  1. 1. 秘密▲(保密期) ZXDSL 9210 Guide Inband NA Connected through the Connection Card 1. Use the serial port cable to connect ZXDSL 9210 to the PC. Configure the super terminal of the PC and log onto ZXDSL 9210. 2. Use the erase command to reset the data before making the services available. Reboot the device to make effective the data resetting. DSL# erase 3. It is unnecessary to set the inband MAC address since it is unique by default. 4. Enter the config mode, and set the network administration VLAN (set to 100 here). DSL# configure DSL(config)# add-vlan 100 5. Add the uplink port into the VLAN, and select tag. DSL(config)# vlan 100 3/1 tag 6. Use the ip subnet command to set the inband IP address of the device. You need to plan the IP address of each network element on the whole network, so as to make sure that the IP addresses of the network elements do not conflict with each other. Besides, make sure that the IP address of the inband and outband egresses of the same network element are not in the same network segment. DSL(config)#ip subnet 192.10.10.1 255.255.255.0 100 7. Use the snmp-server host command to set the NA server IP. And set the authentication character of this NA server. The system defaults the authority of the community with the authentication character private as read-and-write. Through this setting, the NA alarm message can be reported to the NA server. DSL(config)#snmp-server host 192.10.10.200 private 8. Enable the trap switch of the port. The default status of this switch is disable. You can operate on the board to enable the trap switch of all ports on this board. DSL# configure slot adsl 2 DSL(cfg-slot-adsl-2)# trap-control enable 9. If the network element and the NA server are not in the same network segment during the NA networking, you need to use the ip route command to configure a static route. DSL(config)#ip route 0.0.0.0 0.0.0.0 192.10.10.2 10. Save the configuration performed on the control switching board, as shown in 本文中的所有信息归中兴通讯股份有限公司所有,未经允许,不得外传 第 1 /8页
  2. 2. 秘密▲(保密期) DSL(config)# exit DSL# copy running-config startup-config Are you sure to save configuration data?[y/n]y Save finished successfully 11. Use the ping command to test whether the network connection is normal and smooth. If normal and smooth, the configuration is completed; if not, please check the above data configuration and the connection of the hardware networking. DSL# ping 192.10.10.200 PING 192.10.10.200:56 data bytes 64 bytes from 192.10.10.200:icmp_seq=0. time=0. ms 64 bytes from 192.10.10.200:icmp_seq=1. time=0. ms 64 bytes from 192.10.10.200:icmp_seq=2. time=0. ms ----192.10.10.200 PING Statistics---- 3 packets transmitted, 3 packets received, 0% packet lost round-tirp(ms) min/avg/max=0/0/0 Ping 192.10.10.200 successfully The outband NA is configured on the control switching board. It is connected to the NA server through the ETH egress on the control switching board, so as to achieve the unified network administration of the devices. Outband NA 1. Use the serial port cable to connect ZXDSL 9210 to the PC, and configure the super terminal of the PC. 2. After logging in, enter the reboot command on the main interface to reboot the device. 3. During the reboot process, if the system prompts “Press 's' to stop auto-boot...”, press the s key within seven seconds to stop the auto boot of the system, so as to enter the VxWorks Boot mode. 4. In the VxWorks Boot mode, use the c command to modify the IP address and gateway of the system outband NA. 本文中的所有信息归中兴通讯股份有限公司所有,未经允许,不得外传 第 2 /8页
  3. 3. 秘密▲(保密期) Use “inet on ethernet (e): 10.61.86.41 10.61.86.40:0xfffffc00” to set the outband IP address and mask. The mask must be hexadecimal, and 0x is the sign of hex. Use “gateway inet (g): 10.61.87.254” to set the gateway address. Note: The IP address of the outband and inband NA’ s should not be in the same network segment. 5. After modifying the IP address and gateway address of the system outband NA, use the command p to check whether the modification is correct. 6. After the check, use the M command to modify the outband MAC address. “Please input the new MAC address: aa0c01” shows that you have to enter the last three characters of the MAC address to modify the outband MAC address. 本文中的所有信息归中兴通讯股份有限公司所有,未经允许,不得外传 第 3 /8页
  4. 4. 秘密▲(保密期) 7. When the parameter configuration is completed, use the @ command to reboot the system. 8. When the system is rebooted successfully, use the show ip subnet command to check whether the parameter configuration for the system outband NA is successful. 9. When the system is rebooted successfully, if the IP address of the outband NA of the network element and that of the NA server are not in the same network segment, you still need to configure a route. (Optional) 10. When the route configuration is completed, use the show ip route command to check whether the NA and route configurations are successful. 11. Set the IP address and authentication character for the NA server on the control switching board. 12. Enable the trap switch of the port. The default status of this switch is disable. You can operate on the board to enable the trap switch of all the ports on this board. 本文中的所有信息归中兴通讯股份有限公司所有,未经允许,不得外传 第 4 /8页
  5. 5. 秘密▲(保密期) 13. When the parameter configuration is completed, use the copy command to save the system configuration performed on the control switching board. Activating Basic Services 2.2.1 Ethernet User Configuration For the access of the Ethernet users, you don’ t need to make special configurations with ZXDSL 9210. The computer can be connected to ZXDSL 9210 directly through the cable or the Ethernet switch. However, in the actual networking, you need to divide the network into different VLAN’ s according to various needs, so as to isolate the ports. 2.2.1.1 Configuration Procedures for Connection through the Connection Interface Board Take the simplest VLAN as an example: The user board is connected to the Ethernet switch through the Ethernet electrical interface of the connection sub-card FEC on the Ethernet connection interface board, and the Ethernet switch is connected to the BAS. It is required to select tag for both the uplink interface of ZXDSL 9210 and the interface of the peer-end Ethernet switch. And you also need to set pvid for the user port. The port pvid must be consistent with vlan id of the VLAN which contains the port. 1. Create a VLAN. 2. Add the Ethernet user port into the VLAN without selecting tag. 3. Set pvid of the user port to VLAN ID. 4. Add the connection port into the VLAN and select tag. 5. Save the configuration. 2.2.1.2 Configuration Procedures for Connection through the Connection Interface Board 1. Create a VLAN. DSL# configure DSL(config)# add-vlan 101 本文中的所有信息归中兴通讯股份有限公司所有,未经允许,不得外传 第 5 /8页
  6. 6. 秘密▲(保密期) 2. Add the user port into the VLAN without selecting tag. DSL(config)# vlan 101 3/4 untag 3. Set pvid of the user port to VLAN ID. DSL(config)# interface ethernet 3/4 DSL(cfg-if-eth-3/4)# pvid 101 4. Add the connection port into the VLAN and select tag. DSL(config)# vlan 101 3/1 tag 5. Save the configuration. DSL# copy running-config startup-config Are you sure to save configuration data? [y/n]y The configuration for Ethernet users is completed by now. 2.2 ADSL User Configuration The ADSL user access can be implemented through the ADSL user interface board. This section introduces only the configuration method for connection through the Ethernet connection board or the control switching board. 2.2.1 Configuration Procedures 1. Create a service VLAN. 2. Add the user port into this VLAN without selecting tag. 3. Set pvid of the user port to VLAN ID. 4. Add the connection port into the service VLAN and select tag. 5. Set the parameter set and alarm parameter set for the ADSL line according to the office requirements. (Optional) 6. Distribute the parameter set and alarm parameter set of the ADSL line to the actual line. (Optional) 7. Set the user port PVC, making it corresponding to the Modem PVC. 8. Save the configuration. 2.2.1.1 Detail Process 1. The operations from Step 1 to Step 4 are the same as those of the Ethernet user configuration (see Section 2.2.1). 2. Create the ADSL line parameter set, which is used to limit the line speed. Use the adsl-profile command for the first time to create a line configuration file. Please note that the name of the line configuration file cannot start with a number. Use the adsl-profile command for the second time to configure parameters for the existed line configuration file. (Optional) DSL(config)# adsl-profile adsl512 This profile do not exist. Would you like to create? [y/n]y 3. Modify the parameters in the ADSL line parameter set. DSL(config)# adsl-profile adsl512 PS:Q-quit AtucConfRateMode[fix(1),adaptAtStart(2),adaptAtRun(3)](Def:2)2// Office-side rate adapting mode 本文中的所有信息归中兴通讯股份有限公司所有,未经允许,不得外传 第 6 /8页
  7. 7. 秘密▲(保密期) AtucConfRateChanRatio [0-100](Def:0)// Office-side rate adapting ratio AtucConfTargetSnrMgn [0-310](Def:60)// Office-side destination noise margin AtucConfMaxSnrMgn [0-310](Def:120)// Office-side max noise margin AtucConfMinSnrMgn [0-310](Def:0)// Office-side min noise margin AtucConfDownshiftSnrMgn [0-310](Def:0)// Office-side decreased noise margin AtucConfUpshiftSnrMgn [0-310](Def:120)// Office-side increased noise margin AtucConfMinUpshiftTime [0-16383](Def:0)// Office-side min time interval for increase AtucConfMinDownshiftTime [0-16383](Def:0)// Office-side min time interval for decrease AtucChanConfFastMinTxRate[0-131040](Def:32)// Min transmission rate of the office-side fast channel AtucChanConfInteMinTxRate[0-131040](Def:32)// Min transmission rate of the office-side interleaved channel AtucChanConfFastMaxTxRate[0-131040](Def:8128):512// Max transmission rate of the office-side fast channel AtucChanConfInteMaxTxRate[0-131040](Def:8128):512// Max transmission rate of the office-side interleaved channel AtucChanConfMaxInterDelay[0-255](Def:32)// Max office-side interleaved delay AturConfRateMode[fixed(1),adaptAtStartup(2),adaptAtRuntime(3)](Def:2)// User-side rate adapting mode (usually select the self-adapting mode) AturConfRateChanRatio [0-100](Def:0)// User-side rate adapting ratio AturConfTargetSnrMgn [0-310](Def:60)// User-side destination noise margin AturConfMaxSnrMgn [0-310](Def:120)// User-side max noise margin AturConfMinSnrMgn [0-310](Def:0)// User-side min noise margin AturConfDownshiftSnrMgn [0-310](Def:0)// User-side decreased noise margin AturConfUpshiftSnrMgn [0-310](Def:120)// User-side increased noise margin AturConfMinUpshiftTime [0-16383](Def:0)// User-side min time interval for increase AturConfMinDownshiftTime [0-16383](Def:0)// User-side min time interval for decrease AturChanConfFastMinTxRate[32-1536](Def:32)//512 Min transmission rate of the user-side fast channel AturChanConfInteMinTxRate[32-1536](Def:32)//512 Min transmission rate of the user-side interleaved channel AturChanConfFastMaxTxRate[32-1536](Def:1024):512// Max transmission rate of the user-side fast channel AturChanConfInteMaxTxRate[32-1536])(Def:1024):512// Max transmission rate of the user-side interleaved channel AturChanConfMaxInterDelay[0-255](Def:32)// User-side max interleaved delay 4. Create the alarm parameter set for the ADSL line DSL(config)# adsl-alarm-profile alarm512 This profile do not exist. Would you like to create? [y/n]y 5. Modify the parameters in the alarm parameter set of the ADSL line. (Optional) DSL(config)# adsl-alarm-profile alarm512 PS:Q-quit AtucThresh15MinLofs[0-900](Def:0)// Alarm threshold for the office-side 15 minutes frame loss AtucThresh15MinLoss [0-900](Def:0)// Alarm threshold for the office-side 15 minutes signal loss AtucThresh15MinLols [0-900](Def:0)// Alarm threshold for the office-side 15 minutes link loss AtucThresh15MinLprs [0-900](Def:0)// Alarm threshold for the office-side 15 minutes power loss 本文中的所有信息归中兴通讯股份有限公司所有,未经允许,不得外传 第 7 /8页
  8. 8. 秘密▲(保密期) AtucThresh15MinESs [0-900](Def:0)// Alarm threshold for the office-side 15 minutes error code second AtucThreshFastRateUp [0-8128](Def:0)// Alarm threshold for the office-side 15 minutes fast channel rate increase AtucThreshInteRateUp [0-8128](Def:0)// Alarm threshold for the office-side 15 minutes interleaved channel rate increase AtucThreshFastRateDown[0-65535](Def:0)// Alarm threshold for the office-side 15 minutes fast channel rate dncrease AtucThreshInteRateDown[0-65535](Def:0)// Alarm threshold for the office-side 15 minutes interleaved channel rate dncrease AtucInitFailTrapEnable[enable(1),disable(2)](Def:2)1//Office-side alarm of allowing initialization failure AturThresh15MinLofs [0-900](Def:0)// Alarm threshold for the user-side 15 minutes frame loss AturThresh15MinLoss [0-900](Def:0)// Alarm threshold for the user-side 15 minutes signal loss AturThresh15MinLprs [0-900](Def:0)// Alarm threshold for the user-side 15 minutes link loss AturThresh15MinESs [0-900](Def:0)// Alarm threshold for the user-side 15 minutes power loss AturThreshFastRateUp [0-900](Def:0)// Alarm threshold for the user-side 15 minutes error code second AturThreshInteRateUp [0-900](Def:0)// Alarm threshold for the user-side 15 minutes fast channel rate increase AturThreshFastRateDown[0-900](Def:0)// Alarm threshold for the user-side 15 minutes interleaved channel rate increase AturThreshFastRateDown[0-900](Def:0)// Alarm threshold for the user-side 15 minutes interleaved channel rate increase AturThreshInteRateDown[0-900](Def:0)// Alarm threshold for the user-side 15 minutes fast channel rate dncrease 6. Configure the generated ADSL line file to the actual line, so as to implement the speed limit function. (Optional) DSL(config)# slot adsl 2 DSL(cfg-slot-adsl-2)# adsl profile adsl512 7. Configure the generated ADSL line alarm file to the actual line. DSL(cfg-slot-adsl-2)# adsl alarm-profile alarm512 8. Configure the PVC: Make the port PVC corresponding to the MODEM PVC. DSL# configure DSL(config)# slot adsl 2 DSL(cfg-slot-adsl-2)# atm pvc 8:81 Note: Set the ADSL port PVC on the ADSL user interface board to the same as that of the peer-end MODEM PVC. 9. Save the configuration. DSL# copy running-config startup-config Are you sure to save configuration data? [y/n]y The service configuration for the ADSL user board is completed by now. 本文中的所有信息归中兴通讯股份有限公司所有,未经允许,不得外传 第 8 /8页

×