Successfully reported this slideshow.
We use your LinkedIn profile and activity data to personalize ads and to show you more relevant ads. You can change your ad preferences anytime.

SIstem Tata Udara dan Refrigerasi pada Ruang Fitness Kapal Tanker 17500 DWT

332 views

Published on

Published in: Engineering
  • Be the first to comment

  • Be the first to like this

SIstem Tata Udara dan Refrigerasi pada Ruang Fitness Kapal Tanker 17500 DWT

  1. 1. COOLING LOAD and DUCTING SYSTEM  HANDIKA SEMBIRING  SAIFUL HABIB  MADITSA ARIZAL
  2. 2. I. Luas area II. Cooling load III. CFM dan ducting
  3. 3. I. Luas area 1. Quite library room 2. Mess room 3. Day room 1 4. Day room 2 5. TV room 6. Film room
  4. 4. Quite library room
  5. 5. Mess room
  6. 6. Day room 1
  7. 7. Day room 2
  8. 8. TV room
  9. 9. Film room
  10. 10. II. Cooling load
  11. 11. quite library room
  12. 12. Con’t Internal heat
  13. 13. Mess Room ukuran ruangan t 7.26 p 17.82 l 12.1 outdoor temperatur indoor temperature selisih dry bulb 95° F dry bulb 82° F dry bulb 13 humidity 58% humidity 40% humidity 18% wet bub 82° F wet bulb 65° F wet bulb 17 kandungan uap air 146 kandungan uap air 66 kandungan uap air 80 suhu ruangan yang diinginkan 23.88889 75° F Item Area (ft2) ∆T Factor total Wall (sisi kiri) 47.674 6.2 0.2293578 67.79330275 Wall (sisi kanan) 26.62 17 0.14792899 66.94378698 Wall (sisi depan) 39.204 0 0.23310023 0 Wall (sisi belakang) 49.368 3 0.23310023 34.52307692 langit-langit 52.9613333 3 0 0.46511628 0 lantai 52.9613333 3 0 0.62111801 0 total panas material 134.7370897 Internal heat item jumlah daya People 8 light 4 30 Televisi 1 100 kulkas 1 150 Sensible rooom sensible heat 3512.96533 safety Factror 2% 70.2593066 total sensible heat+safety factor 3583.224636 Laten room latent heat 1385.793076 safety factor 2% 27.71586152 total laten heat+safety factor 1413.508937 supply duct heat gain 5,7% 204.2438043 Supply duct leakage 2% 71.66449273 fan horsepower 2,3% 82.41416664 cooling load 5355.056037btu/hr
  14. 14. Mess Room kostruksi dinding luar (sisi kanan) U= 0.147928994 konstruksi dinding depan dan belakang U= 0.233100233 konstruksi sisi kiri U= 0.229357798 konstruksi langit-langit U= 0.465116279 Konstruksi lantai U= 0.621118012 Rincian  Dindingkanan 1 mild steel + air space + mild steel 1/2" + rookwoo + plywood 1/2"  Dindnigdepanbelakang 1 𝑝𝑙𝑦𝑤𝑜𝑜𝑑 1/2" + 𝑟𝑜𝑜𝑘𝑤𝑜𝑜𝑙 + 𝑝𝑙𝑦𝑤𝑜𝑜𝑑 1/2 "  Dindingkiri 1 𝑚𝑖𝑙𝑑 𝑠𝑡𝑒𝑒𝑙 1/2" + 𝑟𝑜𝑜𝑘𝑤𝑜𝑜𝑙 + 𝑝𝑙𝑦𝑤𝑜𝑜𝑑 1/2"  Langit-langit 1 𝑔𝑦𝑝𝑠𝑢𝑚 + 𝑎𝑖𝑟 𝑠𝑝𝑎𝑐𝑒 + 𝑚𝑖𝑙𝑑 𝑠𝑡𝑒𝑒𝑙 1/2"  Lantai 1 ℎ𝑎𝑟𝑑𝑤𝑜𝑜𝑑 + 𝑚𝑖𝑙𝑑 𝑠𝑡𝑒𝑒𝑙 1/2" bahan faktor/inch mild steel 1.4 plywood 1/2" 0.63 rookwool 3.03 mild steel 1/2" 0.7 air space 1 hardwood 0.91 gypsum 0.45
  15. 15. Mess Room aktivitas di mess room,seated at rest sensible 230btu/hr latent 120btu/hr total 350btu/hr kalor dari orang sensible 1840btu/hr latent 960btu/hr total 2800btu/hr menghitung jumlah watt dari cahaya lampu light 120watt menghitung beban panas dari lampu light 408btu/hr panas di sekitar lampu 25% 102btu/hr total panas lampu 510btu/hr Menghitung panas dari televisi Televisi 100watt panas dari tv 340btu/hr kulkas 150watt panas dari kulkas 510btu/hr total panas sensible 3200btu/hr laten 960btu/hr infiltration volume ruangan 1565.41572 air changes rate 0.3 waktu 60second kebutuhan cfm per orang 15 air flow 7.8270786cfm kebutuhan cfm per orang 120 total cfm 127.8270786 sensible infiltration 143.7051631 laten infiltration 425.7930758 friction loss 2.3 diameter duct 3.25inch 8.125 luas pipa 8.2915625square inch 81.25
  16. 16. Day Room 1 outdoor temperatur indoor temperature selisih dry bulb 95° F dry bulb 82° F dry bulb 13° F humidity 58% humidity 40% humidity 18% wet bub 82° F wet bulb 65° F wet bulb 17° F kandungan uap air 146 kandungan uap air 66 kandungan uap air 80 suhu ruangan yang diinginkan 25.55556 78° F Item Area (ft2) ∆T Factor total Wall (sisi kiri) 49.368 6.2 0.2293578 70.20220183 Wall (sisi kanan) 49.368 17 0.14792899 124.1502959 Wall (sisi depan) 24.684 3 0.23310023 17.26153846 Wall (sisi belakang) 24.684 0 0.23310023 0 langit-langit 76.296 0 0.46511628 0 lantai 76.296 0 0.62111801 0 total panas material 211.6140362 Internal heat item jumlah daya People 12 light 5 30 Televisi 1 100 kulkas 1 150 hand dryer 1 50 ukuran ruangan t 7.26 p 22.44 l 11.22 Sensible rooom sensible heat 3512.96533 safety Factror 2% 70.2593066 total sensible heat+safety factor 3583.224636Laten room latent heat 1385.793076 safety factor 2% 27.71586152 total laten heat+safety factor 1413.508937supply duct heat gain 5,7% 204.2438043 Supply duct leakage 2% 71.66449273 fan horsepower 2,3% 82.41416664 cooling load 5355.056037btu/hr
  17. 17. Day Room 1 Rincian  Dindingkanan 1 mild steel + air space + mild steel 1/2" + rookwool + plywood 1/2"  Dindnigdepanbelakang 1 𝑝𝑙𝑦𝑤𝑜𝑜𝑑 1/2" + 𝑟𝑜𝑜𝑘𝑤𝑜𝑜𝑙 + 𝑝𝑙𝑦𝑤𝑜𝑜𝑑 1/2 "  Dindingkiri 1 𝑚𝑖𝑙𝑑 𝑠𝑡𝑒𝑒𝑙 1/2" + 𝑟𝑜𝑜𝑘𝑤𝑜𝑜𝑙 + 𝑝𝑙𝑦𝑤𝑜𝑜𝑑 1/2"  Langit-langit 1 𝑔𝑦𝑝𝑠𝑢𝑚 + 𝑎𝑖𝑟 𝑠𝑝𝑎𝑐𝑒 + 𝑚𝑖𝑙𝑑 𝑠𝑡𝑒𝑒𝑙 1/2"  Lantai 1 ℎ𝑎𝑟𝑑𝑤𝑜𝑜𝑑 + 𝑚𝑖𝑙𝑑 𝑠𝑡𝑒𝑒𝑙 1/2" bahan faktor/inch mild steel 1.4 plywood 1/2" 0.63 rookwool 3.03 mild steel 1/2" 0.7 air space 1 hardwood 0.91 gypsum 0.45 kostruksi dinding luar (sisi kanan) U= 0.147928994 konstruksi dinding depan dan belakang U= 0.233100233 konstruksi sisi kiri U= 0.229357798 konstruksi langit-langit U= 0.465116279 Konstruksi lantai U= 0.621118012
  18. 18. Day Room 1 aktivitas di ruang makan 1 sensible 240btu/hr latent 310btu/hr total 550btu/hr jumlah orang dengan kalor sensible 2880btu/hr latent 3720btu/hr total 6600btu/hr menghitung jumlah watt dari cahaya lampu light 150watt menghitung beban panas dari lampu light 510btu/hr panas di sekitar lampu 25% 127.5btu/hr total panas lampu 637.5btu/hr Menghitung panas dari televisi Televisi 100watt panas dari tv 340btu/hr kulkas 200watt panas dari kulkas 680btu/hr hand dryer 50watt panas dari hand dryer 170btu/hr total panas sensible 4707.5 laten 3720 infiltration volume ruangan 1827.899568 air changes rate 0.3 waktu 60second kebutuhan cfm per orang 15 air flow 9.13949784cfm kebutuhan cfm per orang 180 total cfm 189.1394978cfm sensible infiltration 167.8011803 laten infiltration 497.1886825 friction loss 1.7 diameter duct 4inch luas pipa 12.56square inch
  19. 19. Day Room 2 outdoor temperatur indoor temperature selisih dry bulb 95° F dry bulb 82° F dry bulb 13° F humidity 58% humidity 40% humidity 18% wet bub 82° F wet bulb 65° F wet bulb 17° F kandungan uap air 146 kandungan uap air 66 kandungan uap air 80 suhu ruangan yang diinginkan 25.55556 78° F Item Area (ft2) ∆T Factor total Wall (sisi kiri) 49.368 6.2 0.2293578 70.20220183 Wall (sisi kanan) 49.368 17 0.14792899 124.1502959 Wall (sisi depan) 24.684 3 0.23310023 17.26153846 Wall (sisi belakang) 24.684 0 0.23310023 0 langit-langit 76.296 0 0.46511628 0 lantai 76.296 0 0.62111801 0 total panas material 211.6140362 Internal heat item jumlah daya People 12 light 5 30 Televisi 1 100 kulkas 1 150 hand dryer 1 50 ukuran ruangan t 7.26 p 22.44 l 11.22 Sensible rooom sensible heat 3512.96533 safety Factror 2% 70.2593066 total sensible heat+safety factor 3583.224636Laten room latent heat 1385.793076 safety factor 2% 27.71586152 total laten heat+safety factor 1413.508937supply duct heat gain 5,7% 204.2438043 Supply duct leakage 2% 71.66449273 fan horsepower 2,3% 82.41416664 cooling load 5355.056037btu/hr
  20. 20. Day Room 2 Rincian  Dindingkanan 1 mild steel + air space + mild steel 1/2" + rookwool + plywood 1/2"  Dindnigdepanbelakang 1 𝑝𝑙𝑦𝑤𝑜𝑜𝑑 1/2" + 𝑟𝑜𝑜𝑘𝑤𝑜𝑜𝑙 + 𝑝𝑙𝑦𝑤𝑜𝑜𝑑 1/2 "  Dindingkiri 1 𝑚𝑖𝑙𝑑 𝑠𝑡𝑒𝑒𝑙 1/2" + 𝑟𝑜𝑜𝑘𝑤𝑜𝑜𝑙 + 𝑝𝑙𝑦𝑤𝑜𝑜𝑑 1/2"  Langit-langit 1 𝑔𝑦𝑝𝑠𝑢𝑚 + 𝑎𝑖𝑟 𝑠𝑝𝑎𝑐𝑒 + 𝑚𝑖𝑙𝑑 𝑠𝑡𝑒𝑒𝑙 1/2"  Lantai 1 ℎ𝑎𝑟𝑑𝑤𝑜𝑜𝑑 + 𝑚𝑖𝑙𝑑 𝑠𝑡𝑒𝑒𝑙 1/2" bahan faktor/inch mild steel 1.4 plywood 1/2" 0.63 rookwool 3.03 mild steel 1/2" 0.7 air space 1 hardwood 0.91 gypsum 0.45 kostruksi dinding luar (sisi kanan) U= 0.147928994 konstruksi dinding depan dan belakang U= 0.233100233 konstruksi sisi kiri U= 0.229357798 konstruksi langit-langit U= 0.465116279 Konstruksi lantai U= 0.621118012
  21. 21. Film Room
  22. 22. TV Room
  23. 23.  III. CFM dan Ducting
  24. 24. Perhitungan CFM dan Diameter ducting
  25. 25. Ducting
  26. 26. EQUAL FRICTION
  27. 27. Kunjungan Ke DKB  Pada kunjungan ke DKB ini kami berangkat pukul 6 pagi dari kampus dan sampai di tujuan sekitar pukul 8. Kami langsung menuu kantor SDM DKB untuk menyerahkan surat pengantar dari DTM. Namun ternyata Bapak General Manager dari DKB tidak ada di tempat sehingga kami tidak mendapatkan izin untuk langsung ke lapangan.
  28. 28. Karena tidak mendapatkan izin, kami hanya mendapatkan pengarahan dari bagian SDM tersebut. Kami berbicang-bincang mengenai sistem tata udara kapal terakhir yang sedang dibangun (BCM 5500). Secara umum, pengetahuan tentang sistem tata udara yang dijelaska langsung di lapangan tidak beda jauh dengan apa yang telah kami dapatkan di kelas. Para petugas DKB menjelaskan pengerjaan kapalmsecara umum sampai bisa dilucurkan. Kemudian mereka juga menjelasakan khusus pada bagian tat udaranya. STU dari kapal akan dibuat ketika kerangka kapal sedah jadi dan dengan perhitungan yang sangat matang. Disini dijelaskan bahwa cooling load dihitung dari berbagai aspek, seperti pengaruh kaca,pengaruh sinar matahari,pengaruh jenis bahan dinding,atap dan lantai dari ruangan, volume ruangan, banyak orang di dalam ruangan. Dan banyak lagi sesuai dengan apa yang kami hitungh pada perhitungan tugas sistem tata udara ini. Sayangnya, pada kunjungan ini kami tidak diperbolehkan ke kapal BCM 5500 sehingga kami hanya bisa saling betukar pikiran dengan para pekerja yang ada di kantor.
  29. 29. Foto-foto dokumentasi
  30. 30.  TERIMA KASIH

×