUM
Ubrique-2 52 MEDIUM
El Bosqu...
Questions…..?
1. How many Wastewater Treatment Plants are in the
Guadalete basin?
2. Are according with the law (Directive...
46 % of population without treatment
Report on the situation of waste water treatment in the
Province of Cádiz
2.2.3.1. VILLAGES WITHOUT SWT
Benaocaz. Vertido ...
Report on the situation of waste water treatment in the
Province of Cádiz
46 % de la población de la provincia de Cádiz no...
2.2 Informe sobre la situación de la depuración
de las aguas residuales en la Provincia de Cádiz.
2.2.4. WATER BILL. A qui...
CONCLUSIONS
1. How many Wastewater Treatment Plants are in the
Guadalete basin?
There are sufficient WTP but their operati...
Thanks for your attention
Lecture 4  rocio rodriguez
Lecture 4  rocio rodriguez
Upcoming SlideShare
Loading in …5
×

Lecture 4 rocio rodriguez

610 views

Published on

Published in: Education
  • Be the first to comment

  • Be the first to like this

Lecture 4 rocio rodriguez

  1. 1. Mª Rocío Rodríguez Barroso Department of Environmental Technologies University of Cadiz
  2. 2. Integral water Cycle SUPPLY SANITATION TREATMENT REUSE ÍNDEX
  3. 3. 3 Urban Water Cycle: SUPPLY Regulation Deposits SWT acuífer surface STATION WATER TREATMENT: DRINKING WATER LEGISLATION SUPPLING WATER: -Real Decreto 927/1988, State Regulation of drinking water production -Real Decreto 140/2003 of water for human consumption
  4. 4. SYPPLIES: springs and wetlands fed by rivers and groundwater SWT: STATION WATER TREATMENT
  5. 5. 5 Urban Water Cycle : SANITATION Regulation Deposits WTP EDAR (spanish) SWT ETAP (spanish) acuifer surficial Reuse WASTEWATER TREATMENT PLANT: WasteWATER STATION WATER TREATMENT: Drinking water
  6. 6. SANITATION: SEWAGE/ DISPOSAL EDAR-RANILLA EDAR-COPERO
  7. 7.  TREATMENT: What is a WTP- Water treatment plant? It is an installing that collects wastewater from a population or industry, and after a series of treatments and processes, are cleaned and returns to a receiving stream (river, reservoir or sea).
  8. 8. Influent-wastewater EDAR Effluent- Treated water 1. Sludge-(mud)2. 1. 2. Reuse?? Agricultural application ??
  9. 9. SUPPLY / TREATMENT SANITATION / TREATMENT REUSE 2. INTEGRATED WATER CYCLE IN GUADALETE RIVER
  10. 10. STUDY ZONE 2.- INTEGRATED WATER CYCLE IN GUADALETE RIVER SUPPLY POPULATION UPPER COURSE: 62 558 inhabitant Guadalete River: 11 villages Majaciete River: 5 villages LOWER COURSE: 261 121 inhabitant Guadalete River: 15 villages TOTAL: 333 709 inhabitant
  11. 11. Stadium Santiago Bernabeu (1 Hm3 ) Olympic pool (1500 m3 ) How much water have we got? TOTAL: 333 709 inhabit Endowment: 120 l/inh day 40 045 m3/day = 14,6 Hm3/year Guadalete River 3 reservoirs (437 Hm3) Majaceite River 2 reservoirs (935 Hm3) •Zahara-El Gastor: 223 Hm3 •Bornos: 200 Hm3 •Arcos: 14 Hm3 •Guadalcacín: 800 Hm3 •Los Hurones: 135 Hm3 2.- INTEGRATED WATER CYCLE IN GUADALETE RIVER SUPPLY How much water need the population?
  12. 12. 12 2.- INTEGRATED WATER CYCLE IN GUADALETE RIVER SUPPLY Guadalete basin
  13. 13. 13 2.- INTEGRATED WATER CYCLE IN GUADALETE RIVER SUPPLY Station Water Treatmemt
  14. 14. 2 RESERVOIRS: MAJACEITE RIVER Guadalcacín: 800hm3; presa materiales sueltos; aliviadero de lamina libre y 4 tomas de agua Los Hurones: 135hm3; presa de gravedad; aliviadero en vertedero y 3 tomas de agua 2.- INTEGRATED WATER CYCLE IN GUADALETE RIVER SUPPLY
  15. 15. 15 SSS STATION WATER TREATMENT: DRINKING WATER - El Montañés Capacidad: 2500 l/seg, hasta 5000 l/seg 4 decandadores 28 m  12 filtros de 14.60 m x 9,46 m TECNOLOGÍAS: Precloración- decantación-filtración-desinfección con cloro 5 depósitos de almacenamiento semienterrados: 200.000 m3 h: 6 m 2.- INTEGRATED WATER CYCLE IN GUADALETE RIVER SUPPLY
  16. 16. SUPPLY / TREATMENT SANITATION / TREATMENT REUSE 2. INTEGRATED WATER CYCLE IN GUADALETE RIVER
  17. 17. 17 STP SWT acuíferos superficial 2.- INTEGRATED WATER CYCLE IN GUADALETE RIVER REGULATIONS WASTEWATER TREATMENT RULES: DIRECTIVE (European Union) 91/271/CEE TRANSPOSITION - Real Decreto-Ley 11/1995 - Real Decreto 509/1996 -REUSE WASTEWATER: -REAL DECRETO 1620/2007, de 7 de diciembre, por el que se establece el régimen jurídico de la reutilización de las aguas depuradas
  18. 18. DIRECTIVE (European Union) 91/271/CEE: Artícle 2 E.h. (equivalent inhabitant): following the EU criteria by which an equivalent inhabitant produces 60 grams of BOD5 per day, caused by domestic activities. Related with presence of ORGANIC MATTER in wastewater Analysis: BOD: Biochemical Oxygen Demand (mg/l O2) QOD: Chemical Oxyen Demand (mg/l O2) TOC: Total Organic Carbon (mg/l) Pollution Load (g/day) = Concentration (BOD mg/l O2) x Caudal (m3/day) E-h = Pollution Load / 60 g Example: Jerez DBO5 (mg O2/l ): :400 E-h: 272.162 Current Poblation: 210.000 inhab
  19. 19. Cuadro 1. Requisitos para los vertidos procedentes de instalaciones de tratamiento de aguas residuales urbanas sujetos a lo dispuesto en los artículos 4 y 5 de la presente Directiva. Se aplicará el valor de concentración o el porcentaje de reducción. Parámetros Concentración Porcentaje mínimo de reducción Método de medida de referencia Demanda bioquímica de oxígeno (DBO5 a 20 ºC) sin nitrificación 25 mg/L O2 70 – 90 40 de conformidad con el apartado 2 del Art. 4 Muestra homogeneizada, sin filtrar ni decantar. Determinación del oxígeno disuelto antes y después de 5 días de incubación a 20 ºC 1 ºC, en completa oscuridad. Aplicación de inhibidor de la nitrificaciónl Demanda química de oxígeno (DQO) 125 mg/L O2 75 Muestra homogeneizada, sin filtrar ni decantar. Dicromato potásico Total de sólidos en suspensión 35 mg/L 35 de conformidad con el apartado 2 del Art. 4 (más de 10.000 h-e) 50 de conformidad con el apartado 2 del Art. 4 (de 2.000 a 10.000 h-e) 90 50 de conformidad con el apartado 2 del Art, 4 (más de 10.000 h-e) Filtración de una muestra representativa a través de una memebrana de filtrante de 0,45 micaras. Secado a 105 ºC y pesaje. Centrifugación de una muestra representativa (durante 5 minutos como mínimo, con una aceleración media de 2.800 a 3.200 g), secado a 105 ºC y pesaje. DIRECTIVE (European Union) 91/271/CEE: chart 1
  20. 20. Cuadro 2. Requisitos para los vertidos procedentes de instalaciones de tratamiento de aguas residuales urbanas realizados en zonas sensibles propensas a eutrofización. Según la situación local, se podrá aplicar uno o los dos parámetros. Se aplicará el valor de concentración o el porcentaje de reducción. Parámetros Concentración Porcentaje mínimo de reducción Método de medida de referencia Fósforo total 2 mg/L P (de 10.000 a 100.000 h-e) 1 mg/L P (más de 100.000 h-e) 80 Espectrofotometría de absorción molecular Nitrógeno total 15 mg/L N (de 10.000 a 100.000 h-e) 10 mg/L N (más de 100.000 h-e) 70 - 80 Espectrofotometría de absorción molecular DIRECTIVE (European Union) 91/271/CEE: chart 2
  21. 21. DQO (mg/l O2) DBO5 (mg/l O2) Sólidos Suspensión (mg/l) Fósforo total (mg/l) Nitrógeno total (mg/l) DQO < 125 mg/l O2 (75 %) DBO5 < 25 mg/l O2 (70 - 90 %) Sólidos Suspensión < 35 mg/l (90 %) Fósforo total < 2 mg/l (80 %) Nitrógeno total < 15 mg/l (70-80 %) EXAMPLE DQO (mg/l O2): 800 DBO5 (mg/l O2): 400 Sólidos Suspensión (mg/l): 380 Fósforo total (mg/l): 15 Nitrógeno total (mg/l): 65 DQO < 125 mg/l O2 (75 % → 200 mg/l) DBO5 < 25 mg/l O2 (85 % → 60 mg/l) Sólidos Suspensión < 35 mg/l (90% → 38 mg/l) Fósforo total < 2 mg/l (80% → 3 mg/l) Nitrógeno total < 15 mg/l (75% → 16.3 mg/l) Untreated: INLET Treated: OUTLET
  22. 22. Questions…..? 1. How many Water Treatment Plants are in Guadalete basin? 2. Are they according with the rules (Directive European Union) 3. Is the quality of the water in the river in good condition? Let´s see
  23. 23. Activated Sludge FANGOS ACTIVADOS Villages: Ubrique Bacterial beds LECHOS BACTERIANOS Olvera N y S Algodonales El Gastor Zahara de la Sierra Puerto Serrano Álcalá del Valle Peat beds LECHOS DE TURBA Setenil de las Budegas Torrealháquime Grazalema El Bosque Villaluenga Biodisc BIODISCOS Benamahoma UPPER COURSE: 13 WTP (villages)- 3 villages without WTP Population: 62 558 inhabitant – and E-h: 83 546 E-h 1. How many Water Treatment Plant are in the Guadalete basin? Water Treatment Technologies
  24. 24. Activated Sludge FANGOS ACTIVADOS Jerez (little town) Arcos Bacterial beds LECHOS BACTERIANOS Villamartín Paterna de la Rivera Espera Biodisc BIODISCOS La Barca El Torno Nueva Jarilla Torrecera Reactors underground REACTORES SUBTERRÁNEOS La Ina, S. Isidro Majarromaque, Lomopardo Water Treatment Technologies LOWER COURSE: 13 villages- 5 villages without WTP Population: 261 121 inhabitant – and E-h: 455 000 E-h
  25. 25. PROYECT 1: Wastewater study of WTP from Guadalete Basin (2002-2004) according to the normative? Río Guadalete Río Majaceite Código Población Código Población UPPER COURSE: 62. 558 inhabitant U-10 Setenil U-27 Benamahoma U-08 Alcalá del Valle U-12 El Bosque U-24 Torrealháquime U-43 Benaocaz (V) U-04 Olvera U-03 Ubrique U-11 Grazalema U-21 Villaluenga del R. U-15 Zahara de la Sierra U-13 El Gastor U-06 Algodonales U-07 Puerto Serrano U-31 Villamartín U-40 Prado del Rey LOWER COURSE: 261. 121 inhabitant U-33 Bornos (V) U-02 Arcos de la Frontera U-38 Espera U-25 Majarromaque (Jer. U-09 La Barca (Jerez) U-18 Torrecera (Jerez) U-37 Paterna U-16 El Torno (Jerez) U-22 S. Isidro (Jerez) U-20 La In a (Jerez) U-29 Lomopardo (Jerez) U-17 Nueva Jarilla (Jerez) U-01 Jerez de la Frontera U-42 Algar (V) U-39 S. José del Valle (V) (V = Vertido) (Los Códigos son los empleados por Comisaría de Aguas de Sevilla) Physico-chemical Analysis Temperature Total Nitrógeno (Nt) pH Total Phospforo (Pt) Oxygen (%) Conductivity (CE) BOD5 QO D Biodegradabity (CB) 2.- INTEGRATED WATER CYCLE IN GUADALETE RIVER WASTEWATER 2. Are they according with the normative (Directive European Union)
  26. 26. Tecnología Población hab-eq % de Reducción Cumplimiento RD 509/1996DBO5 DQO SS Ntotal Ptotal Fangos activados Ubrique (PN) 12.032 67,8 57,1 40,3 20,6 48,8 NO Lechos bacterianos Olvera N 9.349 88,4 83,2 92,1 29,5 42,6 SI Olvera S 9.349 44,7 68,0 67,1 21,3 40,2 NO Algodonales 7.584 83,8 77,3 77,8 0,0 27,6 SI El Gastor 3.614 86,3 99,7 87,5 39,7 59,1 SI Zahara (PN) 2.577 87,2 83,3 86,6 28,7 21,9 NO Lagunaje El Bosque (PN) 1.257 21,3 24,6 0,0 56,6 41,7 NO Alcalá del V 2.602 2,9 0,0 31,8 46,3 41,9 NO Filtros de turba Setenil 2.491 57,4 50,7 57,2 7,5 52,8 NO Torrealháq 930 58,3 37,6 24,3 21,1 23,5 NO Grazalema (PN) 3.149 76,7 72,4 75,1 3,7 0,0 NO Villaluenga (PN) 1.487 85,9 73,0 30,0 46,5 61,3 NO Biodiscos Benamahom (PN) 763 51,4 39,9 46,2 11,8 72 NO Límites RD 509/1996 70-90 75 70-90 80 70-80 (PN) Poblaciones del Parque Natural de la Sierra de Grazalema que vierten en zonas sensibles PROYECT 1: upper course 2.- INTEGRATED WATER CYCLE IN GUADALETE RIVER WASTEWATER
  27. 27. TECNOLOGÍA Población H-E % de Reducción Cumplimiento RD 509/1996DBO5 DQO SS Ntotal Ptotal Fangos activados Jerez 272.162 94´6 88´1 92´5 69´2 85´8 SI Arcos 92.183 90´8 92´8 95´3 57´6 46´0 SI Lechos bacterianos Villamartín 35.920 93´7 88´8 68´8 63’9 72´7 NO Paterna 8.986 50´0 49´1 55´9 37´9 0 NO Biodiscos La Barca 11.077 92´8 90´0 96´1 73´4 75´9 SÍ Nueva Jarilla 1.201 67´3 65´3 74´1 50´7 28´8 NO Torrecera 4.452 91´7 90´6 97´0 56´4 69´4 SI La Ina 155 0´0 0´0 0´0 0´0 0´0 NO S. Isidro 159 18´3 19´6 0´0 21´8 6´1 NO Majarromaque 451 36´2 6´3 0´0 24´4 33´3 NO Lomopardo 1.117 0´0 0´0 54´4 30´1 3´8 NO Límites RD 509/1996 70-90 75 70-90 80 70-80 PROYECT 1: lower course 2.- INTEGRATED WATER CYCLE IN GUADALETE RIVER WASTEWATER
  28. 28. Código Punto de muestreo Habitantes Porc % Hab- equiv Código Punto de muestreo Habitantes Porc % Hab- equiv CUENCA ALTA CUENCA BAJA U-10 Setenil 3 016 0,93 2 491 U-31 Villamartín 12 145 3,75 35 950 U-05 Alcalá del V 5 355 1,65 2 602 U-33 Bornos 8 164 2,52 6 310 U-24 Torrealháquime 877 0,27 930 U-02 Arcos 29 420 9,09 92 183 U-04 Olvera 8 585 2,65 18 698 U-38 Espera 3 909 1,21 6 215 U-11 Grazalema 1 828 0,56 3 149 U-25 Majarromaque 850 0,26 451 U-15 Zahara 1 556 0,48 2 577 U-09 La Barca 3 800 2,52 11 077 U-13 El Gastor 1 948 0,60 3 614 U-18 Torrecera 1 200 0,37 4 452 U-06 Algodonales 5 630 1,74 7 584 U-37 Paterna 5 354 1,65 8 986 U-07 Pto. Serrano 6 852 2,12 13 770 U-16 El Torno 1 200 0,37 3 339 U-40 Prado Rey 5 968 1,84 12 389 U-22 S. Isidro 600 0,19 159 U-27 Benamahoma 397 0,12 763 U-20 La Ina 800 0,25 155 U-12 El Bosque 2 004 0,62 1 257 U-29 Lomopardo 1 100 0,34 1 117 U-43 Benaocaz 729 0,23 203 U-17 Nª Jarilla 1 600 0,39 1 201 U-03 Ubrique 17 362 5,36 12 032 U-01 Jerez 185 125 57,19 272 162 U-21 Villaluenga 481 0,15 1 487 U-42 Algar 1 644 0,51 4 908 U39 S.José del V 4 210 0,30 7 084 TOTAL C. A. 62 588 19,33 83 546 TOTAL C. B. 261.121 80,66 455.749 TOTAL CUENCA 323.709 100,00 539.295 Coloreado de amarillo: Poblaciones sin EDAR en funcionamiento La CUENCA ALTA con el 19,33 % de la población genera el 15,49 % de loshabitantes-equivalentes La CUENCA BAJA con el 80,66 % de la población genera el 84,44 % de los habitantes-equivalentes 2.- INTEGRATED WATER CYCLE IN GUADALETE RIVER WASTEWATER
  29. 29. Compared study between both basins HABITANTES (2005) VERTIDOS HAB– EQUIV Ratio (h-e)/hm3/año litros/día % Cuenca h-e % Cuenca TOTAL upper course 62 588 6 356 887 17 406 124 18,55 83 546 15,49 1,33 TOTAL lower course 261.121 27.904.669 76.451.148 81,45 455.749 84,51 1,75 TOTAL CUENCA 323.709 34.261.556 93.857.271 100 539.295 100 1,67 Abreviaturas: h = habitantes (h-e) = habitantes-equivalentes 2.- INTEGRATED WATER CYCLE IN GUADALETE RIVER WASTEWATER
  30. 30. Anual load generated by the urban (before the WTP) Carga DBO5 = 5 960 Tm/año de O2. 50,45 % del total Carga DQO = 9 191 Tm/año de O2. 44,69 % del total Carga SS = 4 275 Tm/año de SS. 33,83 % del total Carga DBO5 = 5 854 Tm/año de O2. 49,55 % del total Carga DQO = 11 377 Tm/año de O2. 55,31 % del total Carga SS = 8 096Tm/año de SS. 66,17 % del total 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% DBO5 DQO SS %CARGAANUAL PARÁMETROS CONTROLADOS CARGA ANUAL GENERADA RESTO POBLACIONES JEREZ JEREZ other populations wastewater 2.- INTEGRATED WATER CYCLE IN GUADALETE RIVER WASTEWATER Wastewater WITHOUT treatment Pollution Load (g/day) = Concentration (BOD mg/l O2) x Caudal (m3/day) E-h = Pollution Load / 60 g
  31. 31. 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% DBO DQO SS %CARGAANUAL PARÁMETROS CONTROLADOS CARGA ANUAL DE VERTIDOS AL GUADALETE RESTO POBLACIONES JEREZ Carga DBO5 = 321 Tm/año de O2. 13,79 % del total Carga DQO = 1 104 Tm/año de O2. 23,88 % del total Carga SS = 321 Tm/año de SS. 13,81 % del total Carga DBO5 = 2 006 Tm/año de O2. 86,21 % del total Carga DQO = 3 520 Tm/año de O2. 76,12 % del total Carga SS = 2 003 Tm/año de SS. 86,18 % del total JEREZ other populations Wastewater treated Anual load dicharges by the urban (after SSS) 2.- INTEGRATED WATER CYCLE IN GUADALETE RIVER WASTEWATER Wastewater with treatment
  32. 32. POPULATIONS Discharges m3/ año Anual load dicharges (Tm/year) DBO Tm/año O2 DQO Tm/año O2 SS Tm/año CURRENTLY: Without treatment TOTAL 3.237.967 1.198 1.946 887 FUTURE: With treatment TOTAL 3.237.967 81 405 113 Differences 1.117 1.541 774 Another questions: 1. what is happening with the 8 villages without treatment? (8 populations with 32 676 E-h) 2. when the plant will be built, how much would reduce their annual load? Without treatment 12.371 Tm SS This investigation (2002-2004): 2.324 Tm SS Future: WTP built and operating properly 1.550 Tm SS
  33. 33. 3. Is the quality of the water in the river in good condition? Second project
  34. 34. Código Punto de muestreo UPPER COURSE Majaceite River Ubrique-1 Upstream from WTP Ubrique-2 Downstream from WTP Bosque-1 Upstream from WTP Bosque-2 Downstream from WTP Arcos-1 Upstream from WTP LOWER COURSE Guadalete River Arcos-2 Downstream from WTP Jerez-1 Upstream from WTP Jerez-2 Downstream from WTP ANALYSES T Nitrógeno Fluoruros pH Nitratos Cianuros CE Nitritos Metales Oxígeno Amonio DBO5 Fosfatos DQO Hierro SS Manganeso Point Stations PROjECT 2: Controls on the receiving stream from Guadalete Basin (2002-2004)
  35. 35. Muestras DBO5 mg/l O2 DQO mg/l O2 SS mg/l Ubrique-1 7 13 11 Ubrique-2 14 32 21 El Bosque-1 8 25 15 El Bosque-2 7 23 25 Arcos-1 8 32 15 Arcos-2 37 99 107 Jerez-1 7 31 158 Jerez-2 8 26 170 mg/l PROjECT 2: organic load in the water river Arcos 2: plant not operating properly Jerez 2: diffuse pollution (agricultural land drag, by rainfall and runoff)
  36. 36. River pollution indices: WQI- Water Quality Index (Pesce & Wunderlin, 2000) Ci Parám. Pi 100 90 80 70 60 50 40 30 20 10 0 Rangos de valores analíticos pH 1 7 7-8 7-8,5 7-9 6,5-7 6-9,5 5-10 4-11 3-12 2-13 1-14 CE 2 <0,75 <1,00 <1,25 <1,50 <2,00 <2,50 <3,00 <5,00 <8,00 <12,00 >12 SS 4 <20 <40 <60 <80 <100 <120 <160 <240 <320 <400 >400 NH4 + 3 <0,01 <0,05 <0,10 <0,20 <0,30 <0,40 <0,50 <0,75 <1,00 <1,25 >1,25 NO2 - 2 <0,005 <0,01 <0,03 <0,05 <0,10 <0,15 <0,20 <0,25 <0,50 <1,00 >1,00 NO3 - 2 <0,5 <2,0 <4,0 <6,0 <8,0 <10,0 <15,0 <20,0 <50,0 <100,0 >100,0 PT 1 <0,2 <1,6 <3,2 <6,4 <9,6 <16,0 <32,0 <64,0 <96,0 <160,0 >160 DQO 3 <5 <10 <20 <30 <40 <50 <60 <80 <100 <150 >150 DBO5 3 <0,5 <2,0 <3 <4 <5 <6 <8 <10 <12 <15 >15 OD 4 ≥7,5 >7,0 >6,5 >6,0 >5,0 >4,0 >3,5 >3,0 >2,0 >1,0 >1,0 T 1 21/16 22/15 24/14 26/12 28/10 30/5 32/0 36/-2 40/-4 45/-6 >45/<-6 Todos los valores, excepto pH, en mg/l Conductividad CE en mS/cm
  37. 37. River pollution indices: clasification Punto de muestreo WQI CALIFICACIÓN Ubrique-1 61 MEDIUM Ubrique-2 52 MEDIUM El Bosque-1 56 MEDIUM El Bosque-2 54 MEDIUM Arcos-1 41 BAD Arcos-2 20 VERY BAD Jerez-1 32 BAD Jerez-2 28 BAD WQI Clasification 0-25 Very BAD 25-50 BAD 51-70 MEDIUM 71-90 GOOD 91-100 EXCELENT Parameters analysed (11) pH, CE, SS, NH4, NO3, NO2, Pt, DQO, DBO5, OD, T
  38. 38. Questions…..? 1. How many Wastewater Treatment Plants are in the Guadalete basin? 2. Are according with the law (Directive European Union) 3. Is the quality of the water in the river in good condition? 4. HOW ARE NOW THE TREATMENT PLANTS? Let´s see
  39. 39. 46 % of population without treatment
  40. 40. Report on the situation of waste water treatment in the Province of Cádiz 2.2.3.1. VILLAGES WITHOUT SWT Benaocaz. Vertido a acequia Bornos. Vertido al embalse de Bornos Trebujena. Vertido a acequia San José del Valle. Vertido a arrollo Los Toreros. Tarifa. Pretratamiento ACTUACIÓN PREVISTA OBRAS DECLARADAS DE INTERÉS DE CAA HABITANTES BENAOCAZ EDAR y colectores. No existe proyecto. Existe estudio de alternativas. EDAR y colectores en Benaocaz y Grazalema 693 BORNOS En Proyecto EDAR y colectores Por error no los incluyeron en el Acuerdo, pero son necesidades. La EDAR de Bornos ya está en proyecto 8.074 SAN JOSÉ DEL VALLE EDAR y colectores. A fecha de oct. 2012 no hay terrenos. Existe proyecto de AJEMSA EDAR y colectores en Medina Sidonia, San José del Valle y sus núcleos 4.117 TREBUJENA EDAR y colectores. Actualmente oct. 2012 no existe proyecto EDAR y colectores en Trebujena 6.890 TARIFA Existen terrenos y proyecto. A falta de asignación presupuestaria. Ampliación, EDAR y colectores en Tarifa y sus núcleos 15.217
  41. 41. Report on the situation of waste water treatment in the Province of Cádiz 46 % de la población de la provincia de Cádiz no depuren sus aguas o no lo hacen con las condiciones establecidas (549.814 habitantes).
  42. 42. 2.2 Informe sobre la situación de la depuración de las aguas residuales en la Provincia de Cádiz. 2.2.4. WATER BILL. A quick calculation………………:  CUOTA FIJA: 1 € por vivienda / mes  CUOTA VARIABLE: bloque 1 (< 10 m3) , 0.10 €/m3 consumido  Año 1: se paga 30 % = 0.03 €/m3 consumido  Año 2: 50 % = = 0.05 €/m3 consumido  Año 3: 60 % = = 0.06 €/m3 consumido  Año 4: 80 % = = 0.08 €/m3 consumido  ANDALUCÍA (8.415.490 habitantes) (mayo 2011 – mayo 2012) Año €/m3 Consumo CUOTA VARIABLE Cuota Servicio CUOTA FIJA Total 2012 0,03 12.900.946,17 € 50.492.940,00 € 63.393.886,17 € 2013 0,05 21.501.576,95 € 50.492.940,00 € 71.994.516,95 € 2014 0,06 25.801.892,34 € 50.492.940,00 € 76.294.832,34 € 2015 0,08 34.402.523,12 € 50.492.940,00 € 84.895.463,12 € 296.578.698,58 €
  43. 43. CONCLUSIONS 1. How many Wastewater Treatment Plants are in the Guadalete basin? There are sufficient WTP but their operative were not correctly performing. 2. Are they according with the legislation(Directive European Union) No, and currently most of the Plants are in a worse situation than years ago 3. Is the quality of the water in the river in good condition? No, and probably in a worse situation than 2004 Is Guadalete Basin according to Water Framework Directive for 2015? What is the solution?
  44. 44. Thanks for your attention

×