Integrated building systems measures & evaluation

  1. 1. Cairo university faculty of engineering department of architecture masters studies 2004 Integrated building systems measures & evaluation Case study arcadia mall & residential complex
  2. 2. Cairo university faculty of engineering department of architecture masters studies 2004 Contents : Project Data Sheet & contents Project electro mechanical system HVAC System Theoretical approach Case study Fire fighting System Theoretical approach Case study Fire safety Fire alarm System
  3. 3. Cairo university faculty of engineering department of architecture masters studies 2004 Arcadia project: •Residential sector covering 8 floors height •Seven floors for commercial uses covers 53,000m2 •Food court consisting of 14 fast food outlets •Four cinemas with 400 seats each ( now used as fun planet ) •Ice skating arena 140m2 on the ground floor ( now used as a cafeteria ) •Parking area of 20,000 m2 with a 600 cars capacity •Data Fact : Location: cornice el Nile Client : al Ahly real Estate Development Consultant : Sabbour Associates Architects : afzxfzdfzs 4- Parking Sector •Project Contents: •Thee panoramic elevators from parking level to all levels •Atrium area 300m2 on the 1st level then it enlarges up to 660 m2 at the 7th level 1 2 3 4 3- Fun planet & office Sector 2- Commercial Sector 1- Residential Sector
  4. 4. Cairo university faculty of engineering department of architecture masters studies 2004 Arcadia project: •Heating , ventilation & air –conditioning •Smoke pressurization system •Fire protection systems •Vertical transportation systems (elevators & escalators ) •Drinking water booster system •Emergency stand – by diesel generating sets •Fuel supply system •Dewatering & waste pumping sets •Plumping & drainage systems •Telephone & intercom. Systems •Fire alarm system •TV & satellite system •Electrical systems •Electro – Mechanical Systems 1 2 3 4 3 555 6 77 8 1. Mall main ent. 2. Mall sec ent 3. Residential ent. 4. E. stairs & service zone 5. Residential core 6. F.F tanks 7. Machine room 8. HVAC room 5
  5. 5. Cairo university faculty of engineering department of architecture masters studies 2004 H.V.A.C SYSTEM •Heat sorce •Theoretical Introduction: •Comfort zone •Building outerconditions
  6. 6. Cairo university faculty of engineering department of architecture masters studies 2004 H.V.A.C SYSTEM •Heat lose cases •Theoretical Introduction: •Insulation system •AC cycle •Types of grills
  7. 7. Cairo university faculty of engineering department of architecture masters studies 2004 •Riser diagram •Water cooling system h.v.a.c system 1 425 3 1. Primacy pump (P.P) CAP.2400 GPM 60 HP 2. Secondary Pump zone1(P.S-1) CAP.2600 GMP 150 HP 3. Booster Pump zone1 (B.P-1) CAP ……. 50HP 4. Secondary pump zone2 (P.S-2) CAP. 2200 GPM 125 HP 5. Booster pump zone2 (B.P-2) CAP …….. 40HP •Zone 2 •Zone 1 •Closed water cycle.
  8. 8. Cairo university faculty of engineering department of architecture masters studies 2004 H.V.A.C SYSTEM 1. Round doors in the entrances 2. AHU in the atrium 3. AC grills in corridors 4. AHU in the a shop 5. Upright AHU in food court 6. AC grills in the computer center 7. AC ducts in basement 8. AC ducts in basement 2 3 7 4 5 6 8 1
  9. 9. Cairo university faculty of engineering department of architecture masters studies 2004 Fire fighting system •Smoke movement & control •Theoretical Introduction: •Mechanism of smoke production •Smoke control in fire area
  10. 10. Cairo university faculty of engineering department of architecture masters studies 2004 Fire fighting system •Theoretical Introduction: •Smoke control in escape routes
  11. 11. Cairo university faculty of engineering department of architecture masters studies 2004 •Riser diagram •Hazard Zones 2 3 4 5 6 1. Mall main ent. 2. Mall sec ent 3. Residential ent. 4. E. stairs & service zone 5. Residential core 6. F.F tanks 7. Machine room 8. HVAC room Open spray spr. & deluge system Atrium Zone 7 Combined sprinkler system Commercial Zone Combined sprinkler system Parking Zone Clean approved agent system Control Zone C02 auto firef system Electrical Zone High exp Foam System Diesel generators 6 Wet stand pipe system Residential Zone 1 7 2 1 Fire fighting system
  12. 12. Cairo university faculty of engineering department of architecture masters studies 2004 •According to NFPA For any leakage or pressure drop the jokey pump intiates the system •If pressure drops excees limitation the 2 main pump works together •The 2 pumps have to be of different energy sources •System Structure … 1. Sub header 1 to residential 2. Sub header 2 to commercial & parking 3. To foam- water system 4. Main header Fdc max distance from system is 18m Used to enable fd connects to the ff system externally Fire department connection 2 1 Fire fighting system 3 50 GPM sec F.F. pump starts at small pressure dec. or sprinklers leakage Jockey pump 3000 gallon capacity for 90 min Double cell help in maintenance Double cell water tank 4 1500 GPM main F.F. pump Electrical pump 1500 GPM main F.F. pump Diesel pump •Pump & tank room in basement
  13. 13. Cairo university faculty of engineering department of architecture masters studies 2004 •The sub header 1 splits into 4 risers to cover each of the residential cores found in the complex •The system covers the corridors only •Each riser contains 14 hose reel cabinets •System Structure … 1. Sub header 1 to residential 2. Riser for each zone 3. FDC 4. HRC hose reel cabinet 2 1 Fire fighting system 3 4 •Residential section
  14. 14. Cairo university faculty of engineering department of architecture masters studies 2004 •The depressurized pipes enables quick & powerful water injection •The open sp. Act as water curtains to prevent smoke spread •The system is called the deluge system •Infrared detectors are the only detectors having the ability to initiate the system •Mechanical windows acts as smoke vents •System Structure … 1. Sub header 1 to residential 2. Sub header 2 to commercial & parking 3. FDC 4. Depressurized pipes 2 1 Fire fighting system 4 3 •Atrium zone
  15. 15. Cairo university faculty of engineering department of architecture masters studies 2004 •The system is combined with heat & smoke detectors •The blank off is used for future expansion •System Structure … 1. Sub header 1 to residential 2. Sub header 2 to commercial & parking 3. FDC 4. Risers for zone 5. Sprinklers controllers 2 1 Fire fighting system 4 3 •Upright sprink. •Commercial & parking zone 5
  16. 16. Cairo university faculty of engineering department of architecture masters studies 2004 •Commercial examples … 1. Sub header 1 to residential 2. Sub header 2 to commercial & parking 3. FDC 4. Risers for zone 5. Sprinklers controllers Fire fighting system •Upright sprink. •Commercial & parking zone • example for used sprinkles in different spaces in the mall. And other shops doesn’t have any fire fighting system.
  17. 17. Cairo university faculty of engineering department of architecture masters studies 2004 •Using stair pressurization system to keep smoke out of the staircase •The fan power is calculated depending on no of doors •Staircase … 1. Residential em. Exits 2. Mall em. Exits 3. Panoramic elevators 4. Office em. exit 2 1 Fire safety system 4 3 11 1 •Escalators … •Downward escalators are only used for fire escape and it has side water curtains for human safety from fire. •Elevators … •All elevators go to ground level incase of any fire or other emergency •Corridors… • In corridors They use coned shaped lighting and escape signs • only used fire escape staircase
  18. 18. Cairo university faculty of engineering department of architecture masters studies 2004 •The mall has an alarm system that avoids false alarm and makes the following actions: • detect the fire in the first stages by the detectors (smoke , infrared and heat detectors) and the place is shown on the info board. • when fire is detected the info board acts the following actions:  send messages for the alarm for the building  send messages for the A.H.U to stop to avoid fire spreading.  send messages for elevators •Fire alarm… Fire alarm system  send messages for smoke duct system • the main info board works to be sure that the fire fighting system is working and safety system. • it also is responsible of fighting fire by different agents in different spaces such as mechanical . Electrical room and elevators. • the building contains emergency speaker system. • the building contains an automatic emergency caller. •speakers •Smoke duct. •Deluge detector •detector •Alarm. •The alarm system is an automatic one but also can be used as a manual one in emergency cases

×