Successfully reported this slideshow.
We use your LinkedIn profile and activity data to personalize ads and to show you more relevant ads. You can change your ad preferences anytime.

Solid state relay_catalog

1,347 views

Published on

solid

Published in: Automotive
  • Be the first to comment

Solid state relay_catalog

  1. 1. CATALOG 2013-2014 Place your Order now! And get 20% OFFthe price 20% OFF
  2. 2. 100% SATICFACTION 100% SATICFACTION Why do you choose our company? Shanghai AOYI Electric Company limtid owns two producing factories with 20 years production history. It is dedicated to developing, producing and marketing Solid State Relay,SCRPower Regulator,Ampere or Voltage Meter,Temperature Control Instrument,etc. We devote to be the best supplier of products and services to our global custormers at the best price. Look what you can buy?
  3. 3. OUR CUSTOMER IN THE WORLDOUR CUSTOMER IN THE WORLD Our products fit Asia maket perfectly, for our products are very cheap but high quality,especially in China our products cover every province and city. Our products fit Asia maket perfectly, for our products are very cheap but high quality,especially in China our products cover every province and city. Some countries in Europe also began using our products, with top grade products and excellent service,we obtain accordant appreciation from them Some countries in Europe also began using our products, with top grade products and excellent service,we obtain accordant appreciation from them In South America we have hold a few marketing share, and this will be more and more. In South America we have hold a few marketing share, and this will be more and more. Our products have been sold far to North America. We have wonn favorable comments from American customers. Our products have been sold far to North America. We have wonn favorable comments from American customers. We have already entered Africa market, and our prodcuts are very popular in Africa. We will help them to develop the economy. We have already entered Africa market, and our prodcuts are very popular in Africa. We will help them to develop the economy. CHILE, INSTRUMENTACION TÉCNICA LTDA CHILOE 1142-B, SANTIAGO, F:02-25540140
  4. 4. SSRAC Solid State Relay SSRAC Solid State Relay Solid state relay is usually called SSR for short. It is a new type of nono-contact switching device SSR is usually a four-terminal active device including two control terminals and two output terminals, and input and output terminals adopts reliable isolation. Solid state relay adopts flame resistant engineering plastic case, epoxy resin encapsulation, screw thread educing terminal connection with high strength structure, impulse resistance,high shock resistance performance, small driving current for input terminal and convenient connection with computer teminal and digital control circuit. 01 02 Input signal can make computer terminal and digital logic circuit compatible. Optical isolation between input and output loop, 4000VAC dielectric withstanding voltage LED indication for working state Built-in RC absorption circuit Dielectric insulating strengh: 50M> Ω > <Action reponse time:ON 10mS OFF 10mS SUMMARYSUMMARY Basic Character of Solid State RelayBasic Character of Solid State Relay 1 2 34 24~380VAC Solid State Relay SSR-40DA 40A INPUT 3~32VDC ~~ +_ R IN DC3-32V OUT ON OFF New Design Conform to IP ProtectionNew Design Conform to IP Protection Pretty cap-exterior match safe and high quality requirement High Voltage ThyristorHigh Voltage Thyristor Core adopts:imported components, endure high current and voltage constantcurrentinputcircuit zero-cross-overtriggeringloop 3-32VDC +3 -4 Wiring Connection SimpleWiring Connection Simple Zero-crossing triggering, eliminates the surge current completely Load 24-380VAC 2 1 Manufacturing Technique We select high quality SCR, DCB ceramic substrate and SMT technics. 1. ON-OFF Mode:zero cross triggering and random triggering1. ON-OFF Mode:zero cross triggering and random triggering Zero cross triggering can be used as “switch”, Random triggering can be used to control shift phase pulse to adjust load voltage. First, you should know classification of solid state relay,more details are as following:First, you should know classification of solid state relay,more details are as following: 2. Output Components:bidirectional SCR output(ordinary type) and anti-paralleled two single phase SCR(enhanced type): 2. Output Components:bidirectional SCR output(ordinary type) and anti-paralleled two single phase SCR(enhanced type): Ordinary type is used for low current module or resistive load. Enhanced type is used for high current module or inductive load. 3. Mounting Type: PCB tapered plug type,rail type,bolt type3. Mounting Type: PCB tapered plug type,rail type,bolt type Cooling way of PCB tapered plug type is air-cooling,need not to match radiator. Rail type is cooled by air or radiator Bolt type is cooled by radiator. 4. Output Voltage Grades:220VAC,380VAC,480VAC,660VAC4. Output Voltage Grades:220VAC,380VAC,480VAC,660VAC 220VAC voltage grades is used for 220VAC resistive load 380VAC voltage grades is used for 220VAC inductive load and 380VAC resistive load 480/660VAC voltage grades is used for 380VAC inductive load. How to select SSR?How to select SSR? 1.Resistive Load: twice load rated current 2.AC Motor Load: 6-7 times motor rated current 3.AC Electromagnet,Intermediate Relay and Inductive Coil Load: 4 times load rated current 4.Power Compensator Capacitor Load: 5 times load rated current 5.Transformer Load: 5 times transformer primary rated current 6.Special Inductive and Captive:you should enlarge current margin according to practical experience ≥ ≥ ≥ ≥ ≥ Second, you should know current of solid state relay,more details are as following:Second, you should know current of solid state relay,more details are as following: How to protect SSR?How to protect SSR? 1.Proper radiator adapted to the working requirement of solid state relay should be equipped, the allowance should be widened when the load radiating condition is not so good.You must avoid load short circuit. 2.Over Current Protection:over current and short circuit are the main reasons for permanent damage of internal SCR ,fast fuse and air switch is one of the methods for over current protection, fuse is also available for small current. 3.Over Voltage Protection:you can parallel voltage dependent resistor,its thickness decides the protective voltage value,generally,471/10D voltage dependent resistor is suitable for 220V series SSR, 681/10D for 380V series SSR, 821/10D for 480V
  5. 5. 1 2 34 24~380VAC Solid State Relay SSR-40AA 40A INPUT 90~250VAC ~~ R ~ ~ SSRSingle Phase Solid State Relay SSRSingle Phase Solid State Relay 03 04 Application Solid state relay is widely used in automatization control fields such as petrochemical equipment,food machine,packaging machine,textile machine,plastic machine,numerical control lathe,entertainment facility and so on, which especailly for severe environment full of corrosion,moisture,explosion-proof and dust-proof or places demanding frequent switching. Generally, our solid state relay are applied with temperature controller to control temperature of some machine, and different solid state relay should correspond to different output of temperature controller. The following wiring diagrams are for your reference only,please carry on the revision according to the actual need. 1 2 34 24~380VAC Solid State Relay SSR-40DA 40A INPUT 3~32VDC ~~ +_ R LOAD FUSE Power AC24-380V Attention SET PV SV ALM1 ALM2ONAT OFF 《 《 《 R XMT-2000 220VAC Voltage Pulse Output Thermocouple + - + _ DC-AC Solid State RelayDC-AC Solid State RelayDC-AC Solid StateRelayDC-AC Solid StateRelay LOAD FUSE Power AC24-380V SET PV SV ALM1 ALM2ONAT OFF 《 《 《 R XMT-2000 220VAC Relay Output Thermocouple + - AC-AC Solid StateRelayAC-AC Solid StateRelay 1 2 34 24~380VAC Solid State Relay SSR-25VA 25A 500KΩ 1/4W ~~ R ~ ~ FUSE LOAD Manual Solid State Voltage RegulatorManual Solid State Voltage Regulator Power AC24-380V 500K potentiometer control output% 1 2 34 24~380VAC Solid State Relay SSR-40DA-P 40A INPUT 4~8VDC ~~ +_ R LOAD FUSE Power AC24-380V SET PV SV ALM1 ALM2ONAT OFF 《 《 《 R XMT-2000 220VAC Thermocouple + - Voltage Pulse Output L N Random Solid State Voltage RegulatorRandom Solid State Voltage Regulator A1 4~32VDC C2B2A2 C1B1 SSR3-40DA R THREE PHASE MADE IN HUANAN SOLID STATE RELAY 40A 24~380VAC + - Single Phase Solid State RelaySingle Phase Solid State Relay Three Phase Solid State RelayThree Phase Solid State Relay SET PV SV ALM1 ALM2ONAT OFF 《 《 《 R XMT-2000 Voltage Pulse Output Thermocouple + - + _ A B C N A1 4~32VDC C2B2A2 C1B1 SSR3-40DA R THREE PHASE MADE IN HUANAN SOLID STATE RELAY 40A 24~380VAC + - SET PV SV ALM1 ALM2ONAT OFF 《 《 《 R XMT-2000 Voltage Pulse Output Thermocouple + - + _ A B C N A1 4~32VDC C2B2A2 C1B1 SSR3-40DA R THREE PHASE MADE IN HUANAN SOLID STATE RELAY 40A 24~380VAC + - SET PV SV ALM1 ALM2ONAT OFF 《 《 《 R XMT-2000 Voltage Pulse Output Thermocouple + - + _ A B C N Above is connection,load voltage is 380VAC,load must be three-phase balanced. And only three phase high voltage enhanced solid state relay is suitable for this connection. △ Above is Y connection,load votage is 220VAC,for three-phase unbalanced load,you should select NO.1 and the center must be zero line.
  6. 6. SSR Switching Output Control input Load Voltage Monitoring Zero cross Bidirectional SCR DC3-32V 24-380VAC Output status Input CircuitInput Circuit Control Voltage Control Current DC3-32V DC6-12mA Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage On-off Time Dielectric Strength General DataGeneral Data 24-380VAC ≤4mA 5A ≤1.5V ≤10mS Insulation Resistance Ambient Temperature Mounting Methods 1500VAC 100M 500VDCΩ@ -20~+70℃ PCB or Bolt Fixing SSRSingle Phase AC Solid State Relay SSR-380D05 Installation DemensionsInstallation Demensions Special Functions PCB Solid State Relay DC3-32V DC6-12mA 24-380VAC ≤4mA ≤1.5V ≤10mS 1500VAC 100M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR-210B Miniture Size Work Instructions LED / Net Weight 56g 30g Switching Output Zero cross Bidirectional SCR Application: Have load over current or short-circuit protection. It provides a reliable guarantee for some machines which is easy to short circuit. Input CircuitInput Circuit Control Voltage Control Current DC10-18V,DC20-28V ≤12mA Output CircuitOutput Circuit Load Voltage Range On-state Voltage On-off Time Dielectric Strength General DataGeneral Data 24-380VAC ≤1.5V ≤10mS Insulation Resistance Ambient Temperature Mounting Methods 2000VAC 500M 500VDCΩ@ -20~+70℃ PCB or Bolt Fixing SSR-40DA-S Installation DemensionsInstallation Demensions Special Functions Over-current Protection DC4-32V DC6-12mA 24-380VAC ≤1.5V ≤10mS 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR-F-25/40DA Built-in Fast Fuse Work Instructions LED LED Net Weight 157g 118g Parameters Parameters Load Current 10A,20A Off-state Leakage Current ≤4mA 40A ≤4mA Load Current 25A,40A 05 06 Single Phase AC Solid State Relay
  7. 7. 07 SSR Switching Output Load Current Load Voltage Monitoring Zero cross Bidirectional SCR 10A-90A 24-380VAC Output status Input CircuitInput Circuit Control Voltage Control Current DC3-32V DC6-12mA Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage On-off Time Dielectric Strength General DataGeneral Data 24-380VAC ≤4mA 10A,15A,25A,40A,60A,75A,90A ≤1.5V ≤10mS Insulation Resistance Ambient Temperature Mounting Methods 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR SSR-(10-90)DA Installation DemensionsInstallation Demensions Special Functions / DC4-32V DC6-12mA 24-380VAC ≤4mA ≤1.5V ≤10mS 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR-(10-90)DA Imported SCR Work Instructions LED LED Net Weight 105g 110g Parameters Load Current 10A,15A,25A,40A,60A,75A,90A Type-selection Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan SSR-10DA SSR-15DA SSR-25DA SSR-40DA SSR-60DA 220VAC 220VAC 220VAC 220VAC 220VAC <5A <7.5A B-50 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) Installation Demensions 47(mm) 47(mm) SSR-75DA 220VAC 80X80(mm) SSR-90DA 220VAC 80X80(mm) 08 Switching Output Load Current Load Voltage Monitoring Zero cross Bidirectional SCR 10A-90A 90-480VAC Output status Input CircuitInput Circuit Control Voltage Control Current DC3-32V DC6-12mA Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage On-off Time Dielectric Strength General DataGeneral Data 90-480VAC ≤4mA 10A,15A,25A,40A,60A,75A,90A ≤1.5V ≤10mS Insulation Resistance Ambient Temperature Mounting Methods 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR-(10-90)DA-H Installation DemensionsInstallation Demensions Special Functions High Voltage SCR DC4-32V DC6-12mA 90-480VAC ≤4mA ≤1.5V ≤10mS 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR-(10-90)DA-H Imported High Voltage SCR Work Instructions LED LED Net Weight 105g 110g Parameters Load Current 10A,15A,25A,40A,60A,75A,90A Installation Demensions 47(mm) 47(mm) <12.5A <20A <30A <37A <41A <1.1KW <1.6KW <2.7KW <4.4KW <6.6KW <8.1KW <9.0KW B-50 A-50 A-50,C-55 C-55 C-55,E-50 C-55,E-50 Type-selection Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan SSR-10DA-H SSR-15DA-H SSR-25DA-H SSR-40DA-H SSR-60DA-H 220/380VAC <5A <7.5A B-50 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) SSR-75DA-H 80X80(mm) SSR-90DA-H 80X80(mm) <12.5A <20A <30A <37A <41A <1.1KW <1.6KW <2.7KW <4.4KW <6.6KW <8.1KW <9.0KW B-50 A-50 A-50,C-55 C-55 C-55,E-50 C-55,E-50 220/380VAC 220/380VAC 220/380VAC 220/380VAC 220/380VAC 220/380VAC Single Phase AC Solid State RelaySingle Phase AC Solid State Relay
  8. 8. 09 SSR Switching Output Load Current Load Voltage Monitoring Zero cross Two anti-paralleled s phase SCR 25A-120A 24-380VAC/90-660VAC Output status ingle s S s S Input CircuitInput Circuit Control Voltage Control Current DC4-32V DC6-12mA Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage On-off Time Dielectric Strength General DataGeneral Data 24-380VAC ≤4mA 15A,25A,40A,60A,75A,90A,120A ≤1.5V ≤10mS Insulation Resistance Ambient Temperature Mounting Methods 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR SSR-(15-120)DA Installation DemensionsInstallation Demensions Special Functions Enhanced SCR DC4-32V DC6-12mA 90-660VAC ≤4mA ≤1.5V ≤10mS 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR-(15-120)DA-H High Voltage Enhaced SCR Work Instructions LED LED Net Weight 120g 120g Parameters Load Current 15A,25A,40A,60A,75A,90A,120A Type-selection Mode:Load Voltage Using Current Using Power Reference Radiator SSR-10DA: SSR-25DA: SSR-40DA: SSR-60DA: SSR-75DA: 220VAC 220VAC 220VAC 220VAC 220VAC <6A <15A Installation Demensions 47(mm) 47(mm) SSR-90DA: 220VAC SSR-120DA: 220VAC 10 Switching Output Load Current Control Voltage Load Voltage Monitoring Zero cross Bidirectional SCR 10A-90A 80-250VAC 90-480VAC Output status Input CircuitInput Circuit Control Voltage Control Current AC80-250V ≤2mA Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage On-off Time Dielectric Strength General DataGeneral Data 24-380VAC ≤4mA 10A,15A,25A,40A,60A,75A,90A ≤1.5V ≤10mS Insulation Resistance Ambient Temperature Mounting Methods 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR-(10-90)AA Installation DemensionsInstallation Demensions Special Functions High Voltage SCR ≤4mA ≤1.5V ≤10mS 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR-(10-90)AA Imported High Voltage SCR Work Instructions LED LED Net Weight 105g 110g Parameters Load Current 10A,15A,25A,40A,60A,75A,90A Installation Demensions 47(mm) 47(mm) <24A <36A <45A <54A <70A <1.3KW <3.3KW <5.2KW <7.9KW <9.9KW <11.8KW <15.4KW C-110 C-110,E-110 Type-selection Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan SSR-10AA SSR-15AA SSR-25AA SSR-40AA SSR-60AA 220VAC <5A <7.5A B-50 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) SSR-60AA 80X80(mm) SSR-60AA 80X80(mm) <12.5A <20A <30A <37A <41A <1.1KW <1.6KW <2.7KW <4.4KW <6.6KW <8.1KW <9.0KW B-50 A-50 A-50,C-55 C-55 C-55,E-50 C-55,E-50 220VAC 220VAC 220VAC 220VAC 220VAC 220VAC Mode:Load Voltage SSR-10DA-H: SSR-25DA-H: SSR-40DA-H: SSR-60DA-H: SSR-75DA-H: 220/380VAC 220/380VAC 220/380VAC 220/380VAC 220/380VAC SSR-90DA-H: 220/380VAC SSR-120DA-H: 220/380VAC Reference Fan C-55,E-50 A-50 C-55 C-55,C-110 B-50 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) AC80-250V ≤2mA 24-380VAC Single Phase AC Solid State Relay Single Phase AC Solid State Relay
  9. 9. 11 SSR Input CircuitInput Circuit Control Voltage Control Current Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage On-off Time Dielectric Strength General DataGeneral Data 90-480VAC ≤4mA 10A,15A,25A,40A,60A,75A,90A ≤1.5V ≤10mS Insulation Resistance Ambient Temperature Mounting Methods 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR SSR-(10-90)AA-H Installation DemensionsInstallation Demensions Special Functions High Voltage SCR 90-660VAC ≤4mA ≤1.5V ≤10mS 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR-(15-120)AA-H High Voltage Enhaced SCR Work Instructions LED LED Net Weight 105g 120g Parameters Load Current 15A,25A,40A,60A,75A,90A,120A Type-selection Mode Using Current Using Power Reference Radiator Installation Demensions 47(mm) 47(mm) 12 Switching Input Output Control Voltage Load Voltage Monitoring Zero cross One or two input Two Output 4-32VAC 24-380VAC Output status Input CircuitInput Circuit Control Voltage Control Current AC80-250V DC12-32mA Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage On-off Time Dielectric Strength General DataGeneral Data 24-380VAC ≤4mA 10A,15A,25A,40A ≤1.5V ≤10mS Insulation Resistance Ambient Temperature Mounting Methods 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR2-(10-40)DA Installation DemensionsInstallation Demensions Special Functions One Input, Two Output ≤4mA ≤1.5V ≤10mS 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR-(10-40)DA-2K Two Input, Two Output Work Instructions LED LED Net Weight 270g 270g Parameters Load Current 10A,15A,25A,40A Installation Demensions 70(mm) 70(mm) Type-selection Mode Load Voltage Using Current Using Power Reference Fan SSR2-10DA/SSR2-10DA-2K 220VAC <5AX2 <6.5AX2 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) <8AX2 <8AX2 <1.1KWX2 <1.4KWX2 <1.7KWX2 <1.7KWX2 220VAC 220VAC 220VAC Load Voltage Reference Fan AC80-250V DC12-32mA 24-380VAC Switching Output Load Current Control Voltage Load Voltage Monitoring Zero cross Bidirectional SCR/Two anti-paralleled single phase SCR 10A-90A 80-250VAC 90-480VAC/ 90-660VAC Output status AC80-250V ≤2mA AC80-250V ≤2mA SSR-(10A-90A)AA-H SSR-(15A-120A)AA-H 220/380VAC 220/380VAC Single Phase AC Solid State RelaySingle Phase AC Solid State Relay SSR2-15DA/SSR2-15DA-2K SSR2-20DA/SSR2-20DA-2K SSR2-40DA/SSR2-40DA-2K Please refer Page 8,AA is identified as DA Please refer Page 9,AA is identified as DA
  10. 10. 13 SSR Industry Solid State Relay Switching Output Load Voltage Monitoring Withstand Voltage Zero cross Two anti-paralleled Single phase SCR 24-440VAC Output status 2500VAC S Input CircuitInput Circuit Control Voltage Control Current DC3-32V DC7-12mA Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage On-off Time Dielectric Strength General DataGeneral Data 24-440VAC ≤4mA 10A,15A,25A,40A,60A,75A,90A ≤1.5V ≤10mS Insulation Resistance Ambient Temperature Mounting Methods 2500VAC 1000M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR SSR-60DA Installation DemensionsInstallation Demensions Special Functions Very Good Overload Capacity DC3-32V DC7-12mA 24-440VAC ≤4mA ≤1.5V ≤10mS 2500VAC 1000M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR-80/100/120DA Work Instructions LED LED Net Weight 120g 145g Parameters Load Current 10A,15A,25A,40A,60A,75A,90A Installation Demensions 80(mm) 80(mm) 14 Single Phase AC Solid State RelaySingle Phase AC Solid State Relay Very Good Overload Capacity Type-selection Mode Load Voltage Using Current Using Power Reference Fan GYSSR-60DA 220/380VAC <36A <48A 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) <60A <72A <7.9KW <10.5KW <13.2KW <15.8KW GYSSR-80DA GYSSR-100DA GYSSR-120DA 220/380VAC 220/380VAC 220/380VAC Reference Radiator L-150 for three sets L-150 for three sets L-150 for three sets L-150 for three sets Industry Solid State Relay Switching Output Load Voltage Monitoring Withstand Voltage Zero cross Two anti-paralleled Single phase SCR 24-440VAC Output status 2500VAC S Input CircuitInput Circuit Control Voltage Control Current DC3-32V DC7-12mA Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage On-off Time Dielectric Strength General DataGeneral Data 24-440VAC ≤4mA 150A,200A,250A,300A ≤1.5V ≤10mS Insulation Resistance Ambient Temperature Mounting Methods 2500VAC 1000M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR-150/200/250/300DA Installation DemensionsInstallation Demensions Special Functions Very Good Overload Capacity DC3-32V DC7-12mA 24-440VAC ≤4mA ≤1.5V ≤10mS 2500VAC 1000M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR-350DA Work Instructions LED LED Net Weight 230g 560g Parameters Load Current 350A Installation Demensions 80(mm) 92X38(mm) Very Good Overload Capacity Type-selection Mode Load Voltage Using Current Using Power Reference Fan GYSSR-150DA 220/380VAC <85A <100A 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) <125A <150A <18.7KW <22KW <27.5KW <33KW GYSSR-200DA GYSSR-250DA GYSSR-300DA 220/380VAC 220/380VAC 220/380VAC Reference Radiator L-200 for three sets L-200 for three sets L-250 for three sets L-300 for three sets 175-250VAC ~ ~ 80X80(mm)<175A <38.5KWGYSSR-350DA 220/380VAC L-400 for three sets
  11. 11. 15 Switching Output Load Current Load Voltage Monitoring Zero cross 10A-90A 24-380VAC/90-480VAC Output status Bidirectional SCR Input CircuitInput Circuit Control Voltage Control Current DC4-32V DC12-32mA Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage On-off Time Dielectric Strength General DataGeneral Data 24-380VAC ≤10mA 10A,15A,25A,40A,60A,75A,90A ≤1.5V ≤10mS Insulation Resistance Ambient Temperature Mounting Methods 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR SSR3-(10-90)DA Installation DemensionsInstallation Demensions Special Functions / DC4-32V DC12-32mA 90-480VAC ≤10mA ≤1.5V ≤10mS 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR3-(10-90)DA-H High Voltage SCR Work Instructions LED LED Net Weight 260g 260g Parameters Load Current 10A,15A,25A,40A,60A,75A,90A Type-selection Mode Using Current Using Power Reference Radiator SSR3-10DA/SSR3-10DA-H <5AX3 <12AX3 Installation Demensions 90X48(mm) 90X48(mm) <20AX3 <30AX3 <37AX3 <41AX3 <1.1KWX3 <2.7KWX3 <4.4KWX3 <6.6KWX3 <8.1KWX3 <9KWX3 L-150 Load Voltage Reference Fan C-110 G-80,D-120 C-110 E-110 G-80 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) Three Phase AC Solid State Relay 380VAC SSR3-25DA/SSR3-25DA-H SSR3-40DA/SSR3-40DA-H SSR3-60DA/SSR3-60DA-H SSR3-75DA/SSR3-75DA-H SSR3-90DA/SSR3-90DA-H 380VAC 380VAC 380VAC 380VAC 380VAC 16 Switching Output Load Current Load Voltage Monitoring Zero cross 10A-90A 24-380VAC/90-480VAC Output status Bidirectional SCR SSRThree Phase AC Solid State Relay Note:For SSR3-DA,the load adopts Y-connection, and the center of Y should be connected to neutralline. -H can l or not. For SSR3-DA ,the load adopts Y-connection, and the center of Y be connected to neutra line Input CircuitInput Circuit Control Voltage Control Current AC80-250V ≤12mA Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage On-off Time Dielectric Strength General DataGeneral Data 24-380VAC ≤10mA 10A,15A,25A,40A,60A,75A,90A ≤1.5V ≤10mS Insulation Resistance Ambient Temperature Mounting Methods 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR3-(10-90)AA Installation DemensionsInstallation Demensions Special Functions / AC80-250V ≤12mA 90-480VAC ≤10mA ≤1.5V ≤10mS 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR3-(10-90)AA-H High Voltage SCR Work Instructions LED LED Net Weight 260g 260g Parameters Load Current 10A,15A,25A,40A,60A,75A,90A Type-selection Mode Using Current Using Power Reference Radiator SSR3-10AA/SSR3-10AA-H <5AX3 <12AX3 Installation Demensions 90X48(mm) 90X48(mm) <20AX3 <30AX3 <37AX3 <41AX3 <1.1KWX3 <2.7KWX3 <4.4KWX3 <6.6KWX3 <8.1KWX3 <9KWX3 L-150 Load Voltage Reference Fan C-110 G-80,D-120 C-110 E-110 G-80 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) 380VAC SSR3-25AA/SSR3-25AA-H SSR3-40AA/SSR3-40AA-H SSR3-60AA/SSR3-60AA-H SSR3-75AA/SSR3-75AA-H SSR3-90AA/SSR3-90AA-H 380VAC 380VAC 380VAC 380VAC 380VAC Note:For SSR3-AA,the load adopts Y-connection, and the center of Y should be connected to neutralline. A -H can l or not. For SSR3- A ,the load adopts Y-connection, and the center of Y be connected to neutra line
  12. 12. 17 Switching Output Load Current Applied for Monitoring Zero cross 10A-90A Inductive Load Output status Two anti-paralleled single phase SCRs Input CircuitInput Circuit Control Voltage Control Current DC4-32V DC12-32mA Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage On-off Time Dielectric Strength General DataGeneral Data 24-380VAC ≤10mA 25A,40A,60A,75A,120A ≤1.5V ≤10mS Insulation Resistance Ambient Temperature Mounting Methods 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR SCR3-(25-120)DA Installation DemensionsInstallation Demensions Special Functions Enhanced SCR DC4-32V DC12-32mA 90-660VAC ≤10mA ≤1.5V ≤10mS 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SCR3-(25-120)DA-H High Voltage EnhancedSCR Work Instructions LED LED Net Weight 440g 440g Parameters Load Current 25A,40A,60A,75A,90A,120A Type-selection Mode Using Current Using Power Reference Radiator SSR3-25DA/SSR3-25DA-H <15AX3 <24AX3 Installation Demensions 90X48(mm) 90X48(mm) <36AX3 <45AX3 <54AX3 <70AX3 <5.7KWX3 <9.1KWX3 <13.6KWX3 <17.1KWX3 <20.5KWX3 <25.4KWX3 L-150 Load Voltage Reference Fan C-110 G-80,D-120 C-110 E-110 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) Three Phase AC Solid State Relay 380VAC SSR3-40DA/SSR3-40DA-H SSR3-60DA/SSR3-60DA-H SSR3-75DA/SSR3-75DA-H SSR3-90DA/SSR3-90DA-H SSR3-120DA/SSR3-120DA-H 380VAC 380VAC 380VAC 380VAC 380VAC 18 Switching Output Load Current Load Voltage Monitoring Zero cross 10A-90A 24-380VAC/90-480VAC Output status Bidirectional SCR SSRThree Phase AC Solid State Relay Note:For SSR3-DA,the load adopts Y-connection or connection, and the center of Y should be connected to neutralline. -H can l or not. For SSR3-DA ,the load adopts Y-connection or connection, and the center of Y be connectedto neutra line △- △- L-150 Type-selection Mode Using Current Using Power Reference Radiator SSR3-25AA/SSR3-25AA-H <15AX3 <24AX3 <36AX3 <45AX3 <54AX3 <70AX3 <5.7KWX3 <9.1KWX3 <13.6KWX3 <17.1KWX3 <20.5KWX3 <25.4KWX3 L-150 Load Voltage Reference Fan C-110 G-80,D-120 C-110 E-110 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) 380VAC SSR3-40AA/SSR3-40AA-H SSR3-60AA/SSR3-60AA-H SSR3-75AA/SSR3-75AA-H SSR3-90AA/SSR3-90AA-H SSR3-120AA/SSR3-120AA-H 380VAC 380VAC 380VAC 380VAC 380VAC L-150 Note:For SSR3-AA,the load adopts Y-connection or connection, and the center of Y should be connected to neutralline. -H can l or not. For SSR3-AA ,the load adopts Y-connection or connection, and the center of Y be connectedto neutra line △- △- Input CircuitInput Circuit Control Voltage Control Current AC80-250V ≤12mA Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage On-off Time Dielectric Strength General DataGeneral Data 24-380VAC ≤10mA 25A,40A,60A,75A,120A ≤1.5V ≤10mS Insulation Resistance Ambient Temperature Mounting Methods 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SCR3-(25-120)AA Installation DemensionsInstallation Demensions Special Functions Enhanced SCR DC80-250V ≤12mA 90-660VAC ≤10mA ≤1.5V ≤10mS 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SCR3-(25-120)AA-H High Voltage Enhanced SCR Work Instructions LED LED Net Weight 440g 440g Parameters Load Current 25A,40A,60A,75A,90A,120A Installation Demensions 90X48(mm) 90X48(mm)
  13. 13. SSRThree Phase AC Solid State Relay SSRThree Phase AC Motor Reverse Module Temperature Controller Features High Current, the rane of load current is wide, and with raditor and fan Auto-protection for over temperature,if over 50 , the fan will be started, and if over 70 ,the circuit will be cut Input voltage range suitable for around the world ℃ ℃ Control system, power device and auxiliary power integration High precision, temperature controlled accurately Technical DataTechnical Data Rated Current Load Voltage Control Voltage Control Current Mounting Methods 90A,120A,150A,200A,250A,300A,350A,400A,500A,600A 380VAC 4-32VDC DC20-95mA Bolt Fixing SET PV SV ALM1 ALM2ONAT OFF 《 《 《 R XMTA-2000 Connection ExampleConnection Example Type-selection Mode Load Voltage Using Current Using Power Reference Fan ZHSSR3-90DA 220VAC <7.5A <12.5A 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) <20A <37A <1.6KW <2.7KW <4.4KW <8.1KW 220VAC 220VAC 220VAC Reference Radiator G-80,D-120 80X80(mm)<40A <8.8KW220VAC G-80,D-120 C-110,D-120 C-110 C-110,E-110 Features Control voltage of 10-30VDC is wide range. Two LED tube display motor rotating direction. This module have a starting the electricity protection,no surge impact,strong anti-interference ability. This module have interlocking reverse control circuit to effectively prevent reverse SCR conductting simultaneously. Technical DataTechnical Data Load Power Load Voltage Control Voltage Control Current On-off Time Weight 2KW,3KW 380VAC 10-30VDC 10-30mA ≥300mS 520g Connection ExampleConnection Example FUSE Type-selection Mode Load Voltage Using Current Using Power Reference Fan TSR-2KDA-H/ZF 380VAC Three phase <5.3A 80X80(mm) 80X80(mm)380VAC Reference Radiator G-80,D-120 ZHSSR3-(90-600)DA TSR3-2/3KDA-H/ZF Positive Rotate Instruction Negative Rotate Instruction G-80,D-120 + - ~ ~ + - ~ ~ + - ~ ~ 70℃ 70℃ 50℃ 220VAC + - A B C 19 20 ZHSSR3-1200DA ZHSSR3-150DA ZHSSR3-200DA ZHSSR3-250DA 80X80(mm) 80X80(mm) <20A <37A <4.4KW <8.1KW 220VAC 220VAC 80X80(mm)<40A <8.8KW220VAC C-110,D-120 C-110 C-110,E-110 ZHSSR3-150DA ZHSSR3-200DA ZHSSR3-250DA FUSE FUSE Rv Rv Rv ++ - Control Voltage 10-30VDC Positive Rotate Negative Rotate A B C TSR-3KDA-H/ZF Three phase <7.9A Three phase <2KW Three phase <3KW
  14. 14. 21 SSR DC Motor Module Input Output Mounting Application 5 inputs or 8 outputs 5 outputs or 8 outputs C45 rail 24V solenoid valve Input CircuitInput Circuit Control Voltage Control Current DC24V Com-anode or com-cathode ≤2mA Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage On-off Time Dielectric Strength General DataGeneral Data ≤4mA 5AX5 ≤1.5V ≤10mS Insulation Resistance Ambient Temperature Mounting Methods 2000VAC 500M 500VDCΩ@ -20~+70℃ C45 Rail SSR ST5-5DD Special Functions 5 Inputs, 5 Outputs ST8-5DD Work Instructions LED Net Weight 60g Parameters Load Current Single Phase DC Motor ModuleSingle Phase DC Motor Module 8 Inputs, 8 Outputs DC24V 22 DC Motor Module Application Widely used for textile machine, chemical machinery, food machine and the other occasion which need control on-off state or stepless speed regulation for DC motor. Input CircuitInput Circuit Control Voltage Control Current DC3-32V DC2-15mA Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage On-off Time Dielectric Strength General DataGeneral Data ≤4mA 10A,30A,75A ≤1.5V ≤10mS Insulation Resistance Ambient Temperature Mounting Methods 1500VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing SSR-10/30/75DD Installation DemensionsInstallation Demensions Special Functions Switch for DC Motor DC0-5V DC4-20mA DC0-24V 1500VAC 100M 500VDCΩ@ -20~+70℃ Bolt Fixing DTS-10/25/40DD Work Instructions LED Net Weight 105g 145g Parameters Load Current 10A,25A,40A Installation Demensions 47(mm) 80(mm) Speeding Regulator for DC Motor DC5-60V,5-300VDC Voltage Bias Current Bias / DC12V DTS-10/25/40A-24V DiagramDTS-10/25/40A-24V Diagram / ≤20mA / / / / Vb voltage bias +5VDC Red Orange Yellow Green Blue 4-20mA,0-5V + - phaseshifttriggercircuit 3 4 1 Load mains locking terminal + 10K/2W Potentiometer + - DC0-24V 0 1 2 3 4 5 (V) VIN VOUT (V) 12 24 DC24V Com-anode or com-cathode ≤2mA ≤4mA 5AX5 ≤1.5V ≤10mS 2000VAC 500M 500VDCΩ@ -20~+70℃ C45 Rail LED 80g DC24V Connection DiagramConnection Diagram
  15. 15. SSR Manual Voltage Regulator Output Control Mode Load Voltage Bidirectional SCR External Potentiometer to manual adjust voltage 24-380VAC S Input CircuitInput Circuit Control Mode 500K Potentiometer @220VΩ Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage On-off Time Dielectric Strength General DataGeneral Data 24-380VAC ≤4mA 10A,15A,25A,40A,60A,75A,90A ≤1.5V Insulation Resistance Ambient Temperature Mounting Methods 2000VAC 500M 500VDCΩ@ -20~+70℃ PCB or Bolt Fixing SSRSolid State Voltage Regulator SSR-(10-90)VA Installation DemensionsInstallation Demensions Special Functions 24-380VAC ≤4mA ≤1.5V 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing Work Instructions / Net Weight 105g 110g Parameters Load Current 23 24 Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan SSR-10VA SSR-15VA SSR-25VA SSR-40VA SSR-60VA 220VAC 220VAC 220VAC 220VAC 220VAC <5A <7.5A B-50 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) SSR-75VA 220VAC 80X80(mm) SSR-90VA 220VAC 80X80(mm) <12.5A <20A <30A <37A <41A <1.1KW <1.6KW <2.7KW <4.4KW <6.6KW <8.1KW <9.0KW B-50 A-50 A-50,C-55 C-55 C-55,E-50 C-55,E-50 10A,15A,25A,40A,60A,75A,90A / / / SSR-(10-90)VA / Imported SCR Input CircuitInput Circuit Control Mode 500K @220V 1M @380VΩ Ω Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage On-off Time Dielectric Strength General DataGeneral Data 90-480VAC ≤4mA 10A,15A,25A,40A,60A,75A,90A ≤1.5V Insulation Resistance Ambient Temperature Mounting Methods 2000VAC 500M 500VDCΩ@ -20~+70℃ PCB or Bolt Fixing SSR-(10-90)VA-H Special Functions 90-480VAC ≤4mA ≤1.5V 2000VAC 500M 500VDCΩ@ -20~+70℃ Bolt Fixing Work Instructions / Net Weight 105g 120g Parameters Load Current 15A,25A,40A,60A,75A,120A / / / SSR-(10-90)VA-H High Voltage Enhanced SCREnhanced SCR Manual Voltage Regulator Output Control Mode Load Voltage Two anti-paralleled single phase SCR External Potentiometer to manual adjust voltage 90-480VAC S S S S 500K Potentiometer @220VΩ 500K @220V 1M @380VΩ Ω Type-selection Mode Using Current Using Power Reference Radiator Load Voltage Reference Fan SSR-(10A-90A)VA-H SSR-(15A-120A)VA-H 220/380VAC 220/380VAC Solid State Voltage Regulator Please refer Page 8,AA is identified as DA Please refer Page 9,AA is identified as DA
  16. 16. Output Control Mode Load Voltage Manual Voltage Regulator Board Bidirectional SCR Built-in potentiometer to manual adjust voltage 24-250VAC S Input CircuitInput Circuit Control Mode Potentiometer:500K 2WΩ/ Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage On-off Time Dielectric Strength General DataGeneral Data 24-250VAC ≤4mA 16A ≤1.5V Insulation Resistance Ambient Temperature Mounting Methods 2000VAC 500M 500VDCΩ@ -20~+70℃ SSR SSR-16VA-A Output Voltage WaveformOutput Voltage Waveform Special Functions 24-250VAC ≤4mA ≤1.5V 2000VAC 500M 500VDCΩ@ -20~+70℃ Work Instructions / Net Weight 72g 72g Parameters Load Current 25 16A / / / SSR-16VA-B Output Voltage is 0V once startupOutput Voltage is 0V once startup Output Voltage is 24V once startupOutput Voltage is 24V once startup Potentiometer:500K 2WΩ/ 0 44 88 132 176 220 (V) VOUT VIN (V) 500KΩ250KΩ 0 44 88 132 176 220 (V) VOUT VIN (V) 500KΩ250KΩ Note:These two products is a voltage regulator board plus upper panel, you can customize upper panel according to your preference. Manual Voltage Regulator Integrated design,small size, simple intallation and wiring connection. It widely used for room lighting dimming, environment temperature control, electrical switchgear cubicle and the other automation control fields. Input CircuitInput Circuit Control Mode Potentiometer:500K 2WΩ/ Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage On-off Time Dielectric Strength General DataGeneral Data 24-380VAC ≤4mA 10A,15A ≤1.5V Insulation Resistance Ambient Temperature Mounting Methods 2000VAC 500M 500VDCΩ@ -20~+70℃ SSR SSR-10/15VA Installation DemensionsInstallation Demensions Special Functions 24-380VAC ≤4mA ≤1.5V 2000VAC 500M 500VDCΩ@ -20~+70℃ Work Instructions / Net Weight 125g 50g Parameters Load Current 26 15A / / / SSR-15VA Integrated DesignIntegrated Design Room Lighting DimmingRoom Lighting Dimming Potentiometer:500K 2WΩ/ Note:Manual voltage regulator for room lighting dimming is a voltage regulator board plus upper panel, you can customize upper panel according to your preference. Suken Mounting Suken Mounting Suken Mounting Suken Mounting Single Phase AC Solid State RelaySingle Phase AC Solid State Relay Solid State Voltage Regulator Single Phase AC Solid State RelaySingle Phase AC Solid State Relay Solid State Voltage Regulator
  17. 17. Random Solid State Relay External pulse signal, this module applied with our patented products ZKG-I and DPC-I can be used for temperature control of forming machine or other resistive load.We have hold very big marketing share in China and the other nation, and will be more and more. Input CircuitInput Circuit Control Mode Temperature controller,voltage regulator Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage Dielectric Strength General DataGeneral Data 175-250VAC ≤4mA 10A,15A,25A,40A,60A,75A,90A ≤1.5V Insulation Resistance Ambient Temperature Mounting Methods 2000VAC 500M 500VDCΩ@ -20~+70℃ SSR SSR-(10-90)DV Output Voltage WaveformOutput Voltage Waveform Special Functions Net Weight 105g Parameters Load Current 27 Very Good Stabilizing Voltage FunctionVery Good Stabilizing Voltage Function Suken Mounting Solid State Voltage Regulator Random Solid State Relay Rapid response,when the effective control signal is applied across input, the load of SSR-DA-P will be conducted at once.SSR-DA-P can control shift phase pulse to adjust load voltage convinently, which be used for temperature regulation,adjusting luminance and the other resistive load or inductive load. Input CircuitInput Circuit Control Mode Temperature controller,voltage regulator Output CircuitOutput Circuit Load Voltage Range Off-state Leakage Current On-state Voltage Dielectric Strength General DataGeneral Data 175-250VAC ≤4mA 10A,15A,25A,40A,60A,75A,90A ≤1.5V Insulation Resistance Ambient Temperature Mounting Methods 2000VAC 500M 500VDCΩ@ -20~+70℃ SSR SSR-25DV Output Voltage WaveformOutput Voltage Waveform Special Functions Net Weight 105g Parameters Load Current 28 Very Good Stabilizing Voltage FunctionVery Good Stabilizing Voltage Function Suken Mounting Solid State Voltage Regulator 《 PV SV SCR VOLTAGE REGULATORSCR VOLTAGE REGULATOR 《 P ZKG-I 1 2 34 24~380VAC Solid State Relay SSR-25DV 25A INPUT ~~ T1G R G T N L LOAD FUSE Power AC220V L N 1 2 34 24~380VAC Solid State Relay SSR-40DA-P 40A INPUT 4~8VDC ~~ +_ R LOAD FUSE Power AC24-380V SSR-DA-P Series(Temperature controller control output%)SSR-DA-P Series(Temperature controller control output%) SET PV SV ALM1 ALM2ONAT OFF 《 《 《R XMT-2000 220VAC Thermocouple + - Voltage Pulse Output L N
  18. 18. SSR 29 SSRSingle Phase SCR Voltage Regulator Application Output Voltage: Forming machine,lamp,temperature Regulation,industrial furnace,oven, electrical switchgear cubicle and the other automation control fields. 0-220V/220-0V s Input CircuitInput Circuit Control Mode 0-5V,4-20mA,10K/2W potentiometer Output CircuitOutput Circuit Load Voltage Range Dielectric Strength General DataGeneral Data A:220-0VAC B:0-220VAC 10A,15A,25A,40A Insulation Resistance Ambient Temperature Mounting Methods 2000VAC 500M 500VDCΩ@ -20~+70℃ SSR-10/25/40LA-A/B Output Voltage WaveformOutput Voltage Waveform Special Functions 0-220VAC 2000VAC 500M 500VDCΩ@ -20~+70℃ Net Weight 115g 115g Parameters Load Current Bolt Fixing 10A,15A,25A,40A 4-20mA 4-20mA Bolt Fixing 30 Work Instructions / / SSR-10/25/40LA 0-5V,4-20mA,10K/2W potentiometer0-5V,4-20mA,10K/2W potentiometer Voltage Bias Current Bias A:DC5V B:DC12V ≤30mADC / / Off-state Leakage Current On-state Voltage ≤4mA ≤1.5V / / Single Phase SCR Voltage Regulator Summary Grids Voltage Output Wide Pulse Output Voltage Uoff 2.5V Uon 5V 0.5 1 Uoff:0.7 0.2V Uon:4.3 0.2V Ucon Pulse Duty Factor Single phase SCR voltage regulator includes synchronous phase detecting circuit, sawtooth wave circuit, input control regulating circuit, reference circuit, phase shift compare circuit,output trigger circuit, and stabilized voltage supply which provides power to these circuits , etc. When control voltage is changed from low to high, in the inner of this module will generate triggering pulse between 180 and 0 relative to network voltage, after photoelectric isolation,then A and G output terminal can trigger corresponding SCR to realize shift phase voltage regulation. Ultra small and thin,adopt SMT technics. screw hold-down connection and bolt fixing mounting,very easy to use. Adopt photoelectric isolation, you can manually control voltage by potentiometer or automatically by voltage signal and current signal. The trigger adopts single wide pulse trigger mode, which is suitable for inductive or resistive load. LED indication for working state Built-in RC absorption circuit Features Waveform DiagramWaveform Diagram About working waveform of single phase SCR voltage regualtor,we take 0-5V input as an example.When control voltage is changed from 0V to 5V, the module will generate triggering pulse between 180 and 0 relative to network voltage, then this triggering pulse make us get different output voltage waveform. 0-Uoff is shutoff area,there is no ouput in main circuit. Uoff-Uon:basic linear area,load voltage increased linearly with control signal. Uon-5V:fully conducting state, load voltage is grids voltage.
  19. 19. SSRSingle Phase SCR Voltage Regulator SSRSingle Phase SCR Voltage Regulator Temperature Controller L N 220VAC Features Very-hot sale Products,low cost but high qualtiy The new modular design meet IP protection stardards, CE certification. Input voltage range suitable for around the world Modularized, high voltage resistant, more safe and reliable Control system, power device and auxiliary power integration High precision, temperature controlled accurately Technical DataTechnical Data Rated Current Operation Frequency Rated Voltage Output Mode Control Signal Use Environment 15A,25A,40A,75A,90A 50Hz/60Hz Single phase 175-265VAC Phase Output 4-20mA,0-5V,0-10V,2-10K Potentiometer@0-5VΩ Less than 45 ,humidity less than 90%RH℃ SET PV SV ALM1 ALM2ONAT OFF 《 《 《 R XMTA-2000 Connection ExampleConnection Example 4-20mA,0-5VD,0-10VDC Temperature sensor Single PhaseSingle Phase SCR Voltage RegulatorSCR Voltage Regulator SCR-75LA 4-20mA INPUT 0-5V INPUT0-5V INPUT IN 220VACIN 220VAC OUT 175-265VAC +5V+5V CON COM FUSE LOAD 31 Type-selection Mode Load Voltage Using Current Using Power Reference Fan SCR-15LA 220VAC <7.5A <12.5A 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) <20A <37A <1.6KW <2.7KW <4.4KW <8.1KW SCR-25LA SCR-40LA SCR-75LA 220VAC 220VAC 220VAC Reference Radiator G-80,D-120 80X80(mm)<40A <8.8KWSCR-90LA 220VAC G-80,D-120 C-110,D-120 C-110 C-110,E-110 Temperature Controller L N 220VAC Features Enhanced Voltage Regulator, especially for inductive load. The new modular design meet IP protection stardards, CE certification. Input voltage range suitable for around the world Modularized, high voltage resistant, more safe and reliable Welding technique, good quality and long service life High precision, temperature controlled accurately Vacuum Technical DataTechnical Data Rated Current Operation Frequency Rated Voltage Output Mode Control Signal Use Environment 25A,40A,75A,90A 120A, 50Hz/60Hz Single phase 175-265VAC Phase Output 4-20mA,0-5V,0-10V Less than 45 ,humidity less than 90%RH℃ SET PV SV ALM1 ALM2ONAT OFF 《 《 《 R XMTA-2000 Connection ExampleConnection Example 4-20mA 0-5VD 0-10VDC 4-20mA 0-5VD 0-10VDC Temperature Sensor FUSE LOAD Type-selection Mode Load Voltage Using Current Using Power Reference Fan SCR-25LA-II 220VAC <15A <24A 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) <45A <52A <3.3KW <5.2KW <9.9KW <11.4KW SCR-40LA-II SCR-75LA-II SCR-90LA-II 220VAC 220VAC 220VAC Reference Radiator G-80,D-120 80X80(mm)<60A <13.2KWSCR-120LA-II 220VAC C-110 C-110,E-110 SCR-(15-90)LA(Active) SCR-(25-120)LA-II ~ ~ ~ ~ INPUT Single Phase SCR Voltage Regulator Single Phase SCR Voltage Regulator SCR-75LA-II L N INPUT OUTPUT Power work instruction Load work instruction 32 C-110,D-120 L-150,E-110 - +
  20. 20. SSRSingle Phase SCR Voltage Regulator SSRSingle Phase SCR Voltage Regulator 33 Temperature Controller L N 220VAC Features Heavy current and weak current is partially completely separated, control safety High voltage and high current resistance Modularized, high voltage resistant, more safe and reliable Welding technique, good quality and long service life High precision, temperature controlled accurately Vacuum The new modular design meet IP protection stardards, CE certification. Input voltage range suitable for around the world Technical DataTechnical Data Rated Current Operation Frequency Rated Voltage Output Mode Control Signal Use Environment 25A,40A,75A,90A 120A, 50Hz/60Hz Single phase 175-265VAC Phase Output 4-20mA,0-5V,0-10V Less than 45 ,humidity less than 90%RH℃ SET PV SV ALM1 ALM2ONAT OFF 《 《 《 R XMTA-2000 Connection ExampleConnection Example 4-20mA 0-5VD 0-10VDC 4-20mA 0-5VD 0-10VDC Temperature Sensor FUSE LOAD Type-selection Mode Load Voltage Using Current Using Power Reference Fan SCR-15LA-WY 220VAC <7.5A <12.5A 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) <20A <37A <1.6KW <2.7KW <4.4KW <8.1KW SCR-25LA-WY SCR-40LA-WY SCR-75LA-WY 220VAC 220VAC 220VAC Reference Radiator G-80,D-120 80X80(mm)<40A <8.8KWSCR-90LA-WY 220VAC G-80,D-120 C-110,D-120 C-110 C-110,E-110 SCR-(25-120)LA-WY ~ ~ ~ ~ - + INPUT Single Phase SCR Voltage Regulator Single Phase SCR Voltage Regulator SCR-75LA-WY L N INPUT OUTPUT Power work instruction Load work instruction 34 Features High voltage and enhanced voltage regulator, can resist 305-456VAC The new modular design meet IP protection stardards, CE certification. Input voltage range suitable for around the world Modularized, high voltage resistant, more safe and reliable Welding technique, good quality and long service life High precision, temperature controlled accurately Vacuum Technical DataTechnical Data Rated Current Operation Frequency Rated Voltage Output Mode Control Signal Use Environment 25A,40A,75A,90A,120A 50Hz/60Hz Single phase 305-456VAC Phase Output 4-20mA,0-5V,0-10V Less than 45 ,humidity less than 90%RH℃ Connection ExampleConnection Example Type-selection Mode Load Voltage Using Current Using Power Reference Fan SCR-15LA-H 380VAC <7.5A <12.5A 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) <20A <37A <1.6KW <2.7KW <4.4KW <8.1KW SCR-25LA-H SCR-40LA-H SCR-75LA-H 380VAC 380VAC 380VAC Reference Radiator G-80,D-120 80X80(mm)<40A <8.8KWSCR-90LA-H 380VAC G-80,D-120 C-110,D-120 C-110 C-110,E-110 SCR-(25-120)LA-II Temperature Controller L L 380VAC SET PV SV ALM1 ALM2ONAT OFF 《 《 《 R XMTA-2000 4-20mA 0-5VD 0-10VDC 4-20mA 0-5VD 0-10VDC Temperature Sensor FUSE LOAD ~ ~ ~ ~ - + INPUT Single Phase SCR Voltage Regulator Single Phase SCR Voltage Regulator SCR-75LA-II L N INPUT OUTPUT Power work instruction Load work instruction - + - +
  21. 21. 35 Features Manually or automatically generate pulse DC voltage which can be stepless controlled,adjustable range is wide,output precision is high. Full isolated design,dielectric withstanding voltage is over 2000VAC This module adopts SMT technics and DCB ceramic substrate,few peripheral connection. Application:electroplating,electrowelding,DC motor,and so on. Technical DataTechnical Data Load Current Load Voltage Control Voltage Output Mode Work Instructions Weight 25A,40A,75A,90A,120A 175-265VAC DC:0-5V,4-20mA,10k 2W potentiometerΩ/ Phase Output Red Led: power supply Green Led:output voltage variation 440g Connection ExampleConnection Example Type-selection Mode Load Voltage Using Current Using Power Reference Fan SCR-15LA-ZL 220VAC <9A <15A 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) <24A <45A <1.9KW <3.3KW <5.2KW <9.9KW Reference Radiator G-80,D-120 80X80(mm)<52A <11.4KW G-80,D-120 C-110,D-120 C-110 C-110,E-110 SCR-(25-120)LA-ZLI L N 220VAC FUSE LOAD Power work instruction Load work instruction ~ ~ ~~ Voltage Regulating Rectifier Module Voltage Regulating Rectifier Module SCR-40LA-ZL ~ + - +5VCONCOM + - 0-5V,4-20mA SCR-25LA-ZL SCR-40LA-ZL SCR-75LA-ZL SCR-90LA-ZL 80X80(mm)<60A <13.2KW L-150,E-110SCR-120LA-ZL 220VAC 220VAC 220VAC 220VAC 220VAC SSRSingle Phase SCR Voltage Regulator SSRSingle Phase SCR Voltage Regulator 36 Features Protective cover to prevent electrical shock hazard. The radiator and fan make sure a very nice heat emission. High voltage and high current resistant. Modularized, high voltage resistant, more safe and reliable. Control system, power device and auxiliary power integration. High precision, temperature controlled accurately. Technical DataTechnical Data Rated Current Rated Voltage Operation Frequency Output Mode 25A,40A,75A Single Phase 220VAC 50/60Hz Phase Output Connection ExampleConnection Example AYSCR-(25-75)LA-DX Control Voltage 4-20mA, 0-5VDC, 0-10VDC Manual Adjustment:2-10K potentiometer, control signal should select 0-5VDC Ω FUFU NBF Wiring Instruction of Control Circuit 220VAC N L + -M + -M External Signal Input 4-20mA DC0-5V DC0-10V+ - NBF Uoff 10mA Uon 20mA 0.5 1 Uoff:4mA 0.5mA Adjustable Area:Uoff-Uon Uon:18-20mA + Ucon Pulse Duty Factor 4mA 1.The main circuit adopts single phase 220VAC input. 2.SCR is a product with big current, please keep in mind that terminals (R.S.T) and (U.VW) shall not be locked tightly, or SCR will be burned by terminal heating. 3.During the use of the module, you need to match proper radiator, and heat conducting silicon grease should be coated between radiator and SCR backboard. If the module power is very big, please consider wind or water cooling. 4.Please use semi-conductive fast fuse for load over current. 5.When control signal changes from low to high, AC voltage of the load can be adjustable from 0v to maximum output. The adjustable area is about 4.5-18mA, the closed area is 4-4.5mA, the wide- open area is 18-20mA. D D D D D D D D D D
  22. 22. SSRSingle Phase SCR Voltage Regulator 38 Features Protective cover to prevent electrical shock hazard. The radiator and fan make sure a very nice heat emission. Modularized, high voltage resistant, more safe and reliable. Control system, power device and auxiliary power integration built in fast fuse for over current and short-circuit protection High voltage and high current resistant. Technical DataTechnical Data Rated Current Rated Voltage Operation Frequency Output Mode 200A,250A,300A Single Phase 220VAC 50/60Hz Phase Output Connection ExampleConnection Example FUSCR-(25-75)LA-DX Control Voltage 4-20mA, 0-5VDC, 0-10VDC Manual Adjustment:2-10K potentiometer, control signal should select 0-5VDC Ω FUFU NBF Wiring Instruction of Control Circuit 220VAC N L + -M + -M External Signal Input 4-20mA DC0-5V DC0-10V+ - NBF Uoff 10mA Uon 20mA 0.5 1 Uoff:4mA 0.5mA Adjustable Area:Uoff-Uon Uon:18-20mA + Ucon Pulse Duty Factor 4mA 1.The main circuit adopts single phase 220VAC input. Auxiliary power must be synchronous with main power. 2.SCR is a product with big current, please keep in mind that terminals (R.S.T) and (U.VW) shall not be locked tightly, or SCR will be burned by terminal heating. 3.When control signal changes from low to high, AC voltage of the load can be adjustable from 0v to maximum. The adjustable area is about 4.5-18mA, the shutoff area is 4-4.5mA and the fully conducting area is 18-20mA. 4.There is a fast fuse built in SCR for over current and short-circuit protection. If the fast fuse was blown, the yellow LED was showing, right now please check the load circuit short or not or partial discharge, etc. After troubleshooting, please open the panel to replace the blown fuse with a fuse of the same rating. Please never hop up the fuse ampere. m m m m m m m m m m m m m m SSRSingle Phase SCR Voltage Regulator 37 Features Protective cover to prevent electrical shock hazard. The radiator and fan make sure a very nice heat emission. Modularized, high voltage resistant, more safe and reliable. Control system, power device and auxiliary power integration High precision, temperature controlled accurately High voltage and high current resistant. Technical DataTechnical Data Rated Current Rated Voltage Operation Frequency Output Mode 90A,120A,150A Single Phase 220VAC 50/60Hz Phase Output Connection ExampleConnection Example HNSCR-(90-150)LA-DX Control Voltage 4-20mA, 0-5VDC, 0-10VDC Manual Adjustment:2-10K potentiometer, control signal should select 0-5VDC Ω FUFU NBF Wiring Instruction of Control Circuit 220VAC N L + -M + -M External Signal Input 4-20mA DC0-5V DC0-10V+ - NBF Uoff 10mA Uon 20mA 0.5 1 Uoff:4mA 0.5mA Adjustable Area:Uoff-Uon Uon:18-20mA + Ucon Pulse Duty Factor 4mA 1.The main circuit adopts single phase 220VAC input. 2.SCR is a product with big current, please keep in mind that terminals (R.S.T) and (U.VW) shall not be locked tightly, or SCR will be burned by terminal heating. 3.During the use of the module, you need to match proper radiator, and heat conducting silicon grease should be coated between radiator and SCR backboard. If the module power is very big, please consider wind or water cooling. 4.Please use semi-conductive fast fuse for load over current. 5.When control signal changes from low to high, AC voltage of the load can be adjustable from 0v to maximum output. The adjustable area is about 4.5-18mA, the closed area is 4-4.5mA, the wide- open area is 18-20mA. D D D D D D D D D D
  23. 23. SSRSingle Phase SCR Voltage Regulator 40 SSRSingle Phase SCR Voltage Regulator 39 Patented Products for Forming Machine, Blowing Machine,Sheet Machine or Other Resistive Loads Summary Features Our products based on single-chip computer as the core are designed to adjust load voltage continuously by phase-shift trigger. Due to the use of deep voltage negative feedback, our products have exceptional stabilized voltage property, well linearity control function, and can minimize the effects of electric network fluctuation. Our products have hold a most marketing share in China and the other nation, and will become more and more. Stabilized voltage property, well linearity control function, can minimize the effects of electric network fluctuation. Small, light, clear reading and low cost Have high accuracy, good shock-resistant, good reliability. Respond quickly to change in set voltage. Have pushbutton switches which are operationally simple and reliable. Important SpecificationsImportant Specifications Adjustment Range Working Voltage Control Output Mode 0-220VAC AC220V 50Hz(the other voltage can be customized) Control SSR-DV module Control one bidirectional SCR Control one SKKT or two anti-paralleled single phase SCR Installing Mode Panel type Environment Conditons Maximum relative humidity 85%, Temperature 0-50℃ Connection DiagramConnection Diagram 《 PV SV SCR VOLTAGE REGULATORSCR VOLTAGE REGULATOR 《 P 1 2 34 24~380VAC Solid State Relay SSR-25DV 25A INPUT ~~ T1G R G T1 N L LOAD FUSE Power AC220V L N 《 PV SV SCR VOLTAGE REGULATORSCR VOLTAGE REGULATOR 《 P G T1 N L LOAD FUSE Power AC220V L N 《 PV SV SCR VOLTAGE REGULATORSCR VOLTAGE REGULATOR 《 P N L LOAD FUSE Power AC220V L N K2 G2 K1 G1 《 PV SV SCR VOLTAGE REGULATORSCR VOLTAGE REGULATOR 《 P N L LOAD FUSE Power AC220V L N K2 G2 K1 G1 Fig.1 Fig.2 Fig.3 Fig.4 Safty NoticeSafty Notice 1.Please connect wire between output, feedback, power, ground wire and load according to above Fig. The phase of load must correspond with power of voltage regulator (i.e. synchronism), or it will lead to damage of voltage regulator. 2.Press up arrow or down arrow from the panel until required voltage (i.e. “SV” value), then you will find it is synchronous changing between “SV” and “PV” value. 3.If you press “P” key at any time, our SCR voltage regulator will stop output untill you press “P” key again. 4.Fig.5 and Fig.6 is integrated output,it is very convinient.But Fig.6 have full power output function SV Value PV Value V Electrify Waveform SV PV Operating Waveform 220V0V 220V 110V 110V Fig.5 Fig.6
  24. 24. SSRSingle Phase SCR Voltage Regulator 42 SSRSingle Phase SCR Voltage Regulator 41 Product Selection TableProduct Selection Table Appearance Type ZKG-I Dimensions Opening Size Load Power Control Type Connection Diagram 48x48x90 45x45 Any power will do Control SSR-DV Module Fig.1 ZKG-IIB 48x48x107 45x45 Any power will do Control a bidirectional SCR Fig.2 ZKG-IIIB 48x48x107 45x45 Any power will do Control two anti-paralleled single phase SCR or a SKKT Fig.3 Fig.4 ZKG-IIA 48x48x75 45x45 Any power will do Fig.2 ZKG-IIIA 48x48x75 45x45 Any power will do Control two anti-paralleled single phase SCR or a SKKT ZKD-IIA 72x72x120 67x67 Any power will do Control a bidirectional SCR Control a bidirectional SCR Product Selection TableProduct Selection Table Appearance Type ZKD-IIIA Dimensions Opening Size Load Power Control Type Connection Diagram 72x72x120 67x67 Any power will do ZKG-5 48x48x110 45x45 Must not be larger 500W Intergration control load directlly,but SCR can not be split Fig.5 ZKG-62 48x48x112 45x45 ZKG-64 DVC-4 48x48x75 45x45 Fig.6 ZKC-36 280x160x65 151x199.5 Any power will do Fig.1Control 36 way SSR-DV Fig.3 Fig.4 Fig.2 Must not be larger 500W Fig.5 48x48x112 45x45 Must not be larger 500W Fig.5 Intergration control load directlly,but SCR can be split Intergration control load directlly,but SCR can be split Must not be larger 1000W Intergration control load directlly,and have full power output function
  25. 25. SSRDigital Power Control Series 44 Features Intergrated output,very convinient,and buitl-in radiator,but the maximum power is 800W Be fit for forming machine, blowing machine and the other resistive load There is stabilized voltage output After start-up you can set the time of full power output Auto memory function, the stored program will never get lost External full-power manual control, you can warm up quickly Technical DataTechnical Data Working Voltage Adjustment Range Phase-shifting Angle Output Mode 150-220VAC 50/60Hz 0-99% 0-160 。 Phase Output Connection ExampleConnection Example DPC-II-M Use Environment Less than 45 ,humidity less than 85%RH℃ Remark: 1.DPC-II-M have three states,non power output(OF),full power output(HP) and set percentage power output . These three work state have auto memory function after electrifying the meter and can be circularly changed by “P” key. 2.“S1” switch is external manual switch of full power output control. When “SI” is closed, DPC-III-M output full power, except “OF” and “HP” state. This function can be optional according to practical application. 3.When multi DPC-II-M were used, DPC-II-M in the same phase can share one external control switch of full power output. Overall Dimensions Opening Size 52x52x35(mm) 46x45(mm) 1 2 34 24~380VAC Solid State Relay SSR-25DV 25A INPUT ~~ T1G R SSRDigital Power Control Series 43 Features DPC-I adopts zero-cross triggering to control power,which can be used for temperature control of forming machine, blowing machine or other resistance loads with SSR-DV There is no stabilized voltage output Have good shock-resistant, small overall dimensions, light weight, high performance-price ratio Have full power output and you can set the time of full power output Technical DataTechnical Data Working Voltage Adjustment Range Phase-shifting Angle Output Mode 150-220VAC 50/60Hz 0-99% 0-160 。 Phase Output Connection ExampleConnection Example DPC-I-M Use Environment Less than 45 ,humidity less than 85%RH℃ 99%100% 220V Output Power Load Voltage 0% Remark: 1.DPC-I have three states,non power output(OF),full power output(HP) and set percentage power output . These three work state have auto memory function after electrifying the meter and can be circularly changed by “P” key. 2.DPC-I voltage regulator and the load must be power synchronism, if not SCR will be damaged 3.You can use an external switch to control voltage regulators which are in the same phase. If they are not in the same phase, you can not do that. Overall Dimensions Opening Size 52x52x35(mm) 46x45(mm) DPC P DIGITAL POWER CONTROLDIGITAL POWER CONTROL OUT % G FP N L LOADPower AC220V L N FUSE External Switch 218V OUT F.P. N L FUSE LOAD OUT F.P. N L FUSE LOAD OUT F.P. N L FUSE LOAD OUT F.P. N L FUSE LOAD L N S1 Output Stability Coefficient 1.5%
  26. 26. SSRDigital Power Control Series 45 Features Be fit for forming machine, blowing machine and the other resistive load with our specialized solid state relay SSR-AVA There is stabilized voltage output After start-up you can set the time of full power output Auto memory function, the stored program will never get lost External full-power manual control, you can warm up quickly Technical DataTechnical Data Working Voltage Adjustment Range Phase-shifting Angle Output Mode 150-220VAC 50/60Hz 0-99% 0-160 。 Phase Output Connection ExampleConnection Example Use Environment Less than 45 ,humidity less than 85%RH℃ Remark: 1.DPC-III-M have three states,non power output(OF),full power output(HP) and set percentage power output . These three work state have auto memory function after electrifying the meter and you can be circularly changed by “P” key. 2.“S1” switch is external manual switch of full power output control. When “SI” is closed, DPC-III-M output full power, except “OF” and “HP” state. This function can be optional according to practical application. 3.When multi DPC-III-M were used, DPC-III-M in the same phase can share one external control switch of full power output. Overall Dimensions Opening Size 52x52x46(mm) 46x45(mm) Output Stability Coefficient 1.5% 1 2 34 24~380VAC Solid State Relay SSR-25AVA 25A INPUT ~~ T1G R DPC P DIGITAL POWER CONTROLDIGITAL POWER CONTROL OUT % G FP N L LOADPower AC220V L N FUSE S1 1 2 34 24~380VAC Solid State Relay SSR-25AVA 25A INPUT ~~ T1G R DPC P DIGITAL POWER CONTROLDIGITAL POWER CONTROL OUT % LOADFUSE A B C G FP N L N 1 2 34 24~380VAC Solid State Relay SSR-25AVA 25A INPUT ~~ T1G R DPC P DIGITAL POWER CONTROLDIGITAL POWER CONTROL OUT % LOADFUSE G FP N L 1 2 34 24~380VAC Solid State Relay SSR-25AVA 25A INPUT ~~ T1G R DPC P DIGITAL POWER CONTROLDIGITAL POWER CONTROL OUT % LOADFUSE G FP N L A1 B1 C1 A2 B2 C2 SCR3-LA Control ignalSControl ignalS N COM CON - + A B C N 380VAC Three Phase Features Economy three phase thyristor power regulator,enhance the product value. The new modular design meet IP protection stardards, CE certification. Input voltage range suitable for around the world Latest technology:small size, stable output power, good cooling effect. Input mode:4-20mA/0-5V/0-10V/Potentiometer Output mode: phase output Technical DataTechnical Data Rated Current Operation Frequency Rated Voltage Output Mode Control Signal Use Environment Dimension(mm) Installation Dimension(mm) 25A,40A,75A,90A,120A 50Hz/60Hz Three phase 380VAC FAN220VAC Phase Output 4-20mA/0-5V/0-10V/Potentiometer Less than 45 ,humidity less than 90%RH℃ 100X110X145(WXLXH) 90X80(WXL) SET PV SV ALM1 ALM2ONAT OFF 《 《 《 R XMTA-2000 Connection ExampleConnection Example 4-20mA 0-5VDC 0-10VDC 4-20mA 0-5VDC 0-10VDC Temperature sensor SSRThree Phase SCR Power Regulator 46 Type-selection Mode Load Voltage Maximum Using Current Maximum Using Power Reference Radiator Reference Fan SCR3-25LA SCR3-40LA SCR3-75LA SCR3-90LA SCR3-120LA 380VAC 380VAC 380VAC 380VAC 380VAC 12.5AX3 20AX3 37.5AX3 45AX3 60AX3 2.7KWX3 4.4KWX3 8.2KWX3 9.9KWX3 13.2KWX3 G-80,D-120 C-110 C-110,E-110 L-150,E-110 L-150,L-200 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) 80X80(mm) 0% 20% 40% 60% 80% 100% 4mA 20mA SCR3-LA(Economy Type)
  27. 27. Control ignalSControl ignalS - + A B C N 380VAC Three Phase Features With automatic protective function,built-in fast fuse Input voltage range suitable for around the world Vacuum welding technique,good quality and long service life Latest technology:small size, stable output power, good cooling effect. Input mode:4-20mA/0-5V/0-10V/Potentiometer Output mode: phase output Protective cover to prevent electrical shock hazard Technical DataTechnical Data Rated Current Operation Frequency Rated Voltage Output Mode Control Signal Use Environment Dimension(mm) Installation Dimension(mm) 40A,75A 50Hz/60Hz Three phase 380VAC FAN220VAC Phase Output 4-20mA/0-5V/0-10V/Potentiometer Less than 45 ,humidity less than 90%RH℃ 126X130X152(WXLXH) 116X90(WXL) SET PV SV ALM1 ALM2ONAT OFF 《 《 《 R XMTA-2000 Connection ExampleConnection Example 4-20mA 0-5VDC 0-10VDC 4-20mA 0-5VDC 0-10VDC Temperature sensor SSRThree Phase SCR Power Regulator 48 0% 20% 40% 60% 80% 100% 4mA 20mA Remark: 1.The main circuit adopts three-phase four-wire input without requirement for phase sequence. 2.For SCR is a product with a high current, please keep in mind that terminals of R,S,T and U,V,W be locked tightly, or SCR will be burned by terminals’ heating. 3.There is a fast fuse built in SCR for over current and short circuit protection.Please replace with fuse of equivalent specification when the fast fuse is burned out,and don't use the one with higher fusing ampere. 4.When Y connection is used for three-phase load,the center of Y should be connected with zero line,if not so,relative equilibrium of the three-phase is required. 5.During the use of module,when the load power is big or the radiating condition is bad,please consider wind cooling. U Control ignalSControl ignalS N COM CON - + A B C N 380VAC Three Phase Features Simple three phase four-wire thyristor power regulator,simple installation and wirre connection The new modular design meet IP protection stardards, CE certification. Input voltage range suitable for around the world Latest technology:small size, stable output power, good cooling effect. Input mode:4-20mA/0-5V/0-10V/Potentiometer Output mode: phase output Technical DataTechnical Data Rated Current Operation Frequency Rated Voltage Output Mode Control Signal Use Environment Dimension(mm) Installation Dimension(mm) 40A,75A 50Hz/60Hz Three phase 380VAC FAN220VAC Phase Output 4-20mA/0-5V/0-10V/Potentiometer Less than 45 ,humidity less than 90%RH℃ 100X140X145(WXLXH) 90X80(WXL) SET PV SV ALM1 ALM2ONAT OFF 《 《 《 R XMTA-2000 Connection ExampleConnection Example 4-20mA 0-5VDC 0-10VDC 4-20mA 0-5VDC 0-10VDC Temperature sensor SSRThree Phase SCR Power Regulator 47 0% 20% 40% 60% 80% 100% 4mA 20mA V W LINE AC380V LOAD SCR POWER REGULATOR SCR3-KW-4 Remark: 1.The main circuit adopts three-phase four-wire input without requirement for phase sequence. 2.For SCR is a product with a high current, please keep in mind that terminals of R,S,T and U,V,W be locked tightly, or SCR will be burned by terminals’ heating. 3.Module protection:please use semi-conductive fast fuse for over current protection. 4.When Y connection is used for three-phase load,the center of Y should be connected with zero line,if not,relative equilibrium of three-phase is required. 5.During use of module, when the load power is more than 15KW, it’s best to be equipped with proper radiator, and heatconducting silicon grease should be coated between radiator and SCR backboard ,and cool by wind. SCR3-KW-4(Simple Type) N COM SCR POWER REGULATOR FU FU FU MODE: MAIN SOURCE: INPUT: CURRENT: 220VAC 380VAC PHASE ANGLE ZERO CROSSING 4-20mA 1-5VDC 40A 75A 90A 120A ! N - + INPUT U V W CON +5V R S T PRSCR-LA
  28. 28. Features Technical DataTechnical Data Rated Current Operation Frequency Rated Voltage Output Mode Control Signal Use Environment Dimension(mm) Installation Dimension(mm) 75A,90A,120A 50Hz/60Hz Three phase 380VAC FAN220VAC Phase Output 4-20mA/0-5V/0-10V/Potentiometer Less than 45 ,humidity less than 90%RH℃ 75A,90A:110X230X165(WXLXH) 120A:110X280X165(WXLXH) 100X160(WXL) Connection ExampleConnection Example SSRThree Phase SCR Power Regulator 50 Features Multipurpose LED indication for working condition With automatic protective function,built-in fast fuse Input voltage range suitable for around the world Input mode:4-20mA/0-5V/0-10V/Potentiometer Linear phase shift control circuit, with good stability and high precision Modularized, high voltage resistant, more safe and reliable Adjustable for maximum and minimum output Technical DataTechnical Data Rated Current Operation Frequency Rated Voltage Output Mode Control Signal Use Environment Dimension(mm) Installation Dimension(mm) 25A,40A 50Hz/60Hz Three phase 380VAC FAN220VAC Phase Output 4-20mA/0-5V/0-10V/Potentiometer Less than 45 ,humidity less than 90%RH℃ 112X135X165(WXLXH) 101X95(WXL) Connection ExampleConnection Example SSRThree Phase SCR Power Regulator 49 Remark: 1.The main circuit adopts three-phase three-wire input without requirement for phase sequence. 2.For SCR is a product with a high current, please keep in mind that terminals of R,S,T and U,V,W be locked tightly, or SCR will be burned by terminals’ heating. 3.There is a fast fuse built in SCR for over current and short-circuit protection. If the fast fuse was blown, the yellow LED is showing, right now please check the load circuit short or not or partial discharge, etc. After troubleshooting, please open the panel to replace the blown fuse with a fuse of the same rating. Please never hop up the fuse ampere. 4.For Y connection load, the center can not be to zero line, or SCR will lose control. 5.During use of module, when the load power is big or the radiating condition is bad, please consider wind cooling AYSCR-LA J3-SCR-LA Control ignalSControl ignalS A B C 380VAC Three Phase SET PV SV ALM1 ALM2ONAT OFF 《 《 《 R XMTA-2000 4-20mA 0-5VDC 0-10VDC 4-20mA 0-5VDC 0-10VDC Temperature sensor SCR POWER REGULATOR FU FU FU MODE: MAIN SOURCE: INPUT: CURRENT: 220VAC 380VAC PHASE ANGLE ZERO CROSSING 4-20mA 1-5VDC 25A 40A 75A 90A R S T U V W UP PL IN OUT FB BIAS BIAS M + - INPUT Multipurpose LED indication for working condition With automatic protective function,built-in fast fuse Input voltage range suitable for around the world Input mode:4-20mA/0-5V/0-10V/Potentiometer Linear phase shift control circuit, with good stability and high precision Modularized, high voltage resistant, more safe and reliable Adjustable for maximum and minimum output Remark: 1.The main circuit adopts three-phase three-wire input without requirement for phase sequence. 2.For SCR is a product with a high current, please keep in mind that terminals of R,S,T and U,V,W be locked tightly, or SCR will be burned by terminals’ heating. 3.There is a fast fuse built in SCR for over current and short-circuit protection. If the fast fuse was blown, the yellow LED is showing, right now please check the load circuit short or not or partial discharge, etc. After troubleshooting, please open the panel to replace the blown fuse with a fuse of the same rating. Please never hop up the fuse ampere. 4.For Y connection load, the center can not be to zero line, or SCR will lose control.If three phase is unbalanced, you can choose my company’s three-phase four-wire products. Control ignalSControl ignalS A B C 380VAC Three Phase SET PV SV ALM1 ALM2ONAT OFF 《 《 《 R XMTA-2000 4-20mA 0-5VDC 0-10VDC 4-20mA 0-5VDC 0-10VDC Temperature sensor SCR POWER REGULATOR FU FU FU MODE: MAIN SOURCE: INPUT: CURRENT: 220VAC 380VAC PHASE ANGLE ZERO CROSSING 4-20mA 1-5VDC 25A 40A 75A 90A R S T U V W UP PL IN OUT FB BIAS BIAS M + - INPUT Power supply AC380V state Control signal input state Output state Fast fuse state or phase-missing state PL IN OUT FB BIAS BIAS M + - Control signal input 4-20mA DC0-5V DC0-10V Adjust minimum output Adjust maximum output Internal power voltage DC5V Power supply AC380V state Control signal input state Output state Fast fuse state or phase-missing state PL IN OUT FB BIAS BIAS M + - Control signal input 4-20mA DC0-5V DC0-10V Adjust minimum output Adjust maximum output Internal power voltage DC5V
  29. 29. Features Technical DataTechnical Data Rated Current Operation Frequency Rated Voltage Output Mode Control Signal Use Environment 75A 90A 120A 150A 200A 250A 50Hz/60Hz Three phase 380VAC(three-phase three-wire) Phase Output 4-20mA/0-5V/0-10V/Potentiometer Less than 45 ,humidity less than 90%RH℃ Connection ExampleConnection Example SSRThree Phase SCR Power Regulator 52 Features Multipurpose LED indication for working condition With over temperature protective function Input voltage range suitable for around the world Input mode:4-20mA/0-5V/0-10V/Potentiometer Novel structure,high efficiency,high quality Modularized, high voltage resistant, more safe and reliable Built-in fast fuse with over current protective function Technical DataTechnical Data Rated Current Operation Frequency Rated Voltage Output Mode Control Signal Use Environment Dimension(mm) Installation Dimension(mm) 40A,75A,90A 50Hz/60Hz Three phase 380VAC Phase Output 4-20mA/0-5V/0-10V/Potentiometer Less than 45 ,humidity less than 90%RH℃ 140X200X150(WXLXH) 130X170(WXL) Connection ExampleConnection Example SSRThree Phase SCR Power Regulator 51 Remark: 1.The main circuit adopts three-phase four-wire input without requirement for phase sequence. 2.For SCR is a product with a high current, please keep in mind that terminals of R,S,T and U,V,W be locked tightly, or SCR will be burned by terminals’ heating. 3.There is a fast fuse built in SCR for over current and short-circuit protection.Please replace with fuse of equivalent specification when the fast fuse is burned out,and don't use the one with higher fusing ampere. 4.When Y connection is used for three-phase load,the center of Y should be connected with zero line,if not so,relative equilibrium of the three-phase is required. HNSCR-LA HNSCR-LA-ZQ Control ignalSControl ignalS A B C 380VAC Three Phase SET PV SV ALM1 ALM2ONAT OFF 《 《 《 R XMTA-2000 4-20mA 0-5VDC 0-10VDC 4-20mA 0-5VDC 0-10VDC Temperature sensor SCR POWER REGULATOR FU FU FU MODE: MAIN SOURCE: INPUT: CURRENT: 220VAC 380VAC PHASE ANGLE ZERO CROSSING 4-20mA 1-5VDC 25A 40A 75A 90A R S T U V W UP PL IN OUT FB Auxiliary Power supply AC220V state Control signal input state Output state Fast fuse state or phase-missing state PL IN OUT FB Novel structure,high quality With over temperature protective function Multipurpose LED indication for working condition Adjustable for maximum and minimum output Applied for high power load Input voltage range suitable for around the world Input mode:4-20mA/0-5V/0-10V/Potentiometer Remark: The main circuit adopts three-phase four-wire input without requirement for phase sequence. For SCR is a product with a high current, please keep in mind that terminals of R,S,T and U,V,W be locked tightly, or SCR will be burned by terminals’ heating. When Y connection is used for three-phase load,the center of Y should be connected with zero line,if not so,relative equilibrium of the three-phase is required. When the temperature of radiator exceeds 75 °C,the modules will stop working automatically,and only the power indicating light is bright on the moment. CONTROL A 1C AC2 M + - E3 E2 E1 N Dimension(mm) WXLXH Installation Dimension(mm) 170X260X250 170X310X250 170X360X250 150X150 WXL)( 150X200(WXL) 150X250(WXL) Control ignalSControl ignalS A B C 380VAC Three Phase SET PV SV ALM1 ALM2ONAT OFF 《 《 《 R XMTA-2000 4-20mA 0-5VDC 0-10VDC 4-20mA 0-5VDC 0-10VDC Temperature sensor SCR POWER REGULATOR FU FU FU MODE: MAIN SOURCE: INPUT: CURRENT: 220VAC 380VAC PHASE ANGLE ZERO CROSSING 4-20mA 1-5VDC 25A 40A 75A 90A R S T U V W UP PL IN OUT FB Auxiliary Power supply AC220V state Control signal input state Output state Phase-missing state PL IN OUT FB CONTROL A 1C AC2 M + - E3 E2 E1 N A 1CA 1C AC2AC2 M + - E3 E2 E1 AC220V Auxiliary power TIC Input signal If you do not use potentiometer,E2 and E3 must be shorted A 1CA 1C AC2AC2 M + - E3 E2 E1 AC220V Auxiliary power TIC Input signal If you do not use potentiometer,E2 and E3 must be shorted

×