  1. 1. FleX-Net Network Series Overview  The FleX-Net system is designed to establish Mircom as major player against key competitive fire alarm manufacturers with networking capabilities; Notifier EST Siemens Simplex
  2. 2. FleX-Net Network Series Overview  Based on the proven and reliable FX- 2000 Series platform  Most of the existing functionality of the FX-2000 is maintained or enhanced  QX-5000 Series audio system is integrated into the FleX-Net system Network system provides a fully distributed audio system  Firefighter’s telephone are integrated into the FleX-Net to form a networked telephone system
  3. 3. FleX-Net Network Series Overview  Unites multiple FleX-Net intelligent fire alarm control panels as one system Supports copper and/or fiber optic network cable  All control panels operate independently, but as a cohesive system for unified response  Enhanced survivability – communications loss will not compromise the system  Easily accommodates future growth
  4. 4. FleX-Net Network Series Overview  FleX-Net main board is equipped with one Signaling Line Circuit, two conventional non-addressable loops, and 4 Notification Appliance Circuits  The FleX-Net system has the look and feel of the FX-2000  Each node supports up to 28 SLCs and up to 7 remote annunciators  Each node supports a maximum of 5000 addressable points  The FleX-Net system has a faster processor with more memory to allow for future enhancements
  5. 5. FleX-Net Series Network Features  Up to 63 nodes  A node can be; Building Command Center A group of floors within a building  Multiple Control Centers  Peer-to-Peer Network Communications  Proprietary ARCnet Communication Protocol Long track record as industrial networking technology  Redundant Class B or Class A Wiring Configuration
  6. 6. FleX-Net Series Network Features  Built-in BACnet Compatibility  Built-in Computer Graphics software  Built-in Web Server  RS-232 port for event printer or hyperterminal
  7. 7. FleX-Net Series Configuration Features  FXConfig software supports network wide configuration  DACT and Audio system are integrated into the Configuration software  Simple easy-to-use interface and one-click downloading of job to panels  Ability to export to XML Generate reports for maintenance
  8. 8. FleX-Net Network Applications Airports Hotels & Resorts Colleges & Universities Office Buildings Hospitals High Rise Buildings
  9. 9. Target Customers  Medium to large-scale facilities  Hospitality Hotels Resorts  Retail/Shopping Malls  Department Stores  High Rise Buildings  Banks  Education Schools (Elementary, High and Middle Schools),  Universities/Colleges Dormitories, Campus Buildings, Administration Buildings  Manufacturing Facilities  Corporate Headquarters  Airports  Healthcare Hospitals Long Term Care Facilities
  10. 10. FleX-Net Network  Supports all FleX-Net intelligent systems FX-2003-12NDS FX-2017-12NDS FX-2009-12NDS FX-MNS
  11. 11. FleX-Net Series Network Main Chassis  The FleX-Net Network Main Chassis: Support the FNC-2000 Fire Network Controller Module Support conventional, non-addressable adder modules Have the same design as the existing FX-2000 main chassis
  12. 12. FX-2003-12NDS Compact Network Main Chassis  One SLC, Class C or Class A.  Four NACs, Class B or Class A, rated for 1.7A each.  Includes a 4 line by 20 character back-lit LCD display.  12A Power Supply.  Will accommodate three internal adder modules (e.g. network card, DACT, quad loop adder).  Will accommodate two display adders (e.g. IPS-2424, RAX-1048, FDX-008).
  13. 13. FX-2003-12NDS Compact Network Main Chassis FX-2000 Main BoardMain Board Left-most slot is reserved for a DACT or PR-100 adder module. If neither is required, this slot can be used for other adder modules. It is recommended to locate the network card at position #2
  14. 14. FX-2017-12NDS Mid Size Network Main Chassis  One SLC, Class C or Class A.  Four NACs, Class B or Class A, rated for 1.7A each.  Includes a 4 line by 20 character back-lit LCD display.  12A Power Supply.  Will accommodate 17 internal adder modules (e.g. network card, DACT, quad loop adder).  Will accommodate three display adders (e.g. IPS- 2424, RAX-1048, FDX-008).
  15. 15. FX-2017-12NDS Mid Size Network Main Chassis It is recommended to locate the FNC-2000 network card at position #2
  16. 16. FX-2009-12NDS Large Network Main Chassis  One SLC, Class C or Class A.  Four NACs, Class B or Class A, rated for 1.7A each.  A 4 line by 20 character back-lit LCD display.  12A Power Supply.  Will accommodate 9 internal adder modules (e.g. network card, DACT, quad loop adder).  The BB-5008 box will accommodate 7 display adders, using expansion chassis’.  The BB-5014 box will accommodate 13 display adders using expansion chassis’. or
  17. 17. FX-2009-12NDS Large Network Main Chassis It is recommended to locate the network card at position #2
  18. 18. FleX-Net Applications Size of Application FX-2003-12NDS FX-2017-12NDS FX-2009-12NDS Small X Medium X X Large X With Voice Evacuation and Fire Fighter Telephones X
  19. 19. FNC-2000 Fire Network Controller Module  Provides network capability to the FleX-Net Series  Interface for connecting the optional FOM-2000-SP Fiber Optic Network Adder Module  Mounts in any of the FleX-Net fire alarm main chassis
  20. 20. FOM-2000-SP Fiber Optic Network Adder Module  Allows for the use of fiber optic cabling on the FleX- Net Series panels  Seamlessly connects to the interface on the FNC- 2000 Fire Alarm Network Controller Module
  21. 21. FleX-Net Adder Modules  FleX-Net supports the following adder modules;  Loop Controller ALC-792M Quad Loop Adder  Conventional Adder Modules DM-1008A Initiating Device Ckt SGM-1004A Supervised Output RM-1008A Relay Module  Auxiliary Adder Modules UDACT-300A PR-300 Polarity Reversal Module
  22. 22. RAXN-LCD Network Remote LCD Annunciator  4 lines x 24 character LCD Annunciator  Connects to any node via RS-485 to annunciate the network system  Does not take up a node address  3 ribbon headers support display adders  Mounts in a BB-1000 or BB-5000 Series enclosure Mircom FleX-Net Fire Alarm Control Panel Normal Condition June 18, 2014
  23. 23.  24 lines x 40 character LCD Annunciator  Connects to any node via RS-485 to annunciate the network system  Does not take up a node address  3 ribbon headers support display adders  Mounts in a BB-1000 or BB-5000 Series enclosure RAXN-LCDG Remote Graphic Annunciator
  24. 24. FleX-Net Annunciators and Programmable Modules  FleX-Net supports the following display adders;  LED Annunciator RAX-1048TZ  Graphic Driver Modules MDG-32 AGD-048  Programmable Switches FDX-008 IPS-2424
  25. 25.  Intelligent network panel that supports: Main fire alarm chassis Network Controller Modules ▪ Fire, Audio, & Telephone modules Audio card cage ▪ Supports up to four 60-watt QAA style amplifiers 30 Amp power supply Room for up to a 40AH battery-set  Requires BBX-FXMNS enclosure FleX-Net Integrated Fire and Audio Network Panel
  26. 26. FX-MNS Integrated Fire Alarm Network Main Chassis  One SLC, Class C or Class A.  Four NACs, Class B or Class A, rated for 1.7A each.  A 4 line by 20 character back-lit LCD display.  12A Power Supply.  Will accommodate 17 internal adder modules (e.g. network card, DACT, quad loop adder).  Will accommodate three display adders (e.g. IPS-2424, RAX-1048, FDX-008).
  27. 27. QMB-5000N Main Audio Network Card Cage Audio and Telephone Control  Multi-channel operation  Distributed audio  5 telephone channels (with TNC- 5000)  Multiple amplifier sizes  Uses existing QAA style amplifiers Maximum of 4 QAA style amplifiers Maximum of 180 watts per enclosure  Amplifiers mount in audio card cage  Maximum of 3 QBB-5001 audio cabinets can be connected to the FX-MNS Maximum of 3 X 360 Watts  Up to 540W per node
  28. 28. FleX-Net Audio Features  Multi-Channel Operation Alarm tone can be different per node Alert tone can be different per node Paging is common per system  Five Telephone Handset Circuits on the node Conventional or; Addressable  Each node will support a master telephone
  29. 29. ANC-5000 Audio Network Controller Module  Provides audio microphone control on the network system  Provides space for an Alert and Evacuation digital voice message  Mounts on a plate in the QMB-5000N audio card cage or in the FX-MNS main chassis
  30. 30. TNC-5000 Telephone Network Controller Module  Provides 5 hardwired telephone circuits for the local floor panel with circuit #1 configurable for the master telephone handset  Provides network communication path  Mounts with the ANC-5000 on a plate in the QMB-5000N main chassis or in the FX-MNS
  31. 31. QMB-5000N Audio Card Cage TNC-5000 Telephone Network Controller Module ANC-5000 Audio Network Controller Module The black plate mounts in the first slot of the QMB-5000N audio card cage Space for 4 QAA style amplifiers Both the ANC-5000 and TNC-5000 mount on a black plate
  32. 32. QAA Style Amplifiers  System uses existing QX- 5000 Series audio amplifiers  25/70 volt models QAA-5415-25 QAA-5415-70 QAA-5230 QAA-5160  Amplifiers mount in the QMB-5000N audio card cage
  33. 33. Audio Expansion Ribbon Cable Maximum of 3 QBB-5001 cabinetsFleX-NetTM Integrated Fire & Voice Panel Max. 180 watts QBB-5001 Max. 360 watts QBB-5001 Max. 360 watts QBB-5001 Max. 360 watts
  34. 34. QMB-5000 card rack in a QBB-5001 Box yields 360W Audio Expansion
  35. 35. Up to 7 Remote LOCs per NodeFleX-NetTM Integrated Fire & Voice Panel ACU – Autonomous Control Unit Remote LOCs
  36. 36. QMP-5101N Network Master Microphone Paging Module  Network capable  Includes master paging microphone and common control functions  Used with the QAZT- 5302 selector panel  Mounts in a BB-5008 or BB-5014 enclosure
  37. 37. QMT-5302N Network Master Telephone Control Module  Network capable  Includes master telephone handset and common control functions  Used with the QAZT- 5302 selector panel  Mounts in a BB-5008 or BB-5014 enclosure
  38. 38. QAZT-5302 Paging and Telephone Selector Module  Provides zoned paging and telephone selection  Connects to: QMP-5101N Master Paging Module QMT-5302N Master Telephone Control Module
  39. 39. OpenGN Graphics Software  An aesthetically pleasing high quality customizable graphical interface between administrators and monitored buildings  Building ready monitoring control system with full software management in a user friendly graphical enabled interface  Easy configuration and customization of alarm devices  Remote desktop programming from any location  Upload/download configuration files without taking the whole system off-line  Customizable fire annunciation graphical icons to provide customer specific site representation