5898WIRELESS K-BAND DUAL TEC® MOTION SENSORHoneywell’s 5898 Wireless K-Band DUAL TEC Motion                        PIR sen...
5898WIRELESS K-BAND DUAL TEC MOTION SENSORORDERING5898             Wireless K-Band DUAL TEC Motion SensorACCESSORIES0-000-...
5898WIRELESS K-BAND DUAL TEC MOTION SENSORDETECTION PATTERNS50/15m Wide Angle Lens                                  35/11m...
5898WIRELESS K-BAND DUAL TEC MOTION SENSORSPECIFICATIONS• Detection Method                         • Mounting Height      ...
Upcoming SlideShare
Loading in …5
×

Honeywell 5898-data-sheet

1,198 views

Published on

Published in: Business, Technology
  • Be the first to comment

  • Be the first to like this

Honeywell 5898-data-sheet

  1. 1. 5898WIRELESS K-BAND DUAL TEC® MOTION SENSORHoneywell’s 5898 Wireless K-Band DUAL TEC Motion PIR sensitivity and temperature sensing can be enabled viaSensor provides superior detection and reduces the risk of local programming or from the central station. Installation isfalse alarms. The combination of PIR and K-Band easy, with no jumpers, switches or disassembly, fewermicrowave technologies enable the sensors to distinguish mounting restrictions and an automatic walk test mode thatbetween real intruders and other environmental conditions turns on the LED for ten minutes—saving installers one tripby “confirming” each other within a defined area of up the ladder for each sensor. The 5898 blends perfectlyprotection. The sleek, compact design makes it ideal for with Honeywell’s 5800 Series family of sensors to create aapplications where aesthetics and discretion are critical. seamless look in any residential or commercial environment.FEATURES• Advanced DualCore Signal – Ceiling and wall mounting brackets match sensing technologies, the look of Processing help to easily direct the pattern the installation is consistent. DualCore signal processing analyzes where needed • Decreased Liability PIR and microwave signals through the – No mounting height adjustments Self-test—alerts end-user and central 5898 microcontroller. DualCore – 7-9 mounting height means fewer station if the motion detector stops processing supports a multitude of restrictions than current offerings functioning advanced functions, including – Easy opening case concurrent diagnostics, digital – Covered circuit board reduces risk • Hot or Cold Temperature Alert fluorescent light interference filter, of installer initiated damage – (< 45° F) warns when temperatures adaptive baselines and bidirectional are approaching the freezing point • Fewer Service Calls temperature compensation. – (> 95° F) warns when temperatures Incorrect installation of equipment or are rising too high• K-Band Microwave Technology changing requirements at the site (e.g., K-Band microwave technology delivers new pets) are no longer a problem with: • Commercial Dealer—Additional sharp detection without holes or weak – Automatic walk test mode turns Benefits spots. The custom-made source offers on the walk test LED for ten – New longer range patterns allow pattern shaping to fill the protected area minutes. Walk test mode can also more wireless options with a broad, balloon-shape that be triggered with a flashlight. – Colder operation down to -4º F (-20º C) matches the PIR pattern. It also offers – Remotely programmable sensitivity for use in unheated areas pattern containment to reduce the – Longer battery life – High or low temperature detection penetration of microwave energy – End-user replaceable batteries – Look down option provides through walls. – Black bug guard means 15% fewer increased security right below false alarms due to bright lights the detector• Faster and Easier to Install directed into the PIR – Back tamper switch—required Specific features that contribute to this – UV protected lenses for commercial certificated installations benefit include: – Automatic walk test • Same Family Look – Flashlight walk test Dealers can install one family look – Remotely programmable sensitivity whether they use hardwired, V-Plex® or – Circuit board does not need to be wireless in order to complete the job. In removed to install on wall addition, if the dealers need to mix and
  2. 2. 5898WIRELESS K-BAND DUAL TEC MOTION SENSORORDERING5898 Wireless K-Band DUAL TEC Motion SensorACCESSORIES0-000-110-01 SMB10 Universal White Swivel Mount Bracket (5 pack)0-000-155-01 SMB10T Tampered Universal White Swivel Mount Bracket (5 pack)0-000-111-01 SMB10C Universal White Ceiling Mount Bracket (5 pack)DT7000-LRLK Long Range Lens Kit 50 x 10 (15 m x 3 m)DT7000-HSLK High Security Lens Kit 35 x 40 (11 m x 12 m)DT7000-PALK Pet Alley Lens Kit 35 x 40 (11 m x 12 m) 0 3m 6m 9m 12 m 15 m 3m 0 3m 6m 9m 12 m 15 m 7.5 2.3 mDT7000-LRLK 5 1.5 m 2 0.6 mLR Curtain Lens 0 0 0 0 10 20 30 40 50Kit Pattern 10 0 10 20 30 40 50DT7000-HSLKHigh Security Lens DT7000-PALK Pet Alley Lens SMB10 SMB10T SMB10CFor more information:www.honeywell.com/security/hscAutomation and Control SolutionsHoneywell Security & Communications2 Corporate Center Dr. Suite 100P.O. Box 9040Melville, NY 11747 L/5898D/D1.800.467.5875 September 2010www.honeywell.com © 2010 Honeywell International Inc.
  3. 3. 5898WIRELESS K-BAND DUAL TEC MOTION SENSORDETECTION PATTERNS50/15m Wide Angle Lens 35/11m Animal Immune Lens5898 DUAL TE C 5898 DUAL TE CTop View Top View50 x 60, (15m x 18m); 90° wide angle 35 x 40, (11m x 12m); 90° wide angleSide View Side View 2X 0.65 2X 0.65 [1.7] [1.7] 4.92 [12.5] 3.63 [9.2] 3.35 0.69 [8.5] [1.8] 1.38 [3.5] 3.63 [9.2] 2.89 [7.3] 3.35 [8.5] 2.95 [7.5] 2.05 [5.2]
  4. 4. 5898WIRELESS K-BAND DUAL TEC MOTION SENSORSPECIFICATIONS• Detection Method • Mounting Height • Fluorescent Light Filter Dual Technology Sensor with – 7 to 9 (2.1m to 2.7m) – 50 Hz or 60 Hz, selectable – Dual Element Passive Infrared • Tamper Switch • Dimensions – K-Band Microwave – Front cover and back tamper – W = 2.95" (7.5cm)• Range • Sensitivity – H = 4.92" (12.5cm) – 50 x 60 (15m x 18m); 90° wide angle – Remotely selectable – D = 2.05" (5.2cm) - 44 zones (22 long range, 12 - Loop 1 = Pulse count 2 [50 lbs or • Weight intermediate, 6 lower, 4 look-down) 100 lbs of pet immunity – 7.55 oz packaged product – 35 x 40 (11m x 12m); 90° wide angle - Loop 2 = Pulse count 1 [0 lbs of (0.21407 kg) - 102 zones (44 long range, 36 pet immunity] • Includes: intermediate, 18 lower, 4 look-down) • Self Test – Mounting hardware• Power – Internally checks the PIR, temperature – Lens masking – Four 1.5V AA, Energizer L91, ® compensation and pyroelectric circuits – Four 1.5V Lithium AA batteries Honeywell 462 disabling the RF supervision signal if – 50 x 60 wide area lens (installed)• RF Frequency six consecutive self tests fail – 35 x 40 animal immune lens (included) – 345 MHz • Temperature Detection (Selectable) • Approvals/Listings• Operating Temperature – Low temperature —FCC part 15, Class B verified – For indoor use environment - Fault = < 45° F (7° C) for > 20 to —IC, RSS-210, Class B verified -4° F to 131° F (-20° C to 55° C) 60 minutes —C-Tick• Relative Humidity, Non-condensing - Restore = > 48° F (9° C) for > 20 —UL Listed to UL639 – 95% max to 60 minutes —cUL Listed to ULC-S306• Detectable Walk Rate – High temperature Battery Life Curve* – 0.7 – 7 ft/Sec. (0.2 – 2.0m/Sec.) - Fault = > 95° F (35° C) for > 20 The 5898 has a battery life of up to• Temperature Compensation to 60 minutes 4.5 years (in a typical installation with an – Advanced Dual Slope - Restore = < 92° F (33° C) for > average of 80 motion events per day).• Pet/Animal Immunity 20 to 60 minutes *Battery life may vary depending on – 0, 50 or 100 lbs (0, 22.6, or 45 Kg) • Microwave Frequencies alarms per day and environmental When used with the animal immune – 24.125 GHz (K-Band) conditions of the installation site. lens (included)

×