Lampertz                                                                          www.lampertz.comLampertzWe plan and real...
Data CentresData centres made by LampertzRittal - Complete IT competence makes it possible“Online” around the clock with m...
System test    Forget simple component tests -    only system tested room constructions make your data centre secure! 1   ...
What does “system tested” mean?                                                                           “System-tested p...
Data CentresLampertz - We plan and realise data centres:No matter which topics interest you with regard to     Besides the...
Data centresHigh-availability solution for data centresIntelligent infrastructure solutions for every data centreYour secu...
Data CentresTailor-made investment security                                                                               ...
Data CentresBasic protection solutions for your Data CentreThe new Lampertz Efficiency Room                               ...
Data CentresSystem-tested room construction                                                                               ...
Outdoor data centre   Lampertz Outdoor Data Centre                                                                        ...
Outdoor data centreThe basic modules of the outdoor data centre                                                           ...
Mini data centreRACK PROTECTOR Modular Safe LMS 9.3Lampertz‘s mini datacentre - LMS 9.3The LMS 9.3 provides a complete sec...
Micro data centreRACK PROTECTOR Basic Safe LBS 9.1 C                                                                      ...
Lampertz                                                                                                                  ...
Upcoming SlideShare
Loading in …5
×

Rittal Data Center

1,303 views

Published on

Erdinç Klima

Published in: Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
1,303
On SlideShare
0
From Embeds
0
Number of Embeds
7
Actions
Shares
0
Downloads
37
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Rittal Data Center

  1. 1. Lampertz www.lampertz.comLampertzWe plan and realise efficient, secure as well as highly available Data Centres.
  2. 2. Data CentresData centres made by LampertzRittal - Complete IT competence makes it possible“Online” around the clock with maximum efficiency! Nowadays, there is a lot Comprehensive IT security – individually tailored!of discussion about the necessary optimisation of costs and business process- If we consider IT security from a holistic angle, it quickly becomes obviouses. Apart from the increase of efficiency in production and sales, optimisation that it extends far beyond purely logical and technical security. Apart fromis particularly focused on IT structures. Nowadays, information technology is firewalls, virus protection and storage concepts, effective protection of ITan essential differentiation feature in global competition. Anyone who is not structures against physical risks is immensely important. Irrespective of theyet “online” around the clock is simply not participating in globalisation and protection class required – from basic protection through to high-availabilityinstead gambles away such important competitive advantages on the local with absolutely minimum failure tolerances – demand-actuated IT security ismarket too. “state-of-the-art”.High-availability data centres are becoming increasingly important for critical This requires individual, but reliable and tested solutions, which adapt to thebusiness IT systems. In the age of globalisation, a 24 hour presence on the corporate structures - and not vice versa. Economic availability is thereforeinternet, of data and e-mails is an absolute must for many companies. The modular and flexible and for this reason can specifically deal with the indi-question, how long a company “wants to afford” failure of their IT structures vidual circumstances. It is also scalable so that it grows with the businesscan only be answered by the individual themselves, but the experts of Rittal, and above all it is comprehensive so that precisely the suitable protection isLampertz and LITCOS know how a company can make its systems highly available if a relevant risk should actually occur.available. Lampertz provides IT security rooms with a modular structure, including all technical infrastructure, to avoid ICT system downtimes and to optimally protect IT equipment - from basic protection through to high-availability protection. All security solutions can be flexibly adapted to the structural requirements. Secure – modular – scalable.
  3. 3. System test Forget simple component tests - only system tested room constructions make your data centre secure! 1 Criterion Standard Conventional LSR LER LER construction2 18.6 E Basic Extend System test Test as a complete system or construction according to the following standards X ✔ ✔ ✔ Fire protection ECB·S certification according to EN 1047-2, 50K temperature rise Test at temperatures of up and 85% rel. humidity over 24 hours (soak-out period), X ✔ X X to over 1000° C heating time 60 minutes 50K temperature rise and 85% rel. humidity over 30 minutes, without soak-out period X ✔ X ✔ F120 as system test according to EN 1363 (DIN 4102), for the design of the room units and their installation modules. X ✔ X X F90 as system test according to EN 1363 (DIN 4102), for the design of the room units and their installation modules. X ✔ ✔ ✔ F180 as component test only according to EN 1363 (DIN 4102), wall system only X ✔ X X F120 as component test only according to EN 1363 (DIN 4102), wall system only ( ✔) ✔ ✔ ✔ F90 as component test only according to EN 1363 (DIN 4102), wall system only ✔ ✔ ✔ ✔ Explosion Detonation test as system test of 200 kg TNT from 40 m distance X ✔ X X Water Standing water, 72 hours, 40 cm, 20 droplets maximum X ✔ X X Fire-fighting water, IP x6 as system test according to EN 605 29, for the design of the room units and their installation modules. X ✔ ✔ ✔ relative humidity, 85 %, over 24 hours (soak-out period), 60 minute heating time, in accordance with EN 1047-2 X ✔ X X relative humidity, 85 %, over 30 minutes X ✔ X ✔ IP 5x as system test according to EN 605 29, Dust tightness for the design of the room units and their installation modules X ✔+ ✔ ✔ Corrosive fire gases Fume/smoke (corrosive gas) tightness based on EN 1634-3 (DIN 18095) X ✔ X ✔ WK 3 as system test in accordance with EN 1627 / 1630, for the design of the room Unauthorised access units and their installation modules, e.g. doors X ✔ ✔ ✔ WK 2 as system test in accordance with EN 1627 / 1630, for the design of the room units and their installation modules, e.g. doors X ✔ ✔ ✔ WK 4 as component test only in accordance with EN 1627 / 1630, door system only X ✔ X X Debris loads Impact test as system test, 3 lateral impacts of 200 kg from 1.5 m height X ✔ X X Verified in accordance with tests on comparable components by EMC protection Aachen Technical University X ✔ ✔ ✔1 System-tested products are tested as a complete design or construction. This includes both the 2 The conventional construction method denotes room constructions made of RIGIPS (gypsum), room units and their installation modules such as doors, cable ducting or ventilation slides. Com- concrete and other commonly used building materials, which are unable to provide sufficient ponent tests on the other hand relate to individual parts only. security for data centre applications. In general, conventional construction methods are tested for use as a fire retardant wall.
  4. 4. What does “system tested” mean? “System-tested products are tested as a complete design or construction. This includes both the room units and all their installation modules such as doors, cable duct systems or ventilation slides. Only this system test certifies the security for the room structure or design and compliance with important security standards for the IT security room as a whole. The simple test of individual components is not very informative in business critical IT environments and is therefore ultimately not secure enough. Be- cause the component test only tests the protection class of the individual component. However, it cannot be used to provide any information whatso- ever about how the individual components together respond to threats, e.g. fire. These scenarios require a system test, in which it is precisely determined whether the overall construction of an IT security room or an IT security safe provides the required protection or not. Only the passed system test provides customers with adequate security - because it is “security at its best”!What is tested?Fire protection - fire test up to F180 ✓ Burglary protection - up to WK4 ✓according to DIN 4102-2 (EN1363) for design of the room units and their according to EN 1627 / EN 1630 for the design of the room units and theirinstallation modules such as doors, cable ducting and ventilation units. installation modulesDust protection - IP 5x ✓ Water / fire-fighting water protection - IPx6 ✓according to EN 605 29 for the design of the room units and their according to EN 605 29 for the design of the room units and theirinstallation modules. installation modules.4 Lampertz
  5. 5. Data CentresLampertz - We plan and realise data centres:No matter which topics interest you with regard to Besides the well known solutions and products The partnership factor:the planning and design, realisation or optimisa- Lampertz offers also a competent project coordi- Planning and consultationtion of your data centre, Lampertz is always your nation as service for your Data Centre - from a You define the requirements, we provide the solu-competent contact. We use modern and energy- single source and without interface problems. tion. Benefit from a strong and fair partnership.efficient infrastructure solutions for your specific Our competent consultation and planning teamair conditioning, energy and fire protection re- Whether you plan a new Data Centre, to increase with more than 40 design engineers covering allquirements. Lampertz stands for system-tested or optimize your existing Data Centre site, we as- aspects of data centre construction are availabledata centre solutions which satisfy every standard, sist you with our decades of experience as one of to you. Data centres, the most efficient air con-from basic protection through to high-availability the leading companies and as a trustful partner. ditioning concepts, cleverly devised energy sup-applications. ply systems as well as fire safety technology and monitoring concepts, are our passion - because it is “security at its best”!Intelligent infrastructure solutions for every data centreAnalysis, planning and management Air conditioning Power supply system Concept development Energy efficient air conditioning systems Power distributors Energy efficiency consultation Output controls Rittal modular UPS systems Planning of data centres Cold/hot aisle separation Emergency power systems (diesel generator) General contractorship Hot spot cooling CHP (Combined heat/power stations) Service and maintenance 365/24/7 Cold water units / chillers Fuel cell free cooling Secure network design Heat recovery Continuous surge suppressionData centre equipment Security Monitoring Rittal RimatriX5 Early fire detection systems Visualisation systems Server and network racks Fire alarm systems RiZone (Rittal management software) KVM switches Gas extinguishing/oxygen reduction systems Integration in the facility management Monitor / keyboard drawers Access control system Video surveillance Raised flooring systems Burglar alarm systems Alarm management Cabling routing systems Emergency plan Control stations Lampertz 5
  6. 6. Data centresHigh-availability solution for data centresIntelligent infrastructure solutions for every data centreYour security is our strength Modular, flexible, economicThanks to the modular kit system, our infrastructure solutions such as energy, Working in close dialog with our customers and partners, Lampertz developscooling, UPS and monitoring can be adjusted to the growing requirements of reliable infrastructure solutions to satisfy the high requirements of modernyour business at any time – especially for existing data centres with current data centres.need for optimisation. Single sourcing from one partnerAdvantages Specified system and network cabinets and precisely coordinated accessories Easy and flexible integration in existing building structures as an create a suitable room for structured accommodation of your IT components. overall concept or as individual modules Lasting, perfect air-conditioning is one of the greatest challenges for a data Modular design ensures future extension capability and long-lasting centre. Individual energy concepts, UPS systems, emergency electricity sup- economic efficiency ply solutions and preassembled wiring realise the optimum energy supply Demand-oriented design tailored to requirements in scalable and distribution within your data centre – even in an emergency. The raised protection classes flooring installation creates space for the wiring and the air-based general Consideration of company-wide security policy and economic aspects air conditioning. Short installation periods (even during system operation) Multi-stage early fire detection with active intake system and separate smoke System-tested solutions analysis provide additional safety and security, even during the incipient Efficient IT infrastructure solutions with low running costs growth phase of a fire. User-friendly and secure access control systems opti- High level of availability due to live monitoring and remote management mise comprehensive building management. State of the art video surveillance and other monitoring systems are deployed for continuous remote monitor- ing of the data centre. Easy and flexible integra- tion in existing building structures as an overall concept or in the form of individual modules6 Lampertz
  7. 7. Data CentresTailor-made investment security Lampertz LSR 18.6 E security room High-availability solution for data cen- tres and IT system sites. The LSR 18.6 E offers maximum secu- rity at any time for hardware systems, network components and servers - with certificate. Secure - modular - scalable.Modular structure LSR 18.6 E construction certifiedThe modular system structure of the LSR 18.6 E Complex 4-layer element core made ofenables this secure high-availability solution to thermally effective insulating substances ECB·S certification offers more thanbe both individually adjusted and extended at any Robust, encapsulated sheet steel component testingtime. cassette panels High-security door, ECB-S tested, As one of the few suppliers of complete dataProduct advantages: multi-point lock, WK 4 centres, Lampertz has had the LSR 18.6 E High-availability protection for data centres Patented connection system security room certified according to ECB·S. Extendable Additional fireproof floor elements Dis- and reassembly = investment security Use of extremely temperature and With this certification, the European Certifica- Reduced dust and noise installation moisture resistant seals tion Board (ECB·S) confirms that the LSR 18.6 E System-tested Use of air-conditioning/overpressure slides fulfils all criteria of the EN 1047-2 standard Multi-functional risk cover Dis- or reassembly is possible at any time without any reservations whatsoever, or even exceeds the requirements. Advantages of ECB·S certification for customers Maximum quality assurance due to independent quality inspection Improved rating situation for lending or residual risk insurance Transparency for banks and insurance companies Compliance with European IT security standards Modular extendability/ up-grading Product labelling for certified solutions Standard protection against: Fire Fire-fighting Corrosive Vandalism Unauthorised Electromagnetic Dust Explosion Debris loads Theft / burglary Mechanical Bullet-proof water gases access disturbance access Lampertz 7
  8. 8. Data CentresBasic protection solutions for your Data CentreThe new Lampertz Efficiency Room AdvantagesToday’s IT environments must be flexible, efficient and secure. Only modular Efficient value for moneyroom systems fulfil all these requirements and also offer fast and clean modi- n Optimum investment utilisation due to growing and modularfications and extensions. design of the whole data centre n Full investment protection due to complete dis- and reassemblyLampertz Efficiency Rooms (LER) provide uncompromising of the security roomflexibility and extremely short delivery times. Efficient designSystem tests are “state-of-the-art”. Why should you as a customer be satis- n Optimum space utilisation of the structural circumstancesfied with less security, flexibility and long-term benefits? Only the system n Fast ínstallationtest of a room construction certifies the necessary high security level for IT n Ideal for engineering and infrastructure roomssystems and data. n Environmentally friendly manufacturing methods Efficient project completion n Extremely short delivery times (for basic version = 10 working days) n Tailor-made data centre solution due to flexible modular principle n Flexibly self-assembly with supervisor Efficient air conditioning concepts n Optimum air routing, e.g. cold / hot aisle housing n Economic air conditioning System-tested basic protection n Compliance with current EN and DIN standards n Multifunctional risk cover (fire, water, burglary, ....)One modular kit – endless possibilities Options packagesThe heart of the new Lampertz efficiency rooms is the modular principle. The The customer’s requirements are focussed on security, efficiency and avail-basic package already contains solid basic equipment and features and can ability. The LER options packages contain, among other things, solutions forbe adjusted to a customer’s individual requirements by adding various op- security, systems engineering, air conditioning, energy distribution or moni-tional modules and components. toring. With these diverse options, IT managers can tailor a precisely-fitting and secure IT made-to-measures suit. Access control Cable duct Air-conditioning Power supply system system systems Figure with options Fire detection/fire Floor system Full assembly and Lighting systems extinguishing installation Basic package Modular room construction, security functions, door system, Monitoring Project mana- Optical package Data and network cable ducts, delivery and installation supervisor gement systems Standard protection against: Fire Fire-fighting Corrosive Vandalism Unauthorised Electromagnetic Dust Debris loads Theft / burglary water gases access interferance8 Lampertz
  9. 9. Data CentresSystem-tested room construction Lampertz Efficiency Room Modular, secure data centres for basic protection and extended basic protection. System tested room construction with sheet steel cassette panel construction method both for complete data centres, as well as for walls and ceilings. LER BasicLER Basic LER ExtendLampertz Efficiency Room Basic: Lampertz Efficiency Room Extend:Modular, secure data centre for basic protection Modular, secure data centre for extended basicstandards. protection. Note: A system test means testing a com- plete room construction including its builtConstruction of the LER Basic: Construction of the LER Extend: in modules such as doors, cable ducts andn Fire and heat-retardant element core, n Fire and heat-retardant element core, ventilation slides: Component tests are not consisting of a thermally effective consisting of a thermally effective very informative when applied to complete insulating substance insulating substance data centres and server rooms!n Robust sheet steel sandwich elements n Robust sheet steel sandwich elementsn Innovative element connection through n Innovative element connection through stable zinced profile technology stable zinced profile technology Your special additionaln Security door, F90, up to WK 3 n Security door with additional fireproof benefits:n Use of fire protection flaps insulation, F90, up to WK 3n Dis- and reassembly possible at any time n Special floor seal The Lampertz efficiency room generation is the first and only data centre design on the n Use of temperature and moisture market for basic protection solutions, which resistant seals is system-tested to European standards. n Use of air-conditioning slides n Dis- and reassembly possible at any time Fire protection: EN 1363 (DIN 4102) Unauthorised access: EN 1627 Watertightness: EN 6 05 29 Dust tightness: EN 6 05 29Example of use - infrastructure room:The Lampertz efficiency rooms, LER Basic and LER The two room systems are connected with eachExtend, are optimally suitable for use as an engi- other using modular elements. Due to this design,neering room for the infrastructure components of the Lampertz efficiency room also has an air locka data centre. The air conditioning and power sup- function.ply systems are equipped with basic security. Thesensitive active components, e.g. servers, are ide-ally stored in a high-availability room (LSR 18.6 E)with this design option. LER Extend Lampertz 9
  10. 10. Outdoor data centre Lampertz Outdoor Data Centre The outdoor data centre is ready for use on site - worldwide - within a very short time. Figure shows Model L20D The Lampertz outdoor data centre has been especially developed for tempo- Your advantages rary use of IT systems. It is an energy-efficient and quickly available solution for the accommodation of IT hardware and 19” racks and is available, ready n Mobility for installation in a very short time. Can be positioned on any site, indoor or outdoor, which is suitable for instal- lation of a container. It is possible to change the location at any time. The connection of a container with features such as free cooling air condition- ing, extinguishing system, integrated electricity and back-up power supply. n Energy efficiency This overall package offers secure use with optimised running costs. Air conditioning by means of free cooling technology can save up to 40 % of cooling costs compared to conventional air conditioning units. The outdoor data centre is especially suitable for companies who would like to use the Lampertz outdoor data centre to bridge the time while their exist- n Plug & Play solution ing data centre is being altered or extended, still ensuring availability and The Lampertz outdoor data centre is delivered ready for use: security. The outdoor data centre can also be used as an independent main Install – Plug and wire - Ready! or back-up data centre. n Availability 6000 The IT container is ready for use on site - worldwide - within a very 5800 short time. Klima 400/740 n Individuality The Lampertz outdoor data centre is available with Rittal TS8 quality racks Lösch Strom Rack Rack Rack Rack Rack USV Klima 600/1000 600/1000 600/1000 600/1000 600/1000 600/1000 (basic version not equipped with racks). It is also possible to use a customer’s 23002500 existing 19” racks. 400/600 300/600 400/740 1 2 3 4 5 Klima 400/740 n Protection properties The place of use can be chosen regardless of the weather. The outdoor data centre defies the rain, wind, heat and cold and other weather conditions. 100 100 600 Example: L20D option 1000 n Monitoring Whether with Rittal’s computer multi control (CMC) monitoring or an existing system - our customers have full control and an overview of their IT infra- structures at all times. n Environmental awareness Environmentally friendly materials and technologies are used. This also ap- plies to the use of non-toxic extinguishing agents. n Install – Plug and Wire - Ready! 10 Lampertz
  11. 11. Outdoor data centreThe basic modules of the outdoor data centre Lampertz Outdoor Data Centre The basic version of the outdoor data centre is already a completely functional system. Scope of supply of the basic model: ✓ IT container ✓ Air conditioning ✓ Power distribution ✓ Raised floor ✓ Cable ducts ✓ Access control systemContainer: Power distribution: The optional modulesSteel frame with corrugated sheet facade “made The scope of supply includes the interior lighting,in Germany” as self-supporting steel frame struc- a working socket, seven fused outputs for the UPSture in various RAL colours (standard colour RAL power supply to the racks, power supply for the Accommodation of the energy3020 red). Walls, ceiling and floors F30 protection infrastructure components and a multi-meter for efficient UPS in a rack.classification. monitoring current intensity and voltage. Extinguishing systemDimensions: Duct: Fully automatic fire alarm and extin- External (D x W x H): 6055 x 2435 x 3000 mm Two hard ducts are available for the power supply guishing system incl. early fire detection. Internal (D x W x H): 5727 x 2270 x 2700 mm and a for the data wiring (two further ducts canUsable area: 13 m2 be optionally integrated). 19” rack systemWeight: approx. 3.5 tonnes Depending on the model, up toFloor load: 3500 N/sqm Access system: seven 19” racks can be integrated. The door corresponds to resistance class WK 2.Raised flooring: Power distribution (to/within)300 mm high raised flooring is integrated for air the rackrouting and cable management. Plug & Play power distribution packages available.Air conditioning: 7 kW 1+1 redundant = approx. 2.000 Euro* Access systemThe free cooling technology air conditioning is 14 kW 2+1 redundant = approx. 3.800 Euro* Alternatively, other access systemsclassified into three capacity levels: 20 kW 2+1 redundant = approx. 4.600 Euro* can be used.*Savings per year compared to a conventional air conditioning solution and based on an electricity price of 0.095 euro/kWh. Monitoring The computer multi control CMC-TC monitors the technical components and sends error messages.. Colours The Lampertz outdoor data centre is available in different RAL colours. Cable duct Two additional cable ducts (hard ducts) are also available. Sun protection Solar protection is available for outdoor installation. Service/Maintenance The service includes one maintenance inspection per year. Lampertz 11
  12. 12. Mini data centreRACK PROTECTOR Modular Safe LMS 9.3Lampertz‘s mini datacentre - LMS 9.3The LMS 9.3 provides a complete securityarea for one or several 19” racks. The modularsafe is equipped with individually selectable The data centre for small andair conditioning. An uninterruptible power medium-sized enterprisessupply, monitoring system and fire alarm andextinguishing system can be integrated in theLMS 9.3. All safes without contents/decorationsLMS 9.3 42 HE 47 HE The basic models are equipped as follows: The advantages:Outer dimensions Modular housing construction Extended basic protection for your system Extendable linkage possible on the left securityHeight 2210 2410 and right Protection against potential physical threatsWidth 1100 1100 Operator and service door such as fire, water, smoke...Depth 1 1200/1400 1200/1400 Tested cable entry systems in both side walls Modular, flexible, extendableDepth 2 1520/1720 1520/1720 Prepared for compact air conditioning Individual air conditioning concept up Key lock with 2 keys to 28 kWInner dimensions Installation during IT system operation without Available as: any negative effects on the workflow, i.e.Height 2030 2230 42 HE or 47 HE without IT downtimeWidth 920 920 as a single safe or as 2, 3 or 4 module linkageDepth 1000/1200 1000/1200 (single safe can be extended at any time as linkage)Total weight 3 ≈ 760 kg ≈ 800 kg Internal depth 1000 mm or 1200 mm 1 closed doors without air conditioning unit 2 with air conditioning unit 3 without interior equipment All dimensions in mm. Colour: Light grey, RAL 7035 Operator door RAL 3020 (traffic red). Alternative colours available on request.Passive interior monitoring: Complete physical protection of network and hardware components. The Lampertz LMS 9.3 modular safe provides physical protection with a high level of security. Tested according to DIN 4102. Fire protection F 90 and compliance with the limit values ∆T <50 K and relative humidity <85% over 30 minutes. Burglary protection WK 2 / optional burglary protection WK 3 or WK 4. Dust protection and protection against high-pressure sprayed water: IP56. The tests have been performed as a system test and are verified by test reports. Standard protection against: Optional equipment Early fire detection system EFD Very early smoke detection in 19“ technology Fire Fire-fighting Corrosive Unauthorised Vandalism Debris loads Dust water gases access12 Lampertz
  13. 13. Micro data centreRACK PROTECTOR Basic Safe LBS 9.1 C Lampertz’s micro data centre - LBS 9.1 C With the Lampertz Basic Safe LBS 9.1 C, Lampertz presents the smallest air condi- The smallest air conditioned tioned data centre in the world. This provides data centre in the world smaller companies with a cost-effective op- tion for protecting individual 19” or stand- alone servers. All safes without contents/decorationsThe new compact Lampertz Basic Safe LBS 9.1 C Description of the standards LBS 9.1 C 1.3 kW air conditioning(“Compact”) with a useful height of 15 height Security housing with two door system Internal depth 800units (15 HU) provides equipment flexibility. Ap- Cable entry in both side elements Dimensions (inside) 827 x 620 x 824propriate IT protection is therefore now available 1.3 kW / 2.4 kW air conditioningfor small and medium-sized enterprises too. Usable internal height 15 HU Outer dimensions 1646 x 806 x 1119 Weight with Air-con approx. 299 kgAs a standard, the Basic Safe Compact is equipped Optional equipmentwith a tested cable entry in each side wall and Fire detection and extinguishing system - Internal depth 1000with 1.3 or 2.4 kW air conditioning. DET-AC Plus Dimensions (inside) 827 x 620 x 1024 Early fire detection system – EFD Plus Outer dimensions 1646 x 806 x 1319 Monitoring – CMC-TC Weight with Air-con approx. 330 kg Uninterruptible power supply – PMC 12 19” network rack LBS 9.1 C 2,4 kW air conditioning Applications and advantages Internal depth 800 Micro data centre for small and medium Dimensions (inside) 827 x 620 x 824 enterprises Outer dimensions 1699 x 806 x 1119 Protection for servers, storage applications, ... Weight with Air-con approx. 319 kg Also integrable in smaller offices Storage of personal data, e.g. in doctor’s Internal depth 1000 practices or tax consultancy firms Dimensions (inside) 827 x 620 x 1024 Outer dimensions 1699 x 806 x 1319Colour: Weight with Air-con approx. 360 kg All versions with two doors and accessible base.Light grey, RAL 7035 Operator door RAL 3020 (traffic red). Alternative colours available on request. All dimensions in mm.Fire and access-protected storage of network and hardware components. Active protective measures:Basic safe Fire protection F90 in accordance with DIN 4102. Compliance with the limit values ∆T < 50 K,relative humidity < 85% over 10 minutes. Access protection. Burglary protection WK 2.The tests have been performed as a system test and are verified by test reports. Standard protection against: Optional equipment Fire-detection and extinguishing system Fire Unauthorised Vandalism Theft, burglary (DET-AC Plus) access Lampertz 13
  14. 14. Lampertz www.lampertz.comReferencesNew data centre: modern technology ensures energy efficiency „Energy management with future – abilis opts for Green IT in its new building“TRUMPF, with its head office in Ditzingen, is a technology firm focusing on production Knowledge of the mechanical engineering and process integration industry and a com-and medical engineering. prehensive, integrated range of services characterise the profile of abilis.The new data centre in the company’s central location in Ditzingen is 150 m² in total andas such is designed for the IT tasks of the next few years. 105 m² alone are used for the “The abilis data centre is the ideal example of a data centre suitable for a medium-sizedcertified high-availability room LSR 18.6 E. The redundant and therefore failsafe design company and with focus on applications for mechanical engineering companies who doof energy distribution and air conditioning ensures functioning data delivery at all times. their own research and development, production and IT – abilis is therefore a partnerThe computing systems for the development, production and infrastructure are operated on an equal footing as its customers”, said Schäfer, emphasising the purpose of the newin the data centre itself. This includes the data storage as well as applications for plan- data centre. An ideal abilis customer is in the mechanical engineering industry, has approx.ning, design, file services and communication. Modern Rittal racks were installed to take 100-200 employees and is planning or already uses an SAP system.into account the performance, failsafe and energy efficiency requirements as well as theneed for user friendliness. abilis provides these customers a data centre planned, built and ECB·S certified by Lampertz with an area of 60 m² and state of the art infrastructure solutions such as fireLampertz contributed to the success of the project by providing the concept, construc- protection (at least 180 minutes), active early fire detection, Novec extinguishing system,tion and installation of the engineering and security room from a single source in only redundant air conditioning and power supply and even a separate backup data centre ofseven weeks. 30 m² for security reasons. 110095100021 · 2.5 · 03/09 · ha · Printed in GermanyLampertz GmbH & Co. KGIndustriestraße 24D-56472 Hof/GermanyPhone +49(0)26 61 9 52-0 E-Mail: info@lampertz.comFax +49(0)26 61 9 52-99 www.lampertz.com

×