• Micro cantilevers are the most simplified MEMS
based devices
• The overall sensitivity of micro cantilever
depends on bo...
• A micro cantilever is a device that can act as a
physical, chemical or biological sensor by detecting
changes in cantile...
• In Micro Electro Mechanical Systems (MEMS)
• Temperature Sensors / Heat Sensors
• Viscosity Sensors
• In physical, chemi...
• Christiane Ziegler, (2004) explains about the cantilevers based
bio-sensors. He explains mainly about the theory of cant...
• Stoney equation is the main basis for the
calculation of deflection in micro cantilevers
• The Stoney equation used for ...
Case-1:
polymer - su8
Pressure = 0.01 N/mm2
Surface stress ( ) = 0.8 N/m
Elastic Modulus (E) = 5Gpa
Poisson ratio (v) = 0....
•
= 0.37µm
Deflection (Z) =0.37µm
IN SIMILAR WAY THE DEFLECTION IS BEING FOUND FOR DIFFERENT VALUES OF STRESS
• The software used for the analysis of
deflections in cantilevers is “ANSYS”.
• ANSYS is general-purpose finite element
a...
• By using Ansys the deflections have been found for
different values of Surface stress
• Case 1:
DMX= 0.479E-06
Case-2: Case-3:
Case-4:
DMX=.766E-06
SMN=58904
SMX=.912E+07
DMX=.766E-06
SMN=57359
SMX=.105E+08
Pressure (p)
N/mm2
Surface Stress(∆σ)
N/m
Simulation
deflection(µm)
Analytical
Deflection(µm)
Error (µm)
0.01 0.8 0.42 0.3...
• The deflection of the C shaped Micro cantilever
was Calculated using Stoney’s equation
mathematically and the same canti...
Micro Cantilevers using ansys
Micro Cantilevers using ansys
Micro Cantilevers using ansys
Micro Cantilevers using ansys
Upcoming SlideShare
Loading in …5
×

Micro Cantilevers using ansys

12,380 views

Published on

Published in: Design, Technology, Business
  • Be the first to comment

Micro Cantilevers using ansys

  1. 1. SRI KALAHASTEESWARA INSTITUTE OF TECHNOLOGY SKIT Road, Panagal, SRIKALAHASTI -517640, Chittoor Dist (Approved by A.I.C.T.E., New Delhi & Affiliated to JNTU, Anantapur) Department Of Mechanical Engineering, Project on ANALYTICAL AND SIMULATION ANALYSIS OF C-SECTION MICRO CANTILEVERS USED IN MEMS APPLICATIONS , under the guidance of Sri. C.VIJAYA BHASKAR REDDY M.Tech,; M.I.S.T.E,; (Ph.D), Assistant Professor (Sr) C.RAJA SEKHAR 08381A0339 S.RADHA KRISHNA 08381A0338 G.V.R.TEJA 08381A0356 R.ADITYA 08381A0301 V.NITHIN KRISHNA 08381A0333 BY
  2. 2. • We are very thankful to Our beloved Principal and HOD of Mechanical Engg Dr.B.Jayachandraiah Garu for giving us the opportunity to do our main project • We are also thankful to our Incharge HOD Sri.C.Bhaskar Reddy for giving us permission in doing the project • We express our gratitude to our Guide Sri.C.Vijaya Bhaskar Reddy for encouraging and giving timely suggestion in completing the project. • We are thankful to our Non Teaching staff of mechanical department for their co-operation during the project work. • We dedicates this work to our Parents and teachers who imparted the knowledge.
  3. 3. • Micro cantilevers are the most simplified MEMS based devices • The overall sensitivity of micro cantilever depends on both the deflection and stress of the cantilever • The stress and deflection is being found by Stoney equation analytically and simulated in ansys software • values are being compared and the errors are being found.
  4. 4. • A micro cantilever is a device that can act as a physical, chemical or biological sensor by detecting changes in cantilever bending or vibrational frequency. The polymer su8 is used in this project • Micro cantilevers are a million times smaller than the diving board having dimensions in microns (Micro= 10-6 m)
  5. 5. • In Micro Electro Mechanical Systems (MEMS) • Temperature Sensors / Heat Sensors • Viscosity Sensors • In physical, chemical and biological sensing
  6. 6. • Christiane Ziegler, (2004) explains about the cantilevers based bio-sensors. He explains mainly about the theory of cantilevers biosensors. The most common method to measure the deflection of a cantilever is the optical lever technique • Mo Yang et al, (2003) describes about the High sensitivity piezoresistive cantilever design and optimization for analyte- receptor binding. • Mohd. Zahid Ansari et al(2008) explains about the Study on Increasing Sensitivity of RectangularMicrocantilevers Used in Biosensors. He calculated the deflections using Stoney equation
  7. 7. • Stoney equation is the main basis for the calculation of deflection in micro cantilevers • The Stoney equation used for the calculation of deflection is [Mohd. Zahid Ansari et al(2008) ]
  8. 8. Case-1: polymer - su8 Pressure = 0.01 N/mm2 Surface stress ( ) = 0.8 N/m Elastic Modulus (E) = 5Gpa Poisson ratio (v) = 0.22 Length (l) = 200µm Width (w) = 120µm Thickness (t) = 2.8µm Area (a) = 17600µm2
  9. 9. • = 0.37µm Deflection (Z) =0.37µm IN SIMILAR WAY THE DEFLECTION IS BEING FOUND FOR DIFFERENT VALUES OF STRESS
  10. 10. • The software used for the analysis of deflections in cantilevers is “ANSYS”. • ANSYS is general-purpose finite element analysis (FEA) software package. • This type of analysis is typically used for the design and optimization of a system for too complex to analyze by hand
  11. 11. • By using Ansys the deflections have been found for different values of Surface stress • Case 1: DMX= 0.479E-06
  12. 12. Case-2: Case-3: Case-4:
  13. 13. DMX=.766E-06 SMN=58904 SMX=.912E+07
  14. 14. DMX=.766E-06 SMN=57359 SMX=.105E+08
  15. 15. Pressure (p) N/mm2 Surface Stress(∆σ) N/m Simulation deflection(µm) Analytical Deflection(µm) Error (µm) 0.01 0.8 0.42 0.37 0.05 0.012 1.05 0.57 0.5 0.07 0.013 1.14 0.62 0.54 0.08 0.014 1.2 0.67 0.59 0.08 0.015 1.3 0.70 0.61 0.09
  16. 16. • The deflection of the C shaped Micro cantilever was Calculated using Stoney’s equation mathematically and the same cantilever is (analyzed) simulated using Ansys software. • Since von mises stress is less than stress intensity the model is in safe zone • The results shows that the analysis with mathematical and simulated are with in a minimum error of .1 (10%) at an approval.

×