OPNFV Arno Installation and Validation Walk Through

3,411 views

Published on

  • DOWNLOAD THAT BOOKS INTO AVAILABLE FORMAT (2019 Update) ......................................................................................................................... ......................................................................................................................... Download Full PDF EBOOK here { http://shorturl.at/mzUV6 } ......................................................................................................................... Download Full EPUB Ebook here { http://shorturl.at/mzUV6 } ......................................................................................................................... Download Full doc Ebook here { http://shorturl.at/mzUV6 } ......................................................................................................................... Download PDF EBOOK here { http://shorturl.at/mzUV6 } ......................................................................................................................... Download EPUB Ebook here { http://shorturl.at/mzUV6 } ......................................................................................................................... Download doc Ebook here { http://shorturl.at/mzUV6 } ......................................................................................................................... ......................................................................................................................... ................................................................................................................................... eBook is an electronic version of a traditional print book that can be read by using a personal computer or by using an eBook reader. (An eBook reader can be a software application for use on a computer such as Microsoft's free Reader application, or a book-sized computer that is used solely as a reading device such as Nuvomedia's Rocket eBook.) Users can purchase an eBook on diskette or CD, but the most popular method of getting an eBook is to purchase a downloadable file of the eBook (or other reading material) from a Web site (such as Barnes and Noble) to be read from the user's computer or reading device. Generally, an eBook can be downloaded in five minutes or less ......................................................................................................................... .............. Browse by Genre Available eBooks .............................................................................................................................. Art, Biography, Business, Chick Lit, Children's, Christian, Classics, Comics, Contemporary, Cookbooks, Manga, Memoir, Music, Mystery, Non Fiction, Paranormal, Philosophy, Poetry, Psychology, Religion, Romance, Science, Science Fiction, Self Help, Suspense, Spirituality, Sports, Thriller, Travel, Young Adult, Crime, Ebooks, Fantasy, Fiction, Graphic Novels, Historical Fiction, History, Horror, Humor And Comedy, ......................................................................................................................... ......................................................................................................................... .....BEST SELLER FOR EBOOK RECOMMEND............................................................. ......................................................................................................................... Blowout: Corrupted Democracy, Rogue State Russia, and the Richest, Most Destructive Industry on Earth,-- The Ride of a Lifetime: Lessons Learned from 15 Years as CEO of the Walt Disney Company,-- Call Sign Chaos: Learning to Lead,-- StrengthsFinder 2.0,-- Stillness Is the Key,-- She Said: Breaking the Sexual Harassment Story That Helped Ignite a Movement,-- Atomic Habits: An Easy & Proven Way to Build Good Habits & Break Bad Ones,-- Everything Is Figureoutable,-- What It Takes: Lessons in the Pursuit of Excellence,-- Rich Dad Poor Dad: What the Rich Teach Their Kids About Money That the Poor and Middle Class Do Not!,-- The Total Money Makeover: Classic Edition: A Proven Plan for Financial Fitness,-- Shut Up and Listen!: Hard Business Truths that Will Help You Succeed, ......................................................................................................................... .........................................................................................................................
       Reply 
    Are you sure you want to  Yes  No
    Your message goes here

OPNFV Arno Installation and Validation Walk Through

  1. 1. OPNFV Arno Installation & Validation Walk-Through Nauman Ahad, Wenjing Chu Dell, Inc. 02/07/2015 DELL, INC. 1
  2. 2. Tutorial Overview 1. Hardware description 2. Fuel 2.1: Prerequisites 2.2: Fuel VM Setup 2.3: Fuel GUI Walkthrough to Start POD deployment (Live) 3. Foreman (Already deployed Setup) 3.1: Prerequisites 3.2: Deployment Scripts 3.3: Foreman GUI 3.4: OpenStack+ODL 4. Functests 4.1: Prerequisites 4.2: Functest runs a. Rally (Only Results) b. vPing (live) c. ODL (live) 02/07/2015 DELL, INC. 2
  3. 3. Hardware Setup • 2 PODs POD 1: Fuel POD 2: Foreman • Each POD has 1 Jump Server 3 Control Nodes At least 1 Compute Node 02/07/2015 DELL, INC. 3
  4. 4. POD 1 Fuel • Fuel Installer Runs in a VM inside the Jump Server • Fuel needs 4 Networks: 1. Fuel Admin Network: To PXE boot nodes 2. Storage Network 3. Management Network (Includes Private Network) 4. Public Network • These above networks can be overloaded to a single port using VLAN tagging • We will use 3 ports 1 Port for Public 1 Port for Admin+Storage+Management 1 Port for Lights Out Fuel Internal Network 02/07/2015 DELL, INC. 4
  5. 5. POD 2: Foreman • Foreman Installer Runs in a VM inside the Jump Server • Foreman needs 3 Networks: 1. Foreman Admin Network: To PXE boot nodes 2. Private Network (Includes Management and Storage) 3. Public Network • VLANs (IEEE 802.1 Q tagging) can’t be used to overload networks • At least 4 ports needed. 3 in the specified order 1st Port : Admin 2nd Port: Private (Includes Management and Storage) 3rd Port: Public • An additional Port is needed for Lights out Admin Network Private Network 02/07/2015 DELL, INC. 5
  6. 6. OPNFV-Arno Installation (Fuel) 02/07/2015 DELL, INC. 6
  7. 7. Fetching the Fuel ISO • Get the Fuel ISO from: https://www.opnfv.org/software/download • Run the ISO in a VM on the Jump Server 02/07/2015 DELL, INC. 7
  8. 8. 1. Open Jump- Server Remote Console through Lights out Management (IDRAC) Use a hypervisor (KVM/ virtual box) to boot up the ISO. We used KVM through Virtual Machine Manager 02/07/2015 DELL, INC. 8
  9. 9. 2. Select Downlo aded ISO 02/07/2015 DELL, INC. 9
  10. 10. 3. Set Memory and CPUs for the VM 02/07/2015 DELL, INC. 10
  11. 11. 4a. Bridge First VM virtual port to the Jump server’s second port (eth1). This will be used as the Fuel Admin Network 02/07/2015 DELL, INC. 11
  12. 12. 4b. Add additional Virtual VM port. Bridge it to the Jump server’s Public port (eth0). This will be used for Fuel Public Network. 02/07/2015 DELL, INC. 12
  13. 13. 5. Begin Installation. Press Tab to change Fuel settings. Set show menu from no to yes. 02/07/2015 DELL, INC. 13
  14. 14. 6. In the menu, Enter the network Setup option. Go to eth 1 and provide the public network details. This is done so that Fuel could be accessed remotely 02/07/2015 DELL, INC. 14
  15. 15. 8. Quit setup by entering the “Save and Quit” option 02/07/2015 DELL, INC. 15
  16. 16. 9. Fuel Installation Completes after about 30-40 minutes 02/07/2015 DELL, INC. 16
  17. 17. Deploying a POD using OPNFV- Arno (Fuel) 02/07/2015 DELL, INC. 17
  18. 18. OPNFV-Fuel POD Deployment (Interactive Session) 02/07/2015 DELL, INC. 18
  19. 19. Preparing the POD nodes A: On the POD Nodes, go to the BIOS settings and enable PXE boot on the Network Port that is connected to the Fuel Admin PXE Network 02/07/2015 DELL, INC. 19
  20. 20. Preparing the POD nodes B: On the POD Nodes, go to the BIOS settings and set Network Port that is connected to the Fuel Admin PXE Network as the First Booting Device in the Booting sequence 02/07/2015 DELL, INC. 20
  21. 21. Preparing the POD nodes C: Restart the POD Nodes. The Nodes would be discovered by Fuel and put in bootstrap mode. This means that they will be available for Fuel to be deployed 02/07/2015 DELL, INC. 21
  22. 22. OPNFV-Fuel Specific Steps • Go the Fuel VM • Enter the command “fuel node list” • Note the cluster number (1 in the example below) 02/07/2015 DELL, INC. 22
  23. 23. OPNFV-Fuel Specific Steps • Run the command “ ./opt/opnfv/pre-deploy.sh <Cluster Number>” • The script modifies the Fuel Deployment environment so that provisioned Nodes contain ODL files and scripts. 02/07/2015 DELL, INC. 23
  24. 24. Pre-deployment Script 02/07/2015 DELL, INC. 24
  25. 25. After running the pre deployment scripts, press start deployment on the GUI 02/07/2015 DELL, INC. 25
  26. 26. Deployment Success 02/07/2015 DELL, INC. 26
  27. 27. Fuel-OPNFV Post Deployment 02/07/2015 DELL, INC. 27
  28. 28. • The OPNFV-Fuel Specific scripts earlier shown, installs ODL specific files and scripts and the provisioned controller and compute nodes • http://artifacts.opnfv.org/arno.2015.1.0/fuel/install- guide.arno.2015.1.0.pdf?utm_source=OPNFV.org&utm_medium=Download%20U RLs&utm_content=Fuel%20deployment%20- %20Installation%20Guide&utm_campaign=OPNFV%20/%20Software%20/%20Do wnloads • However a few issues. 1. The “/opt/opnfv/odl/odl_start_container.sh” runs into an error due to conflict with 8080 port. Manually changed it to get around it 2. /opt/opnfv/odl/config_net_odl.sh not present on the compute nodes. Would be improved in the future and is only experimental for the time being 02/07/2015 DELL, INC. 28
  29. 29. OPNFV-Arno (Foreman) 02/07/2015 DELL, INC. 29
  30. 30. Prerequisites • At least 4 Network Ports should be present on the Jump as well as on the POD nodes that are to be provisioned. The ports should have the following order: 1. First Port for Admin Network for PXE booting the POD nodes 2. Second Port for Private + Storage Network 3. Third Port for Public Network • Another port is needed by the Nodes for IPMI/ Remote access controllers (IDRAC). These IPMI/ Remote access controllers should be accessible from the Jump Server 02/07/2015 DELL, INC. 30
  31. 31. Getting the deployment Files • Use Foreman ISO to install CentOS7 on the Foreman Jump-Server https://www.opnfv.org/software/download This ISO packs the required files to deploy Foreman installation • Or download the required deployment files on a Jump-Server installed with CentOS7: https://github.com/trozet/bgs_vagrant/releases/tag/v1.0 • Go to the bgs_vagrant directory on the Jump Server. It contains the deployment files and scripts needed to deploy Foreman. Its contents are shown in the figure below 02/07/2015 DELL, INC. 31
  32. 32. Preparing the POD nodes A: On the POD Nodes, go to the BIOS settings and enable PXE boot on the Network Port that is connected to the Foreman Admin PXE Network 02/07/2015 DELL, INC. 32
  33. 33. Preparing the POD nodes B: On the POD Nodes, go to the BIOS settings and set Network Port that is connected to the Foreman Admin PXE Network as the First Booting Device in the Booting sequence 02/07/2015 DELL, INC. 33
  34. 34. Configuring deployment for the Testbed • The configuration for the bare metal nodes to be deployed in the Foreman POD is to be given in the “opnfv_ksgen_settings.yml” file • Find the control nodes within the file and edit the following: 1. Mac Address for the port connected to Admin PXE network 2. IP for the Remote Access Controller (IDRAC) 3. Mac Address for the Remote Access Controller (IDRAC) 4. Mac Address for the port connected to the Private Network 02/07/2015 DELL, INC. 34
  35. 35. Configuring the opnfv_ksgen_settings.yml for control nodes 02/07/2015 DELL, INC. 35
  36. 36. • Find the compute nodes within the file and edit the following: 1. Mac Address for the port connected to Admin PXE network 2. IP for the Remote Access Controller (IDRAC) 3. Mac Address for the Remote Access Controller (IDRAC) • For each compute node, ensure that the names are different too within the file 02/07/2015 DELL, INC. 36
  37. 37. Configuring the opnfv_ksgen_settings.yml for compute nodes 02/07/2015 DELL, INC. 37
  38. 38. Running the deployment Script • Go to the folder bgs_vagrant • Run the command: “./deploy.sh –base_config <location of the opnfv_ksgen_setting.yaml> 02/07/2015 DELL, INC. 38
  39. 39. Deployment Starts • Continues for 2 hours and deploys OpenStack setup with ODL controller 02/07/2015 DELL, INC. 39
  40. 40. How the Deployment Works • The deploy.sh script takes in hardware specific parameters for the POD nodes to be deployed • The deploy.sh script detects network configuration for the Jump Server • It spins up a Virtual Box VM using Vagrant within the Jump Server • The VM fetches necessary files and sets up Foreman • It also fetches the Khaleesi Framework that does all the automatic installation • Khaleesi consists of Ansible calls made to the Foreman API to deploy the POD 02/07/2015 DELL, INC. 40
  41. 41. Foreman GUI • After a few mins the Installer VM is up and is set up with Foreman • We can access the Foreman GUI using the VM’s public IP • To access the Installer VM, on the Jump Server go to “ cd /tmp/bgs_vagrant/” and run “ vagrant ssh” • This would log you into the Installer VM that runs Foreman to check its public address 02/07/2015 DELL, INC. 41
  42. 42. After Deployment Foreman Dashboard 02/07/2015 DELL, INC. 42
  43. 43. ODL • ODL runs on the first controller and can be accessed: <IP of controller>:8181/dlux/index.html 02/07/2015 DELL, INC. 43
  44. 44. Functests 02/07/2015 DELL, INC. 44
  45. 45. Fetching Functests • On the Jump Server, Clone the Functest repository by running “git clone https://gerrit.opnfv.org/gerrit/functest” • Fetch the OpenStack RC file for the deployment to be tested • Source the download admin-openrc file • Go to the functest repository that is cloned • Go to testcases directory and run : python config_python –d <functest repository location> 02/07/2015 DELL, INC. 45
  46. 46. • This script fetches the needed testing tools that are used by Functests • Includes: 1. Rally 2. Tempest 3. Vping 4. Robot 5. Downloads Glance Images 02/07/2015 DELL, INC. 46
  47. 47. Running Tests • http://artifacts.opnfv.org/arno.2015.1.0/docs/functest.arno.2015.1.0. pdf 02/07/2015 DELL, INC. 47
  48. 48. Rally Tests • Rally bench suite can be used to benchmark OpenStack components such as glance, Nova, Neutron, Cinder etc and generate results in .html pages • To run: “python <functest dir>/testcases/VIM/OpenStack/CI/libraries/run_rally.py <functest dir> <test> Where test can be 1. Authentication 2. Cinder 3. Glance 4. Nova 5. Neutron 6. all (runs all above) 02/07/2015 DELL, INC. 48
  49. 49. Tempest Tests • Rally uses Tempest to run smoke tests • Run “ rally verify start smoke” 02/07/2015 DELL, INC. 49
  50. 50. vPING (Live) • Uses OpenStack to create 2 VMs and one network. The 2 VMs are connected to this created network and are assigned Ips • A simple Ping test is performed between these 2 VMs • To run: “python <functest_dir>/testcases/vPing/CI/libraries/vPing.py –d <functest_dir>” 02/07/2015 DELL, INC. 50
  51. 51. ODL Tests (Live) • Checks if ODL is accessible and performs basic testing • Run “. <functest_dir>/testcases/Controllers/ODL/CI/start_tests.sh” 02/07/2015 DELL, INC. 51

×