Successfully reported this slideshow.
We use your LinkedIn profile and activity data to personalize ads and to show you more relevant ads. You can change your ad preferences anytime.

Inergen

3,095 views

Published on

What is INERGEN?

INERGEN is a mixture of nitrogen, argon and carbon dioxide, and has been specially developed to provide fire protection for sensitive electrical and electronic instruments and equipment.

How does INERGEN work?

INERGEN extinguishes fire by reducing the oxygen level in a room to below 15% (the point at which most combustibles will no longer burn). Simultaneously the patented carbon dioxide in INERGEN protects anyone that may be trapped in the fire area from the effects of the lowered oxygen levels.

Published in: Technology, Business
  • Be the first to comment

Inergen

  1. 1. - TWF - - 300 bar -Components Mail: info@gielle.it - Website: www.gielle.it
  2. 2. Overview• Cylinder assy. with CI 12-9 valve• PRU 300/200 and discharge hose• Manifold & high pressure fittings• Fixing components• Distribution valves• PRU 200/60• Nozzles• Actuation accessories• Other accessories Mail: info@gielle.it - Website: www.gielle.it
  3. 3. System Setup "Orifice" Single Hazard 150/200 bar system 300 bar 150 / 200 bar <200 bar 300 bar system Mail: info@gielle.it - Website: www.gielle.it
  4. 4. System Setup "Orifice" Multiple Hazards 150/200 bar system Pressure reducing unit (orifice) 300 bar 150 / 200 bar 300 bar system <200 bar Mail: info@gielle.it - Website: www.gielle.it
  5. 5. System Setup "Constant Flow" DRV Flow Regulator 200 or 300 bar system 200 / 300 bar max. 60 bar 200 or 300 bar system Seperate Presentation Mail: info@gielle.it - Website: www.gielle.it
  6. 6. Pilot Cylinder Assembly• Container sizes: 8/27/80 litre• Filling: 200 bar Inergen• Approval: TPED (pi-marked)• Assembly consists of – container c/w transport cap – CI 12-6 valve assembly – container label Inergen 200 bar Mail: info@gielle.it - Website: www.gielle.it
  7. 7. Container Valve CI 12-6Functional description: pilot cylinder (200 bar) inlet agent container Mail: info@gielle.it - Website: www.gielle.it
  8. 8. Agent Container Assembly• Container size: 80 litre• Filling: 23.6 m³ (33.5 kg) Inergen @ 300 bar• Approval: TPED (pi-marked)• Assembly consists of – container c/w transport cap – CI 12-9 valve assembly Inergen – container label 300 bar Container = grey Mail: info@gielle.it - Website: www.gielle.it
  9. 9. Container Valve CI 12-8• Type: CI 12-8• Nominal Ø: 12 mm• Max. operating pressure: 360 bar• Release (membrane) – electric – pneumatic p e CI 12-9 – manual Valve rep laced by ty• Bursting disc – @ 65°C 420 bar +30 / -10 bar – @ 20°C 450 bar maximum Mail: info@gielle.it - Website: www.gielle.it
  10. 10. Container Valve CI 12-8Functional description: agent container pressure from pilot cylinder type CI 12-9 Valve re placed by inlet agent container Mail: info@gielle.it - Website: www.gielle.it
  11. 11. Pressure Reducing Unit• PRU 300/200• Type: DRE-V/S for valve CI 12-8• Pressure reduction from 300 bar to 200 bar direct at the valve outlet Orifice plate Diameters 3-9 mm (in steps of 0.5 mm) Mail: info@gielle.it - Website: www.gielle.it
  12. 12. Container Valve CI 12-9• Type: CI 12-9• Nominal Ø: 12 mm• valve outlet is female thread• Max. operating pressure: 360 bar• Release (no membrane) – pneumatic (pilot cylinder)• Bursting disc – @ 65°C 420 bar +30 / -10 bar – @ 20°C 450 bar maximum Mail: info@gielle.it - Website: www.gielle.it
  13. 13. Pressure Reducing Unit• PRU 300/200• Type: DRE-V/S II for valve CI 12-9• Pressure reduction from 300 bar to 200 bar direct at the valve outlet Orifice plate Diameters 3-9 mm (in steps of 0.5 mm) Mail: info@gielle.it - Website: www.gielle.it
  14. 14. Container Valve CI 12-9•Pressure indicator DKE-6 "Standard" Mail: info@gielle.it - Website: www.gielle.it
  15. 15. Container Valve CI 12-9• Pressure indicator KM-4 "Supervisory" Mail: info@gielle.it - Website: www.gielle.it
  16. 16. Discharge Hose• DN 12 / 300 bar• Minimum bend radius: 150 mm• Both ends with swivel nut and pre-installed o-rings• Installation in any orientation. Mail: info@gielle.it - Website: www.gielle.it
  17. 17. Release Head AK III• Puncture pin to open release membrane Puncture pin Mail: info@gielle.it - Website: www.gielle.it
  18. 18. Solenoid Actuator• Standard actuator SF-2 Indicator• 24 V DC / 15 W• IP 65• Swivel nut fits onto release head III• The power lead fitted with a DIN plug for connection to the solenoid is supplied with the solenoid actuator. Mail: info@gielle.it - Website: www.gielle.it
  19. 19. Solenoid Actuator• Explosion proof type• EEx me II T4• 24 V DC / 9 W• IP 65• Swivel nut fits onto release head III• The power lead fitted with a DIN plug for connection to the solenoid is supplied with the solenoid actuator. Mail: info@gielle.it - Website: www.gielle.it
  20. 20. Solenoid Actuator Solenoid actuator Solenoid actuator Release head AK IIIRelease head AK III Container valve CI 12-6 (12-8) Mail: info@gielle.it - Website: www.gielle.it
  21. 21. Step Motor Actuator• Step motor delay device SM V-1• TWF impulse technology• 24 V DC / 15 W• IP 54• At present this technology is only suitable for use with the “Fast 2000” control panel range. Mail: info@gielle.it - Website: www.gielle.it
  22. 22. Actuator Resetting Tool• Used to reset both the standard (SF-2) and the explosion proof solenoid actuator• The tool is supplied with the actuator. Mail: info@gielle.it - Website: www.gielle.it
  23. 23. Local Manual Actuator• Used to manually operate the pilot cylinder• fitted on top of the release head III Manual actuator Release head III Mail: info@gielle.it - Website: www.gielle.it
  24. 24. Pneumatic Actuator PAK• Used in the twin release assembly• installed between the release head AK III and the electric actuating device Mail: info@gielle.it - Website: www.gielle.it
  25. 25. Twin Release• Combination of electric and pneumatic release for the pilot cylinder valve• normal: both valves activated electrically PAK• fault on one electric AK III actuator: both pilot cylinders still opend Mail: info@gielle.it - Website: www.gielle.it
  26. 26. Container Fixing Mail: info@gielle.it - Website: www.gielle.it
  27. 27. Container Fixing• Main components1. Retention ring2. Fixing link3. Retention bar4. Manifold bracket Mail: info@gielle.it - Website: www.gielle.it
  28. 28. Container FixingRetention ring• screws on container neck thread• weight 2.3 kg Mail: info@gielle.it - Website: www.gielle.it
  29. 29. Container FixingFixing link Mail: info@gielle.it - Website: www.gielle.it
  30. 30. Container FixingRetention bar• anchored to the wall• 2 containers / 560 mm• 3 containers / 840 mm Mail: info@gielle.it - Website: www.gielle.it
  31. 31. Container FixingFree standing post• used when there is no wall to fix the retention bar• one post at each end of the retention bar(s) retention bar Mail: info@gielle.it - Website: www.gielle.it
  32. 32. Manifold FixingManifold bracket• bolted to the retention bar• basis for the manifold, which is clamped using U-bolts• short for single long row• long for double row Mail: info@gielle.it - Website: www.gielle.it
  33. 33. Manifolds• 200 bar component supplied by TSP only• pressure tested to 320 bar• nominal diameter = 50 mm• opposite handed threads G2 - ISO 228 (right hand / left hand)• easily connected on site using standard high pressure fittings• plugs and check valves are factory fitted to the inlet ports as specified in the order Mail: info@gielle.it - Website: www.gielle.it
  34. 34. Manifolds"Single" range: 2 / 3 / 4 / 5 container - single row plug Container Container Mail: info@gielle.it - Website: www.gielle.it
  35. 35. Manifolds"Double" range: 4 / 6 / 8 / 10 container - double row plug Container Container Container Container Container Container maximum double row allowed Mail: info@gielle.it - Website: www.gielle.it
  36. 36. High Pressure FittingsAll fittings used in the high pressure 200 bar part ofthe system are supplied by TSP only. Mail: info@gielle.it - Website: www.gielle.it
  37. 37. High Pressure Fittings• nominal diameter: 50 mm / 80 mm• right hand and/or left hand threads G2 - ISO 228• left hand threads are identified by a groove around the diameter of the fitting• fittings are supplied with O-rings for easy connection on site• pressure tested to 360 bar Mail: info@gielle.it - Website: www.gielle.it
  38. 38. High Pressure FittingsUnion joint groove O-ring Mail: info@gielle.it - Website: www.gielle.it
  39. 39. High Pressure FittingsEnd cap C B Mail: info@gielle.it - Website: www.gielle.it
  40. 40. High Pressure FittingsTee Mail: info@gielle.it - Website: www.gielle.it
  41. 41. High Pressure FittingsElbow Mail: info@gielle.it - Website: www.gielle.it
  42. 42. High Pressure FittingsConnecting pipes Mail: info@gielle.it - Website: www.gielle.it
  43. 43. High Pressure FittingsExample: distribution valve manifold Mail: info@gielle.it - Website: www.gielle.it
  44. 44. Actuation Line 200 bar P 1 P P 1 2 Mail: info@gielle.it - Website: www.gielle.it
  45. 45. Actuation Line 200 bar Connection 5 9 hose DN 10 11 6 Lock Off unit Adjustable tee 9 RA10xM16 Actuation 11 hose DN8 6 Agent container 5 Pilot cylinder Mail: info@gielle.it - Website: www.gielle.it
  46. 46. Actuation Line 200 barLock Off unit Required by DIN EN 12094-6 and CEA 4032 Mail: info@gielle.it - Website: www.gielle.it
  47. 47. Actuation Line 200 bar 9 Adjustable tee RA10xM16 11 Actuation hose DN8 30 T-coupling for SGV-2 31 Pressure relief valve ELV-1 32 Automatic vent valve SGV-1 now SGV-2 Mail: info@gielle.it - Website: www.gielle.it
  48. 48. Actuation Line 200 barManual pressure relief valve SGV-2• required for each actuation line• used to manually relieve the residual pilot pressure in the actuation line after a discharge• used to automatically vent minor flow of pilot gas that might occur due to leakage in the pilot system Mail: info@gielle.it - Website: www.gielle.it
  49. 49. Actuation Line 200 barManual pressure relief valve SGV-2• T-coupling P 1 Mail: info@gielle.it - Website: www.gielle.it
  50. 50. Actuation Line 200 barPilot hose DN8 Mail: info@gielle.it - Website: www.gielle.it
  51. 51. Actuation Line 200 barTest and relief unit 1 From pilot cylinder "Main" 2 From pilot cylinder "Reserve" 3 To actuation line 4 Connection for test cylinder 4 3 1 2 Mail: info@gielle.it - Website: www.gielle.it
  52. 52. Pressure Reducing Unit200 bar to 60 bar PRU 200/60 PRU 200/60 PRU 300/200 Mail: info@gielle.it - Website: www.gielle.it
  53. 53. Pressure Reducing Unit DRE-2S (PRU 200/60)  VdS Approved  for single container only Orifice Diameters 1.0 – 5.0 mm (in steps of 0.5 mm)Manual page 71 M18x1.5 (200bar) M24x1.5 (300bar) Mail: info@gielle.it - Website: www.gielle.it
  54. 54. Pressure Reducing UnitDRE-2N (PRU 200/60) Orifice plate with VdS approved 2 O-rings for multiple container systems (single hazard) two sizes availabe  DN 50 – G2" ISO 228 200 bar 60 bar  DN 80 – G3" ISO 228 Orifice sizes 3.0 – 12.0 mm (0.5 mm steps)DN 50 13.0 – 35.0 mm (1.0 mm steps)DN 80 20.0 – 56.0 mm (2.0 mm steps) Mail: info@gielle.it - Website: www.gielle.it
  55. 55. Pressure Reducing UnitDRE-2N (PRU 200/60) VdS approved Mail: info@gielle.it - Website: www.gielle.it
  56. 56. Pressure Reducing UnitDRE-3 (PRU 200/60) NOT VdS approved for multiple container systems one sizes DN 50 200 bar 60 bar  2" NPT or R2" Orifice sizes 3.0 – 12.0 mm (0.5 mm steps)DN 50 13.0 – 35.0 mm (1.0 mm steps) Mail: info@gielle.it - Website: www.gielle.it
  57. 57. Distribution Valve SystemEPSL controlled Control Panel Fire AlarmVdS approved 1 set per hazard pressure reducer SMV Pilot P cylinder Confirmation closed Distribution valve valve open P EPSL300 bar 200 bar 60 bar 10 bar Agent container Mail: info@gielle.it - Website: www.gielle.it
  58. 58. Distribution Valve SystemEPSL controlled Control PanelVdS approvedP P P P EPSL300 bar 200 bar 60 bar 10 bar Agent container Mail: info@gielle.it - Website: www.gielle.it
  59. 59. Distribution Valve SystemEPSL controlledVdS approved EPSL Mail: info@gielle.it - Website: www.gielle.it
  60. 60. Distribution Valve Assy.HD-BV / 3 assembly PRU 200/60 VdS approved closed and unpressurised when in standby mode pilot pressure to open = 10 bar closed manually 3 sizes availabe Orifice sizes 3.0 – 12.0 mm (0.5 mm steps)DN 25 13.0 – 18.0 mm (1.0 mm steps) 200 bar 60 bar 3.0 – 12.0 mm (0.5 mm steps)DN 50 13.0 – 35.0 mm (1.0 mm steps)DN 80 20.0 – 56.0 mm (2.0 mm steps) Mail: info@gielle.it - Website: www.gielle.it
  61. 61. Distribution ValvesH Mail: info@gielle.it - Website: www.gielle.it
  62. 62. Distribution ValvesHD-BV / 3 assembly (VdS approved) DN 25 DN 50 DN 80 Mail: info@gielle.it - Website: www.gielle.it
  63. 63. Distribution Valve Assy.Non VdS assembly closed and unpressurised when in standby mode pilot pressure to open = 7 bar minimum closed manually 50 mm NPT as standard, other Pressure reducing unit sizes on request seperate behind the valve. Mail: info@gielle.it - Website: www.gielle.it
  64. 64. Distribution Valve Assy. 5 RNon VdS assembly R 3b 1 Distribution valve manifold NPT 2 HP union joint 43a set of 2 distribution pipes NPT3b G2"R - 2"NPT and G2"L - 2"NPT 3a 4 Distribution valve L L 5 Pressure reducing unit 2 R R R R 1 Mail: info@gielle.it - Website: www.gielle.it
  65. 65. Distribution PipesThe pipes and fittings downstream the pressure reducer. FM-200® Sapphire™ CO2 TWF / VdS Software Inergen® TSP / Ansul Software Software ??? ??? * Constant Flow Pipe pressure (bar) 20 40 80 100 120 25 60 The installer has to ensure, that the correct pressure rating for pipes and fittings acc. to the flow calculation result is guaranteed.* The final peak pressure in the pipe will result from the hydraulic flow calculation. Mail: info@gielle.it - Website: www.gielle.it
  66. 66. NozzlesIRD nozzle: Not VdS approvedMaterial: Brass (standard)Sizes: ½" NPT or BSPT 1" NPT or BSPT 1 ½" NPT or BSPTPattern: 180° 360 orificeCoverage: 95 m² at max. 3.7 m height 70 m² at max. 5.0 m heightMax. throw: 360°: 5.5 m at Hmax 3.7 m / 4.7 m at Hmax 5.0 m 180°: 7.7 m at Hmax 3.7 m / 6.7 m at Hmax 5.0 m Mail: info@gielle.it - Website: www.gielle.it
  67. 67. NozzlesGRD nozzle: VdS approvedMaterial: Brass (standard)Sizes: R ½" DIN 29999 R 1" DIN 2999Pattern: 360Coverage: 30 m² at max. 5.0 m height orifice Mail: info@gielle.it - Website: www.gielle.it
  68. 68. NozzlesGOD nozzle: VdS approvedMaterial: Brass (standard)Sizes: R ½" DIN 29999 R 1" DIN 2999Pattern: -Coverage: 20 m² for floor voids orificeA R ½" R ½" R ½" R ½" R 1"C 82 mm 97 mm 128 mm 292 mm 296 mmG 50 mm 70 mm 110 mm 110 mm 110 mm Mail: info@gielle.it - Website: www.gielle.it
  69. 69. NozzlesGOD nozzle: VdS approvedorifice Mail: info@gielle.it - Website: www.gielle.it
  70. 70. Discharge Pressure SwitchLatching type reset button• max. working pressure 350 bar• min. 3 bar for operation• mounted in the distribution pipe work or actuation line• SPDT bracket• switches under pressure and latches ¼" NPT femal• manual reset ½" NPT male necessary Mail: info@gielle.it - Website: www.gielle.it
  71. 71. Discharge Pressure SwitchNon-latching type• max. working pressure 120 bar• mounted in the distribution pipe work• SPDT• resets automatically at the lower switch point (4 bar)• IP 65 (housing) IP 54 (cable gland) Mail: info@gielle.it - Website: www.gielle.it
  72. 72. Curtain Trip Assembly• max. working pressure 60 bar• mounted in the distribution pipe work• installation in horizontal cable connected plane to curtain pressure connection 3/8" NPT manual release Mail: info@gielle.it - Website: www.gielle.it
  73. 73. GratesSteel grates, to prevent containers to be standingin dirt/moisture and/or to level the ground 840 mm 560 mm Mail: info@gielle.it - Website: www.gielle.it
  74. 74. Pressure Venting Mail: info@gielle.it - Website: www.gielle.it
  75. 75. Caution PlatesDoor caution plate- No lock-off -Used when it ispermitted to leave thesystem in automaticmode even while thearea is occupied oxygen level > 10%(LOAEL)One plate to be fixedto all entrance doors Mail: info@gielle.it - Website: www.gielle.it
  76. 76. Caution PlatesDoor caution plate- Lock-off -Used when it isnecessary to place thesystem on manualcontrol before enteringthe hazard oxygen level < 10%(LOAEL)One plate to be fixedto all entrance doors Mail: info@gielle.it - Website: www.gielle.it
  77. 77. Caution PlatesManual releaseOne plate to be fixedadjacent to allpositions from wherethe system can bereleased manually. Mail: info@gielle.it - Website: www.gielle.it
  78. 78. Questions? Comments?Tank you for your time!! Mail: info@gielle.it - Website: www.gielle.it
  79. 79. CompanyProfile46 years of expertise andexperience in fireprotectionMail: info@gielle.it - Website: www.gielle.it

×