Successfully reported this slideshow.
We use your LinkedIn profile and activity data to personalize ads and to show you more relevant ads. You can change your ad preferences anytime.
TUGAS ECHOCARDIOGRAPHY
PENGAMBILAN GAMBARAPIKAL
VIEW, SUBCOSTAL VIEW DAN
SUPRA STRENAL VIEW
 1. AGUNG PRATAMA
 2. CAHYA SETIYA
 3. ESAR ARAS SANZABIL
 4. KHAIRUL HUDDA
 5. YUDI LESMANA
12/12/12
12/12/12
APICAL VIEW
APIKAL 4 CHAMBERS
* Fungsi diastolik LV
* TAPSE
APIKAL 5 CHAMBERS
*AoVmax
APIKAL 2 CHAMBERS
APIKAL 3 CHAMB...
POSISI TRANDUSER POTONGAN
APIKAL
Cara pengambilan
gambar 4 chamber
1. Pasien sedikit di terlentangkan
2. Marker di posisikan ke bawah searah jam 3 dari
tub...
APICAL 4 CHAMBER
12/12/12
Apical 4 Chamber (4 CH)
 2 D
 Menilai gerakan (Motion )
 Katup Trikuspid
 Katup Mitral (MV)
 Pericard
APIKAL 4 CHAMBER COLOUR
DOPPLER
STRUKTUR JANTUNG PADA APIKAL
VIEW
PERBEDAAN LV DAN RV
Mitral valve flow doppler
MITRAL FLOW
12/12/12
Pengukuran Mitral Flow
Pengukuran doppler mitral flow
dilakukan pada gambaran
pemotongan 4 ch dimana pada
penguku...
12/12/12
• Untuk mengetahui fungsi diastolik LV ,
Sample volume ( sv ) harus diletakan
pada katup mitral
• Beri Doppler PW...
RV FUNGSI(TAPSE)
Pengukuran Fungsi Ventrikel Kanan
- pengukuran Trikuspid
annular plain sistolik
ekskursion (TAPSE)
-Langkah pengambilan ya...
NILAI TAPSE
12/12/12
Normal Tapse
 1,6 cm = 16 mm
Tapi Kalau ada kebocoran Katup rikuspid
Harus > 2 cm = 20 mm
Apikal view , 5 Chambers
Untuk
mendapat
apikal 5
view, Trandus
er tilting
sedikit ke arah
kaudal dari
posisi apikal4
chamb...
Apical 5 chamber view
Indicator 4-5 o’Clock
APIKAL 5 CHAMBER
STRUKTUR PADA APIKAL 5
CHAMBER
Apical 5 chamber view
Scan :
Tricuspid Valve
Mitral Valve
Aortic valve
12/12/12
AoVmax berfungsi untuk melihat
atau low output sirkulation
Nilai aoV max > dari 0,8 5 m/s
Prinsip Doppler
Apikal view 2 Chamber
Rotasi
Tranduser
60 derajat
counterclock
wise
 2 D
 Menilai gerakan (
Motion )
 Katup Mitral ( MV
Apikal view 2 Chambers
12/12/12
Untuk melihat Fungsi diastolik LV
E/A = > 1
STRUKTUR JANTUNG PADA 2
CHAMBERS
Apikal View 3 Chambers
Untuk
mendapat
apikal 3
chamber, kem
bali rotasi 90
derajat
counterclockw
ise
Apikal View 3 Chambers
STRUKTUR JANTUNG PADA 3
CHAMBERS
Sub Costal/ Sub Xiphoid
Tranduser diatas
Xiphoid, marker jam 12
Tilting tranduser ke bahu
kiri: gambaran long axis
POSISI TRANDUSER POTONGAN SUB COSTAL
12/12/12
Kaki nya di tekuk
STRUKTUR JANTUNG POSISI
SUBCOSTAL
Subcostal view long axis
Indicator 3 – 4 o’clock
ptv
stv
Subcostal
 Subcostal
 Menilai gerakan ( Motion )
 IVC
Subcostal view short axis
Tilting up  down
GAMBARAN VENA CAVA INFERIOR
M MODE PADA VENA CAVA
INFERIOR
12/12/12
Nilai Mengukur IVC
Cara mengukur
Tranduser diletakan subcostal
M MODE
DIUKUR 1,5-2 CM DARI PINTU RA
IVC NORM...
SUPRA STERNAL
Pasien terlentang
, kepala tengadah/
hiper ekstensi.
Transduser pada
angulus Lidovici.
Long axis :Posisi
Mar...
gambar55
STRUKTUR JANTUNG SUPRASTERNAL
12/12/12
Untuk Melihat Cortasio Aorta
12/12/12
TERIMA KASIH
Apikal view,subcostal view,dan supra sternal view
Apikal view,subcostal view,dan supra sternal view
Apikal view,subcostal view,dan supra sternal view
Apikal view,subcostal view,dan supra sternal view
Apikal view,subcostal view,dan supra sternal view
Apikal view,subcostal view,dan supra sternal view
Upcoming SlideShare
Loading in …5
×

Apikal view,subcostal view,dan supra sternal view

719 views

Published on

echocardiography

Published in: Health & Medicine
  • Be the first to comment

  • Be the first to like this

Apikal view,subcostal view,dan supra sternal view

  1. 1. TUGAS ECHOCARDIOGRAPHY PENGAMBILAN GAMBARAPIKAL VIEW, SUBCOSTAL VIEW DAN SUPRA STRENAL VIEW
  2. 2.  1. AGUNG PRATAMA  2. CAHYA SETIYA  3. ESAR ARAS SANZABIL  4. KHAIRUL HUDDA  5. YUDI LESMANA 12/12/12
  3. 3. 12/12/12
  4. 4. APICAL VIEW APIKAL 4 CHAMBERS * Fungsi diastolik LV * TAPSE APIKAL 5 CHAMBERS *AoVmax APIKAL 2 CHAMBERS APIKAL 3 CHAMBERS
  5. 5. POSISI TRANDUSER POTONGAN APIKAL
  6. 6. Cara pengambilan gambar 4 chamber 1. Pasien sedikit di terlentangkan 2. Marker di posisikan ke bawah searah jam 3 dari tubuh pasien 12/12/12
  7. 7. APICAL 4 CHAMBER
  8. 8. 12/12/12 Apical 4 Chamber (4 CH)  2 D  Menilai gerakan (Motion )  Katup Trikuspid  Katup Mitral (MV)  Pericard
  9. 9. APIKAL 4 CHAMBER COLOUR DOPPLER
  10. 10. STRUKTUR JANTUNG PADA APIKAL VIEW
  11. 11. PERBEDAAN LV DAN RV
  12. 12. Mitral valve flow doppler
  13. 13. MITRAL FLOW
  14. 14. 12/12/12 Pengukuran Mitral Flow Pengukuran doppler mitral flow dilakukan pada gambaran pemotongan 4 ch dimana pada pengukuran ini untuk mendapatkan fungsi diastolik, untuk nilai normal E/A adalah > 1
  15. 15. 12/12/12 • Untuk mengetahui fungsi diastolik LV , Sample volume ( sv ) harus diletakan pada katup mitral • Beri Doppler PW • E/A = harus > 1 • Kalau < 1 adanya gangguan Diastolik
  16. 16. RV FUNGSI(TAPSE)
  17. 17. Pengukuran Fungsi Ventrikel Kanan - pengukuran Trikuspid annular plain sistolik ekskursion (TAPSE) -Langkah pengambilan yaitu dengan cara potongan 4 Ch kemudian letakkan cursor pada dinding ventrikel kanan – ukur tinggi dari undulasi diding tersebut ( dari gelombang R sampai gelombang T pada gambaran EKG ) nilai normal adalah 1,6
  18. 18. NILAI TAPSE 12/12/12 Normal Tapse  1,6 cm = 16 mm Tapi Kalau ada kebocoran Katup rikuspid Harus > 2 cm = 20 mm
  19. 19. Apikal view , 5 Chambers Untuk mendapat apikal 5 view, Trandus er tilting sedikit ke arah kaudal dari posisi apikal4 chambers
  20. 20. Apical 5 chamber view Indicator 4-5 o’Clock
  21. 21. APIKAL 5 CHAMBER
  22. 22. STRUKTUR PADA APIKAL 5 CHAMBER
  23. 23. Apical 5 chamber view Scan : Tricuspid Valve Mitral Valve Aortic valve
  24. 24. 12/12/12 AoVmax berfungsi untuk melihat atau low output sirkulation Nilai aoV max > dari 0,8 5 m/s
  25. 25. Prinsip Doppler
  26. 26. Apikal view 2 Chamber Rotasi Tranduser 60 derajat counterclock wise  2 D  Menilai gerakan ( Motion )  Katup Mitral ( MV
  27. 27. Apikal view 2 Chambers
  28. 28. 12/12/12 Untuk melihat Fungsi diastolik LV E/A = > 1
  29. 29. STRUKTUR JANTUNG PADA 2 CHAMBERS
  30. 30. Apikal View 3 Chambers Untuk mendapat apikal 3 chamber, kem bali rotasi 90 derajat counterclockw ise
  31. 31. Apikal View 3 Chambers
  32. 32. STRUKTUR JANTUNG PADA 3 CHAMBERS
  33. 33. Sub Costal/ Sub Xiphoid Tranduser diatas Xiphoid, marker jam 12 Tilting tranduser ke bahu kiri: gambaran long axis
  34. 34. POSISI TRANDUSER POTONGAN SUB COSTAL
  35. 35. 12/12/12 Kaki nya di tekuk
  36. 36. STRUKTUR JANTUNG POSISI SUBCOSTAL
  37. 37. Subcostal view long axis Indicator 3 – 4 o’clock ptv stv
  38. 38. Subcostal  Subcostal  Menilai gerakan ( Motion )  IVC
  39. 39. Subcostal view short axis Tilting up  down
  40. 40. GAMBARAN VENA CAVA INFERIOR
  41. 41. M MODE PADA VENA CAVA INFERIOR
  42. 42. 12/12/12 Nilai Mengukur IVC Cara mengukur Tranduser diletakan subcostal M MODE DIUKUR 1,5-2 CM DARI PINTU RA IVC NORMAL = < 1,3 cm
  43. 43. SUPRA STERNAL Pasien terlentang , kepala tengadah/ hiper ekstensi. Transduser pada angulus Lidovici. Long axis :Posisi Marker ke arah kepala Pasien. Short axis: Rotasi 90 derajat clockwise
  44. 44. gambar55
  45. 45. STRUKTUR JANTUNG SUPRASTERNAL
  46. 46. 12/12/12 Untuk Melihat Cortasio Aorta
  47. 47. 12/12/12
  48. 48. TERIMA KASIH

×