Anhydrous Ammonia Measurement for oil and water

Roland Sirois
Roland SiroisCEO at Orono Spectral Solutions, Inc.
1
Anhydrous Ammonia
Measurements
Roland Sirois
CONFIDENTIAL
2
Measurement Options
• Anhydrous Ammonia – oil & std water level
• Urea – oil
• DEF – oil
• UAN – oil
• Water – oil
• Air - oil
Technology applications in a wide range of products
3
Orono Spectral Solutions
• Spinoff of University of Maine (US) Laboratory
for Surface Science and Technology
• Awarded 14 government projects ($8.6 M)
• 2013 Tibbets Award & 2016 CF Safety Award
Leading edge solid state surface technology driven organization
4
Measuring oil in Ammonia
• CF Industries looking for solutions to
– Safely test oil contamination in ammonia
– Quickly identify process control issues
– Reduce corporate risk
Request from a leading ammonia manufacturer led to application
5
Materials Required to Measure
Glass ware, hot plate and dangerous chemicals
6
Oil Determination – Process
Evaporate Hexane
Mass corresponds to
concentration of
extractable material
Collect Large
Sample
Evaporate
Ammonia
Add
Hexane
Test Time: 8+ hours Tech Time: 3+ hours
Current method is long, complex, dangerous and costly
7
• Large sample size
• Safety risk: carrying sample through the plant
• Solvent (n-Hexane) & acid use
• Complex process
• Time consuming
• One “shot”
• Costly
Issues with the Current Process
Several factors with current method are driving development
8
New Process Equipment
No glassware, no chemicals, simple process
9
New Process Summary
Collect Small
Sample
Extract Sample Place in FTIR
Time: < 20 minutes
0
.1
.2
.3
.4
.5
.6
.7
3050 3000 2950 2900 2850 2800 2750
Absorbance / Wavenumber (cm-1) Paged X-Zoom CURSOR
File # 1 : BASELINE 11/5/2007 6:47 PM Res=8
disk 1 background after 10 ml ~30ppm oil in water
Absorbance(a.u.)
Wavenumber (cm-1)
Simple, quick, accurate and less costly process addesses SHE
10
FTIR Measurement
A =- log10 = e l c
l
C, e
Io I
I
Io
Where:
A = absorbance
e = absorptivity
l= pathlength
c = concentration
Infrared technology enables precise quantitative measurement
Membrane
11
Oil in Ammonia Output
Oil absorbance at 2920 and height relates to concentration
0
.1
.2
.3
.4
.5
.6
.7
3050 3000 2950 2900 2850 2800 2750
Absorbance(a.u.)
Wavenumber (cm-1)
12
• Sample 10 mls for each test - triplicate
• Place the extractor into the FTIR beam
• Program provides operator with a ppm oil level
• Permanent record of the results
Summary of New Process
Simple, accurate, safe and creates a permanent record
20 Min
13
Measurement of Known Amount
Spiking amount of mineral oil and measuring using technology
Method Performance Summary Data
Method Detection Limit 0.2 mg/L (ppm)
Detection Range 0.2 – 20 mg/L (ppm)
Precision at 3.5 mg/L 12%
14
Benefits of the New Process
Proven overwhelming advantages of new technology
• Complicated
• Fragile Glassware
• 500+ mL Ammonia (1 sample)
• Boiling Water, Hot Plate
• Hexane, Hydrochloric Acid
• 1-Day Turnaround Time
• 3 Hours for Lab Technician
• Hazardous Waste
• Chemistry
• Operating Cost
• Simple
• No Glassware
• 30 mL Ammonia (3 samples)
• No Heat Source Required
• No Additional Chemicals
• 20-Minute Turnaround Time
• 20 Minutes for Lab Technician
• Recyclable, Reusable Filters
• EPA Green Chemistry
• Operating Cost 25 – 30% less
Old Method New Method
15
• Reduce risk – safety, environmental
• Lower material on hold and rework potential
• Ability to ”dial in” water content
• Proven quality data and sample retention
Site Advantages
Financial impact of new technology is significant
16
• Use similar syringe and same sample size
• 10 mls of sample into extractor (10 sec)
• 10 mls of deionized water into extractor (20 sec)
• Drying of extractor
– Oven drying
– Air drying (dry air)
Oil in DEF and Urea
Process is similar to oil in ammonia but with drying required
17
• For transportation by truck, rail or pipe
– Minimum 0.2% water content (US Gov. requirement)
• Current process
– Time consuming
– Inaccurate
• Alternative process submitted to US DOT
– Once approval granted, companies can follow
process
• Commercial requirement 0.5% maximum
Water in Ammonia
In US process is regulated by US Department of Transportation (DOT)
18
• Small sample from manufacturing site
– Representative sample
– Protect sample from moisture
• Transfer to sampling container
– Protect sample from moisture
• Present the sample to the FTIR unit
– Protect sample from moisture
Water in Ammonia - Challenge
Protect sample from moisture in the air
19
Sampling for water in Ammonia
In process sample bottle to protect ammonia from moisture
• Pristine sample
• Protect technician
• Protect sample
20
Sample Carrier and Stand
Sample bottle stand and holder inside air hood
21
View of Sample Prep System
Maximize operator safety and sample integrity
• In lab system
• Ensures safety
• Uniform sample
22
Dry Air System
Portable air curtain supply kit to ensure sample integrity
23
Sample container for extraction
Transfer jar under dry air curtain
24
Details of Dry Air System
Positive dry air flow maintains curtain around sample
• Ammonia container
• Dry Air Container
• Dry Air Delivery
25
Water in Ammonia extractor
Extractor, FTIR Card and Hoses to provide dry air
• Extractor
• FTIR Card
• Dry air lines
26
Water in Ammonia extractor
Extractor, FTIR Card and Hoses to provide dry air
27
Accurate delivery of Ammonia
Small amount of sample required for test method
• Pipette
• Disposable tips
28
Sampling Ammonia
Using Pipette to sample exact amount for test
29
Ammonia sample on Extractor
Small sample will evaporate until extractor is dry
30
Inserting FTIR card into Unit
Place card into unit and run software
31
Test Method Detection Range
Measurement range is well within system capabilities
Method Data Summary
METHOD DETECTION LIMIT
(98% Confidence) MDL Detection Range
0.09% 0.2% - 0.5%
32
Customer Site Measurement
Accuracy of system demonstrated in test results
Method: Water in Anhydrous Ammonia
Fortification Level of CGA G-2.2 Verified Dry Anhydrous Ammonia: 0.3% Water
Measured Result: % Water
REP 1 REP 2 REP 3 REP 4 REP 5 REP 6 REP 7 REP 8 REP 9 REP 10
0.32 0.27 0.28 0.34 0.36 0.30 0.31 0.33 0.28 0.35
Average of 10 Replicates: 0.3154 % Water
Standard Deviation of 10 Replicates: 0.032 % Water
MDL (Student’s t 2.821 x Standard Deviation) (98%Confidence): 0.09 % water
33
Accuracy of Method
Measurements at the low end of the test requirements
Method: Water in Anhydrous Ammonia
Fortification Level of CGA G-2.2 Verified Dry Anhydrous Ammonia: 0.2% Water
Rep. Recovery (% water in AA)
Recovery as a % of known fortification amount
(0.2%)
1 0.2084 104.2%
2 0.1753 87.6%
3 0.2324 116.2%
4 0.2125 106.2%
5 0.2697 134.8%
6 0.2365 118.2%
7 0.2464 123.2%
Average 0.2259 112.9%
St. Dev. 0.0304
34
Accuracy of Method
Measurements at the high end of the test requirements
Method: Water in Anhydrous Ammonia
Fortification Level of CGA G-2.2 Verified Dry Anhydrous Ammonia: 0.5% Water
Rep. Recovery (% water in AA)
Recovery as a % of known fortification amount
(0.5%)
1 0.4574 91.5%
2 0.4923 98.4%
3 0.4475 89.5%
4 0.4843 96.8%
5 0.5191 103.8%
6 0.4744 94.9%
7 0.5401 108.0%
Average 0.4879 97.6%
St. Dev. 0.0329
35
Accuracy of Method
Water content of spiked samples over range 0 to 0.6%
36
1 of 36

Recommended

Dds 50 temas by
Dds 50 temasDds 50 temas
Dds 50 temasJailson1212
6.7K views47 slides
Ch10 semenanalysis by
Ch10 semenanalysisCh10 semenanalysis
Ch10 semenanalysisShabab Ali
5.2K views41 slides
CSF EXAMINATION.pptx by
CSF EXAMINATION.pptxCSF EXAMINATION.pptx
CSF EXAMINATION.pptxChakmaManson
208 views78 slides
PARASITOLOGI DIAGNOSIS MAKMAL JANGKITAN MALARIA by
PARASITOLOGI DIAGNOSIS MAKMAL JANGKITAN MALARIAPARASITOLOGI DIAGNOSIS MAKMAL JANGKITAN MALARIA
PARASITOLOGI DIAGNOSIS MAKMAL JANGKITAN MALARIAIeyza Ieyriza II
5.4K views14 slides
Qc failure lecture - Dr tamer soliman by
Qc failure lecture - Dr tamer solimanQc failure lecture - Dr tamer soliman
Qc failure lecture - Dr tamer solimanTamer Soliman
348 views61 slides
Semen analysis WHO 2010 BY DR ANAMIKA DEV by
Semen analysis WHO 2010 BY DR ANAMIKA DEVSemen analysis WHO 2010 BY DR ANAMIKA DEV
Semen analysis WHO 2010 BY DR ANAMIKA DEVAnamika Dev
12.5K views134 slides

More Related Content

What's hot

Treinamento da CIPA - Blog Segurança do Trabalho.ppt by
Treinamento da CIPA - Blog Segurança do Trabalho.pptTreinamento da CIPA - Blog Segurança do Trabalho.ppt
Treinamento da CIPA - Blog Segurança do Trabalho.pptCIPAcipa2
170 views99 slides
Aulão sst by
Aulão sstAulão sst
Aulão sstthiago_design
21.6K views73 slides
Microbiological aspects in sepsis by
Microbiological aspects in sepsisMicrobiological aspects in sepsis
Microbiological aspects in sepsisDr. Md Ashraf Ali Namaji
974 views18 slides
semen analysis by
semen analysissemen analysis
semen analysisRavi Jain
67.7K views75 slides
Extraction of Nucleic Acid From FFPE Tissue Samples by
Extraction of Nucleic Acid From FFPE Tissue SamplesExtraction of Nucleic Acid From FFPE Tissue Samples
Extraction of Nucleic Acid From FFPE Tissue SamplesThermo Fisher Scientific
3.6K views41 slides
SMS apresentação 2011 by
SMS apresentação 2011SMS apresentação 2011
SMS apresentação 2011gendesigns
6.6K views35 slides

What's hot(20)

Treinamento da CIPA - Blog Segurança do Trabalho.ppt by CIPAcipa2
Treinamento da CIPA - Blog Segurança do Trabalho.pptTreinamento da CIPA - Blog Segurança do Trabalho.ppt
Treinamento da CIPA - Blog Segurança do Trabalho.ppt
CIPAcipa2170 views
semen analysis by Ravi Jain
semen analysissemen analysis
semen analysis
Ravi Jain67.7K views
SMS apresentação 2011 by gendesigns
SMS apresentação 2011SMS apresentação 2011
SMS apresentação 2011
gendesigns6.6K views
Semen analysis Latest WHO (2010) by MohdAkhtar6
Semen analysis Latest WHO (2010)Semen analysis Latest WHO (2010)
Semen analysis Latest WHO (2010)
MohdAkhtar61.2K views
Apresentação investigação e análise de acidentes by wagnernpinto
Apresentação investigação e análise de acidentesApresentação investigação e análise de acidentes
Apresentação investigação e análise de acidentes
wagnernpinto4.4K views
Semen analysis by Sizan Thapa
Semen analysisSemen analysis
Semen analysis
Sizan Thapa4.5K views
How to write Standard Operating Procedures (SOPs) for clinical laboratories -... by Tamer Soliman
How to write Standard Operating Procedures (SOPs) for clinical laboratories -...How to write Standard Operating Procedures (SOPs) for clinical laboratories -...
How to write Standard Operating Procedures (SOPs) for clinical laboratories -...
Tamer Soliman5.2K views
Propostas para DDS by carlos ars
Propostas para DDSPropostas para DDS
Propostas para DDS
carlos ars69K views
Quality Control In Histopathology Dr.Rami amawi.pptx by Rami Al Amawi
Quality Control In Histopathology Dr.Rami amawi.pptxQuality Control In Histopathology Dr.Rami amawi.pptx
Quality Control In Histopathology Dr.Rami amawi.pptx
Rami Al Amawi 892 views
1 general-approach-in-investigation-of-hemostasis1 by DuyenNguyen307
1 general-approach-in-investigation-of-hemostasis11 general-approach-in-investigation-of-hemostasis1
1 general-approach-in-investigation-of-hemostasis1
DuyenNguyen307136 views
01 mob-produtos-perigosos-cbmgo-2017-corrigido by AILTON RUIZ
01 mob-produtos-perigosos-cbmgo-2017-corrigido01 mob-produtos-perigosos-cbmgo-2017-corrigido
01 mob-produtos-perigosos-cbmgo-2017-corrigido
AILTON RUIZ456 views
Donor Screening Criteria by EBAI
Donor Screening CriteriaDonor Screening Criteria
Donor Screening Criteria
EBAI5.6K views
Processos Gâlvanicos by xandaobyte
Processos GâlvanicosProcessos Gâlvanicos
Processos Gâlvanicos
xandaobyte12.6K views
8 apresentação - acidentes de trabalho by Nilton Goulart
8   apresentação - acidentes de trabalho8   apresentação - acidentes de trabalho
8 apresentação - acidentes de trabalho
Nilton Goulart11.9K views

Similar to Anhydrous Ammonia Measurement for oil and water

Measuring Oil in Ammonia - OSS ClearShot Technology by
Measuring Oil in Ammonia - OSS ClearShot TechnologyMeasuring Oil in Ammonia - OSS ClearShot Technology
Measuring Oil in Ammonia - OSS ClearShot TechnologyRoland Sirois
2.8K views18 slides
Process Solutions from Wet Chemistry to Near-Infrared Spectroscopy by
Process Solutions from Wet Chemistry to Near-Infrared SpectroscopyProcess Solutions from Wet Chemistry to Near-Infrared Spectroscopy
Process Solutions from Wet Chemistry to Near-Infrared SpectroscopyMetrohm USA
1.8K views66 slides
GPO Application Dataset by
GPO Application DatasetGPO Application Dataset
GPO Application Datasetjnic
339 views67 slides
validation HPLC and HPTLC D-A star.pptx by
validation HPLC and HPTLC D-A star.pptxvalidation HPLC and HPTLC D-A star.pptx
validation HPLC and HPTLC D-A star.pptxDevaPundkar
7 views35 slides
Utilizing Online TOC Monitoring to Control Industrial Water Quality by
Utilizing Online TOC Monitoring to Control Industrial Water QualityUtilizing Online TOC Monitoring to Control Industrial Water Quality
Utilizing Online TOC Monitoring to Control Industrial Water QualityMuhammad Naeem Ashraf
406 views31 slides
Sterile process validation by
Sterile process validationSterile process validation
Sterile process validationSagar Savale
27.8K views43 slides

Similar to Anhydrous Ammonia Measurement for oil and water(20)

Measuring Oil in Ammonia - OSS ClearShot Technology by Roland Sirois
Measuring Oil in Ammonia - OSS ClearShot TechnologyMeasuring Oil in Ammonia - OSS ClearShot Technology
Measuring Oil in Ammonia - OSS ClearShot Technology
Roland Sirois2.8K views
Process Solutions from Wet Chemistry to Near-Infrared Spectroscopy by Metrohm USA
Process Solutions from Wet Chemistry to Near-Infrared SpectroscopyProcess Solutions from Wet Chemistry to Near-Infrared Spectroscopy
Process Solutions from Wet Chemistry to Near-Infrared Spectroscopy
Metrohm USA1.8K views
GPO Application Dataset by jnic
GPO Application DatasetGPO Application Dataset
GPO Application Dataset
jnic339 views
validation HPLC and HPTLC D-A star.pptx by DevaPundkar
validation HPLC and HPTLC D-A star.pptxvalidation HPLC and HPTLC D-A star.pptx
validation HPLC and HPTLC D-A star.pptx
DevaPundkar7 views
Utilizing Online TOC Monitoring to Control Industrial Water Quality by Muhammad Naeem Ashraf
Utilizing Online TOC Monitoring to Control Industrial Water QualityUtilizing Online TOC Monitoring to Control Industrial Water Quality
Utilizing Online TOC Monitoring to Control Industrial Water Quality
Sterile process validation by Sagar Savale
Sterile process validationSterile process validation
Sterile process validation
Sagar Savale27.8K views
GPO Customer Presentation by jnic
GPO Customer PresentationGPO Customer Presentation
GPO Customer Presentation
jnic932 views
PDA Poster Presentation - Particle Reduction_R01 by Aaron Mertens
PDA Poster Presentation - Particle Reduction_R01PDA Poster Presentation - Particle Reduction_R01
PDA Poster Presentation - Particle Reduction_R01
Aaron Mertens998 views
Oms by manjeet6
OmsOms
Oms
manjeet61.8K views
5 Steps to Achieve More CostEffective Aminebased Carbon Capture Processes at ... by NazrulIslam657555
5 Steps to Achieve More CostEffective Aminebased Carbon Capture Processes at ...5 Steps to Achieve More CostEffective Aminebased Carbon Capture Processes at ...
5 Steps to Achieve More CostEffective Aminebased Carbon Capture Processes at ...
Validation of compressed air and nitrogen by ManiKandan1405
Validation of compressed air and nitrogenValidation of compressed air and nitrogen
Validation of compressed air and nitrogen
ManiKandan14054.6K views
Clean In Place Technlogies BioPharma Facilities by Ranjeet Kumar
Clean In Place Technlogies BioPharma FacilitiesClean In Place Technlogies BioPharma Facilities
Clean In Place Technlogies BioPharma Facilities
Ranjeet Kumar4.4K views
Sterile Facilities by Eric Sipe
Sterile FacilitiesSterile Facilities
Sterile Facilities
Eric Sipe997 views
Le price training presentation by zainudinyahya
Le price training presentationLe price training presentation
Le price training presentation
zainudinyahya1.7K views
Leak Detection And Repair by Ashutosh Soni
Leak Detection And RepairLeak Detection And Repair
Leak Detection And Repair
Ashutosh Soni2.7K views
Support utilities validation.pptx (asmita magare) by magareasmi
Support utilities validation.pptx (asmita magare)Support utilities validation.pptx (asmita magare)
Support utilities validation.pptx (asmita magare)
magareasmi3.8K views

Recently uploaded

overview of the causes and effects of drinking water scarcity in the uae.pdf by
overview of the causes and effects of drinking water scarcity in the uae.pdfoverview of the causes and effects of drinking water scarcity in the uae.pdf
overview of the causes and effects of drinking water scarcity in the uae.pdfajaalfalasi
8 views7 slides
Challenges for WG1 by
Challenges for WG1Challenges for WG1
Challenges for WG1ipcc-media
41 views12 slides
Healthcare Waste Management by
Healthcare Waste ManagementHealthcare Waste Management
Healthcare Waste ManagementDr. Salem Baidas
21 views25 slides
Where is global warming in relation to the long-term temperature goal? by
Where is global warming in relation to the long-term temperature goal?Where is global warming in relation to the long-term temperature goal?
Where is global warming in relation to the long-term temperature goal?ipcc-media
28 views30 slides
Transformational Mitigation For Industry Sectors Exposed To International Com... by
Transformational Mitigation For Industry Sectors Exposed To International Com...Transformational Mitigation For Industry Sectors Exposed To International Com...
Transformational Mitigation For Industry Sectors Exposed To International Com...ipcc-media
54 views11 slides
Carbon Dioxide Removal to reach net-zero and return from overshoot by
Carbon Dioxide Removal to reach net-zero and return from overshootCarbon Dioxide Removal to reach net-zero and return from overshoot
Carbon Dioxide Removal to reach net-zero and return from overshootipcc-media
182 views12 slides

Recently uploaded(20)

overview of the causes and effects of drinking water scarcity in the uae.pdf by ajaalfalasi
overview of the causes and effects of drinking water scarcity in the uae.pdfoverview of the causes and effects of drinking water scarcity in the uae.pdf
overview of the causes and effects of drinking water scarcity in the uae.pdf
ajaalfalasi8 views
Challenges for WG1 by ipcc-media
Challenges for WG1Challenges for WG1
Challenges for WG1
ipcc-media41 views
Where is global warming in relation to the long-term temperature goal? by ipcc-media
Where is global warming in relation to the long-term temperature goal?Where is global warming in relation to the long-term temperature goal?
Where is global warming in relation to the long-term temperature goal?
ipcc-media28 views
Transformational Mitigation For Industry Sectors Exposed To International Com... by ipcc-media
Transformational Mitigation For Industry Sectors Exposed To International Com...Transformational Mitigation For Industry Sectors Exposed To International Com...
Transformational Mitigation For Industry Sectors Exposed To International Com...
ipcc-media54 views
Carbon Dioxide Removal to reach net-zero and return from overshoot by ipcc-media
Carbon Dioxide Removal to reach net-zero and return from overshootCarbon Dioxide Removal to reach net-zero and return from overshoot
Carbon Dioxide Removal to reach net-zero and return from overshoot
ipcc-media182 views
The road ahead for the IPCC Special Report on Climate Change and Cities in AR7 by ipcc-media
The road ahead for the IPCC Special Report on Climate Change and Cities in AR7The road ahead for the IPCC Special Report on Climate Change and Cities in AR7
The road ahead for the IPCC Special Report on Climate Change and Cities in AR7
ipcc-media70 views
Exceeding-returning-Intro-v1Dec-final.pptx by ipcc-media
Exceeding-returning-Intro-v1Dec-final.pptxExceeding-returning-Intro-v1Dec-final.pptx
Exceeding-returning-Intro-v1Dec-final.pptx
ipcc-media76 views
oral presentation mansoor#1.pptx by mk79psx
oral presentation mansoor#1.pptxoral presentation mansoor#1.pptx
oral presentation mansoor#1.pptx
mk79psx8 views
Opportunities for scaling up climate action by ipcc-media
Opportunities for scaling up  climate actionOpportunities for scaling up  climate action
Opportunities for scaling up climate action
ipcc-media52 views
Low-emission food system perspectives in Viet Nam by CIFOR-ICRAF
Low-emission food system perspectives in Viet NamLow-emission food system perspectives in Viet Nam
Low-emission food system perspectives in Viet Nam
CIFOR-ICRAF8 views
Interoperability between the IPCC Inventory Software and IPCC Inventory Softw... by ipcc-media
Interoperability between the IPCC Inventory Software and IPCC Inventory Softw...Interoperability between the IPCC Inventory Software and IPCC Inventory Softw...
Interoperability between the IPCC Inventory Software and IPCC Inventory Softw...
ipcc-media99 views
Reverse The Great Disconnect - Strategies for business disruption beyond unli... by Christoph Tänzer
Reverse The Great Disconnect - Strategies for business disruption beyond unli...Reverse The Great Disconnect - Strategies for business disruption beyond unli...
Reverse The Great Disconnect - Strategies for business disruption beyond unli...
Energy System Transitions in the context of sustainable development: Findings... by ipcc-media
Energy System Transitions in the context of sustainable development: Findings...Energy System Transitions in the context of sustainable development: Findings...
Energy System Transitions in the context of sustainable development: Findings...
ipcc-media55 views
Panoramica sulle certificazioni di sostenibilità - Mazzaglia, Vireo by Etifor srl
Panoramica sulle certificazioni di sostenibilità - Mazzaglia, VireoPanoramica sulle certificazioni di sostenibilità - Mazzaglia, Vireo
Panoramica sulle certificazioni di sostenibilità - Mazzaglia, Vireo
Etifor srl14 views
Physical Science Challenges for AR7 by ipcc-media
Physical Science Challenges for AR7Physical Science Challenges for AR7
Physical Science Challenges for AR7
ipcc-media267 views

Anhydrous Ammonia Measurement for oil and water

  • 2. 2 Measurement Options • Anhydrous Ammonia – oil & std water level • Urea – oil • DEF – oil • UAN – oil • Water – oil • Air - oil Technology applications in a wide range of products
  • 3. 3 Orono Spectral Solutions • Spinoff of University of Maine (US) Laboratory for Surface Science and Technology • Awarded 14 government projects ($8.6 M) • 2013 Tibbets Award & 2016 CF Safety Award Leading edge solid state surface technology driven organization
  • 4. 4 Measuring oil in Ammonia • CF Industries looking for solutions to – Safely test oil contamination in ammonia – Quickly identify process control issues – Reduce corporate risk Request from a leading ammonia manufacturer led to application
  • 5. 5 Materials Required to Measure Glass ware, hot plate and dangerous chemicals
  • 6. 6 Oil Determination – Process Evaporate Hexane Mass corresponds to concentration of extractable material Collect Large Sample Evaporate Ammonia Add Hexane Test Time: 8+ hours Tech Time: 3+ hours Current method is long, complex, dangerous and costly
  • 7. 7 • Large sample size • Safety risk: carrying sample through the plant • Solvent (n-Hexane) & acid use • Complex process • Time consuming • One “shot” • Costly Issues with the Current Process Several factors with current method are driving development
  • 8. 8 New Process Equipment No glassware, no chemicals, simple process
  • 9. 9 New Process Summary Collect Small Sample Extract Sample Place in FTIR Time: < 20 minutes 0 .1 .2 .3 .4 .5 .6 .7 3050 3000 2950 2900 2850 2800 2750 Absorbance / Wavenumber (cm-1) Paged X-Zoom CURSOR File # 1 : BASELINE 11/5/2007 6:47 PM Res=8 disk 1 background after 10 ml ~30ppm oil in water Absorbance(a.u.) Wavenumber (cm-1) Simple, quick, accurate and less costly process addesses SHE
  • 10. 10 FTIR Measurement A =- log10 = e l c l C, e Io I I Io Where: A = absorbance e = absorptivity l= pathlength c = concentration Infrared technology enables precise quantitative measurement Membrane
  • 11. 11 Oil in Ammonia Output Oil absorbance at 2920 and height relates to concentration 0 .1 .2 .3 .4 .5 .6 .7 3050 3000 2950 2900 2850 2800 2750 Absorbance(a.u.) Wavenumber (cm-1)
  • 12. 12 • Sample 10 mls for each test - triplicate • Place the extractor into the FTIR beam • Program provides operator with a ppm oil level • Permanent record of the results Summary of New Process Simple, accurate, safe and creates a permanent record 20 Min
  • 13. 13 Measurement of Known Amount Spiking amount of mineral oil and measuring using technology Method Performance Summary Data Method Detection Limit 0.2 mg/L (ppm) Detection Range 0.2 – 20 mg/L (ppm) Precision at 3.5 mg/L 12%
  • 14. 14 Benefits of the New Process Proven overwhelming advantages of new technology • Complicated • Fragile Glassware • 500+ mL Ammonia (1 sample) • Boiling Water, Hot Plate • Hexane, Hydrochloric Acid • 1-Day Turnaround Time • 3 Hours for Lab Technician • Hazardous Waste • Chemistry • Operating Cost • Simple • No Glassware • 30 mL Ammonia (3 samples) • No Heat Source Required • No Additional Chemicals • 20-Minute Turnaround Time • 20 Minutes for Lab Technician • Recyclable, Reusable Filters • EPA Green Chemistry • Operating Cost 25 – 30% less Old Method New Method
  • 15. 15 • Reduce risk – safety, environmental • Lower material on hold and rework potential • Ability to ”dial in” water content • Proven quality data and sample retention Site Advantages Financial impact of new technology is significant
  • 16. 16 • Use similar syringe and same sample size • 10 mls of sample into extractor (10 sec) • 10 mls of deionized water into extractor (20 sec) • Drying of extractor – Oven drying – Air drying (dry air) Oil in DEF and Urea Process is similar to oil in ammonia but with drying required
  • 17. 17 • For transportation by truck, rail or pipe – Minimum 0.2% water content (US Gov. requirement) • Current process – Time consuming – Inaccurate • Alternative process submitted to US DOT – Once approval granted, companies can follow process • Commercial requirement 0.5% maximum Water in Ammonia In US process is regulated by US Department of Transportation (DOT)
  • 18. 18 • Small sample from manufacturing site – Representative sample – Protect sample from moisture • Transfer to sampling container – Protect sample from moisture • Present the sample to the FTIR unit – Protect sample from moisture Water in Ammonia - Challenge Protect sample from moisture in the air
  • 19. 19 Sampling for water in Ammonia In process sample bottle to protect ammonia from moisture • Pristine sample • Protect technician • Protect sample
  • 20. 20 Sample Carrier and Stand Sample bottle stand and holder inside air hood
  • 21. 21 View of Sample Prep System Maximize operator safety and sample integrity • In lab system • Ensures safety • Uniform sample
  • 22. 22 Dry Air System Portable air curtain supply kit to ensure sample integrity
  • 23. 23 Sample container for extraction Transfer jar under dry air curtain
  • 24. 24 Details of Dry Air System Positive dry air flow maintains curtain around sample • Ammonia container • Dry Air Container • Dry Air Delivery
  • 25. 25 Water in Ammonia extractor Extractor, FTIR Card and Hoses to provide dry air • Extractor • FTIR Card • Dry air lines
  • 26. 26 Water in Ammonia extractor Extractor, FTIR Card and Hoses to provide dry air
  • 27. 27 Accurate delivery of Ammonia Small amount of sample required for test method • Pipette • Disposable tips
  • 28. 28 Sampling Ammonia Using Pipette to sample exact amount for test
  • 29. 29 Ammonia sample on Extractor Small sample will evaporate until extractor is dry
  • 30. 30 Inserting FTIR card into Unit Place card into unit and run software
  • 31. 31 Test Method Detection Range Measurement range is well within system capabilities Method Data Summary METHOD DETECTION LIMIT (98% Confidence) MDL Detection Range 0.09% 0.2% - 0.5%
  • 32. 32 Customer Site Measurement Accuracy of system demonstrated in test results Method: Water in Anhydrous Ammonia Fortification Level of CGA G-2.2 Verified Dry Anhydrous Ammonia: 0.3% Water Measured Result: % Water REP 1 REP 2 REP 3 REP 4 REP 5 REP 6 REP 7 REP 8 REP 9 REP 10 0.32 0.27 0.28 0.34 0.36 0.30 0.31 0.33 0.28 0.35 Average of 10 Replicates: 0.3154 % Water Standard Deviation of 10 Replicates: 0.032 % Water MDL (Student’s t 2.821 x Standard Deviation) (98%Confidence): 0.09 % water
  • 33. 33 Accuracy of Method Measurements at the low end of the test requirements Method: Water in Anhydrous Ammonia Fortification Level of CGA G-2.2 Verified Dry Anhydrous Ammonia: 0.2% Water Rep. Recovery (% water in AA) Recovery as a % of known fortification amount (0.2%) 1 0.2084 104.2% 2 0.1753 87.6% 3 0.2324 116.2% 4 0.2125 106.2% 5 0.2697 134.8% 6 0.2365 118.2% 7 0.2464 123.2% Average 0.2259 112.9% St. Dev. 0.0304
  • 34. 34 Accuracy of Method Measurements at the high end of the test requirements Method: Water in Anhydrous Ammonia Fortification Level of CGA G-2.2 Verified Dry Anhydrous Ammonia: 0.5% Water Rep. Recovery (% water in AA) Recovery as a % of known fortification amount (0.5%) 1 0.4574 91.5% 2 0.4923 98.4% 3 0.4475 89.5% 4 0.4843 96.8% 5 0.5191 103.8% 6 0.4744 94.9% 7 0.5401 108.0% Average 0.4879 97.6% St. Dev. 0.0329
  • 35. 35 Accuracy of Method Water content of spiked samples over range 0 to 0.6%
  • 36. 36