Tmr221 Esm9 Tmr231 A Production Timer Wiring Diagram

  1. 1. Production Timer System Wiring Diagram DSP253A & RYG16A CAT5 Cable ( x 3) to 120VAC DC 12VDC / 9A Symbol Technologies SYM04-1 CAT5 Cable KT485A 4-Cond Stranded Unshielded cable with connector to 2-Cond Stranded Unshielded CAT5 Cable Connections: (4 Cond) (2 Cond) 4-Cond Crossover Red + Green to Red Phone Cord Black + White to White Standard 4-Cond Phone Cord to 120VAC AC 6-Cond Crossover Phone Cord 12VAC / 20VA Amseco XF-1220 Wall Transformer NOTE: For long distances, use 18GA or larger wire for the power wires (+V ,Gnd) See the wiring code book for details on wire specifications. TMR231A TMR221ESM9 Assume that the timer requires 100ma each. Assume that the displays require 500ma each. For exact current requirements on a particular model, contact Alzatex for details. Most displays require less than 500ma to operate. NOTE: Use twisted pair for the data signals (D-,D+). Use 22ga or larger for the data signals. In noisy environments, use shielded cable for the data signals. NOTE: A good quality 4 conductor 18GA or larger cable may be used provided that the group of four wires is twisted. Surface Mount Phone Jack TMR221ESM9_TMR231A_ProductionTimer 7/17/2008 ALZATEX, Inc. www.alzatex.com

×