E xact micro 10 photometer v4

1,160 views

Published on

Published in: Business, Technology
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
1,160
On SlideShare
0
From Embeds
0
Number of Embeds
3
Actions
Shares
0
Downloads
3
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

E xact micro 10 photometer v4

  1. 1. 1 eXact® Micro 10 Methodology for Poolside Testing www.sensafe.com / its@sensafe.com
  2. 2. 2 What makes a good test? 1. Test is acceptable or compliant 2. Test is appropriate for the staff technical ability 3. Test is robust, reagents and equipment are reliable & stable in summer heat 4. Test is not affected by interferences 5. Test is accurate when staff performs the test correctly
  3. 3. eXact® Photometers • 0.01 ppm (mg/L) precision • 4 ml built-in, built-in cell • Automatic countdown timing • 20 Test memory for each direct read test • Incorporates eXact® Strip technology patented EZ-3 method (Fill, Dip and Read) • No color matching • Lightweight and waterproof (IP-67) meter • CE certified 3
  4. 4. EZ-3™ Reagent Delivery Method 4
  5. 5. eXact® Micro 10 Instructions 5 I n d e x : P a r a m e t e r P a g e M E N U T o t a l A lk a lin it y 4 A L 1 p H 5 P H 2 F r e e C h lo r in e ( D P D - 1 ) 6 C L 3 C o m b in e d C h lo r in e ( D P D - 3 ) 7 C L 3 B r o m in e 8 C L 3 T o t a l C h lo r in e ( D P D - 4 ) 8 C L 3 P h o s p h a t e 9 P O 4 C a lc iu m H a r d n e s s 1 0 C A 5 C o p p e r 1 0 C U 8 C h lo r id e ( S a lt ) 1 1 C H 6 C y a n u r ic A c id 1 2 C Y 7 H y d r o g e n P e r o x id e C o n v e r s io n 1 5 C Y 7 A b o u t Y o u r P h o t o m e t e r 3 T ip s f o r B e s t A c c u r a c y 1 3 B a t t e r y In s t a lla t io n 1 4 W a r r a n t y ( 2 y e a r ) 1 4 R e o r d e r In f o r m a t io n 1 5 U S E P A C o m p lia n c e 2 , 1 6 K it C o m p o n e n t s 1 6 V is it u s o n lin e a t s e n s a f e .c o m /m ic r o 1 0 f o r u p -t o -d a t e p r o d u c t in f o r m a t io n & N E W t e s t s a v a ila b le . I D E A L F O R T E S T I N G P O O L S A N D S P A S . A C C E P T E D B Y M O S T H E A L T H D E P A R T M E N T S F O R C O M M E R C I A L P O O L A N D S P A T E S T I N G . T h e e X a c t ® M i c r o 1 0 A d v a n c e d P h o t o m e t e r S y s t e m h a s b e e n d e s i g n e d f o r u s e w i t h t h e e X a c t ® S t r i p M i c r o r e a g e n t d e l i v e r y s y s t e m . ® A d v a n c e d P h o to m e te r S y s te m U S E P A , D IN , & IS O C o m p lia n t f o r F r e e , C o m b in e d , & T o t a l C h lo r in e T e s t in g ( 4 5 0 0 - C L G , D IN S t a n d a r d 3 8 4 0 8 G 4 , IS O 7 3 9 3 / 2 ) ® M a n u f a c t u r e d B y : I n d u s t r ia l T e s t S y s te m s , I n c . P h o n e : - I N S I D E T H E U . S . - O U T S I D E T H E U . S . F a x : I T S @ S E N S A F E .C O M W W W . S E N S A F E .C O M w w w .p o o lc h e c k o n lin e .c o m M i c r o 1 0 i s M a n u f a c t u r e d a n d t e s t e d i n a n I S O 9 0 0 1 F a c i l i t y T o p r e v e n t w a r r a n t y is s u e s , y o u m u s t r e g is te r y o u r o w n e r s h ip w ith in 3 0 d a y s o f p u r c h a s e a n d in c lu d e th e s e r i a l n u m b e r ( o n b o tto m o f M ic r o 1 0 M e te r ) a n d v a lid e -m a il a d d r e s s . V is it o u r w e b s ite s e n s a f e .c o m /m ic r o 1 0 t o r e g is te r . B y r e g is te r in g , y o u r 2 -y e a r w a r r a n ty is a c tiv a te d a n d y o u w ill b e u p d a te d w h e n n e e d e d r e g a r d i n g th e M ic r o 1 0 . R e v i s io n 0 5 /1 9 /1 4 S t a n d a r d K it S t a r t e r K it
  6. 6. 6 2 1 2 e X a c t ® R 0 5 1 9 1 4 A L 1 P H 2 C L 3 C L 3 P O 4 C A 5 C H 6 C Y 7 C Y 7 C U 8 2 + 2 1 2 1 2 1 2 1 1 1 1 1 1 E x p e c t e d M e t e r 3 e X a c t ® S t r ip M ic r o 1 0 h a s b e e n d e s ig n e d to o f f e r t h e u s e r a m o r e “ G r e e n ” a n d c o s t - e f fe c tiv e a lte r n a t iv e to te s t in g . In s te a d o f u s in g a 1 0 m l w a te r s a m p le , e X a c t® S tr ip M ic r o 1 0 u s e s a 4 m l w a t e r s a m p le , w h ic h u s e s u p to 6 0 % le s s c h e m ic a l p e r t e s t. T h e a c c u r a c y o f th e m e te r is m a in ta in e d b y d e s ig n in g th e p h o t o c e ll w ith a 2 0 m m p a th le n g t h . D im e n s io n s : In s t r u m e n t : 5 ( W ) x 3 . 5 ( D ) x 1 6 .5 ( H ) c m ; ( 2 x 1 .4 x 6 . 3 7 5 in )
  7. 7. 7
  8. 8. eXact® Strip Micro AL - Part #486641 8
  9. 9. 9
  10. 10. Micro 10 Video – Total Alkalinity 10
  11. 11. eXact® Strip Micro pH - Part #486639 11
  12. 12. 12
  13. 13. Micro 10 Video - pH 13
  14. 14. eXact® Strip Micro CL (DPD-1) Part #486637 14
  15. 15. 15
  16. 16. Micro 10 Video – Free Chlorine 16
  17. 17. eXact® Strip Micro CL (DPD-3) Part #486638 17
  18. 18. 18
  19. 19. Micro 10 Video – Combined Chlorine 19
  20. 20. eXact® Strip Micro PO4 - Part #486814 20
  21. 21. 21
  22. 22. Micro 10 Video – Phosphate 22
  23. 23. eXact® Strip Micro CA - Part #486629 23
  24. 24. 24
  25. 25. Micro 10 Video – Calcium Hardness 25
  26. 26. eXact® Strip Micro CU - Part #486632 26
  27. 27. 27
  28. 28. Micro 10 Video – Copper 28
  29. 29. eXact® Strip Micro CH - Part #481657-II 29
  30. 30. 30 20:1 Dilution Method for Salt Test
  31. 31. Micro 10 Video – 20:1 Dilution Method 31
  32. 32. 32
  33. 33. Micro 10 Video – Chloride (Salt) 33
  34. 34. eXact® Reagent Micro CY-II Part #481652-II 34
  35. 35. 35
  36. 36. Micro 10 Video – Cyanuric Acid 36
  37. 37. eXact® Strip Micro HP - Part #486648 37
  38. 38. 38
  39. 39. 39
  40. 40. Micro 10 Video – Hydrogen Peroxide 40
  41. 41. Ready Snap® Verification Solutions 41
  42. 42. • Ampoule (solution) used to verify system (operator, reagent, and photometer) is performing correctly • Available for Total Alkalinity, pH, Calcium Hardness, Copper, Cyanuric Acid, Phosphate, and Salt, • No dilution needed, just snap ampoule open, fill cell with sample, and run test 42 P a r a m e t e r T e s tM e n u I t e m D e s i r e d V a l u e A c c e p t a b le R a n g e B o r d e r li n e R a n g e A L 1 T o t a l A lk a lin it y 5 2 p p m 4 2 - 6 2 3 8 - 6 7 P H 2 p H 7 . 5 p H 7 . 3 - 7 . 7 7 . 2 - 7 . 8 P O 4 P h o s p h a t e 2 p p m 1 . 7 - 2 . 3 1 . 6 - 2 . 4 C A 5 C a lc iu m a s C a C O 3 2 2 2 p p m 1 9 2 - 2 5 2 1 8 0 - 2 6 4 C Y 7 C y a n u r ic A c id 4 0 p p m 3 0 - 5 0 2 6 - 5 4 C U 8 C o p p e r a s C u + 2 0 . 2 2 p p m 0 . 1 7 - 0 . 2 7 0 . 1 4 - 0 . 3 0 C U 8 T o t a l C o p p e r a s C u + 2 0 . 6 4 p p m 0 . 5 6 - 0 . 7 2 p p m 0 . 5 3 - 0 . 7 5 p p m R051914 Assigned Value Chart for READY SNAP® 1P (lot 4813) Solution:
  43. 43. 43 P a r a m e t e r T e s tM e n u I t e m D e s i r e d V a l u e A c c e p t a b l e R a n g e B o r d e r l i n e R a n g e A L 1 T o t a l A lk a lin it y 5 2 p p m 4 2 - 6 2 3 8 - 6 7 P H 2 p H 7 .5 p H 7 . 3 - 7 . 7 7 .2 - 7 .8 P O 4 P h o s p h a t e 2 p p m 1 . 7 - 2 . 3 1 .6 - 2 .4 C A 5 C a lc iu m a s C a C O 3 2 2 2 p p m 1 9 2 - 2 5 2 1 8 0 - 2 6 4 C Y 7 C y a n u r ic A c id 4 0 p p m 3 0 - 5 0 2 6 - 5 4 C U 8 C o p p e r a s C u + 2 0 .2 2 p p m 0 .1 7 - 0 . 2 7 0 . 1 4 - 0 .3 0 C U 8 T o t a l C o p p e r a s C u + 2 0 .6 4 p p m 0 .5 6 - 0 .7 2 p p m 0 . 5 3 - 0 . 7 5 p p m R051914 Assigned Value Chart for READY SNAP® 1P (lot 4813) Solution: 1. Turn on the eXact® Micro three times with clean 2. test method procedure you want verified (for example 3. Snap® Verification Standard by twisting the top 180° (see Image 1 4 . S q u e e z e p la s t ic a m p o u le s e e Im a g e 2 5. sample followed with a quick shake of the meter to remaining water drops. 6. S q u e e z e p la s tic a m p o u le s e e Im a g e 2 7 . y o u d o n o r m a lly u s in g t h e c o r r e c t p r o c e d u r e ( s e e I m a g e 4 a n d r e f e r t o p h o t o m e t e r m a n u a l 8 . V a lu e c h a r t p r o v id e d b e lo w a n d o n b a c k ( s e e I m a g e 5 . 9 . I f y o u r v a lu e is w ith in t h e a r e o p e r a tin g th e e X a c t® f o r t h is M E N U t e s t m e th o d . 10. If your value is Borderline, review the Instruction Manual and verify that you are following the proper procedure. Step 1 through Step 8. 3 74 5 N O T E : CA5 test result was 220
  44. 44. Micro 10 Video – Ready Snap 1P 44
  45. 45. 45 eXact® Micro 10 for Poolside Testing U s e th e E Z - 3 ™ M e th o d ! FAST, ACCURATE RESULTS IN E Z - 3 ™ M e th o d
  46. 46. ITS ManufacturingITS Manufacturing • Manufacturing system based on Good Manufacturing Practices (GMP) • Temperature and humidity controlled environment • Quality Control laboratory • 3 Research and Development laboratories • Latest manufacturing and packaging equipment, with 2011 investment of $500,000 in new equipment • Currently adding 10,000 square feet of additional manufacturing space to complete Dec 2014 46
  47. 47. ITS Quality ControlITS Quality Control • Material is QC tested during filter paper impregnation and after final assembly • Testing is performed with water standards prepared with ACS grade chemicals and Industry Accepted procedures • Standards are verified by Industry Accepted method using colorimetric, titrimetric and gravimetric methods • All reagent strip lots are confirmed to be match listed specifications 47
  48. 48. Shelf LifeShelf Life • Accelerated Shelf Life Study –Product is placed in 55° C ovens for fixed times that simulate 6 month, 12 month, 18 month, 24 month, and 30 month product aging. The material is then tested for performance to estimate shelf life. • Real Time Shelf Life Study –Product is stored at room temperature and evaluated at six month intervals to confirm real shelf life. This study is repeated for every product at documented frequencies to update shelf life dating given to products 48
  49. 49. 49 eXact® Micro 10 Methodology for Poolside Testing www.sensafe.com / its@sensafe.com

×