Successfully reported this slideshow.
We use your LinkedIn profile and activity data to personalize ads and to show you more relevant ads. You can change your ad preferences anytime.
MicroBASIC
                                        PRIMA.
                                     Parameters and
            ...
TECHNICAL DOSSIER
                                  PRE-ASSEMBLED ELECTRICAL INSTALLATION MICROBASIC




                 ...
TECHNICAL DOSSIER
                                PRE-ASSEMBLED ELECTRICAL INSTALLATION MICROBASIC



CHAPTER 4. MICROBASI...
TECHNICAL DOSSIER
                                                                                    PRE-ASSEMBLED ELECTR...
TECHNICAL DOSSIER
                            PRE-ASSEMBLED ELECTRICAL INSTALLATION MICROBASIC


Relays:

• RB: descent.
A...
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Mtmtipmbprima30 Gb
Upcoming SlideShare
Loading in …5
×

Mtmtipmbprima30 Gb

4,332 views

Published on

Published in: Business, Sports
  • Be the first to comment

Mtmtipmbprima30 Gb

  1. 1. MicroBASIC PRIMA. Parameters and user interface Technical Dossier V3.0, APR.05 Parameters and user interface English / MTIPIEPMB300GB (chap. 4)
  2. 2. TECHNICAL DOSSIER PRE-ASSEMBLED ELECTRICAL INSTALLATION MICROBASIC TABLE OF CONTENTS CHAPTER 4. MICROBASIC CONTROL UNIT OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 4.1. Compatibility. MicroBasic - MicroBasic Prima . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 4.2. MicroBASIC PRIMA board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 4.2.1 Main components and general scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 4.2.2 Information provided by the controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 4.2.2.1. Indicator lights (leds) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 4.2.2.2. 3-digit display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 4.2.2.2.1. First information provided . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 4.1.2.2.2. Program mode information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 4.2.2.2.3. Information in normal operation . . . . . . . . . . . . . . . . . . . . . . . . . . 77 4.2.2.2.4. Information during inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 4.2.2.2.5. Information in special situations . . . . . . . . . . . . . . . . . . . . . . . . . . 81 4.2.3. Configuration and adjustment of parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 4.2.3.1. Parametrization method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 4.2.3.1.1. Elements for configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 4.2.3.1.2. Types of parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 4.2.3.1.3. Parametrization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 4.2.3.3. Description of parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 4.2.4. Basic functional operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 4.2.4.1. Commissioning. Return Control Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 4.1.4.2. Normal operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 4.2.4.3. Inspection operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 4.2.4.4. Emergency operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 4.2.4.5. Other operations and functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 4.2.4.5.1. Opening and closing of doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 4.2.4.5.2. Relevelling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 4.2.4.5.3. Fireman control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 4.2.4.5.4. Mixed selective control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 4.2.4.5.5. Asymmetric lifts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 4.3. Printed circuit board AMB1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 4.3.1. Main components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 4.3.2. Information provided by the board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 4.3.3. Configuration of parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 4.3.4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 4.4. Printed circuit board AMB2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 4.4.1. Main components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 4.4.2. Information provided by the board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 4.4.2.1. Led light indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 4.4.2.2. 4-Digit display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 4.4.2.2.1. RUN Mode: information indication . . . . . . . . . . . . . . . . . . . . . . . . 108 4.4.2.2.2. PROGRAM Mode: Information indication . . . . . . . . . . . . . . . . . . . . 110 4.4.2.2.3. Special indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 4.4.3. Configuration and adjustment of parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 4.4.3.1. Configuration elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 4.4.3.2. PROGRAM Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 4.4.3.3. Parameters configuration table for MicroBASIC control unit with additional AMB2 board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 4.4.3.4. Configuration of parameters on the AMB2 circuit board . . . . . . . . . . . . . . . . . 113 4.4.4. Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 4.4.4.1. Operation in normal configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 4.4.4.2. Redundant operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 4.4.5. Control unit errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 V3.0, APR.05 I MTIPIEPMB300GB
  3. 3. TECHNICAL DOSSIER PRE-ASSEMBLED ELECTRICAL INSTALLATION MICROBASIC CHAPTER 4. MICROBASIC CONTROL UNIT OPERATION 4.1. Compatibility. MicroBasic - MicroBasic Prima The new MicroBasic Prima board could replace any MicroBasic board of any previous version with no modification on existing wiring. This is possible because some parameters have been included for this purpose. See the following changes according to pannel type, its relation to software version and the parameter (and value) that has to be modified to achieve this compatibility. MICRO FUNCTIONS ACCORDING TO VERSION MICRO BASIC BASIC PRIMA INSTALACION SOFTWA SOFTWA TYPE RE RE STOP OVER- WELDED LEVELING VERSION TEMPERATURE CONTACTOR CRITERION VERSION (P/V) (P/V) (P/V) (P/V) Terminal J Terminal F Stopped aAnalisys No 131 / 132 (30 / B) (24/A no leveling / 133 (33 / A) (30 / B) (29 / B) 24/C leveling Whitout enlargement Terminal J Terminal F Stopped aAnalisys YES Electric. 1 and 2 134 (30 / B) speed and (33 / A) (30 / B) (29 / B) (CURRENT) oleodinamic 135 / 137 see parameter Terminal J Stopped and YES / 141 / selection table Movement Analisys From 165 146 (33) (Actual) (CURRENT forward Terminal J Terminal J Stopped aAnalisys NO 995 (30 / B) (24/A no leveling (33 / A) (30 / B) (29 / B) 24/C leveling Whitout TerminalJ Terminal F Stopped and YES enlargement E13 / E15 (30 / B) Movement Analisys 3VFMAC (33 / A) (30 / B) (actual) (CURRENT) E19 / 136 see parameter Terminal J Stopped and YES / 139 / selection table Movement Analisys 142 / 148 (33) (actual) (CURRENT) (CURRENT) 50A / 50B Terminal J Terminal F Stopped aAnalisys No / 50C / (30 / B) (24/A no leveling 50D / 50E (33 / A) (30 / B) (29 / B) 24/C leveling Whit enlargement Terminal J Terminal F Stopped aAnalisys YES From 171 51C (30 / B) AMB1 / AMB2 forward (33 / A) (30 / B) (29 / B) (CURRENT) see parameter TerminalJ Stopped and YES 52A selection table Movement Analisys (33) (CURRENT) (CURRENT) (CURRENT) P/V is the parameter y its suitable value for compatibility between microBASIC Prima board and the one to be replaced, regardless of the version. As an example, if we replace a V134 board in a hydraulic lift with open doors releveling: Parameter 24, is C value, because is old directive and has releveling. Parameter 29, is B value, because is welded contactor with stopped lift. Parameter 30, is B value, because is over temperature in F terminal with overload and STOP function is in J terminal . Parameter 33, is A value, because STOP is in J terminal and has any other value unless in this terminal over temperature has not been analysed. V3.0, APR.05 Page 71 MTIPIEPMB300GB
  4. 4. TECHNICAL DOSSIER PRE-ASSEMBLED ELECTRICAL INSTALLATION MICROBASIC 4.2. MicroBASIC PRIMA board 4.2.1 Main components and general scheme CONFIGURATION ELEMENTS Q1 R62 R21 T1 T2 P4 C88 U29 R87 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 C90 75176B P3 C36 C34 C78 D3 D2 D1 D8 X1 C79 C87 C77 SC SP IMP EMERG R76 C46 R19 NO LEVEL R78 PL1 R77 DL11 DL7FF1 D69 R64 R60 U16 R24 R8 D15 D9 F5 / FF1 R36 D96 R59 U9 R23 P2 R9 D92 R7 R67 R61 + DZ1 D87 k SW 74HC165 D10 R56 U27 DM9368 C85 R74 R85 U26 C86 UDN 2543 R75 R14 SW j TLP-521 ST9040 U24 R15 C80 RMINV RME2 RME1 RL4 R65 RL3 RL2 i 74HC165 U23 +5V X16 DL9 h DZ35 U28 S/N U4 C45 C57 RME D95 RME TLP-521 C81 U18 U22 U30 U19 R63 g 74HC165 D75 D88 U10 R81 D94 f C92 74HC164 74HC14 U17 R79 R80 LM2825 V8 R17 e D76 D77 D78 C91 C89 FF2 UDN2981 R57 U15 DL10 d 103 R51 FF2 ULN2003 + DL10 RDIP R55 R52 C44 C67 C47 C74 C72 c R45 C69 +24V DZ26 R11 R50 C68 D64 DZ27 DZ28 DZ29 DZ30 DZ31 DZ32 DZ33 R43 R46 PR3 PR4 b C58 C50 C49 R53 C55 C53 a R47 R18 U13 C51 C52 C76 C56 C54 R83 R82 DZ34 C48 R49 C59 C60 C61 C62 C63 C64 C65 C66 R48 PR5 PR6 PR2 C71 C73 R71 U5 R69 U6 R73 U7 R12 C75 C70 FT D40 D55 D63 D85 D81 D82 RBCAB FM D42 D53 D61 F6 / FL F4 / FT F1 / FM P1 D5 D86 UDN2987 UDN2987 UDN2987 D52 R54 D43 D60 D79 DL8 16 RBCAB D44 D51 D59 FL J4 RM DL1 RB RS D68 RVR D83 DL5 +24 D45 D50 D58 RDIP D80 RMT RMR J2 DL3 DL4 DL6 15 D84 R5 R1 R3 R4 R6 P5 VREG D46 D47 D49 D48 D57 D56 D90 R10 D4 D1 D7 D3 D2 14 R70 R72 R68 D41 D54 D62 13 0VCC RET C30 C31 R39 C32 C29 P5 RET RMT2 RMT3 RMT1 RM RMR RB RS RVR 12 74HC165 RL21 RL7 RL13 RL12 RL10 RL6 RL8 RL9 RL11 74HC165 74HC165 C27 C28 J3 11 U1 U2 U3 10 RBEXT C18 C17 C16 C15 C10 C13 C12 C11 C14 C26 C24 C25 C23 C19 C20 C21 C22 C3 C5 C7 9 C4 C6 C9 C8 8 DZ17 DZ16 DZ15 DZ14 DZ13 DZ12 DZ11 DZ10 DZ25 DZ23 DZ24 DZ22 DZ18 DZ19 DZ20 DZ21 DZ2 DZ3 DZ4 DZ5 DZ9 DZ8 DZ7 DZ6 RLS RLB RLDO RMP RZS ROPC ROPA D12 7 R32 RL22 C119 6 D11 RLS RLB RLDO RMP RZS ROPC ROPA 5 R31 R30 R29 C2 RL18 RL19 RL20 RL14 RL5 RL17 RL16 D92 RDIP RDIP RDIP D14 R27 R28 4 D66 3 RL1 RPA R25 R26 D22 D25 D23 D16 D31 D17 D30 D18 D29 D19 D28 D20 D27 D21 D26 D24 D39 D37 D38 D36 D35 D34 D33 D32 2 D13 1 110 J1 C37 F3 CH1 CH2 FOP V4 109 111 112 113 114 115 116 117 118 119 120 +24 A B C D 213 217 218 215 294 214 105 0VCC104 226 220 228 10 T 103 5 207 V3 CC1 CC2 2 0VCC 00 203 106 207 105 217 +12F 208 102 9 220 T 103 218 0VP 223 222 221 V5 CC3 C38 PCB MicroBASIC SERIGRAPHY OF COMPONENTS Jumpers POINTS SIGNALLING J1 . Do no fix a jumper if CFE (emergency final contact) is used. ON THE DISPLAYS J2 . Fix a jumper, except for 1-speed electric lifts. D3 D2 D1 J3 . Only fix a jumper in case of universal control unit. J4 . Fix a jumper except for hydraulic lifts with Kleeman power unit. SC SP IMP PULSE SERIES : • ON . PULSE (LIT) Fuses • OFF . NO PULSE (NOT LIT) FOP . Operator fuse ( 3A ). DOOR SERIES : FM . Control unit fuse ( 2A ). • ON . CLOSED (LIT) • OFF . OPEN (NOT LIT) FT . Fuse power supply 5vdc ( 1A ), max ( 1A ) LOCK SERIES : FL . Signals fuse ( 1A ), max ( 3A ) • ON . CLOSED (LIT) FF1 . Fuse power supply 24 vdc ( 3A ), max ( 3A ) • OFF . OPEN (NOT LIT) FF2 . Fuse 20 Vs ( 3A ), max ( 3A ) CC1 . CC2 . CC3 . CH1 . CH2 Connections terminals in car and shaft P4 P1, P2, P3 Communication channel, series (RS - 485) for duplex connections with Wiring connection terminals in extension AMB1 and AMB2 controller Pins Pin 103 . Aerial connection pin. Safety series reading. Pin RME . Aerial connection pin. Times RME for hydraulic lifts with cam. Pin 207 . Aerial connection pin with leveller 538. Indicator light between floors. V3.0, APR.05 Page 72 MTIPIEPMB300GB
  5. 5. TECHNICAL DOSSIER PRE-ASSEMBLED ELECTRICAL INSTALLATION MICROBASIC Relays: • RB: descent. Active when the car starts or is performing a service in descent, 24Vdc. With red indicator light. • RCAB: car calls. Deletes car calls during inspection (terminal 109), 24Vdc. • RBEXT: outside calls. Deletes outside calls if JUMPER J3 is fixed (UNIVERSAL configuration) and relay is connected during service of lift (terminal 110), 24Vdc. • RET: start-up (hydraulic lifts). Forced draught (electric lifts), 24 Vdc. RUN signal in 3VFMAC. • RPA: RZS control relay. Directly governed by the microcontroller, enables activating RZS when the CPS safety contact (terminals 00, 103) is closed, 24Vdc. • RLB: descent indicator light, 24Vdc. • RLDO: indicator light free (not active) and occupied (active), 24Vdc. • RLS: ascent indicator light, 24Vdc. • RM: run. Active when the car is moving, 24Vdc. With red flashing indicator light. • RMP: door series. Relay with 110Vac which is activated when ‘semiautomatic’ landing doors are closed, if contacts of safety series have been previously closed. With indicator light: on central digit of PCB MicroBASIC display. • RMR: inspection. Active during inspection, 24Vdc. With red indicator light. • RMT: voltage applied to control unit. There are 3 relays. Active during normal operation. Not active during emergency operation in hydraulic lifts, 24Vdc. With green indicator light. • ROPA: automatic door opening relay, commands doors to open. • ROPC: automatic door closing relay, commands doors to close. • RS: ascent. Active when the car starts or is performing a service in ascent, 24 Vdc. With red indicator light. • RVR: high speed. Active during high-speed run of car. With red indicator light. • RZS: safety area. Active when contact CPS ‘terminals 00, 103’ is closed and microcontroller commands bridging of doors, locks and car doors series. This occurs when the car is in the unlocking area (and the safety contact or circuit connected to terminals 00 and 103 is closed). If, in this case, the car is running at slow speed, control unit starts advanced door opening; (approach with doors open). This also happens during re-levelling with open doors, 110Vac. V3.0, APR.05 Page 73 MTIPIEPMB300GB

×