Successfully reported this slideshow.
We use your LinkedIn profile and activity data to personalize ads and to show you more relevant ads. You can change your ad preferences anytime.
www.sunshineproject.eu
SUNSHINE - Smart UrbaN ServIces for Higher eNergy Efficiency (GA no: 325161)
D6.4 S1.1
Introduction...
SUNSHINE Training Module S1
• Presentation of SCENARIO 1
• Heating energy needs estimation
• The Map4Data App
• Building a...
Smart UrbaN ServIces for Higher eNergy Efficiency
Scenario 1
Wide-scale assessment of heating energy needs
for residential...
Scenario 1
Wide-scale assessment of heating energy needs
for residential buildings
The idea …
• The idea is to estimate the energy performance of
residential buildings at large scale (city-wide), using
ava...
Energy label (the Netherlands) …
http://energielabelatlas.nl/#zuid-holland/delft/17/52.0122/4.3612
https://www.youtube.com/watch?v=6kslOHSRY8U
https://www.youtube.com/user/SunshineProjectEu/videos
http://sunshine.graphite...
Heating energy need estimation
Set of software modules for:
1. Model/import open geodata on spatial db
– GeoUML Catalogue,...
Footprint from cadastre
or high quality topo db
Energy consumption
from SIATEL
3D from high res. LidarUValues and other pr...
Regional Topographic database
Municipal Buildings Register
(Anagrafe Comunale degli Immobili)
www.sunshineproject.eu
SUNSHINE - Smart UrbaN ServIces for Higher eNergy Efficiency (GA no: 325161)
Databases and desk res...
Missing mandatory
data; not verified.
Alcuni
Missing mandatory
data; verified.
All mandatory data
present; not verified.
A...
Building properties
(on 2nd click)
Editing of multi-value
attribute
www.sunshineproject.eu
SUNSHINE - Smart UrbaN ServIces for Higher eNergy Efficiency (GA no: 325161)
On-field data verifica...
www.sunshineproject.eu
SUNSHINE - Smart UrbaN ServIces for Higher eNergy Efficiency (GA no: 325161)
Qt = 10-3  HT  24  ...
https://www.youtube.com/watch?v=6kslOHSRY8U
https://www.youtube.com/user/SunshineProjectEu/videos
http://sunshine.graphite...
www.sunshineproject.eu
SUNSHINE - Smart UrbaN ServIces for Higher eNergy Efficiency (GA no: 325161)
Credits
For more train...
S.1.1 Introduction to Scenario 1
S.1.1 Introduction to Scenario 1
S.1.1 Introduction to Scenario 1
Upcoming SlideShare
Loading in …5
×

S.1.1 Introduction to Scenario 1

628 views

Published on

SUNSHINE Project: introduction to Scenario 1

Published in: Technology
  • Be the first to comment

  • Be the first to like this

S.1.1 Introduction to Scenario 1

  1. 1. www.sunshineproject.eu SUNSHINE - Smart UrbaN ServIces for Higher eNergy Efficiency (GA no: 325161) D6.4 S1.1 Introduction to SUNSHINE Scenario 1 „Building Energy Awareness”
  2. 2. SUNSHINE Training Module S1 • Presentation of SCENARIO 1 • Heating energy needs estimation • The Map4Data App • Building analysis and simulation tool • Validation ConsortiumSUNSHINEProject | GAno.325161 | CIPFPproject,ICTPSPPilotTypeB | Feb2013–Jan2016
  3. 3. Smart UrbaN ServIces for Higher eNergy Efficiency Scenario 1 Wide-scale assessment of heating energy needs for residential buildings Scenario 2 Building energy awareness tools to support efficient management of heating/cooling systems Scenario 3 Remote monitoring and control of public lighting systems to support a more energy efficient management
  4. 4. Scenario 1 Wide-scale assessment of heating energy needs for residential buildings
  5. 5. The idea … • The idea is to estimate the energy performance of residential buildings at large scale (city-wide), using available spatial data (geodata) from authoritative sources: – Footprints, heights, construction periods… – Building construction typologies… The goal … • To provide an approach and tools to facilitate the planning and the monitoring of energy plans.
  6. 6. Energy label (the Netherlands) … http://energielabelatlas.nl/#zuid-holland/delft/17/52.0122/4.3612
  7. 7. https://www.youtube.com/watch?v=6kslOHSRY8U https://www.youtube.com/user/SunshineProjectEu/videos http://sunshine.graphitech-projects.com
  8. 8. Heating energy need estimation Set of software modules for: 1. Model/import open geodata on spatial db – GeoUML Catalogue, PostGIS, QGIS 2. Verify completeness/correctness (app) – PhoneGap 3. Compute energy needs – WPS 4. Visualize / simulate / validate – Cesium
  9. 9. Footprint from cadastre or high quality topo db Energy consumption from SIATEL 3D from high res. LidarUValues and other properties (e.g. age of construction) from Energy Certificates registers
  10. 10. Regional Topographic database
  11. 11. Municipal Buildings Register (Anagrafe Comunale degli Immobili)
  12. 12. www.sunshineproject.eu SUNSHINE - Smart UrbaN ServIces for Higher eNergy Efficiency (GA no: 325161) Databases and desk research Age of construction of buildings (source: Cervellati L. (editor), 1976, Il centro storico di Ferrara, Franco Angeli) Buildings destroyed during II world war (source: University of Ferrara)
  13. 13. Missing mandatory data; not verified. Alcuni Missing mandatory data; verified. All mandatory data present; not verified. All mandatory data present; verified.
  14. 14. Building properties (on 2nd click) Editing of multi-value attribute
  15. 15. www.sunshineproject.eu SUNSHINE - Smart UrbaN ServIces for Higher eNergy Efficiency (GA no: 325161) On-field data verification Click to open YouTube video
  16. 16. www.sunshineproject.eu SUNSHINE - Smart UrbaN ServIces for Higher eNergy Efficiency (GA no: 325161) Qt = 10-3  HT  24  DD  V  S/V  A [kWh/mA 2year] = [kW/mS 2K]  [h/Kyear]  [mS 2/mA 2] Building Type Construction Year Facade element Typical U-value [W/m2K] Typical % of facade Walls full/semi-full bricks 1,08 60% Roof bricks and concrete 0,95 10% Floor bricks and concrete 0,92 10% Windows thermal break frames + low-emission glass 2,63 20% Typical heath transmission coefficient for building envelope HT [W/mS 2K] Country Climatic Zone Typical climatic parameters Heating season lenght 183 days Average outdoor temperature during the heating season 12° C Indoor design temperature 20° C Typical Degree Days DDt [days/Kyear] Typical building shape parameters Heated volume (V) 1234 mS 3 Shape factor (S/V) 0.66 mS -1 Useful floor area (A) 353 mS 2 Typical Consumption Qt [kWh/mA 2year]
  17. 17. https://www.youtube.com/watch?v=6kslOHSRY8U https://www.youtube.com/user/SunshineProjectEu/videos http://sunshine.graphitech-projects.com
  18. 18. www.sunshineproject.eu SUNSHINE - Smart UrbaN ServIces for Higher eNergy Efficiency (GA no: 325161) Credits For more training material and courses visit http://www.sunshineproject.eu/solutions/training or contact us directly at training@sunshineproject.eu Source:www.unionegeometri.com Thank you! Luca Giovannini Sinergis Srl luca.giovannini@sinergis.it

×