Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
Eltherm ELK-MI_CN Heat Trace Cable - Spec Sheet
1. Heating cable
highly robust
Factory terminated heating cable, suitable for assembly on systems, apparatus, vessels, pipes, valves
and similar. The optimum solution for moisture proof applications in a temperature range above 200 °C.
Can be immersed in fluids. The heating cable meets the requirements on resistance to mechanical
stress.
Type ELK-MI/CN up to 400 °C
Advantages:
Factory terminated
Hermetically sealed metal sheath
Highly robust and mechanically stable
Moisture proof
High chemical resistance
High output per meter
High working temperatures
Heating cable und Heizbänder 1.39
Applications:
Moisture proof applications at medium outputs
and temperatures
Can be immersed in fluids
Heat tracing on piping
Tank containers
Heat tracing on vessels
Heat tracing on valves
Chemical industry
heating cables and heating tapes Tel: +44 (0)191 490 1547
Fax: +44 (0)191 477 5371
Email: northernsales@thorneandderrick.co.uk
Website: www.heattracing.co.uk
www.thorneanderrick.co.uk
2. 03/2012 – All rights reserved. Subject to change without notice.
Technical information
Data
Outer jacket CuNi
Working temp., max. 400 °C
Nominal output up to 70 W/m
Nominal voltage up to 600 V AC
Cold lead, length 2 x 0,50 m
Cold lead, cross section 2,50 mm²
Cable gland brass M20 x 1,5
Protective conductor integrated
connection
IP rating IP 65
Protection class I
Bending radius diameter x 5
Moisture proof yes
Type ELK-MI/CN
up to 400 °C
Heating conductor
Insulation
magnesium oxide
Outer jacket
CuNi
A table of chemical resistances is available on our website
www.eltherm.com.
Other cross sections and lengths of cold leads are available upon
request.
Important: Avoid multiple bends with minimum bending radius
(risk of cable damage).
No. Diameter =
mm
Resistance
Ω/km
1 3,00 4.150
2 3,10 2.400
3 3,20 1.600
4 3,40 1.000
5 3,70 630
6 4,00 400
7 4,20 312
8 4,40 250
9 4,90 160
10 5,20 122
*Note: The output per meter of heating cable and the maximum possible working tempe-ratures
depend on the respective application. For individual cases, we recommend that you
contact our engineers – we will be pleased to advise you.
This is just a summary of all available resistances. For further resistances, please contact us.
For suitable connection and termination kits please note our considerable accessories catalogue unit.
1.40 heating Heating cables cable und and Heizbänder heating tapes Telefon: Phone: +49 (0) 27 36 / 44 13-0 www.eltherm.com
Tel: +44 (0)191 490 1547
Fax: +44 (0)191 477 5371
Email: northernsales@thorneandderrick.co.uk
Website: www.heattracing.co.uk
www.thorneanderrick.co.uk