MemoryPAT
Battery Powered Portable Appliance Tester
with Display & Memory
Overview of the MemoryPAT
Power on test –
checks that
appliance is
switched on
Easy to use –
Just work out Class I,
Class ...
What comes in the box?
 MemoryPAT unit
 USB lead and mains
charger
 Test lead
 Short IEC lead
 User manual
 Equipmen...
Layout of user controls
Layout of LCD Display
Large 6 line backlit LCD display, with clear layout of test results.
Power on test
This test is done automatically when the Class I or Class II buttons are
pressed to make sure that the power...
Class 1 test
When the Class 1 button is pressed this test will be
carried out and the display will show the test results
f...
Class II test
When the Class II button is pressed this test is
carried out and the display will show the test
results for ...
Testing IEC leads
When the Power Cord button is pressed this
test will be carried out and the display will show
the test r...
Testing long mains extension leads
The Power Cord button is used for this test. The
display will show the test results for...
Adjusting for different lead lengths
Use the long lead button to adjust the
lead length to 15 meters.
After 1 press of the...
Testing surge protected appliances
The default test voltage for Insulation Resistance
is 500V and this works well with the...
Recalling results from Memory
The MemoryPAT saves the last 2000 test
results in internal memory. The user can
review these...
Downloading results to PC
All the test results in memory can be downloaded to a PC using a
FREE MemoryPAT Download Utility...
Excel spread sheet of test results
Test & Overall Outcome Power ON Test Earth Continuity Test Insulation Resistance Test P...
Useful Links
MemoryPAT user manual
MemoryPAT data sheet
Download utility
Video of Download installation
Test adaptors for ...
Upcoming SlideShare
Loading in …5
×

MemoryPAT

2,610 views

Published on

Picture of MemoryPAT - PAT Tester with Display and Memory

The MemoryPAT Portable Appliance tester is a very easy to use battery powered PAT tester with display and memory to hold 2000 test results. It comes with Lifetime Warranty and is designed and manufactured by First Stop Safety.

As well as showing PASS or FAIL when a test is done the results of the test are shown and saved to memory. This tester uses built-in rechargeable batteries and is supplied with a charger. The MemoryPAT is safe for testing IT equipment and comes with short IEC lead and a selection of labels.

Published in: Technology, Business
  • Be the first to comment

MemoryPAT

  1. 1. MemoryPAT Battery Powered Portable Appliance Tester with Display & Memory
  2. 2. Overview of the MemoryPAT Power on test – checks that appliance is switched on Easy to use – Just work out Class I, Class II or Power cord & press button Insulation test at 500V or 250V - Can be adjusted for surge protected appliances Battery powered – Can do more than 500 tests between charges 6 line back LCD display with back-lighting– All the information on one screen which can be read even under a desk Results of 2000 tests saved in memory – can be downloaded to PC Long lead button- Going up in 5 metre steps up-to 50 metres
  3. 3. What comes in the box?  MemoryPAT unit  USB lead and mains charger  Test lead  Short IEC lead  User manual  Equipment Register form  Test Record form  100 Tested, 5 Failed labels  50 Fuse labels
  4. 4. Layout of user controls
  5. 5. Layout of LCD Display Large 6 line backlit LCD display, with clear layout of test results.
  6. 6. Power on test This test is done automatically when the Class I or Class II buttons are pressed to make sure that the power switch on the appliance is in the ON position. This is handy if you have forgotten to switch this ON. The following message is displayed to remind you. If the power switch is in the ON position then the following message is displayed and the tester proceeds to carry out the test.
  7. 7. Class 1 test When the Class 1 button is pressed this test will be carried out and the display will show the test results for the Insulation Resistance and Earth Continuity tests as well as an overall Pass or Fail. The image below shows the result of a test that shows a pass. The results show that the Earth Continuity was 80 milli-ohms using the default 1 metre lead length. The Insulation Resistance was very high at > 20 M ohms when tested using a voltage of 500V. The test number on the last line (188 in this example) increments automatically for each test.
  8. 8. Class II test When the Class II button is pressed this test is carried out and the display will show the test results for the Insulation Resistance test as well as an overall Pass or Fail. The image below shows the result of a test that shows a pass. The results show that the Insulation Resistance was very high at > 20 M ohms when tested using a voltage of 500V. The test number on the last line (1288 in this example) increments automatically for each test.
  9. 9. Testing IEC leads When the Power Cord button is pressed this test will be carried out and the display will show the test results for the Earth Continuity, Insulation Resistance and Wiring tests as well as an overall Pass or Fail. The image below shows the result of a test that shows a pass. The results show that the Earth Continuity was 80 milli-ohms using the default 1 metre lead length. The Insulation Resistance was very high at > 20 M ohms when tested using a voltage of 500V. The wiring test shows that the IEC lead is wired correctly.
  10. 10. Testing long mains extension leads The Power Cord button is used for this test. The display will show the test results for the Earth Continuity, Insulation Resistance and Wiring tests as well as an overall Pass or Fail. The default pass limit is set for a 1 metre long cable. The image below shows the result of a test on a 15 metre long mains extension lead that shows a fail. The results show that the Earth Continuity was 250 milli-ohms using the default 1 metre lead length. This is a fail. The Insulation Resistance was very high at > 20 M ohms when tested using a voltage of 500V. The wiring test shows that the IEC lead is wired correctly.
  11. 11. Adjusting for different lead lengths Use the long lead button to adjust the lead length to 15 meters. After 1 press of the long lead button the display will be as shown here. After 2 more presses the cursor will move to the 15 metre setting with a pass limit of 0.4 ohms. This is the same as 400 milli ohms. Now when the test is redone, the 15 metre long extension lead will pass, because we have adjusted the limit appropriately.
  12. 12. Testing surge protected appliances The default test voltage for Insulation Resistance is 500V and this works well with the majority of appliances. However ones fitted with surge protection can fail when tested at this voltage. This is due to the 500V test voltage being seen as a potential surge by the protection devices which start to limit at this level. If this is the case, then use the 500V/250V button to set the 250V option. Now when the test is done, the Insulation Resistance is tested at 250V.
  13. 13. Recalling results from Memory The MemoryPAT saves the last 2000 test results in internal memory. The user can review these at any time by pressing the Memory ◄ button found on the right of the Display. Pressing the Memory ◄ button again will show older results while pressing the Memory ►button will show more recent test results. If the Memory ◄ or the ► buttons are kept pressed for more than 5 seconds, the unit will step through the memory faster in steps of 10.
  14. 14. Downloading results to PC All the test results in memory can be downloaded to a PC using a FREE MemoryPAT Download Utility. There is information here on how to download and install the software. Here is a video of the software installation. Once the software is installed, connect the MemoryPAT to the PC using the USB cable that is supplied. When you launch the software the screen below is displayed.
  15. 15. Excel spread sheet of test results Test & Overall Outcome Power ON Test Earth Continuity Test Insulation Resistance Test Polarity Test ID Test type Pass / Fail On / Off Length (Mtrs) Milliohms Pass / Fail Voltage Megaohms Pass / Fail Pass / Fail 1 Class 2 Pass Off 250 >20.0 Pass 2 Class 2 Pass Off 250 >20.0 Pass 3 Class 2 Pass Off 250 >20.0 Pass 4 Class 2 Pass Off 250 >20.0 Pass 5 Class 2 Pass Off 250 >20.0 Pass 6 Class 2 Pass Off 250 >20.0 Pass 7 Class 2 Pass Off 250 >20.0 Pass 8 Class 2 Pass Off 250 >20.0 Pass 9 Class 2 Pass Off 250 >20.0 Pass 10 Class 2 Pass Off 250 >20.0 Pass 11 Class 2 Pass Off 250 >20.0 Pass 12 Class 2 Pass Off 500 >20.0 Pass 13 Power Cord Fail 1 >2000 Fail 500 >20.0 Pass Fail 14 Power Cord Fail 1 >2000 Fail 500 >20.0 Pass Fail 15 Power Cord Fail 1 >2000 Fail 250 >20.0 Pass Fail 16 Power Cord Fail 1 >2000 Fail 500 >20.0 Pass Fail 17 Class 2 Pass Off 500 >20.0 Pass 18 Power Cord Fail 1 >2000 Fail 500 >20.0 Pass Fail 19 Power Cord Fail 1 >2000 Fail 500 >20.0 Pass Fail 20 Power Cord Fail 1 >2000 Fail 500 >20.0 Pass Fail 21 Power Cord Fail 1 >2000 Fail 500 >20.0 Pass Fail 22 Power Cord Fail 1 >2000 Fail 500 >20.0 Pass Fail 23 Power Cord Fail 1 >2000 Fail 500 >20.0 Pass Fail Below is a sample of downloaded data
  16. 16. Useful Links MemoryPAT user manual MemoryPAT data sheet Download utility Video of Download installation Test adaptors for 110V, 3-phase and other types of appliances Accessories for your MemoryPAT

×