Fire tecpro engels ppt

706 views

Published on

Cabinet Fire Protection
For Data & Server Rooms

Published in: Technology
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
706
On SlideShare
0
From Embeds
0
Number of Embeds
2
Actions
Shares
0
Downloads
12
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Fire tecpro engels ppt

  1. 1.
  2. 2. FireTecPro fastest possible fire detection<br />FireTecPro fire safety for switch and server cabinets – ultra compact, with maximum protection<br />
  3. 3. Small cause big consequences!<br />FireTecPro rapid detection, where it is needed!<br />
  4. 4. Fire in cabinets<br />Causes:<br />Overload <br />Bad contacts <br />defective parts<br />FireTecPro rapid detection, where it is needed!<br />
  5. 5. Survival duration of companies after total failure of IT systems<br />8% up to 1 day <br />43% up to max. 3 days 49% more than 3 days * <br />source Debis (2006<br />FireTecPro rapid detection, where it is needed!<br />
  6. 6. c<br />Three fast steps to a better security!<br />Fastest possible, highly sensitive smoke detection by semi aspiration and optional climate control. <br />Power shutdown, extracts the source path for further enlargement.<br />Extinguishing with gases that are not harmful to nature and equipment (FM200/NOVEC 1230)<br />FireTecPro rapid detection, where it is needed!<br />
  7. 7. Unique Selling Points FireTecPro<br /><ul><li>Fire protection on 19 inch (482, 6 mm)
  8. 8. Quick detection by aspiration
  9. 9. Simple Assembly
  10. 10. An “on top version possible for full cabinets
  11. 11. Ethernet networking opportunities via I-BOX ©,
  12. 12. Detection and extinguishing in a (2HE height 88, 9 mm)
  13. 13. Can be used in existing and new installations
  14. 14. Addable for multiple sensors.
  15. 15. Plug & Play </li></ul>FireTecPro rapid detection, where it is needed!<br />
  16. 16. 1. 2 multi sensors <br />2. Emergency power supply<br />3. IP communication board (optional) <br />4. Emergency Power Shut Down Relays (optional) <br />5. Peripheralelectricalconnections<br />6. Adaptor for main power supply <br />7. Mainboard<br />8. LCD front panel display <br />9. Key switch <br />10. Emergency release button <br />11. Suction fan <br />12. Input main power supply <br />13. Extinguishing agent containers with electrically controlled release <br />14. Pressure display <br />15. Extinguishingnozzle<br />Componenten<br />
  17. 17.  <br />FireTecPro 1.7 m³ <br /><ul><li>1.7 cubic meter Novec1230 flood capability
  18. 18. Designed to fit in cabinets of minimal 600 mm
  19. 19. Low gas pressure warning
  20. 20. 1st and 2nd stage fire alarm
  21. 21. LCD display shows status
  22. 22. User can make personal adjustments in the software by a simple program, shown on the LCD
  23. 23. Optional aspiration system is possible for areas with high airflow
  24. 24. FireTecPro can, in case of a fire incident, control and shut-down the power in the cabinet </li></ul> <br /> FireTecPro rapid detection, where it is needed!<br />
  25. 25.  <br />FireTecPro 3.2 m³ <br /><ul><li>3.2 cubic metre Novec1230 flood capability
  26. 26. The same capacities as FireTecPro 1.7 m³
  27. 27. For use in cabinets with a very high airflow </li></ul> <br /> <br />FireTecPro rapid detection, where it is needed!<br />
  28. 28.  <br />FireTecPro + aspiration<br /> <br /><ul><li>Faster response by sensitive detection
  29. 29. System takes air samples though the entire cabinet, which causes a faster response when the fire is at the bottom of the cabinet
  30. 30. For use in cabinets with a very high airflow
  31. 31. Permanent coincident alarm to exclude false alarms
  32. 32. Dust sensor combined with an optical smoke detector </li></ul> <br /> <br />FireTecPro rapid detection, where it is needed!<br />
  33. 33. FireTecPro & I-BOX©<br /><ul><li>Monitors the area where the FireTecPro is active
  34. 34. Includes inputs to monitor the entire room
  35. 35. Shocks, temperature, humidity, airflow, access control (card readers), etc.
  36. 36. Monitors current on PDU
  37. 37. Non specific analogue and digital inputs
  38. 38. Real time condition, status and alarm monitoring </li></ul> <br /> <br /> <br /> <br />FireTecPro rapid detection, where it is needed!<br />
  39. 39. Suitable for the following cabinet dimensions<br />600mm x 600mm (+ Duo kast) <br />800mm x 800mm (+ Duo kast) <br />1000mm x 800mm (+ Duo kast) <br />1100mm x 800mm (+ Duo kast) <br />1200mm x 800mm (+ Duo kast) <br />FireTecPro rapid detection, where it is needed!<br />
  40. 40.
  41. 41.
  42. 42.
  43. 43.
  44. 44.
  45. 45. FireTecPro & NOVEC 1230<br /><ul><li>Novec 1230 is a non-conductive fluid, when released it is a very fine mist and will focus on the fire. There it isolates the heat of the fire and uses its own ability to cool to extinguish the fire faster.
  46. 46. Novec 1230 is capable of extinguishing fires classified as A, B, C, E and F, therefore it is more than fit for use in the FireTecPro </li></ul> <br />FireTecPro, snelle detectie waar het nodig is!<br />
  47. 47. Demonstration with NOVEC1230<br />
  48. 48. FireTecPro ... your fire extinguished in a fraction of a second for any serious damage can occur. <br />Safety at the heart of your operational systems.<br />WWW.FIRETECPRO.COM<br />

×