Are you Ready?
Who’s Upgrading?
2
InputAccel
6.5 SP2
InputAccel
6.5 SP1
InputAccel
6.5
InputAccel
5.3 SP4
Captiva
Capture
7.0
InputAccel
...
First thing first,
Get Prepared
Clean Up Existing Captiva System
• Check for old batches, which can cause problems when updating
• Zero priority batches
•...
New Hardware/Operating Systems
• Take advantage of 64 bit OS for memory
• Update IA server to 64 Bit Windows
• Strongly re...
Establish Performance Baseline
• Captiva Server Metrics for existing system
• DAL average execution time
• DAL average num...
Test/ Prepare for Update
• Captiva Database Updates
• Create backup copy of current Captiva Database
• Run 7.1 database up...
Next step,
Successfully QA
Your Upgrade
Check update process
• Check update logs
• Database update logs
• Windows Event Logs on Captiva Module
servers
• Start of ...
Last, find out how
Reveille Can Help
Captiva metrics
At-a-glance
trending
Pre- / Post-
upgrade values
Thresholds
Take a Product Tour:
http://reveillesoftware.com/product-tour/
user/ReveilleSoftware@ReveilleSoftwre
company/Reveille-Soft...
Upcoming SlideShare
Loading in …5
×

Manage Your EMC Captiva 7.1 Upgrade with Application Performance Management

3,313 views

Published on

Learn tips and best practices about how application performance management can help you successfully complete your migration. See how performance benchmarks and key performance indicators pre- and post-upgrade can help set expectations and measure results - streamlining the upgrade process.

Presentation includes:
- Who needs to upgrade to EMC Captiva 7.1
- 4 steps to getting prepared and details: 1) clean up existing Captiva system, 2) recommended new hardware/operating systems, 3) establish performance baselines, 4) test/prepare for update
- How you successfully QA your upgrade process

See how Reveille can help with pre-configured Captiva metrics, pre- and post-upgrade values, at-a-glance trending and more. Take a product tour: reveillesoftware.com/product-tour

Published in: Technology
  • Be the first to comment

Manage Your EMC Captiva 7.1 Upgrade with Application Performance Management

  1. 1. Manage Your EMC® Captiva® 7.1 Upgrade Are you Ready?
  2. 2. Who’s Upgrading? 2 InputAccel 6.5 SP2 InputAccel 6.5 SP1 InputAccel 6.5 InputAccel 5.3 SP4 Captiva Capture 7.0 InputAccel 6.0 SP3
  3. 3. First thing first, Get Prepared
  4. 4. Clean Up Existing Captiva System • Check for old batches, which can cause problems when updating • Zero priority batches • Task with error status • Locked batches • Old incomplete batches • 7.1 Update process will update the Captiva Database 4 1Reminder: Reveille’s out- of-box tests identify old batches
  5. 5. New Hardware/Operating Systems • Take advantage of 64 bit OS for memory • Update IA server to 64 Bit Windows • Strongly recommended to enhance performance • Enables access to full 32-bit memory space (4 GB) • Update at least some of your module servers to 64 bit Windows OS • Some new IA modules will be strongly recommended to run on 64 bit Windows 5 DO! DO! 2 Remember: 64-bit Windows offers increased performance and security
  6. 6. Establish Performance Baseline • Captiva Server Metrics for existing system • DAL average execution time • DAL average number of data requests • DAL error count • Processing message count • VBA message thread queue length • Database event queue length • WMI Classes for this data • Win32_PerfFormattedData_IA6Dal_IA6Dal • Win32_PerfFormattedData_InputAccel_IA6Server_InputAccel 6 3Did you know? Reveille’s built- in KPIs provide these Captiva Server Metrics
  7. 7. Test/ Prepare for Update • Captiva Database Updates • Create backup copy of current Captiva Database • Run 7.1 database update program against this back up copy and check for any errors • Scripts or Batch files to cleanly shutdown and restart on Captiva modules on all servers • Shutdown Module services first • Shutdown Captiva Server • Apply updates • Start Captiva Servers • Start all module services • Check all modules are connected 7 4 Don’t forget! Reveille tests can be used to verify all modules are connected
  8. 8. Next step, Successfully QA Your Upgrade
  9. 9. Check update process • Check update logs • Database update logs • Windows Event Logs on Captiva Module servers • Start of Captiva Module servers • Confirm all modules are connected to new Captiva IA servers • Compare batch numbers in converted system to those prior to conversion of database • Check Server Side performance against baseline data • Process known set of batches and check for expected results. • Check documents were created as expected 9 Note: Use Reveille to verify pre- and post- upgrade performance statistics & Reveille’s out-of-box tests can verify a test batch runs successfully 5
  10. 10. Last, find out how Reveille Can Help Captiva metrics At-a-glance trending Pre- / Post- upgrade values Thresholds
  11. 11. Take a Product Tour: http://reveillesoftware.com/product-tour/ user/ReveilleSoftware@ReveilleSoftwre company/Reveille-Software

×