Successfully reported this slideshow.
We use your LinkedIn profile and activity data to personalize ads and to show you more relevant ads. You can change your ad preferences anytime.

RCC K&L / KNVvK themadag Slim hergebruik van restwarmte 22 okt. 2015 - Case DK Kälteanlagen GmbH

401 views

Published on

Make heat from cold! – Pay once for energy, but use it twice!

DK will present how to save energy costs by using with the DK-Heat Recovery the waste heat generated during cooling to heat drinking or central heating water.

Let us show you our 37 years’ experience and solutions:

for small and big installations (café with THR of 8 kW or a slaughter house with THR of 250 kW)
for natural coolants (Over 270 installations for transcritical CO2-cooling Systems are running successfully)
for applications with heating of drinking and/or heating water in one tank.

Published in: Engineering
  • Be the first to comment

  • Be the first to like this

RCC K&L / KNVvK themadag Slim hergebruik van restwarmte 22 okt. 2015 - Case DK Kälteanlagen GmbH

  1. 1. DK-Kälteanlagen
  2. 2. DK-Kälteanlagen 2
  3. 3. DK Warmteterugwinning 3
  4. 4. Verminder de energiekost Bescherming van het milieu DK Warmteterugwinning 4
  5. 5. DK Warmteterugwinning 5
  6. 6. In 1979 werd warmte-recuperatie enkel toegepast bij melkkoeling. Dit waren steeds 1 op 1 installaties. DK Warmteterugwinning 6
  7. 7. Verdere ontwikkelingen bij DK DK Warmteterugwinning 7
  8. 8. Melkkoeling Hotel/Catering Industrie Voedingsindustrie Supermarkt ketens DK Warmteterugwinning 8
  9. 9. DK Warmteterugwinning 9
  10. 10. DK Warmteterugwinning mit interne warmtewisselaar 10
  11. 11. Warmteterugwinning ZONDER watercirculatie in de tank Warmteterugwinning MET watercirculatie in de tank 100% 0% 40 K 5 K Gebruik Gemiddeld temperatuurverschil Δ tm DK Warmteterugwinning mit interne warmtewisselaar 11
  12. 12. DK Warmteterugwinning mit interne warmtewisselaar 12
  13. 13. DK Warmteterugwinning mit interne warmtewisselaar 13
  14. 14. DK Warmteterugwinning mit interne warmtewisselaar 14
  15. 15. DK Warmteterugwinning 15
  16. 16. Slagerij Link uit Buchen Geïnstalleerd koelvermogen en type DK warmtewisselaars Type 16/10 (0,8m²) Qo = 1,7 kW Qc = 2,35 kW Type 22/16 (2,0m²) Qo = 4,2 kW Qc = 5,8 kW Totale condensorcapaciteit: Qc = 8,15 kW Geïnstalleerd DK warmterecuperatie systeem: Opslagtank type 500/4 voorzien van 2 interne warmtewisselaars Maximale warmwaterproductie 8,15 kW x 3.600 s/h x 0,85 (η efficiency) = 170,1 l/h4,19 kJ/kgK x 35 K (opwarming van 10°C tot 45°C) x 1.000 kg/m³ Gemiddeld aantal draaiuren: 12 h / dag Maximale dagelijkse warmwaterproductie: 170,1 l/h x 12h/dag = 2.041 l / dag Dagelijks warmwaterverbruik: = 2.000 l / dag Jaarlijks warmwaterverbruik : 365 dagen/jaar x 2.000 l/dag = 730 m³ / jaar Enkele gerealiseerde installaties 16
  17. 17. Enkele gerealiseerde installaties 17 Benodigde energie per jaar voor de productie van warm water: Om water op te warmen van 10 °C naar 45°C (35K) hebben we volgende hoeveelheid energie nodig per jaar: 730 m³/jaar x 4,19 kJ/kgK x 35 K x 1.000 kg/m³ = 29.737 kWh/jaar 3.600 Als de gemiddelde stookolieprijs 0.75 €/l bedraagt dan bekomen we een jaarlijkse besparing van: 3.966 m³/ jaar x 0.75 €/l = 2.974,66,- € per jaar Besparing: Door de toepassing van een DK Warmteterugwinning besparen we volgende hoeveelheid stookolie: 29.737 kWh / jaar = 3.966 l / jaar11,9 kWh / m³ x 0,7 (rendement – jaarlijks gemiddelde) x 0,9 kg/dm³ Hierdoor verminderen we ook de CO2 uitstoot met 7.732 kg per jaar Slagerij Link uit Buchen
  18. 18. Enkele gerealiseerde installaties 18 Geïnstalleerd vermogen en DK warmtewisselaars F7 Snelkoeler THR 45KW / t0-8°C / tc +45°C - 2 x HX 22/16 1.0 => 2 x 6 kW = 12 kW F11 Koelcel THR 60KW / t0-8°C / tc +45°C - 2 x HX 28/20 1.5 => 2 x 9 kW = 18 kW F13 F14 Werkruimten THR 90KW / t0+2°C / tc +45°C - 3 x HX 28/20 1.5 => 3 x 9 kW = 27 kW F15 Diepvriezers 2xTHR 18KW/t0-30°C/tc +45°C - 2 x HX 28/20 1.5 => 3 x 9 kW = 18 kW F16 Koelcel 2 THR 65 KW / t0-8°C / tc +45°C - 2 x HX 28/20 1.5 => 2 x 9 kW = 18 kW Totale recuperatievermogen: 93 kW Geïnstalleerde DK warmterecuperatie: Opslagtank met inhoud van 5.000l, voorzien van 11 interne warmtewisselaars
  19. 19. Enkele gerealiseerde installaties 19 Besparingen: Jaarlijks warmwaterverbruik 3.042 m³ Jaarlijkse stookoliebesparing 20.280 litres Jaarlijkse besparing CO2 uitstoot 58 ton CO2 Jaarlijkse besparing is 10.185 £ (bij 50p/liter) ≈13.800 €/jaar (≈0,68 €/l)
  20. 20. DK Warmteterugwinning 20
  21. 21. DK Warmteterugwinning mit externe warmtewisselaar 21
  22. 22. Logo speaker DK Warmteterugwinning 22 78°C Δ h
  23. 23. Logo speaker DK Warmteterugwinning 23 78°C Δ h
  24. 24. DK Warmteterugwinning mit externe warmtewisselaar 24
  25. 25. DK Warmteterugwinning 25
  26. 26. 2 2 10 29 52 49 79 0 10 20 30 40 50 60 70 80 90 2008 2009 2010 2011 2012 2013 2014 DK Warmteterugwinning voor trans-kritische CO2-units DK warmterecuperatie wordt vaak toegepast in CO2 installaties : •Sinds 5 jaar levert DK op regelmatige basis recuperatiesystemen in Duitsland en Zwitserland •Bijna uitsluitend voor supermarkten DK Warmteterugwinning voor CO2-installaties 26
  27. 27. Voor het opwarmen van drinkbaar water met een interne, dubbelwandige warmtewisselaar Voor het opwarmen van circulatiewater met een interne warmtewisselaar Voor het opwarmen van drinkbaar water met een externe, dubbelwandige warmtewisselaar Voorzien van aansluitingen in roestvrij staal (ook mogelijk in K65) Alle warmtewisselaars geschikt voor: maximum werkdruk 130 bar, maximum temp. 150°C DK Warmteterugwinning voor CO2-installaties 27
  28. 28. DK Warmteterugwinning 28
  29. 29. DK-Opslagtank 29
  30. 30. DK-Opslagtank 30
  31. 31. Special arrangement of the heat exchangers. Different options to reheat (electric heater, heat pump, etc.) DK-Opslagtank 31
  32. 32. Installed cooling machines Deep freeze room LT Qo = 1.63 kW Qc = 2.90 kW Freezer Unit LT Qo = 1.12 kW Qc = 2.00 kW Cold storage NT Qo = 2.20 kW Qc = 3.20 kW Total capacity: Qo = 4.95 kW Qc = 8.1kW Fitted DK-Heat Recovery System: Storage tank with a content of 400 l - raw - 3 single-walled, internal heat exchangers 2 Heat Exchanger 22 mm, 2,5 m², single-walled 1 Heat Exchanger 16 mm, 0,8 m², single-walled 6 kW electrical heater Stainless steel heat exchanger ¾“ / 15 m for mains water heating Westfalentankstelle (Petrol Station) Réservoir d'énergie DK 32
  33. 33. Measuring during the very cold winter 2010/11: Electrical post-heat run during 5 months only 15 h Electricity consumption during the winter 90 kW The side rooms (83 m²) of the petrol station were heating by the waste of the cooling plants (Qo = 4,95 kW / Qc = 8.1 kW ) Drinking water was heated by stainless steel heat exchanger in a continious-flow-system for the snack bar, shop and café Conclusion Nearly the whole heating of the described rooms and warm water preparation could be offered by the DK-Heat Recovery Westfalentankstelle (Petrol Station) Réservoir d'énergie DK 33
  34. 34. Wat hebben we nodig om de juist offerte op te maken DK Warmteterugwinning 34
  35. 35. DK Warmteterugwinning 35

×