Successfully reported this slideshow.
Your SlideShare is downloading. ×
Ad
Ad
Ad
Ad
Ad
Ad
Ad
Ad
Ad
Ad
Ad
Loading in …3
×

Check these out next

1 of 2 Ad

Thông số kĩ thuật schneider tụ bù schneider

Download to read offline

Thông số kĩ thuật schneider tụ bù schneider

Thông số kĩ thuật schneider tụ bù schneider

Advertisement
Advertisement

More Related Content

More from Công ty cổ phần OKS | Tổng thầu thi công Nhà máy GMP, Tổng thầu thi công Nhà kho GSP (20)

Recently uploaded (20)

Advertisement

Thông số kĩ thuật schneider tụ bù schneider

  1. 1. Power factor correction Varplus2, VarplusCan & VarplusBox Varplus2 Modular capacitors are 3 phase, 50 Hz and are using HQ protection system providing protection against high and low current faults. Life time: 130,000 hours (15 years) Safety of personnel: internal discharge resistance Varplus • Aluminum can enclosure Can • Self-healing + overpressure disconnector • Ambient temperature: -25/+55°C Class D and up to 70°C • Life time: Up to 150,000 hours • Degree of protection : IP30, (IP54 on request) Varplus • Steel box enclosure Box • Self-healing + overpressure disconnector • Ambient temperature: -25/+55°C Class D and up to 70°C • Life time: Up to 160,000 hours • Degree of protection: IP30, (IP54 on request) Varplus2 Tụ điện loại 3 pha, 50Hz có hệ thống bảo vệ HQ, chống lại những sự cố do dòng điện cao và thấp. Tuổi thọ: 130,000 giờ (15 năm) Bảo vệ con người: điện trở xả bên trong Varplus • Vỏ tụ bằng nhôm Can • Tự hàn + cách ly khi quá áp suất • Nhiệt độ xung quanh: -25/+55°C Class D và đến 70°C • Tuổi thọ đến 150,000 hours • Cấp độ bảo vệ: IP30, (IP54 yêu cầu) Varplus • Vỏ tụ bằng thép Box • Tự hàn + cách ly khi quá áp suất • Nhiệt độ xung quanh: -25 /+55°C Class D và đến 70°C • Tuổi thọ đến 160,000 hours • Cấp độ bảo vệ: IP30, (IP54 yêu cầu) Varplus2 Capacitors Varplus2 Unit price (excl.VAT) in USD Type Unit PriceReference 51311 51315 51317 51319 51321 176.97 189.92 198.55 205.02 215.81 Voltage (V)Power (kVar) 5 7.5 10 12.5 15 400 400 400 400 400 VarplusCan Capacitors VarplusCan Type Unit PriceReference BLRCS050A060B40 BLRCS075A090B40 BLRCS104A125B40 BLRCS125A150B40 BLRCS150A180B40 BLRCS200A240B40 BLRCS250A300B40 35.08 52.62 70.16 87.71 105.25 140.33 175.41 Voltage (V)Power (kVar) 5 7.5 10 12.5 15 20 25 400 400 400 400 400 400 400 VarplusBox Capacitors VarplusBox Type Unit PriceReference BLRBS075A090B40 BLRBS104A125B40 BLRBS125A150B40 BLRBS150A180B40 BLRBS208A250B40 BLRBS250A300B40 BLRBS500A600B40 BLRBS750A900B40 BLRBSX00AX20B40 78.94 87.71 109.63 131.56 175.41 219.26 438.53 855.13 1,140.18 Voltage (V)Power (kVar) 7.5 10 12.5 15 20 25 50 75 100 400 400 400 400 400 400 400 400 400 Accessories Varplus2 Type Unit PriceReference 51459 51461 29.01 37.67 1 set of 3-phase copper bars for connection and assembly of 2 and 3 capacitors 1 set of protective cover (IP20) and cable glands (IP42) for 1, 2 and 3 capacitors Detuning reactor controller harmonic suppression inductor 12.5 50 Power (kVar) Unit PriceReference 52352 52354 612.36 1,152.00 Varlogic power factor controller Varlogic NR6 Varlogic NR12 Type Unit PriceReference 52448 52449 640.93 802.70 Number of step output contact 6 steps 12 steps Please contact our distributors or Schneider Electric for further information. Vui lòng liên hệ nhà phân phối hoặc Schneider Electric để biết thêm chi tiết 87
  2. 2. Order form Masterpact NT and NW order form To indicate your choice, check the applicable square boxes Indication contacts OF - ON/OFF indication contacts and enter the appropriate information in the rectangles Standard 4 OF 6 A-240 V AC (10 A-240 V AC and low-level for NW) Alternate 1 OF low-level for NT Max. 4 qty Additional 1 block of 4 OF for NW Max. 2 qty Circuit breaker Quantity EF - combined "connected/closed" contacts or switch-disconnector 1 EF 6 A-240 V AC for NW Max. 8 qty Masterpact type NT NW 1 EF low-level for NW Max. 8 qty Rating A SDE - "fault-trip" indication contact Sensor rating A Standard 1 SDE 6 A-240 V AC Circuit breaker N1, H1, H2, H3, L1 Additional 1 SDE 6 A-240 V AC 1 SDE low level Special circuit breaker H2 anticorrosion, H10 Carriage switches Low level 6 A-240 V AC Switch-disconnector NA, HA, HF, HA10, ES CE- "connected" position Max. 3 for NW/NT qty Number of poles 3 or 4 CD- "disconnected" position Max. 3 for NW - 2 for NT qty Brand MG SD CT- "test" position Max. 3 for NW - 1 for NT qty Option: neutral on right side AC - NW actuator for 6 CE - 3 CD - 0 CT additional carriage switches qty Type of equipment Fixed Remote operation Drawout with chassis Remote ON/OFF MCH - gear motor V Drawout without chassis XF - closing voltage release V (moving part only) MX - opening voltage release V Chassis alone PF - "ready to close" contact Low level Earthing switch kit for chassis 6 A-240 V AC Micrologic control unit BPFE - electrical closing pushbutton A - ammeter 2.0 5.0 6.0 Res - electrical reset option (only can choose between Res or RAR) V P - power meter 5.0 6.0 RAR - automatic reset optionH - harmonic meter 5.0 6.0 Choose only 1 option, Res or RARLR- long-time rating plug Standard 0.4 to 1 Ir Remote tripping MN- undervoltage release VLow setting 0.4 to 0.8 Ir MN + R - delay unit (non-adjustable) VHigh setting 0.8 to 1 Ir MN + Res- adjustable delay unit VLR OFF 2nd MX - shunt release VAD - external power-supply module V If you choose 2nd MX, please don not choose any option MNBAT - battery module LockingTCE - external sensor (CT) for neutral VBP - ON/OFF pushbutton locking (by transparent cover + padlocks)and residual earth-fault protection OFF position locking:TCE - external sensor (CT) for over sized neutral VCPO- by padlocks(3P - Micrologic P / H) and residual earth-fault protection VSPO - by keylocks Keyock kit (w/o keylock) Profalux RonisTCW - external sensor for SGR protection 1 keylock Profalux RonisRectangular sensor NT (280 x 115 mm) 2 identical keylocks, 1 key Profalux Ronisfor earth-leakage protection NW (470 x 160 mm) 2 keylocks, different keys (NW) Profalux Profalux RonisPTE - external voltage connector Chassis locking in "disconnected" position:Communication VSPD- by keylocks Keyock kit (w/o keylock) Profalux RonisCOM module JBus/ Device Kirk CastellModBus 1 keylock Profalux RonisDigipact Device 2 identical keylocks, 1 key Profalux RonisEco COM ModBus 2 keylocks, different keys Profalux Ronismodule (for XF or MX communicating release) Optional connected/disconnected/test position lockConnection VPEC -door interlock On right-hand side chassisHorizontal Top Bottom On left-hand side chassisVertical Top Bottom VPOC - racking interlockFront Top Bottom IPA - cable-type door interlockInterphase barriers NT, NW fixed, drawout VDC - mismatch protection VIVC - shutter position indication and locking for NW IBPO - racking interlock between crank and OFF pushbutton for NW DAE - automatic spring discharge before breaker removal for NWMicrologic control unit functions: Accessories2.0 : basic protection (long time + inst.) CDM - mechanical operation counter NT, NW5.0 : selective protection (long time + short time + inst.) CB - auxiliary terminal shield for chassis NT, NW6.0 : selective + earth-fault protection CC - arc chute cover for fixed NT(long time + short time + inst. + earth-fault) CDP- escutcheon NT, NW7.0 : selective + earth-leakage protection CP- transparent cover for escutcheon NT, NW(long time + short time + inst. + earth-leakage) OP- blanking plate for escutcheon NT, NW Brackets for mounting NW fixed On backplates Test kits Mini test kit Portable test kit Chassis Chassis 7.0 7.0 7.0 Please contact our distributors or Schneider Electric for further information. Vui lòng liên hệ nhà phân phối hoặc Schneider Electric để biết thêm chi tiết88

×