Successfully reported this slideshow.

Heating or Chilled Water Energy Measurement From Outside The Pipe – Simple & Low Cost Heat Meters

1

Share

Loading in …3
×
1 of 4
1 of 4

More Related Content

More from Thorne & Derrick UK

Related Books

Free with a 14 day trial from Scribd

See all

Heating or Chilled Water Energy Measurement From Outside The Pipe – Simple & Low Cost Heat Meters

  1. 1. The new heat/energy metering solution from Micronics. Simple, low cost, hot or chilled water energy measurement from outside the pipe. A smarter solution than in-line meters! The U1000 HM is an ultrasonic clamp-on heat/energy meter that uses ultrasound to measure flow rate and PT100 temperature sensors to measure flow and return temperatures. The U1000 HM displays energy rate and totalised energy with pulse output and Modbus communication, so it can be used as a standalone meter or as an integral part of an aM&T or BEM’s system. Simple to install – clamp-on to the pipe, set the pipe diameter and connect the power, no specialist skills or tools required and Modbus compatible. • Rate and totalised heat/energy demand • Easy to install • Clamp-on flow and temperature sensors • Lower installed cost than in-line meters Ultraflo U1000 HM For further information please visit: www.micronicsflowmeters.com or call +44 (0)1628 810456 MADE IN BRITAIN Tel: +44 (0)191 490 1547 Fax: +44 (0)191 477 5371 Email: northernsales@thorneandderrick.co.uk Website: www.heattracing.co.uk www.thorneanderrick.co.uk
  2. 2. U1000 HM Specification Measurement Technique: Transit time and PT100 Class B 4 wire Turn Down Ratio: 200:01 Heat Meter Standard: The Heat/Energy calculation is designed to comply with EN1434 section 6, third party certification pending. Accuracy: +/-1-3% of flow reading for 0.3m/s Flow Velocity Range: 0.1 to 10m/s Pipe Range: 25mm – 115mm OD Water Temp Range: 0°C to 85°C Temperature sensors: Clamp-on PT100 Class B 4 wire, range 0 to 85°C, resolution 0.1 °C Output: Pulse or Frequency, Energy or Volume flow Modbus Communication: Modbus RTU slave, RS485 serial link hardware layer. Energy, power, temperature and flow. External Power Supply: 12V-24V +/- 10% AC/DC at 7 watts Electronics Enclosure: IP54 Input/Output Cable: 5m x 6 core for power in and data out Dimensions: 250mm x 48mm x 90mm (electronics + guide rail) U1000 HM – Fixed Ultrasonic Heat/Energy Meter with Modbus Communication Ultraflo U1000 HM INDUSTRIES: n Energy Management n Building Services RECOMMENDED FOR: n Hot water 85°C n Chilled water APPLICATION/USE: n Heat/energy metering in energy management or building services applications for LTHW or chilled water circuits. PIPE MATERIALS: n Steel n Plastic n Copper Micronics Limited accepts no responsibility or liability if this product has not been installed in accordance with the installation instructions applicable to the product. Micronics reserve the right to alter any specification without notification. Tel: +44 (0)191 490 1547 Fax: +44 (0)191 477 5371 Email: northernsales@thorneandderrick.co.uk Website: www.heattracing.co.uk www.thorneanderrick.co.uk
  3. 3. Clamp-on with Micronics for major installation savings, minimal downtime and dry servicing. The U3000 U1000 latest generation of clamp-on, ultrasonic flow meters from Micronics are a viable alternative to in-line meters for HVAC metering, in both retrofit and new build applications, delivering major installation savings, minimal downtime, maximised availability and significant maintenance benefits. Liquid flow metering including LTHW, Chilled water and DHWS plus flow measurement for Thermal Energy measurement are all areas where clamp- on meters offer a best value solution for Building Services or Energy Management i.e. they will be significantly cheaper to install than traditional in-line meters and as they’re non-invasive they deliver maximum availability through dry servicing and minimal maintenance. The larger the pipe size the greater the installed saving will be but with the elimination of flanges and by-pass valves significant savings are available for a wide range of pipe sizes with major savings for larger applications! The following is a comparison of new build installation costs the comparable savings for retrofit would be higher: Pipe Size mm – Steel Pipe Total cost of installing insertion meters with maintenance bypass Cost of installing clamp on ultrasonic meter, half hour labour up to 50mm, 1 hour labour from 50mm Additional cost of insertion meter installation i.e. potential savings – wiring assumed to be equal: 25 £468 £6.20 £462 40 £601 £6.20 £595 50 £704 £6.20 £697 65 £1,681 £12.40 £1,669 80 £1,992 £12.40 £1,980 125 £3,873 £12.40 £3,860 150 £4,840 £12.40 £4,828 Insulation of clamp on and insertion meters assumed to be similar Costs from Spons ME It’s appreciated that competitive tendering would reduce these cost estimates. MADE IN BRITAIN The above demonstrates the potential installation price savings from using a clamp-on solution, which would deliver an installed clamp-on meter price with savings ranging from significant to major from 50mm upwards. And with the added benefits of being non-invasive, requiring only dry servicing and maximising availability. U3000/U1000
  4. 4. CLAMP-ON WITH MICRONICS FOR MAJOR INSTALLATION SAVINGS, MINIMAL DOWNTIME AND DRY SERVICING. The U3000 U1000 latest generation of clamp-on, ultrasonic flow meters from Micronics are a viable alternative to in-line meters for HVAC metering, in both retrofit and new build applications, delivering major installation savings, minimal downtime, maximised availability and significant maintenance benefits. Liquid flow metering including LTHW, Chilled water and DHWS plus flow measurement for Thermal Energy measurement are all areas where clamp- on meters offer a best value solution for Building Services or Energy Management i.e. they will be significantly cheaper to install than traditional in-line meters and as they’re non-invasive they deliver maximum availability through dry servicing and minimal maintenance. The larger the pipe size the greater the installed saving will be but with the elimination of flanges and by-pass valves significant savings are available for a wide range of pipe sizes with major savings for larger applications! The following is a comparison of new build installation costs the comparable savings for retrofit would be higher: Pipe Size mm Steel Pipe Total cost of installing insertion meters with maintenance bypass Cost of installing clamp on ultrasonic meter, half hour labour up to 50mm, 1 hour labour from 50mm Additional cost of insertion meter installation i.e. potential savings – wiring assumed to be equal: 25 £468 £6.20 £462 40 £601 £6.20 £595 50 £704 £6.20 £697 65 £1,681 £12.40 £1,669 80 £1,992 £12.40 £1,980 125 £3,873 £12.40 £3,860 150 £4,840 £12.40 £4,828 Insulation of clamp on and insertion meters assumed to be similar Costs from Spons ME It’s appreciated that competitive tendering would reduce these cost estimates. MADE IN BRITAIN The above demonstrates the potential installation price savings from using a clamp-on solution, which would deliver an installed clamp-on meter price with savings ranging from significant to major from 50mm upwards. And with the added benefits of being non-invasive, requiring only dry servicing and maximising availability. U3000/U1000

×