Data Center Consolidation & Springfield Data Center Program Integrated Commisioning Program
Integrated Commissioning  <ul><li>Security </li></ul><ul><li>Management </li></ul><ul><li>Cooling </li></ul><ul><li>Physic...
Power  <ul><li>UPS </li></ul><ul><li>GENERATOR </li></ul><ul><li>BYPASS </li></ul><ul><li>CIRCUIT BREAKERS </li></ul><ul><...
Integrated Commissioning Checklist starting point Commissioning Scope Master Check List Power Test Cooling Test Fire Suppr...
Electrical <ul><li>Electrical Distribution </li></ul><ul><li>Circuit Breakers </li></ul><ul><li>Transformers </li></ul><ul...
Mechanical Systems <ul><li>Fuel Oil Delivery System for Standby Generators </li></ul><ul><li>Chillers </li></ul><ul><li>Co...
FIRE LIFE SAFETY (FLS) AND PROTECTION SYSTEMS <ul><li>Fire Detection and Alarm System </li></ul><ul><li>Life Safety System...
BUILDING MANAGEMENT SYSTEM AND CONTROL <ul><li>Building Management System (BMS) </li></ul><ul><li>Building Controls </li><...
SECURITY SYSTEMS <ul><li>Closed Circuit TV System </li></ul><ul><li>Intrusion Detection </li></ul>
Envelope <ul><li>Visual Inspection – This is an on-site inspection of the building to assess building conditions. A visual...
Upcoming SlideShare
Loading in …5
×

Data Center Program Integrated Commissioning Program Baseline

3,567 views

Published on

Baseline for Data Center Commissioning

Published in: Business
0 Comments
3 Likes
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total views
3,567
On SlideShare
0
From Embeds
0
Number of Embeds
9
Actions
Shares
0
Downloads
0
Comments
0
Likes
3
Embeds 0
No embeds

No notes for slide

Data Center Program Integrated Commissioning Program Baseline

  1. 1. Data Center Consolidation & Springfield Data Center Program Integrated Commisioning Program
  2. 2. Integrated Commissioning <ul><li>Security </li></ul><ul><li>Management </li></ul><ul><li>Cooling </li></ul><ul><li>Physical Building (envelope) and Grounds </li></ul><ul><li>Fire Suppression </li></ul><ul><li>Power </li></ul>
  3. 3. Power <ul><li>UPS </li></ul><ul><li>GENERATOR </li></ul><ul><li>BYPASS </li></ul><ul><li>CIRCUIT BREAKERS </li></ul><ul><li>OTHER SYSTEMS </li></ul><ul><li>Envelope (Roof leaks/Walls/Vapor Gaps) </li></ul>
  4. 4. Integrated Commissioning Checklist starting point Commissioning Scope Master Check List Power Test Cooling Test Fire Suppression and Security Test Infrastructure Monitor Systems and Control Tests High Density Load Testing (using independent Rack Heaters ) Systems Grounding Chillers Pipes Power Monitoring System Power Distribution installation UPS Chilled water Pumps sprinklers CRAC Monitoring System Hot/Cold Aisle air flow Automatic Transfer Switch (ATS) Cooling Tower Gauges Humidity Sensors Rack Hot air flow patterns Integrated Power Systems Condenser Water Pumps Pumps Temperature Sensors Rack mounted outlets in the rack EPO Piping Automatic Alarms Motion Detection sensors PDU serving the rack heat exchanger Smoke Detection Building Management System   CRAC (like) Electronics       Ducting and air flow Man Traps       integrated cooling systems Door Lock Systems       Test power and Cooling together Test power and Cooling together   Security Camera    
  5. 5. Electrical <ul><li>Electrical Distribution </li></ul><ul><li>Circuit Breakers </li></ul><ul><li>Transformers </li></ul><ul><li>Relays </li></ul><ul><li>Grounding (Building and Raised Floor) </li></ul><ul><li>Uninterruptible Power Supply (UPS) </li></ul><ul><li>Power Distribution Units (PDU) </li></ul><ul><li>Generator or Standby Emergency Power (SEP) </li></ul><ul><li>Lightning Protection </li></ul>
  6. 6. Mechanical Systems <ul><li>Fuel Oil Delivery System for Standby Generators </li></ul><ul><li>Chillers </li></ul><ul><li>Cooling Towers </li></ul><ul><li>Computer Room Air Conditioning Units (CRAC) </li></ul><ul><li>Thermal Energy Storage </li></ul><ul><li>Fan Systems </li></ul><ul><li>Heat Exchangers </li></ul><ul><li>Heating, Ventilating and Air Conditioning (HVAC) System and Controls </li></ul><ul><li>Pumps </li></ul><ul><li>Boilers </li></ul><ul><li>Floor Drains </li></ul>
  7. 7. FIRE LIFE SAFETY (FLS) AND PROTECTION SYSTEMS <ul><li>Fire Detection and Alarm System </li></ul><ul><li>Life Safety Systems </li></ul><ul><li>Fire Suppression System </li></ul><ul><li>Wet Sprinklers </li></ul><ul><li>Preaction Sprinkler </li></ul><ul><li>FM 200 </li></ul>
  8. 8. BUILDING MANAGEMENT SYSTEM AND CONTROL <ul><li>Building Management System (BMS) </li></ul><ul><li>Building Controls </li></ul><ul><li>EPO (Emergency Power Off) Systems </li></ul><ul><li>Monitoring and Control Systems </li></ul>
  9. 9. SECURITY SYSTEMS <ul><li>Closed Circuit TV System </li></ul><ul><li>Intrusion Detection </li></ul>
  10. 10. Envelope <ul><li>Visual Inspection – This is an on-site inspection of the building to assess building conditions. A visual inspection is performed in combination with some form of non-invasive testing. Depending on the nature or complexity of the issue, the findings of this inspection can be used to create a detailed plan of action to diagnose and determine causes. </li></ul><ul><li>Non-Invasive Testing – This testing is used to support the findings of the visual inspection. Electronic moisture detection equipment, moisture measurement tools, permeability testing, borescope cameras, hygrometers, plus other equipment and test methods can be used to assess the building. </li></ul><ul><li>Invasive Testing & Analysis – Invasive testing is used to verify findings, determine if proper components were used in construction, verify if proper installation or repair techniques were followed, and to define the extent of a problem. Examples of invasive testing include the removal of various materials and claddings, sealant testing, and water testing. </li></ul>

×