Vascular InterventionsVascular Interventions
Ergin Atalar, Ph.D.Ergin Atalar, Ph.D.
Johns Hopkins UniversityJohns Hopkins ...
Johns Hopkins University
OverviewOverview
– Intravascular MRI (first human experiments)Intravascular MRI (first human expe...
Johns Hopkins University
Intravascular MRIIntravascular MRI
MR Imaging Guidewire
Surgi-Vision, Inc.
Johns Hopkins University
mm
B
FSE, 1200/13-msec TR/TE, Double IR blood suppression, 16 ETL, 4-cm FOV, 32 NEX,
256x256 matr...
Johns Hopkins University
Post stent: human iliac IVMRIPost stent: human iliac IVMRI
L. Hofmann, D. Bluemke
Rt common iliac...
Johns Hopkins University
L. Hofmann, D. Bluemke
Fibrous cap
Lipid
core
Plaque CharacterizationPlaque Characterization
Johns Hopkins University
Restenosis - s/p renal stentRestenosis - s/p renal stent
5 mm
L. Hofmann, D. Bluemke
Rt renal art...
In-Vivo Human Iliac Artery:In-Vivo Human Iliac Artery:
Concentric AtherosclerosisConcentric Atherosclerosis
Angiography 20...
Johns Hopkins University
MR-guided Balloon AngioplastyMR-guided Balloon Angioplasty
 Technical Challenges:Technical Chall...
Johns Hopkins University
Johns Hopkins University
Johns Hopkins University
Scan RoomScan Room
J. Serfaty et. al.
Johns Hopkins University
MRI-guided PTCAMRI-guided PTCA
90° 10° 90°10°
slice selection projection
J. Serfaty et. al.
Johns Hopkins University
DilatationDilatation of the Pulmonary Arteryof the Pulmonary Artery
C. Rickers, 2001
Dilatation with Gd filled balloonDilatation with Gd filled balloon
C. Rickers, 2001
Dilatation with air filled balloonDilatation with air filled balloon
C. Rickers, 2001
Johns Hopkins University
MR-guided Stent PlacementMR-guided Stent Placement
 Technical ChallengesTechnical Challenges
– M...
Johns Hopkins University
MR Guidewire Tracking/PlacementMR Guidewire Tracking/Placement
sheath
 FGREFGRE
 256x162256x162...
Johns Hopkins University
MRI Guided Stent Positioning and DeploymentMRI Guided Stent Positioning and Deployment
stent
live...
Johns Hopkins University
Intravascular Wire StentIntravascular Wire Stent
CrossingCrossing
 SPGRSPGR
 256x162256x162
 T...
Johns Hopkins University
High Resolution Aortic ImagingHigh Resolution Aortic Imaging
stent
MRIG
(Imaging
Guidewire)
SPGR,...
Johns Hopkins University
MR-guided Gene Therapy
A Remedy gene delivery balloon catheter
Gene delivery channel
Angioplasty
balloon
channel
Guidewire channel
0.014” MRIG
Tu...
Johns Hopkins University
Design
Plaque
Plaque
Vessel
0.014” MRIG
Balloon
inflation
with 3% Gd
Gd/blue-dye medium or
Gd/GFP...
Johns Hopkins University
BA
X
Clinical significance?
X. Yang, et al. Circulation 2001
Johns Hopkins University
ConclusionConclusion
 MRI has potential to guide new and
conventional vascular interventions
Upcoming SlideShare
Loading in …5
×

Intravascular mri diagnostic and therapeutic potentials

106 views

Published on

SHAPE Society

Published in: Health & Medicine
  • Be the first to comment

  • Be the first to like this

Intravascular mri diagnostic and therapeutic potentials

  1. 1. Vascular InterventionsVascular Interventions Ergin Atalar, Ph.D.Ergin Atalar, Ph.D. Johns Hopkins UniversityJohns Hopkins University Departments of Radiology and Biomedical EngineeringDepartments of Radiology and Biomedical Engineering DISCLOSURE:DISCLOSURE: E. Atalar is a founder and stock holder of Surgi-Vision, Inc.E. Atalar is a founder and stock holder of Surgi-Vision, Inc.
  2. 2. Johns Hopkins University OverviewOverview – Intravascular MRI (first human experiments)Intravascular MRI (first human experiments) – Balloon AngioplastyBalloon Angioplasty – Stent PlacementStent Placement – MR-guided Gene TherapyMR-guided Gene Therapy
  3. 3. Johns Hopkins University Intravascular MRIIntravascular MRI
  4. 4. MR Imaging Guidewire Surgi-Vision, Inc.
  5. 5. Johns Hopkins University mm B FSE, 1200/13-msec TR/TE, Double IR blood suppression, 16 ETL, 4-cm FOV, 32 NEX, 256x256 matrix, 10 min 14 sec acquisition time ACM • Resolution: 150 µm J. M. Serfaty et al. Watanabe rabbit with a 0.032” MRI-Guidewire Aortic wall imaging
  6. 6. Johns Hopkins University Post stent: human iliac IVMRIPost stent: human iliac IVMRI L. Hofmann, D. Bluemke Rt common iliac art. Guidewire (venous) Fibrous cap Lipid core T1 - pre gad T1 - post gad
  7. 7. Johns Hopkins University L. Hofmann, D. Bluemke Fibrous cap Lipid core Plaque CharacterizationPlaque Characterization
  8. 8. Johns Hopkins University Restenosis - s/p renal stentRestenosis - s/p renal stent 5 mm L. Hofmann, D. Bluemke Rt renal artery Guidewire in IVC restenosis
  9. 9. In-Vivo Human Iliac Artery:In-Vivo Human Iliac Artery: Concentric AtherosclerosisConcentric Atherosclerosis Angiography 20 MHz IVUS IVMRI No Abnormality Concentric Atherosclerosis 5 mm 5 mm Vein K. Yucel, et. al. Brigham and Women’s Hospital
  10. 10. Johns Hopkins University MR-guided Balloon AngioplastyMR-guided Balloon Angioplasty  Technical Challenges:Technical Challenges: – MR compatible/visible Balloon AngioplastyMR compatible/visible Balloon Angioplasty CatheterCatheter – Methods for Monitoring Balloon AngioplastyMethods for Monitoring Balloon Angioplasty ProcedureProcedure
  11. 11. Johns Hopkins University
  12. 12. Johns Hopkins University
  13. 13. Johns Hopkins University Scan RoomScan Room J. Serfaty et. al.
  14. 14. Johns Hopkins University MRI-guided PTCAMRI-guided PTCA 90° 10° 90°10° slice selection projection J. Serfaty et. al.
  15. 15. Johns Hopkins University
  16. 16. DilatationDilatation of the Pulmonary Arteryof the Pulmonary Artery C. Rickers, 2001
  17. 17. Dilatation with Gd filled balloonDilatation with Gd filled balloon C. Rickers, 2001
  18. 18. Dilatation with air filled balloonDilatation with air filled balloon C. Rickers, 2001
  19. 19. Johns Hopkins University MR-guided Stent PlacementMR-guided Stent Placement  Technical ChallengesTechnical Challenges – MR compatible and visible stent deploymentMR compatible and visible stent deployment devicedevice – MR compatible stentMR compatible stent – Methods of monitoring stent placementMethods of monitoring stent placement procedureprocedure
  20. 20. Johns Hopkins University MR Guidewire Tracking/PlacementMR Guidewire Tracking/Placement sheath  FGREFGRE  256x162256x162  20 mm slice20 mm slice  4 element4 element cardiac coilcardiac coil A. Lardo et. al.
  21. 21. Johns Hopkins University MRI Guided Stent Positioning and DeploymentMRI Guided Stent Positioning and Deployment stent liver stomach Ao  SPGRSPGR  256x162256x162  TR/TE=4.4/1.2TR/TE=4.4/1.2  20 mm slice20 mm slice  4 element cardiac4 element cardiac coilcoil A. Lardo et. al.
  22. 22. Johns Hopkins University Intravascular Wire StentIntravascular Wire Stent CrossingCrossing  SPGRSPGR  256x162256x162  TR/TETR/TE  20 mm slice20 mm slice  3 element3 element cardiac coilcardiac coil + 1 element+ 1 element internal coilinternal coil stent 1 stent 2 MRI guidewire A. Lardo et. al.
  23. 23. Johns Hopkins University High Resolution Aortic ImagingHigh Resolution Aortic Imaging stent MRIG (Imaging Guidewire) SPGR, 256x256, FOV=4 cm Guidewire element only stented wall 156µm A. Lardo et. al.
  24. 24. Johns Hopkins University MR-guided Gene Therapy
  25. 25. A Remedy gene delivery balloon catheter Gene delivery channel Angioplasty balloon channel Guidewire channel 0.014” MRIG Tuning box X. Yang, et al. Circulation 2001
  26. 26. Johns Hopkins University Design Plaque Plaque Vessel 0.014” MRIG Balloon inflation with 3% Gd Gd/blue-dye medium or Gd/GFP-lentivirus medium X. Yang, et al. Circulation 2001
  27. 27. Johns Hopkins University BA X Clinical significance? X. Yang, et al. Circulation 2001
  28. 28. Johns Hopkins University ConclusionConclusion  MRI has potential to guide new and conventional vascular interventions

×