  1. 1. Gozzer Ranch Water and Wastewater System Overview Dan Messier North Kootenai Water and Sewer District
  2. 2. Coeur d’Alene, Idaho
  3. 3. North Kootenai Water and Sewer District • Serve 15 small communities with potable water • 2 Surface water treatment plants • 1 Water Reclamation Plant • Over 4000 customers • 5 member board of directors
  4. 4. Operations Staff • 5 construction & maintenance specialists • 1 Field Supervisor • 1 Wastewater Manager • 1 part time electrician • 3 office staff • 1 District Manager
  5. 5. Gozzer Ranch Golf and Lake Club • 600 acre site • 120 acres of golf course • Golf course designed by Tom Fazio • Water Taxi service from Coeur d’Alene to site
  6. 6. Gozzer Ranch Golf and Lake Club • Built on solid basalt mountain - all water and sewer lines had to be blasted in. • Encompasses Arrow Point community • Marina • Eddie’s Restaurant
  7. 7. Surface Water Treatment Plant • 4 submersible lake intake pumps mounted on sled in Coeur d’Alene Lake • System limited to 2 cfs or roughly 900 gallons a minute • Pumps provide water for drinking water as well as irrigation usage
  8. 8. Surface Water Treatment Plant • 4 slow sand filtration beds • 900 gpm capacity • 150,000 gallon standpipe reservoir • SCADA controlled
  9. 9. Surface Water Treatment Plant
  10. 10. Water Reclamation Plant • Serves all of Gozzer Ranch and Arrow point Community Sewer Systems-583 ER’s • Class A recycled water • U.S. Filter Memjet Membrane filtration System
  11. 11. Water Reclamation Plant • 130,000 gpd Membrane Bio Reactor • 1 MG Bypass/ Storage Pond • 7 MG Golf Lake • Activated Carbon Air Scrubber • SCADA System • UV Disinfection System • Methanol Injection
  12. 12. Water Reclamation Plant • Prescreening • Anoxic Zone • Aeration chamber • Membrane tank-2 modules • 2 Membrane racks per module • 32 membranes per Rack • Ultraviolet disinfection
  13. 13. Water Reclamation Plant
  14. 14. Plant Effluent limits • 2.2 Total Coliform 7 day mean average • 30 mg/l Total Nitrogen • 10 mg/l BOD • 0.2 NTU Mean Turbidity – 0.5 NTU Max • Class III Operator • No restriction on application • No land Application Permit required
  15. 15. Golf course pond
  16. 16. Golf course pond

×