Ercon Catheter ProductsHole PuncHing SyStemS   Ercon Catheter Products, state of the art, punching and   skiving systems a...
Ercon Catheter Productscontract manufacturing Ercon Catheter Products name is synonymous with the design and fabrication o...
Ercon Catheter Productsi.V. aSSembly equiPment This equipment is used to assemble the catheter tubing to the molded hub an...
Ercon Catheter ProductscatHeter tiP forming SyStemS   We can create a tip forming system to meet the needs   of your parti...
Upcoming SlideShare
Loading in …5
×

Olsen Medical Ercon Catheter Products New Brochures 2010

1,216 views

Published on

Olsen Medical Ercon Catheter Products

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
1,216
On SlideShare
0
From Embeds
0
Number of Embeds
19
Actions
Shares
0
Downloads
3
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Olsen Medical Ercon Catheter Products New Brochures 2010

  1. 1. Ercon Catheter ProductsHole PuncHing SyStemS Ercon Catheter Products, state of the art, punching and skiving systems are capable of creating a variety of hole SyStem RequiRementS sizes and shapes. The systems are designed to meet • Operated by foot switch your specific requirements. • Electrical: 115 VAC or 230 VAC Precision punching: holes can be punched from • Air Pressure: 80-100 psi .040 inches (1 mm) in diameter. SyStem CapabilitieS • Punched holes can be round, oval, or irregular in shape • Holes can be punched through the tube side wall • Holes can be punched straight through both sides • Holes can be punched straight one side • Holes can be punched through a single lumen of multiple lumen tubes • Multiple holes can be punched simultaneously • Tubing can be cut to length • Tubing can be indexed between punch operations for special hole patterns • Quick change modules allow many styles of holes to be punched using one system • Modules are designed to punch and/or cut-off tubing to specific configurations Oregon Sales Office www.olsenmedical.com 3230 Commerce Center Place Phone (503) 781-0184ercon@olsenmedical.com Louisville, KY 40211 Fax (503) 536-6688
  2. 2. Ercon Catheter Productscontract manufacturing Ercon Catheter Products name is synonymous with the design and fabrication of high-quality and reliable Tip Forming and Hole Punching Systems. For over 15 years, our systems have been in operation in catheter manufacturing facilities worldwide. From Concept to Production our engineering services will provide a proven design and manufacturing process that will help you get to market faster. All of our catheter manufacturing is designed to customer specifications where we utilize a class 100,000 clean room. let uS manufaCtuRe youR pRoduCt • Precise, Repeatable Tip Forming We will design customized tooling for your application and Hole Punching and provide samples for your approval prior to production. We have the equipment and experience • Engineering and Design in-house to keep your start-up costs low and your • Technical Support and Service deliveries on-time. • Supply Chain Management Whether it is a tip forming or hole punching application, • Customized Tooling Ercon Catheter Products can produce the precise, • Clean Room: Class 100,000 repeatable product that you seek, as well as the service • Packaging and Labeling and support that you need. • Sterilization Services • Over 15 Years of Experience and Expertise • On-time Deliveries Oregon Sales Office www.olsenmedical.com 3230 Commerce Center Place Phone (503) 781-0184ercon@olsenmedical.com Louisville, KY 40211 Fax (503) 536-6688
  3. 3. Ercon Catheter Productsi.V. aSSembly equiPment This equipment is used to assemble the catheter tubing to the molded hub and form the tips. Each machine requires special tooling for each different size of catheter. The tooling is designed for a specific style of catheter, and can be designed to any hub desired; standard, winged, or with ports. flanging/flaRing equipment • This unit is used to form a flange or flare on the I.V. tube where it fits into the molded hub. The flange or flare is required whether you ultrasonically weld or insert mold the two pats together. This system is a shuttle unit, which uses one operator to load one side while the other side is forming. i.V. tip foRming equipment • The I.V. Tip forming machine forms a very precise taper on I.V. Catheter tubing. The tubes can be formed after assembly with the hubs or prior to the assembly. Sizes range from 26Ga. to 14Ga. or larger. Tube holding fixtures can accommodate standard hubs, winged hubs, or hubs with ports. Oregon Sales Office www.olsenmedical.com 3230 Commerce Center Place Phone (503) 781-0184ercon@olsenmedical.com Louisville, KY 40211 Fax (503) 536-6688
  4. 4. Ercon Catheter ProductscatHeter tiP forming SyStemS We can create a tip forming system to meet the needs of your particular application. Our tip forming systems SyStem featuReS incorporate the Ameritherm® Solid State RF Induction • Time controlled cycle • Solid state generator Generator, which quickly obtain desired temperatures, 1kW, 2kW, 2.4kW, 4.2kW producing fast cycle times. • Easy troubleshooting features • Dual finger switches as an option • Precise control of the forming process Combined with solid state electronics, PLC control, and • Tight tolerances a programmable touch-screen display, you are getting the • Smooth surfaces • No flash highest quality, and performance from each and every • Maximum performance cycle. • PLC control with touch-screen display and customized control The tip forming system is also equipped with quick change SyStem RequiRementS tooling, allowing multiple size catheters to be run on the • Operated by foot switch same machine. Our standard tip forming equipment can • Electrical: 115 VAC or 230 VAC produce 1 to 4 catheters at a time, with special systems • Air Pressure: 80-100 psi capable of producing up to 30 catheters per minute. SyStem CapabilitieS • Highly repeatable precision formed catheter tips • Welding plastic to plastic • Bonding plastic to metal • Bonding balloons with smooth joint transition • Spot sealing of lumens • Closed or tapered tubing ends • Forming of neck downs and flares • Radius both tip ID and OD • Braided and non-braided tubing • Forming of intricate shapes • Improved output quality • Quantifiable and Validate-able process typiCal tubing end pRofileS • Closed end spherical radius • Closed end bullet nose • Open end delee • Open end whistle tip • Coudé Oregon Sales Office www.olsenmedical.com 3230 Commerce Center Place Phone (503) 781-0184ercon@olsenmedical.com Louisville, KY 40211 Fax (503) 536-6688

×