  1. 1. Harmony XPE and 9002AW foot switches briefing Property of Schneider Electric Simply reliable. Simply available. December 2017
  2. 2. • Introduction to the Harmony offer • Introduction to foot switches • Offer presentation  XPE and 9002AW foot switches  Features  Panorama • UVPs • Targeted applications • Where to find further details • Quiz Table of content Page 2Property of Schneider Electric |
  3. 3. General purpose control Control offers overview – Harmony Page 3Property of Schneider Electric | Hoisting Safety Pushbuttons, switches, and pilot lights Wireless remote control Foot switches and two-hand control Control stations XALD/K XALGXALE XAPXALF XB5R/XB4R XB5S/Ø 22 9001K/SK/Ø 30 XVL/Ø 8-12XB6/Ø 16 K Cam XB4/Ø 22 XB5/Ø 22 XB7/Ø 22 XKB XKMXKD Seat and joysticks eXLhoist Pendant station XPE Y/B/G XPE M/R Preventa XY2 SB XB4 ATEX D Explosive atmosphere
  4. 4. • A foot switch is a control unit which is operated on machines or systems where tasks using the hands are not possible for ergonomic or safety reasons ‒ For example, the machine operator may need to hold a tool, a piece of metal, another actuator, or any necessary device ‒ In some applications, such as power presses, additional operator protection such as point-of-operation guarding must be provided when a foot switch is used as an actuator • Foot switches are particularly suited for start and stop operations as well as adjustment tasks • The control of 2-speed machines as well as “hold to run” machine cycles are also possible What is a foot switch used for? Page 4Property of Schneider Electric | Foot operation for safety reason (operation is controlled with a safety light curtain) Foot operation for ergonomic reason
  5. 5. XPE and 9002AW Foot Switch ranges Page 5Property of Schneider Electric | XPEA XPEY XPEB/G XPEB/R 9002AW Material Pedal and housing made of plastic Pedal, housing and cover made of fire-retardant and shock-proof plastic Pedal, housing and cover made of fire-retardant and shock-proof plastic Pedal and housing made of die-casted metal, and cast aluminum cover Pedal, housing and cover made of die-casted metal Resistance to oil, water, dust IP43 IP55 IP66 IP66 Nema 4 and 13, IP69 Mechanical life 2 million operating cycles > 2 million operating cycles > 5 million operating cycles > 5 million operating cycles > 7 million operating cycles Certifications CE, CCC, EAC CE, CCC, EAC CE, UL, CSA, CCC, EAC CE certified ; CSA for XPEM (blue version) CE, UL, CSA
  6. 6. A comprehensive offer for any requirements Page 6Property of Schneider Electric | *Never use a protective cover, a trigger mechanism nor a safety door for issuing a normal stop instruction to a machine. Access to the stop control must be as unrestricted as possible and without any constraints. Protective cover* Avoids the risk of accidental operation by falling objects, which could result in unintentional starting of the machine Extended comfort Heel rest avoids discomfort in the base of the backbone due to unbalanced positioning of the body. Hand grip enables to easily carry the foot switch at different places. Trigger mechanism* Enables locking of the pedal in the released position. It prevents the lowering of the pedal in case the foot is not fully inserted into the pedal. This prevents from involuntary actuation of the foot switch. Pedal latching Foot switches with pedal latching device are particularly suited for the control of “hold to run” machines, and also, for adjustments. Atex D (protection against dust) available Single or double pedal Pressing the pedal gives the machine start instruction and, when the pedal reaches its limit, it latches in the operated position. Removing the foot from the pedal will not stop the machine cycle, the pedal remains latched. For issuing a normal stop, the foot is replaced on the pedal and the toe plate is operated: this returns the pedal to the rest position. toe plate Start Run Stop heel rest hand grip Safety door* Requires the intentional motion to lift the door before inserting the foot, to prevent accidental operation. Contact Blocks The foot switch can incorporate 1 or 2 ‘N/C+N/O’ contact blocks with snap action and positive opening , an analog output, with 1 or 2 steps.
  7. 7. Offer panorama Page 7Property of Schneider Electric | XPEA XPEY XPEG XPEB XPEM XPER 9002AW Material and resistance Pedal and housing made of plastic  Pedal, housing and cover made of fire-retardant and shock-proof plastic    Pedal and housing made of die-casted metal, and cast aluminum cover   Pedal, housing and cover made of die-casted metal  Resistance to oil, water and dust IP43 IP55 IP66 IP66 IP66 IP66 Nema4, 13; IP69 Mechanical life (in million of operating cycles) 2 > 2 > 5 > 5 > 5 > 5 > 7 Output 1 contact block 'N/C+N/O', snap action, positive opening        2 contact blocks 'N/C+N/O', snap action, positive opening        Analog output   Action 1 step        2 steps       Pedal latching    Double pedal   Protection Protective cover       Trigger mechanism      Safety door  Environment Atex D   Comfort Hand grip   Heel rest   Color Black  Yellow   Grey  Blue   Orange  Certification CE        UL    CSA     EAC       CCC      
  8. 8. • Robustness in harsh environments ‒ Resistance to shocks ‒ Resistance to oil, water, dust ‒ Very long mechanical life: up to 7 million operating cycles • Protection by design: positive opening operations o XPE foot switches: ‒ The pedal hold down and the pedal release actions have a positive actuation fully compliant with IEC 60947-5-1 standard (Electromechanical control circuit devices) ‒ It means that the electro-mechanical design of the XPE foot switch is such that the release of the pedal, to stop the machine for example, directly triggers the opening of the normally closed contacts • Compactness and comfort ‒ The foot switch is designed such that the largeness of the operating pedal is maximized to accommodate all types of footwear (large size, safety boots, …) while restraining the depth of the foot switch Range values Page 8Property of Schneider Electric | Resistance
  9. 9. • The range of foot switches is used in all environments from light duty to heavy duty ones • They are installed on very different types of machine, among which Foot switches for diverse applications Page 9Property of Schneider Electric | Boom lifts Advanced machine tools: CN lathes, shears, presses,… Manual assembly station Packaging Pharmaceutics Wood workingStandard machine tools: shears, presses,… Harsh environment XPEA XPEY XPEB/G XPEM/R 9002AW
  10. 10. • Click here to find info on SE.com • Click here to find XPE on SE.com • Click here to access our Digicat • Click here to access to CAD files • Click on the link below for FAQs (frequently asked question) Where to find details Page 10Property of Schneider Electric |
  11. 11. Property of Schneider Electric | Quiz Based on what you’ve learned so far, try to answer to this quiz ? Page 11 What is a foot switch used for? Q1 Is the foot switch range convenient for 2-speed machines? Q2 What is the minimum mechanical life of the foot switch offer? Q3 Has the XPE’s pedal release a positive actuation, according to IEC 60947-5-1? Q4 Which foot switch to choose for an advanced machine tool? Q5
  12. 12. Property of Schneider Electric | Quiz answers What is a foot switch used for? Q1 A foot switch is operated on machines or systems where tasks using the hands are not possible for ergonomic or safety reasons. Page 12 Answers Is the foot switch range convenient for 2-speed machines? Q2 Yes, The control of 2-speed machines is possible using 2-step foot switches. What is the minimum mechanical life of the foot switch offer? Q3 The minimum mechanical life of XPE offer is 2 million operating cycles. 9002AW offer can reach more than 7 million operating cycles. Has the XPE’s pedal release a positive actuation, according to IEC 60947-5-1? Q4 Yes, the design of the XPE foot switch is such that the release of the pedal directly triggers the opening of the normally closed contacts Which foot switch to choose for an advanced machine tool? Q5 XPEM (blue) or XPER (orange) offers are particularly suited for demanding environment and protection against heavy falling object.
  13. 13. Page 13Property of Schneider Electric | Thank you

×