TECHNICAL SERVICES <ul><li>Thermal Facilities </li></ul><ul><li>Building glazing thermal analysis – relative to facades an...
 
 
TECHNICAL SERVICES <ul><li>Day lighting Facilities </li></ul><ul><li>Building day light analysis – relative to facades and...
TECHNICAL SERVICES Day lighting Facilities
TECHNICAL SERVICES Day lighting Facilities
TECHNICAL SERVICES <ul><li>Structural Facilities </li></ul><ul><li>Wind flow around facades </li></ul><ul><li>Wind flow ar...
TECHNICAL SERVICES <ul><li>Ventilation Facilities </li></ul><ul><li>Natural ventilation and free air flow through </li></u...
TECHNICAL SERVICES <ul><li>Testing </li></ul><ul><li>Site water permeability test carried out to CWCT test method 9 </li><...
TECHNICAL SERVICES <ul><li>Standards & Affiliates </li></ul><ul><li>CDM regulations  </li></ul><ul><li>British standards <...
TECHNICAL SERVICES <ul><li>Accreditations </li></ul><ul><li>ISO 9001 Management Accreditation </li></ul><ul><li>ISO 14001 ...
Upcoming SlideShare
Loading in …5
×

Technical Notes

828 views

Published on

A few examples

0 Comments
1 Like
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total views
828
On SlideShare
0
From Embeds
0
Number of Embeds
29
Actions
Shares
0
Downloads
0
Comments
0
Likes
1
Embeds 0
No embeds

No notes for slide

Technical Notes

  1. 5. TECHNICAL SERVICES <ul><li>Thermal Facilities </li></ul><ul><li>Building glazing thermal analysis – relative to facades and glazing </li></ul><ul><li>U-Value calculations </li></ul><ul><li>Advice on glass thermal coatings </li></ul><ul><li>Advice on part L of building regulations related to glazing element </li></ul><ul><li>2D Infrared thermal simulation of products </li></ul><ul><li>2D Flux magnitude simulation of products </li></ul><ul><li>Display Isotherms through detail section </li></ul><ul><li>Dew point calculation </li></ul><ul><li>Interstitial condensation assessments </li></ul>
  2. 8. TECHNICAL SERVICES <ul><li>Day lighting Facilities </li></ul><ul><li>Building day light analysis – relative to facades and glazing </li></ul><ul><li>Stereographic diagrams to show sun path </li></ul><ul><li>Waldram diagrams to show sun path </li></ul><ul><li>Average daylight calculations for rooms </li></ul><ul><li>Advice on glare control glass </li></ul><ul><li>G-Value calculations </li></ul><ul><li>Light transmittance values </li></ul><ul><li>Reflectance values of glazing </li></ul><ul><li>Advice on near by obstructions relative to glazing – Right to light </li></ul><ul><li>Solar shading analysis to show shading on window throughout the year </li></ul>
  3. 9. TECHNICAL SERVICES Day lighting Facilities
  4. 10. TECHNICAL SERVICES Day lighting Facilities
  5. 11. TECHNICAL SERVICES <ul><li>Structural Facilities </li></ul><ul><li>Wind flow around facades </li></ul><ul><li>Wind flow around roof lights </li></ul><ul><li>Simple computational fluid dynamics </li></ul><ul><li>Area wind load to BS6399 for facades </li></ul><ul><li>Pressure zones across a façade to BS6399 </li></ul><ul><li>Uplift force for canopy’s and roof lights to BS6399 & BS5516 </li></ul><ul><li>Calculations for aluminium systems including: </li></ul><ul><li>Transom calculations </li></ul><ul><ul><li>Dead loads </li></ul></ul><ul><ul><ul><li>Design bending moment </li></ul></ul></ul><ul><ul><ul><li>Bending resistance </li></ul></ul></ul><ul><ul><ul><li>Design shear force </li></ul></ul></ul><ul><ul><ul><li>Shear resistance </li></ul></ul></ul><ul><ul><ul><li>Transom deflection due to dead load </li></ul></ul></ul><ul><ul><ul><li>Elastic moment for buckling </li></ul></ul></ul><ul><ul><li>Wind load checks </li></ul></ul><ul><ul><ul><li>Design bending moment </li></ul></ul></ul><ul><ul><ul><li>Bending resistance </li></ul></ul></ul><ul><ul><ul><li>Design shear force </li></ul></ul></ul><ul><ul><ul><li>Shear resistance </li></ul></ul></ul><ul><ul><ul><li>Transom deflection due to wind load </li></ul></ul></ul><ul><ul><ul><li>Elastic moment for buckling </li></ul></ul></ul><ul><ul><ul><li>Combined loading </li></ul></ul></ul><ul><li>Mullion calculations </li></ul><ul><ul><li>Wind load per span </li></ul></ul><ul><ul><li>Bending moment </li></ul></ul><ul><ul><li>Peak shear force </li></ul></ul><ul><ul><li>Bending resistance </li></ul></ul><ul><ul><li>Buckling check </li></ul></ul><ul><ul><li>Shear resistance </li></ul></ul><ul><ul><li>Deflection check </li></ul></ul><ul><ul><li>Tensile stress </li></ul></ul><ul><ul><li>General yielding along the member </li></ul></ul><ul><ul><li>Local failure at critical section </li></ul></ul>
  6. 12. TECHNICAL SERVICES <ul><li>Ventilation Facilities </li></ul><ul><li>Natural ventilation and free air flow through </li></ul><ul><li>Louvre systems </li></ul><ul><li>Slot trickle vents </li></ul><ul><li>Glazed in trickle vents </li></ul><ul><li>Adjustable Air flow </li></ul><ul><li>Smoke vents </li></ul>
  7. 13. TECHNICAL SERVICES <ul><li>Testing </li></ul><ul><li>Site water permeability test carried out to CWCT test method 9 </li></ul><ul><li>Thermograph of facades before and after </li></ul><ul><li>Infrared images showing surface temperatures </li></ul>
  8. 14. TECHNICAL SERVICES <ul><li>Standards & Affiliates </li></ul><ul><li>CDM regulations </li></ul><ul><li>British standards </li></ul><ul><li>Building regulations </li></ul><ul><li>CWCT standards for systemised building envelope </li></ul><ul><li>Seat on board for - Council for Aluminium Building - Technical Committee </li></ul><ul><li>Member of CAB </li></ul><ul><li>Member of Centre for window and cladding technology </li></ul><ul><li>Member Glass & Glazing Federation </li></ul><ul><li>Member of construction line </li></ul><ul><li>About to become member of “The green organisation” – Green apple award </li></ul>
  9. 15. TECHNICAL SERVICES <ul><li>Accreditations </li></ul><ul><li>ISO 9001 Management Accreditation </li></ul><ul><li>ISO 14001 Environmental Accreditation </li></ul><ul><li>ISO 18001 Health & Safety Accreditation </li></ul><ul><li>All fitters carry CSCS cards </li></ul><ul><li>All fitters have CRB checks </li></ul><ul><li>Chas accreditation </li></ul>

×